• 제목/요약/키워드: Respiratory Monitoring

검색결과 293건 처리시간 0.031초

Reasons and Risk Factors for Readmission Following Hospitalization for Community-acquired Pneumonia in South Korea

  • Jang, Jong Geol;Ahn, June Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • 제83권2호
    • /
    • pp.147-156
    • /
    • 2020
  • Background: Limited studies have been performed to assess readmission following hospitalization for community-acquired pneumonia (CAP) in an Asian population. We evaluated the rates, reasons, and risk factors for 30-day readmission following hospitalization for CAP in the general adult population of Korea. Methods: We performed a retrospective observational study of 1,021 patients with CAP hospitalized at Yeungnam University from March 2012 to February 2014. The primary end point was all-cause hospital readmission within 30 days following discharge after the initial hospitalization. Hospital readmission was classified as pneumonia-related or pneumonia-unrelated readmission. Results: During the study period, 862 patients who survived to hospital discharge were eligible for inclusion and among them 72 (8.4%) were rehospitalized within 30 days. In the multivariable analysis, pneumonia-related readmission was associated with para/hemiplegia, malignancy, pneumonia severity index class ≥4 and clinical instability ≥1 at hospital discharge. Comorbidities such as chronic lung disease and chronic kidney disease, treatment failure, and decompensation of comorbidities were associated with the pneumonia-unrelated 30-day readmission rate. Conclusion: Rehospitalizations within 30 days following discharge were frequent among patients with CAP. The risk factors for pneumonia-related and -unrelated readmission were different. Aspiration prevention, discharge at the optimal time, and close monitoring of comorbidities may reduce the frequency of readmission among patients with CAP.

An Implementation of the embedded hardware system based Ultrasonic Spirometer and Improvement of Its Sensitivity (임베디드 하드웨어 시스템 기반의 초음파 폐활량계 구현 및 감도 향상 연구)

  • Lee, Cheul-Won;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.417-420
    • /
    • 2005
  • The spirometer is a medical device that measures the instantaneous velocity of the respiratory gas flow capacity. It is used for testing the condition of the lung and patient monitoring. It measures the absolute capacity difference that includes the flow capacity signal. In this paper, by using an ultrasound sensor that reduce the error caused by the inertia and pressure it has improved the transmission and receiving signal. This has enabled patients with weal respiratory to use the spirometer. Also, by using the embedded hardware system, a precise and prompt detection system was implemented.

  • PDF

A plunging ranula in a child with holoprosencephaly: a case of unique pathophysiology and difficult airway management

  • Watanabe, Takuma;Yokoyama, Atsushi;Shimizu, Satoshi;Bessho, Kazuhisa
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권4호
    • /
    • pp.232-236
    • /
    • 2022
  • A ranula is a pseudocyst that originates from the sublingual gland after trauma. Acute cases of ranulas that progress rapidly and cause respiratory distress are rare. Holoprosencephaly is a complex brain malformation caused by incomplete cleavage of the prosencephalon. Children with holoprosencephaly may experience upper airway obstruction due to the associated dentoalveolar malformations and oromotor dysfunctions. We present the case of an eight-year-old female patient with holoprosencephaly and a plunging ranula that manifested as an acute course due to difficult airway management. She required gastrostomy for oromotor dysfunctions related to feeding and swallowing and difficulty managing oral secretions. The sublingual gland and ranula were removed under general anesthesia. Postoperatively, urgent reintubation and close monitoring in the intensive care unit were required due to upper airway obstruction. We successfully managed the patient with close cooperation of a pediatrician and an anesthetist, and no recurrence was observed at the one-year follow-up. A ranula can be caused by trauma to the floor of the mouth in association with lingually inclined mandibular teeth, a type of dentoalveolar compensation seen in maxillary hypoplasia associated with holoprosencephaly. Careful consideration is needed in such cases since airway management can be difficult due to postoperative swelling and oromotor dysfunctions.

