• Title/Summary/Keyword: Response indices

Search Result 346, Processing Time 0.024 seconds

Efficient repair of damaged FRP-reinforced geopolymeric columns using carbon fiber reinforced polymers

  • Mohamed Hechmi El Ouni;Ali Raza;Khawar Ali
    • Structural Engineering and Mechanics
    • /
    • v.87 no.6
    • /
    • pp.585-599
    • /
    • 2023
  • Geopolymer concrete (GC) can be competently utilized as a practical replacement for cement to prevent a high carbon footprint and to give a direction toward sustainable concrete construction. Moreover, previous studies mostly focused on the axial response of glass fiber reinforced polymer (glass-FRP) concrete compressive elements without determining the effectiveness of repairing them after their partial damage. The goal of this study is to assess the structural effectiveness of partially damaged GC columns that have been restored using carbon fiber reinforced polymer (carbon-FRP). Bars made of glass-FRP and helix made of glass-FRP are used to reinforce these columns. For comparative study, six of the twelve circular specimens-each measuring 300 mm×1200 mm-are reinforced with steel bars, while the other four are axially strengthened using glass-FRP bars (referred to as GSG columns). The broken columns are repaired and strengthened using carbon-FRP sheets after the specimens have been subjected to concentric and eccentric compression until a 30% loss in axial strength is attained in the post-peak phase. The study investigates the effects of various variables on important response metrics like axial strength, axial deflection, load-deflection response, stiffness index, strength index, ductility index, and damage response. These variables include concentric and eccentric compression, helix pitch, steel bars, carbon-FRP wrapping, and glass-FRP bars. Both before and after the quick repair process, these metrics are evaluated. The results of the investigation show that the axial strengths of the reconstructed SSG and GSG columns are, respectively, 15.3% and 20.9% higher than those of their original counterparts. In addition, compared to their SSG counterparts, the repaired GSG samples exhibit an improvement in average ductility indices of 2.92% and a drop in average stiffness indices of 3.2%.

Changes of Electrolytes, Hematological Indices, and Cytokines following Dietary Magnesium Deficiency in Rats

  • Moon, Seong-Min
    • Biomedical Science Letters
    • /
    • v.17 no.3
    • /
    • pp.203-209
    • /
    • 2011
  • Magnesium (Mg) plays an essential role in physiological and metabolic reactions. Recently, there has been an increased interest in the role of Mg deficiency, particularly the relationship between serum Mg value and inflammatory response. This study was designed to determine the relationship between serum Mg deficiency with inflammatory response, electrolytes and hematological alteration over long-term periods. Sixteen male Sprague-Dawley rats were divided into two groups: control (n=8), and Mg deficiency group (MgD group, n=8). Chow and normal water (tap water) were regularly provided to the control group and Mg-depleted chow and third distilled water were regularly provided for 60 days to the MgD group. Body weights, Serum Mg, $K^+$, inorganic phosphorus (IP) and total iron binding capacity (TIBC) levels in the MgD group were lower than those of the control group (P<0.05). Granulocyte fraction and MCV, RDW and PDW levels were higher, whereas lymphocyte fraction, erythrocyte, hemoglobin and MCHC levels were lower in the MgD group than in the control group (P<0.05). MCP-1 and TNF-${\alpha}$ levels in the MgD group were greater than those of the control group (P<0.05). In conclusion, the results of the present study suggest that Mg deficiency over a long-term period had not altered total leukocyte concentration in the blood, but had detrimental effects, including disturbances of electrolytes balance, disturbance of iron indices, potential anemia and elevation of pro-inflammatory cytokine. However, further studies should be performed to determine the relationship between serum Mg deficiency and major organ damage or alteration.

Characterization and modeling of near-fault pulse-like strong ground motion via damage-based critical excitation method

  • Moustafa, Abbas;Takewaki, Izuru
    • Structural Engineering and Mechanics
    • /
    • v.34 no.6
    • /
    • pp.755-778
    • /
    • 2010
  • Near-fault ground motion with directivity or fling effects is significantly influenced by the rupture mechanism and substantially different from ordinary records. This class of ground motion has large amplitude and long period, exhibits unusual response spectra shapes, possesses high PGV/PGA and PGD/PGA ratios and is best characterized in the velocity and the displacement time-histories. Such ground motion is also characterized by its energy being contained in a single or very few pulses, thus capable of causing severe damage to the structures. This paper investigates the characteristics of near-fault pulse-like ground motions and their implications on the structural responses using new proposed measures, such as, the effective frequency range, the energy rate (in time and frequency domains) and the damage indices. The paper develops also simple mathematical expressions for modeling this class of ground motion and the associated structural responses, thus eliminating numerical integration of the equations of motion. An optimization technique is also developed by using energy concepts and damage indices for modeling this class of ground motion for inelastic structures at sites having limited earthquake data.

