• 제목/요약/키워드: Respiratory Monitoring

검색결과 292건 처리시간 0.022초

Review of Internet of Things-Based Artificial Intelligence Analysis Method through Real-Time Indoor Air Quality and Health Effect Monitoring: Focusing on Indoor Air Pollution That Are Harmful to the Respiratory Organ

  • Eunmi Mun;Jaehyuk Cho
    • Tuberculosis and Respiratory Diseases
    • /
    • 제86권1호
    • /
    • pp.23-32
    • /
    • 2023
  • Everyone is aware that air and environmental pollutants are harmful to health. Among them, indoor air quality directly affects physical health, such as respiratory rather than outdoor air. However, studies that have examined the correlation between environmental and health information have been conducted with public data targeting large cohorts, and studies with real-time data analysis are insufficient. Therefore, this research explores the research with an indoor air quality monitoring (AQM) system based on developing environmental detection sensors and the internet of things to collect, monitor, and analyze environmental and health data from various data sources in real-time. It explores the usage of wearable devices for health monitoring systems. In addition, the availability of big data and artificial intelligence analysis and prediction has increased, investigating algorithmic studies for accurate prediction of hazardous environments and health impacts. Regarding health effects, techniques to prevent respiratory and related diseases were reviewed.

재발성 호흡기 증상을 동반한 병적 위식도 역류 질환에서 이중 채널 식도내 pH 검사의 의의 (Clinical Significance of Dual-probe Esophageal pH Monitoring in Pathological Gastroesophageal Reflux Disease with Recurrent Respiratory Symptoms)

  • 최윤창;문경래
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제6권1호
    • /
    • pp.17-23
    • /
    • 2003
  • 목 적: 24시간 이 중 채널 식도 pH 검사를 하여 위식도 역류와 호흡기 증상과의 상호 관계를 알아보고 호흡기 증상이 있는 역류 환자에서 원위부와 근위부 식도 pH 측정치를 비교하고자 연구하였다. 방 법: 1998년 8월부터 2002년 8월까지 조선대학교병원 소아과에 위식도 역류의 증상이 있거나 3주일 이상의 만성 기침 등 잦은 호흡기 증상이 있어 식도 pH 검사를 실시한 34명 중 원위부 식도에서 병적인 역류를 보인 17명을 대상으로 하였다. 병적 역류의 기준은 95백분위수 이상의 역류지표 (reflux index)를 병적 역류로 정의하였다. 결 과: 1) 대상 34명에서 호흡기 증상이 있는 16명 중 12명(75%), 호흡기 증상이 없는 18명 중 5명(28%)에서 원위부 식도에서 병적 역류를 보였다. 2) I군에서 근위부와 원위부의 역류 지수, 총 역류횟수, 5분 이상 지속된 역류의 횟수, 최장 역류 시간 등 모든 항목들이 유의한 차이를 보였다(P<0.05). 3) II군에서 근위부와 원위부의 최장 역류 시간을 제외한 모든 항목들이 유의한 차이가 없었다(P>0.1). 4) 근위부 식도에서 I군과 II군의 모든 항목들이 유의한 차이가 없었다(P>0.5). 결 론: 원위부 위식도 역류를 보이는 환자에서 호흡기 증상의 유무에 따라 근위부 식도 pH 검사 결과의 모든 항목에서 차이를 보이지 않아 재발성 호흡기 증상을 보이는 환자에서 이중채널 식도 pH검사의 유용성에 대해 재고가 필요할 것으로 판단된다.

  • PDF

도플러 레이더와 에어 매트리스를 이용한 무구속 방식의 신생아 감시 장치 설계 (Design of Unconstrained Baby Monitoring System Based on a Doppler Radar and an Air Mattress)

  • 양성수;조성필;박호동;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.177-184
    • /
    • 2014
  • Continuous monitoring of heart rates and respiratory rates for newborns or infants is very important since the abnormal breathing and heart problems can threaten the life of newborns or infants. A noncontact baby monitoring system based on a Doppler radar and an air mattress was designed. The Doppler radar was used to acquire respiratory signals and the air mattress was employed to obtain heart rates. The performance of the designed system was evaluated using a commercialized infant simulator ($Simbaby^{TM}$) and a respiration belt transducer was used to measure respiration rates as a reference. Results for respiratory rates revealed that the correlation coefficients between I-and Q-channel and the respiration belt were 0.84 and 0.91 and the mean ${\pm}$ standard deviations of errors between them were $1.66{\pm}1.92$ (bpm) and $0.88{\pm}1.65$ (bpm). Heart rates showed that the correlation coefficient between air mattress and set value of the simulator was 0.73 and the mean ${\pm}$ standard deviation of errors between them was $1.09{\pm}3.45$ (bpm). These results indicate that the designed system holds the potential as an effective monitoring tool for continuous monitoring heart rates and respiratory rates of newborns or infants.