Diagnostic Approaches for Idiopathic Pulmonary Fibrosis

  • Jae Ha Lee;Jin Woo Song
    • Tuberculosis and Respiratory Diseases
    • /
    • 제87권1호
    • /
    • pp.40-51
    • /
    • 2024
  • Idiopathic pulmonary fibrosis (IPF) is a chronic, progressive, fibrosing interstitial pneumonia with a very poor prognosis. Accurate diagnosis of IPF is essential for good outcomes but remains a major medical challenge due to variability in clinical presentation and the shortcomings of existing diagnostic tests. Medical history collection is the first and most important step in the IPF diagnosis process; the clinical probability of IPF is high if the suspected patient is 60 years or older, male, and has a history of cigarette smoking. Systemic assessment for connective tissue disease is essential in the initial evaluation of patients with suspected IPF to identify potential causes of interstitial lung disease (ILD). Radiologic examination using high-resolution computed tomography plays a pivotal role in the evaluation of patients with ILD, and prone and expiratory computed tomography images can be considered. If additional tests such as surgical lung biopsy or transbronchial lung cryobiopsy are needed, transbronchial lung cryobiopsy should be considered as an alternative to surgical lung biopsy in medical centers with experience performing this procedure. Diagnosis through multidisciplinary discussion (MDD) is strongly recommended as MDD has become the cornerstone for diagnosis of IPF, and the scope of MDD has expanded to monitoring of disease progression and suggestion of appropriate treatment options.

Validation of the Korean Version of the St. George's Respiratory Questionnaire for Patients with Chronic Respiratory Disease (한국어판 세인트조지 호흡기설문의 타당도와 신뢰도 검정)

  • Kim, Young Sam;Byun, Min Kwang;Jung, Wou Young;Jeong, Jae Hee;Choi, Sang Bong;Kang, Shin Myung;Moon, Ji Ae;Han, Jung Suk;Nam, Chung-Mo;Park, Moo Suk;Kim, Se Kyu;Chang, Joon;Ahn, Chul Min;Kim, Sung Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • 제61권2호
    • /
    • pp.121-128
    • /
    • 2006
  • Background: The "health-related quality of life" (HRQL) for patients with chronic respiratory disease has been emphasized, because chronic respiratory disease (CRD) is chronic and progressive, and it finally causes disability. HRQL instruments may be useful for monitoring patients' progress or for determining the most appropriate choice of treatment. We describe the adapting St George's Respiratory Questionnaire (SGRQ), which is a self-administered questionnaire developed by Jones et al. (1991), into the Korean version for covering three domains of health for the patients suffering with airways disease. Method: We obtained the original SGRQ from the author after gaining permission. For adaptation, we created an expert panel and translated the original questionnaire into Korean language. The translated questionnaire was then back-translated by bilingual experts and we compared it with the original questionnaire. After correction and feasibility testing, 74 patients with chronic respiratory disease (COPD, asthma, destroyed lung) completed the Korean version of the SGRQ. The clinical status of each patients was evaluated concurrently with measurement of their health status. Result: The Korean version of the SGRQ was acceptable and easy to understand. Cronbach's alpha reliability coefficient was 0.92 for the overall scale and 0.63 for the "Symptoms", subscale, 0.87 for the "Activity", subscale, and 0.89 for the "Impacts" subscales. The correlation coefficients between the overall score and the Borg scale score, oxygen saturation, and forced expiratory volume in one second ($FEV_1$) were 0.52, -0.32 and -0.26, respectively. These results support that the Korean SGRQ was correlated with other measurements. Conclusion: The Korean SGRQ was reliable and valid for patients with chronic respiratory disease, such as COPD, asthma, and destroyed lung. The SGRQ score was well correlated with other respiratory measurements as well. Although further studies should complete the adaptation work, our results suggest that the SGRQ may be used in Korea and also for international studies involving Korean CRD patients.