Multiple linear regression and fuzzy linear regression based assessment of postseismic structural damage indices

  • Fani I. Gkountakou;Anaxagoras Elenas;Basil K. Papadopoulos
    • Earthquakes and Structures
    • /
    • v.24 no.6
    • /
    • pp.429-437
    • /
    • 2023
  • This paper studied the prediction of structural damage indices to buildings after earthquake occurrence using Multiple Linear Regression (MLR) and Fuzzy Linear Regression (FLR) methods. Particularly, the structural damage degree, represented by the Maximum Inter Story Drift Ratio (MISDR), is an essential factor that ensures the safety of the building. Thus, the seismic response of a steel building was evaluated, utilizing 65 seismic accelerograms as input signals. Among the several response quantities, the focus is on the MISDR, which expresses the postseismic damage status. Using MLR and FLR methods and comparing the outputs with the corresponding evaluated by nonlinear dynamic analyses, it was concluded that the FLR method had the most accurate prediction results in contrast to the MLR method. A blind prediction applying a set of another 10 artificial accelerograms also examined the model's effectiveness. The results revealed that the use of the FLR method had the smallest average percentage error level for every set of applied accelerograms, and thus it is a suitable modeling tool in earthquake engineering.

A Study on Demand Pattern Analysis for Forecasting of Customer's Electricity Demand (수요측 전력사용량 예측을 위한 수요패턴 분석 연구)

  • Ko, Jong-Min;Yang, Il-Kwon;Yu, In-Hyeob
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1342-1348
    • /
    • 2008
  • One important objective of the electricity market is to decrease the price by ensuring stability in the market operation. Interconnected to this is another objective; namely, to realize sustainable consumption of electricity by equitably distributing the effects and benefits of participating in the market among all participants of the industry. One method that can help achieve these objectives is the ^{(R)}$demand-response program, - which allows for active adjustment of the loadage from the demand side in response to the price. The demand-response program requires a customer baseline load (CBL), a criterion of calculating the success of decreases in demand. This study was conducted in order to calculate undistorted CBL by analyzing the correlations between such external or seasonal factors as temperature, humidity, and discomfort indices and the amounts of electricity consumed. The method and findings of this study are accordingly explicated.

Developing standardized dietetic staffing indices in employee foodservice by job analysis methodology (사업체 급식소 영양사 직무분석 ( 제 2 보 ) : 업무수행시간 및 적정인원산출)

  • Lee, Jin-Mi;Yang, Il-Seon;Kim, Hyeon-A;Cha, Jin-A
    • Journal of the Korean Dietetic Association
    • /
    • v.1 no.1
    • /
    • pp.79-88
    • /
    • 1995
  • The purposes of this study were to : a) investigate actual time spent and expected labor time spent on management activities, and b) develop standardized indices of dietetic staffing needs in employee foodservice. A job analysis questionnaires were developed and mailed to 65 dietitians who were members of The Korean Dietetic Association Practice Group, members with management responsibilities in employee foodservices. Completed questionnaires were received from 32 dietitians for a response rate of 49%. The questionnaire contained two parts with a total of 99 statements. Statistical data analysis was completed using the SAS programs for descriptive analysis, wilcoxon signed ranks test, wilcoxon rank sum test, and pearson correlation. The results of this study can be summarized as follows. 1. The actual time spent on management activities by dietitians in employee foodservice was 69.80 hours and expected labor time spent was 61.81 hours. And they were significantly different (p<0.05). 2. ILO allowance rate( 11%) was applied: The standardized working hours per week of dietitians working in employee foodservice with manufacturing and industrial plants, and office building were 79.61 and 64.25 respectively ; Staffing need indices were 1.81 and 1.46 respectively on the base of 44 working hours. 3. The average standardized working hours per week was 68.61 hours and staffing need indices was 1.56

  • PDF

Identification of damage states and damge indices of single box tunnel from inelastic seismic analysis (비탄성 지진 해석을 통한 박스 터널의 손상 상태 및 손상 지수 규명)

  • Park, Duhee;Lee, Tae-Hyung;Kim, Hansup;Park, Jeong-Seon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.2
    • /
    • pp.119-128
    • /
    • 2016
  • In a performance-based design, the structural safety is estimated from pre-defined damage states and corresponding damage indices. Both damage states and damage indices are well defined for above-ground structures, but very limited studies have been performed on underground structures. In this study, we define the damage states and damage indices of a cut-and-cover box tunnel which is one of typical structures used in metro systems, under a seismic excitation from a series of inelastic frame analyses. Three damage states are defined in terms of the number of plastic hinges that develop within the structure. The damage index is defined as the ratio of the elastic moment to the yield moment. Through use of the proposed index, the inelastic behavior and failure mechanism of box tunnels can be simulated and predicted through elastic analysis. In addition, the damage indices are linked to free-field shear strains. Because the free-field shear strain can be easily calculated from a 1D site response analysis, the proposed method can be readily used in practice. Further studies are needed to determine the range of shear strains and associated uncertainties for various types of tunnels and site profiles. However, the inter-linked platform of damage state - damage index - shear wave velocity - shear strain provides a novel approach for estimating the inelastic response of tunnels, and can be widely used in practice for seismic designs.

