• 제목/요약/키워드: Restriction device

Search Result 88, Processing Time 0.022 seconds

A study on the sleeve-shaped platform of POF-based joint angle sensor for arm movement-monitoring clothing (인체동작 모니터링 위한 광섬유 기반 의류 소매형 동작센서 연구)

  • Kang, Da-Hye;Lee, Young-Jae;Lee, Jeong-Whan;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.14 no.2
    • /
    • pp.221-226
    • /
    • 2011
  • Although diverse researches on sensing method of human movement have been performed, there are still many limitations to the existing methods. As a part of supplementing the limitations to the existing motion sensing methods, this study aimed to execute an exploratory examination on a POF-based sleeve-shaped motion sensor for less restrictive sensing of human movement. In this study, a set of POF-based motion sensor, which was embedded in a sleeve-shaped platform was devised, and a set of exploratory experiments was performed on the possibility of sensing of human movement as diverse as in daily life, through this device. The scope of this research was limited to an exploration on the possibility and basic elements of POF-based sleeve-shaped motion sensor, while the influence of sleeve patterns, those of wearer's somatotype, those of sewing method were not studied in this study. When compared to the pre-existing methods, the POF-based motion sensor platformed on sleeve in this study, which was purposively devised to be applied to the motion sensing clothing shows some beneficial characteristics : more sensitive measurement on human motion, low cost, no timely restriction in sensing, no request for gigantic apparatus and space for sensing.

  • PDF

Development of Micro Wired pH Electrode for Real-Time Monitoring for Gastroesophageal Reflux (위식도 역류 실시간 모니터링 마이크로 와이어 pH 전극 개발)

  • Kim, Eung-Bo;Lee, Kyu-Jin;So, Sang-Kyun;Joung, Yeun-Ho;Park, Jung Ho;Kim, Nam Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.277-284
    • /
    • 2017
  • This paper presents an implantable pH measurement electrode for wireless gastroesophageal reflux measurement. Usually, gastroesophageal reflux is diagnosed by a catheter-type wire connection between the esophagus and the diagnostic device which brings many side effects such as restriction of daily living, pain, and discomfort in the nasal cavity and pharynx of patients. In order to solve these issues, researchers have been studied a wireless measurement method and a micro-sized pH electrode for human body insertion is necessary. Commercial glass packaged pH meter is formed by a sensing and a reference electrodes in a KCl solution. However, if the glass meter is inserted into the human body, there are risks of leakage of the solution, breakage of the glass package, injury of the body elements. Therefore, the solution should be solidified on the micro-sized noble metal wire which has a characteristic of biocompatible. After solidified wire fabrication, the designed meter was tested for feasibility of measurement and the result was well agreed with pH values of commercial pH meter. Potentials in pH 1 to 12 solution was measured to obtain the sensitivity of the sensor with linearity. And we have designed a simulation of gastroesophageal reflux with symptom frequency, interval, and duration time in pH 2 solution. The proposed sensor has capable to get the same potential for 24 measurements in 3 days, and it has sensed same pH values of 2 for one hour with every 10 minutes. Furthermore, the sensor was survived for 48 hours with reasonable potentials in the acid solution.

A Hand Gesture Recognition System using 3D Tracking Volume Restriction Technique (3차원 추적영역 제한 기법을 이용한 손 동작 인식 시스템)

  • Kim, Kyung-Ho;Jung, Da-Un;Lee, Seok-Han;Choi, Jong-Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.201-211
    • /
    • 2013
  • In this paper, we propose a hand tracking and gesture recognition system. Our system employs a depth capture device to obtain 3D geometric information of user's bare hand. In particular, we build a flexible tracking volume and restrict the hand tracking area, so that we can avoid diverse problems caused by conventional object detection/tracking systems. The proposed system computes running average of the hand position, and tracking volume is actively adjusted according to the statistical information that is computed on the basis of uncertainty of the user's hand motion in the 3D space. Once the position of user's hand is obtained, then the system attempts to detect stretched fingers to recognize finger gesture of the user's hand. In order to test the proposed framework, we built a NUI system using the proposed technique, and verified that our system presents very stable performance even in the case that multiple objects exist simultaneously in the crowded environment, as well as in the situation that the scene is occluded temporarily. We also verified that our system ensures running speed of 24-30 frames per second throughout the experiments.