Effect of Fabric Sensor Type and Measurement Location on Respiratory Detection Performance (직물센서의 종류와 측정 위치가 호흡 신호 검출 성능에 미치는 효과)

  • Cho, Hyun-Seung;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Hyeok-Jae;Lee, Jeong-Hwan;Kwak, Hwi-Kuen;Ko, Yun-Su;Chae, Je-Wook;Oh, Su-Hyeon;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • 제22권4호
    • /
    • pp.97-106
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the type and measurement location of a fabric strain gauge sensor on the detection performance for respiratory signals. We implemented two types of sensors to measure the respiratory signal and attached them to a band to detect the respiratory signal. Eight healthy males in their 20s were the subject of this study. They were asked to wear two respiratory bands in turns. While the subjects were measured for 30 seconds standing comfortably, the respiratory was given at 15 breaths per minute were synchronized, and then a 10-second break; subsequently, the entire measurement was repeated. Measurement locations were at the chest and abdomen. In addition, to verify the performance of respiratory measurement in the movement state, the subjects were asked to walk in place at a speed of 80 strides per minute(SPM), and the respiratory was measured using the same method mentioned earlier. Meanwhile, to acquire a reference signal, the SS5LB of BIOPAC Systems, Inc., was worn by the subjects simultaneously with the experimental sensor. The Kruskal-Wallis test and Bonferroni post hoc tests were performed using SPSS 24.0 to verify the difference in measurement performances among the group of eight combinations of sensor types, measurement locations, and movement states. In addition, the Wilcoxon test was conducted to examine whether there are differences according to sensor type, measurement location, and movement state. The results showed that the respiratory signal detection performance was the best when the respiratory was measured in the chest using the CNT-coated fabric sensor regardless of the movement state. Based on the results of this study, we will develop a chest belt-type wearable platform that can monitor the various vital signal in real time without disturbing the movements in an outdoor environment or in daily activities.

Evaluation of Chromium and Manganese Exposure in Welders and Establishment of Efficient Preventive Measures for Fume Exposure (철강용접자의 크롬 및 망간 노출평가와 산업위생관리 대책에 관한 연구)

  • Lee, Young-Sei;Yoon, Chong-Guk;Park, Jong-An;Lee, Song-Kwon;Chae, Jong-Hong;Kim, Ek-Soo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제10권1호
    • /
    • pp.45-57
    • /
    • 2000
  • Results of environmental monitoring for 35 steel industry welders exposed to manganese and chromium fume were evaluated. Efficiency of respiratory protectors, welding face shields and local exhaust ventilation were also evaluated to establish more efficient preventive measures that can protect welders from occupational disease as related to welding fume. The results are as follows; 1. Total fume from $CO_2$ arc welding with mild steel occurred 1.5 to 2.2 times more than that from shielded metal arc welding. Chromium and nickel fume from welding with stainless steel occurred 27 to 59 times and 18 to 30 times, respectively, than those with mild steel. 2. Proportions of water-soluble chromium(VI) and insoluble chromium(VI) Compare to total chromium occurring from $CO_2$ arc welding with stainless steel were 10.5% and 8.7%, respectively, while those with mild steel were 57.1 to 63.2% and 31.6 to 38.1%, respectively. 3. The efficiencies of 4 types of respiratory protectors to reduce welding fume exposure were evaluated as 54.4 to 64.4%. 4. The reducing effect of head type welding face shield was 67.6%, and that of hand type welding face shield was 58.5%. The highest reducing effect was shown in air supply welding face shield as 99.2%, although it is not convenient to wear. 5. When welding face shield and respiratory protectors were worn together, the reducing efficiency increased to 79.0 to 87.5%. 6. When local exhaust ventilation was installed in workplace, the reducing efficiencies varied from 31.5 to 73.1% according to the types of welding.