Response of Structural, Biochemical, and Physiological Vegetation Indices Measured from Field-Spectrometer and Multi-Spectral Camera Under Crop Stress Caused by Herbicide (마늘의 제초제 약해에 대한 구조적, 생화학적, 생리적 계열 식생지수 반응: 지상분광계 및 다중분광카메라를 활용하여)

  • Ryu, Jae-Hyun;Moon, Hyun-Dong;Cho, Jaeil;Lee, Kyung-do;Ahn, Ho-yong;So, Kyu-ho;Na, Sang-il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1559-1572
    • /
    • 2021
  • The response of vegetation under the crop stress condition was evaluated using structural, biochemical, and physiological vegetation indices based on unmanned aerial vehicle (UAV) images and field-spectrometer data. A high concentration of herbicide was sprayed at the different growth stages of garlic to process crop stress, the above ground dry matter of garlic at experimental area (EA) decreased about 46.2~84.5% compared to that at control area. The structural vegetation indices clearly responded to these crop damages. Spectral reflectance at near-infrared wavelength consistently decreased at EA. Most biochemical vegetation indices reflected the crop stress conditions, but the meaning of physiological vegetation indices is not clear due to the effect of vinyl mulching. The difference of the decreasing ratio of vegetation indices after the herbicide spray was 2.3% averagely in the case of structural vegetation indices and 1.3~4.1% in the case of normalization-based vegetation indices. These results meant that appropriate vegetation indices should be utilized depending on the types of crop stress and the cultivation environment and the normalization-based vegetation indices measured from the different spatial scale has the minimized difference.

Assessment of the Environmental Conditions in Patient's Houses with Allergy by Use of a Fungal Index - A Case Study (곰팡이 센서(Fungal detector)를 이용한 알러지 환자 가정의 실내 환경 평가 - 사례연구)

  • Lee, Jun-Hyup;Kim, Young-Hwan;Moon, Kyong-Whan
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.1
    • /
    • pp.27-32
    • /
    • 2010
  • The indoor environmental condition was assessed in houses with allergy (asthma and atopy) patients by use of a fungal detector. The fungal index was calculated from the growth rate of the sensor fungi in a fungal detector encapsulating the spores, Alternaria alternata S-78, Eurotium herbariorum J-183 and Aspergillus penicillioides K-712. Fungal indices were higher in asthma patient's houses than in control houses and Eurotium herbariorum showed the highest growth response among the sensor fungi. Dust mites allergen, Der f1, was also significantly high in allergy patient's houses where fungal indices above 10 were detected. A correlation was observed between the fungal indices and dust mite allergen proliferations in examined houses. Therefore, the fungal index can be a useful tool as an indirect indication for detecting chronic dampness that brings both contaminations by fungi and dust mite.

The Influence and Treatment Method of Extraneous Deformation & Unstability on the Flexural Toughness of FRC (FRC의 휨인성 평가시 외부변형과 불안정성의 영향 및 처리방안)

  • Kim, Kyoung-Soo;Kim, Nam-Wook;Lim, Jeong-Hwan;Bae, Ju-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.119-128
    • /
    • 2002
  • This study discusses the issues related to the accuracy of deflection measurement and unstable energy in the testing of FRC. Some deflection methods may include large extraneous deformations. A faulty load-deflection curve will be obtained if an unstable deflection measuring system is used, and inaccurate toughness evaluation can result from this faulty curve. Some load-deflection curve of FRC may be attributed to unstable region of the load-deflection curve. If the unstable region is not correctly evaluated toughness indices from the curve would inappropriately represent true indices. In this paper, the discussion will focus on the effects of the deflection measuring system both on the measurement of the load-deflection response of FRC and the evaluation of FRC toughness and the effects of the unstable region and the management method of unstable region on toughness evaluation of FRC. It is observed that ASTM toughness indices which is based on measured deflection at first cracking is influenced significantly by extraneous deformation of deflection measurement. Extraneous deformation in deflection measurement, however result in negligible errors in toughness evaluation if JSCE and JCI definitions are used.