A study on oral health status and oral health behavior practice perceived by workers in part areas (일부 지역의 근로자가 지각하는 구강건강상태와 구강건강행위실천에 관한 연구)

  • Kim, Mi-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.1
    • /
    • pp.201-212
    • /
    • 2012
  • Objectives : The purpose of this study was to examine about workers' oral health status and oral health behavior practice. Methods : Questionnaire survey was carried out targeting 331 workers within the industrial complex of Jeonju city in 2011. As a result of surveying and analyzing workers' oral health status, habit related to oral health, activity restriction, which is oral disease phase, and oral health practice level by using SPSSWIN 12.0. Results : 1. Workers' experience of visiting dental hospital(clinic) for the past one year was indicated to be the highest with 64.9% in the working period with 10 years-under 20 years(p<0.001). Experience of scaling was indicated to be averagely 38.8%. 2. The oral health status perceived by workers was the highest with 40.5% in 'having something abnormal'. A problem was the highest with 28.0% in 'dental caries'. A cause was indicated to be 42.6% in 'because of being naturally weak in tooth or the gum.' The biggest reason for having failed to receive the dental treatment at a proper time was indicated to be the highest with 24.8% in 'because of feeling burdensome about dental expense. '3. 58.4% of male workers were smoking. The use of dental hygiene device was the highest with 40.6% in mouth-rinse. 4. Absence caused by oral disease was indicated to be the highest with 13.8% in the household income in more than 3,500,000won, thereby having shown the significant difference(p<0.05). Early leaving was indicated to be the highest 13.9% in more than 50s age, thereby having shown the significant difference(p<0.05). Also, as for factors of absence and early leaving, a pain was the highest with 64.7%. 5. Workers' oral health practice level was the highest with 2.85 points in 'Brushing teeth before going to bed'. Conclusions : Synthesizing these findings, the oral management could be known to be made negligently in the workers with the older age, the lower academic background, and the lower income. The institutional foundation is considered to be necessary for which the oral health education can be efficiently performed in addition to a need of periodic oral examination for these classes.

CPLD-based Controller for Bi-directional Communication in a Capsule Endoscope (캡슐형 무선 내시경의 양방향 통신을 위한 CPLD 기반의 제어기 설계 및 구현)

  • Lee Jyung Hyun;Moon Yeon Kwan;Park Hee Joon;Won Chul Ho;Lee Seung Ha;Choi Hyun Chul;Cho Jin Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.447-453
    • /
    • 2004
  • In the case of a capsule that can acquire and transmit images from the intestines, the size of the module and the battery capacity in the capsule are subject to restriction. The capsule must be swallowable and the battery must maintain the stable power during the capsule travels in the gastrointestinal tract. Therefore, it is important to control the endoscope using bi-directional wireless communication. In this study, encoder and decoder CPLD modules for bi-directional capsule endoscopes were designed and implemented. The designed controller for capsule endoscope can transmit the images of GI-track from inside to outside of the body and the capsules can be controlled by external controller simultaneously. The designed and implemented controller was verified by an in-vivo animal experiments. From these experiments, it was verified that the CPLD module for bi-directional capsule endoscope satisfied the design specifications.

Effects of Size Illusion According to Distance Information Restriction on Time Perception (거리 정보 제한에 따른 크기 착시가 시간 지각에 미치는 영향)

  • Kim, Min-Kyu;Lee, Won-Seob;Kim, Shin-Woo;Li, Hyung-Chul O.
    • Science of Emotion and Sensibility
    • /
    • v.25 no.1
    • /
    • pp.79-90
    • /
    • 2022
  • IThe perception of sub-second duration through the visual sensory system is affected by non-temporal characteristics (factors other than the duration of the stimulus). However, studies have shown that if distance information is abundant and size constancy maintained, the duration of the target is constantly perceived. The current study examined the relationship between size and time perception constancy in a three-dimensional environment with limited distance information. A device was constructed to limit the participants' bilateral and monocular cues. This prevented participants from maintaining size constancy, resulting in size illusions that could not accurately perceive physical size. In Experiment 1, the size of the physical stimulus of reference and test stimuli were the same at all viewing distances. The results suggest that, despite the same physical size, stimuli with close observations were perceived to be greater and lasted longer. In Experiment 2, the retinal size of the reference stimuli and test stimuli was controlled equally at all viewing distances. As a result, although the physical size of the stimuli increased as the observation increased, the perceived size of all the stimuli was the same. Therefore, the duration of the target was constantly perceived at all viewing distances. The results of this study demonstrate that even when distance information is limited, time perception is affected by the perceived size of the object. It also suggests that when rich distance information exists, the duration of the object can be constantly perceived even if the observation distance varies.

Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR (폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.35-46
    • /
    • 2021
  • Purpose : By comparing and analyzing treatment plans using abdominal compression and The Continuous Positive Air Pressure(CPAP) during SABR of lung cancer, we try to contribute to the improvement of radiotherapy effect. Materials & Methods : In two of the lung SABR patients(A, B patient), we developed a SABR plan using abdominal compression device(the Body Pro-Lok, BPL) and CPAP and analyze the treatment plan through homogeneity, conformity and the parameters proposed in RTOG 0813. Furthermore, for each phase, the X, Y, and Z axis movements centered on PTV are analyzed in all 4D CTs and compared by obtaining the volume and average dose of PTV and OAR. Four cone beam computed tomography(CBCT) were used to measure the directions from the center of the PTV to the intrathoracic contacts in three directions out of 0°, 90°, 180° and 270°, and compare the differences from the average distance values in each direction. Result : Both treatment plans obtained using BPL and CPAP followed recommendations from RTOG, and there was no significant difference in homogeneity and conformity. The X-axis, Y-axis, and Z-axis movements centered on PTV in patient A were 0.49 cm, 0.37 cm, 1.66 cm with BPL and 0.16 cm, 0.12 cm, and 0.19 cm with CPAP, in patient B were 0.22 cm, 0.18 cm, 1.03 cm with BPL and 0.14 cm, 0.11 cm, and 0.4 cm with CPAP. In A patient, when using CPAP compared to BPL, ITV decreased by 46.27% and left lung volume increased by 41.94%, and average dose decreased by 52.81% in the heart. In B patient, volume increased by 106.89% in the left lung and 87.32% in the right lung, with an average dose decreased by 44.30% in the stomach. The maximum difference of A patient between the straight distance value and the mean distance value in each direction was 0.05 cm in the a-direction, 0.05 cm in the b-direction, and 0.41 cm in the c-direction. In B patient, there was a difference of 0.19 cm in the d-direction, 0.49 cm in the e-direction, and 0.06 cm in the f-direction. Conclusion : We confirm that increased lung volume with CPAP can reduce doses of OAR near the target more effectively than with BPL, and also contribute more effectively to restriction of tumor movement with respiration. It is considered that radiation therapy effects can be improved through the application of various sites of CPAP and the combination with CPAP and other treatment machines.

Pornographic Animation's Sexuality through Japanese Sex Culture (일본의 성문화를 통해 본 포르노그래피 애니메이션의 선정성)

  • Choi, Eun-Hye;Oh, Jin-Hee
    • Cartoon and Animation Studies
    • /
    • s.36
    • /
    • pp.281-302
    • /
    • 2014
  • Human beings have advanced to release instinctive desire. Among the human desires, sexual desire is classed as a basic desire with appetite and has been expressed in many ways from prehistoric times to present. Despite the social and ethical restriction, expression of sexual image has been evolved with change of time and medium's development. Thanks to inventing the photograph technique, Change of pornographic image has showed a dramatic aspect since early 20th century. The video which delivers message more directly than the picture boosted this change, and the animation has experimented the expression methods and techniques numerously exceeding the limit of realistic image which reappeared by the device. In this thesis, I want to discuss how human beings express sexual desire in animation based on society's sex culture, and analyzed Japanese pornographic animation as its obvious cases. Japanese pornographic animation should be interpreted as the result of culture and society system's history. Through Heian, Edo and early Meiji period, Japanese sex culture has been kept very openly and preposterously. Transformation, metamorphosis, pedophilia, tentacle sex and exposure of specific body parts that are frequently appear in Japanese animation can be interpreted by ancient Japanese open sex culture like Wakashu, polygamy, sleeping in mixed sex group and pederasty. These Japanese odd sex culture is hard to find elsewhere and settled as intrinsic sexual expression in Japanese animation. This situation was institutionally severed by European Modernization's force at the end of World War II in 20th century. However, it seems they have been keeping their influence in a proper form until now. In this study, I discussed that pornographic animation should be interpreted in a frame of cultural phenomenon by researching the series of procedure that ancient Japanese open sex culture has been changed by the system. Sexuality which is found in general Japanese animation was started from their history, and the dichotomous expression about women can be understood that it is bent by institutionally regulated sexual opinion. Japanese history and culture can be understood that it is transformed to the dichotomy that are simultaneously according freedom of eroticism to the pornographic animation, and the fear and irresistible temptation about the woman's body as the other.