  • PDF

Monitoring of Respiration and Soluble Carbohydrate Changes in Mushrooms Following ${\gamma}$-Irradiation (전리에너지가 버섯의 호흡과 당에 미치는 영향)

  • Yoon, Hyung Sik;Kwon, Joong Ho
    • Current Research on Agriculture and Life Sciences
    • /
    • 제8권
    • /
    • pp.89-94
    • /
    • 1990
  • Respiration and soluble carbohydrates of stored mushrooms (Agaricus bisporus) were determined to be associated with physiological and biochemical changes induced by ionizing radiation treatment which was applied for extending the shelf-life. Immediately after gamma irradiation at 1 to 3 kGy, the respiratory rate of mushrooms increased linearly with increasing doses of irradiation, and then it normarized after 2 days of storage at $9{\pm}1^{\circ}C$ and $80{\pm}7%$ RH. In the nonirradiated mushrooms, the respiratory peak was observed at around 5 to 6 days after storage, while irradiation treatment not only reduced respiratory activities of stored mushrooms, but prolonged the peak development. Moisture content and dry matter of mushrooms packaged in a paper box and polyethylene film were relatively constant during the storage for 20 days and the reducing sugar contents decreased significantly after 5 days of storage(p<0.01). Free sugars of mushroom pilei, which consisted of mannitol, trehalose and glucose, also markedly decreased at the earlier part of the storage period and thereafter, 2 kGy irradiation resulted in the reduction of their changes.

  • PDF

Respiratory Air Flow Transducer Applicable to Cardiopulmonary Resuscitation Procedure (인공심폐소생술에 활용 가능한 호흡기류센서)

  • Kim, Kyung-Ah;Lee, In-Kwang;Lee, You-Mi;Yu, Hee;Kim, Young-Il;Han, Sang-Hyun;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제62권6호
    • /
    • pp.833-839
    • /
    • 2013
  • Cardiopulmonary resuscitation (CPR) is performed by thoracic compression and artificial ventilation for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are facing the whole area perpendicular to the flow axis. The present study developed a new air flow transducer conveniently applicable to CPR. Specially designed "sensing rod" samples the air velocity at 3 different locations of the flow cross-section, then transforms into average dynamic pressure by the Bernoulli's law. The symmetric structure of the sensing holes of the sensing rod enables bi-directional measurement simply by taking the difference in pressure by a commercial differential pressure transducer. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

Analysis of Decision-Making Situations and Alternatives for Clinical Nurses in a University Hospital (일 대학 병원 임상간호사의 의사결정상황과 대안에 관한 분석)

  • Kim, Myung-Hee;Choi, Won-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • 제10권4호
    • /
    • pp.449-457
    • /
    • 2004
  • Purpose: This study seeks to identify situations where nurses are required to consider alternatives, for the delivery of nursing care, appropriate to the needs of a medical care unit, surgical care unit, and intensive care unit in a university hospital. Method: Data was collected from 100 nurses using an open questionnaire, during a one week period in May, 2003. These nurses all had at least two years of experience within a medical care unit, surgical care unit, or intensive care unit at a university hospital. Results: The situations that nurses typically faced were categorized into 21 problems for nurses including : respiratory problems(26.8%), pain(23.6%), problems in relation to bowel habit(23.2%). In cases where nurses were faced with making decisions in relation to solving respiratory problems, the alternatives included ; applying oxygen(29.3%), physical assessment and monitoring(14.7%), refining and modifying order and suggestion order(9.3%). Ventilator care(9.3%), was chosen to solve pain problems ; doing pm orders(30.3%), placebo medication(27.3%), and to refine and modify orders and suggestions(18.2%). To solve problems in relation to bowel habits ; enemas accounted for 32.3%, and laxative medication 30.8%. Conclusion: To improve the quality of nursing, the outcome of nursing care associated with 21 problems for nurses including : respiratory problems, pain, and problems in relation to bowel habit, should be identified and the best alternative nursing care should be developed.

  • PDF