The effect of dental scaling noise during intravenous sedation on acoustic respiration rate (RRaTM)

  • Kim, Jung Ho;Chi, Seong In;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제18권2호
    • /
    • pp.97-103
    • /
    • 2018
  • Background: Respiration monitoring is necessary during sedation for dental treatment. Recently, acoustic respiration rate ($RRa^{TM}$), an acoustics-based respiration monitoring method, has been used in addition to auscultation or capnography. The accuracy of this method may be compromised in an environment with excessive noise. This study evaluated whether noise from the ultrasonic scaler affects the performance of RRa in respiratory rate measurement. Methods: We analyzed data from 49 volunteers who underwent scaling under intravenous sedation. Clinical tests were divided into preparation, sedation, and scaling periods; respiratory rate was measured at 2-s intervals for 3 min in each period. Missing values ratios of the RRa during each period were measuerd; correlation analysis and Bland-Altman analysis were performed on respiratory rates measured by RRa and capnogram. Results: Respective missing values ratio from RRa were 5.62%, 8.03%, and 23.95% in the preparation, sedation, and scaling periods, indicating an increased missing values ratio in the scaling period (P < 0.001). Correlation coefficients of the respiratory rate, measured with two different methods, were 0.692, 0.677, and 0.562 in each respective period. Mean capnography-RRa biases in Bland-Altman analyses were -0.03, -0.27, and -0.61 in each respective period (P < 0.001); limits of agreement were -4.84-4.45, -4.89-4.15, and -6.18-4.95 (P < 0.001). Conclusions: The probability of missing respiratory rate values was higher during scaling when RRa was used for measurement. Therefore, the use of RRa alone for respiration monitoring during ultrasonic scaling may not be safe.

A New Measure for Assessing the Public Health Response to a Middle East Respiratory Syndrome Coronavirus Outbreak

  • Cho, Sung-il
    • Journal of Preventive Medicine and Public Health
    • /
    • 제48권6호
    • /
    • pp.277-279
    • /
    • 2015
  • Contact monitoring is an essential component of the public health response to a Middle East respiratory syndrome coronavirus outbreak, and is required for an effective quarantine to contain the epidemic. The timeliness of a quarantine is associated with its effectiveness. This paper provides a conceptual framework to describe the process of contact monitoring, and proposes a new measure called the "timely quarantined proportion" as a tool to assess the adequacy of a public health response.

환자 감시장치의 국산화 개발에 관한 연구 (A Study on the Development of Patient Monitoring System)

  • 홍승홍;김재현
    • 대한의용생체공학회:의공학회지
    • /
    • 제2권2호
    • /
    • pp.117-126
    • /
    • 1981
  • Patient monitoring system, which is one of widly used medical electronic equipment in clinics, is developed. This prototype bedside monitor is considered that can measure electrocardiograph, photoplethysmograph, heart rate, respiratory, body temperature, and etc. Some clinical tests are performed and considered with its usefulness for patient monitoring items.

  • PDF

위식도 역류에 대한 후두인두부에서 산도 검사의 의의 (Clinical Significance of Hypopharyngeal pH Monitoring in Gastroesophageal Reflux)

  • 정다운;김소희;김은영;문경래
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제8권2호
    • /
    • pp.143-149
    • /
    • 2005
  • 목 적: 병적 위식도 역류 환자에서 후두인두부 산도를 검사하여 후두인두부 역류와 호흡기 증상과의 상관관계를 연구하고자 하였다. 방 법: 2003년 2월부터 2004년 9월까지 잦은 구토 등 위식도 역류가 의심되는 증상이 있거나 만성 재발성 호흡기 증상이 있어 24시간 후두인두부와 식도에서 산도 검사를 실시한 39명 중 병적 위식도 역류를 보인 29명을 대상으로 하였다. 병적 위식도 역류의 기준은 95백분위수 이상 역류 지표를 병적 역 류로 정의하였고, 후두부 인두 산 역류의 기준은 식도에서 pH 4 이하로 떨어짐과 동시에 후두부 인두에서 pH가 4 이하로 떨어지는 것으로 정의하였다. 결 과: 1. 산도 검사를 실시한 39명에서 호흡기 증상이 있는 7명 중 6명(86.%), 호흡기 증상이 없는 32명 중 23명(72%)에서 병적 위식도 역류를 보였다. 2. 호흡기 증상으로는 반복되는 폐렴 2명, 크룹 1명, 후두연화증 1명, 천식 2명 등이었다. 3. 호흡기 증상을 동반한 병적 역류군에서 후두인두부와 식도의 역류 지표를 비교하면 5분 이상 지속된 역류의 횟수 제외한 역류 지수, 총 역류 횟수, 최 장 역류 시간 등에서 통계학적으로 의의있는 차이를 보였다. 4. 호흡기 증상을 동반하지 않은 병적 역류군에서 후두인두부와 식도의 모든 역류 지표들이 유의한 차이를 보였다. 5. 식도에서 호흡기 증상을 동반한 병적 역류군과 호흡기 증상을 동반하지 않은 병적 역류군의 역류지표를 비교하면 총 역류 횟수를 제외한 역류 지수, 최장 역류 시간, 5분 이상 지속된 역류의 횟수에서 통계학적 의의가 없었다. 6. 후두부 인두에서 호흡기 증상을 동반한 병적 역류군과 호흡기 증상을 동반하지 않은 병적 역류군의 역류 지표를 비교하면 모든 항목에서 통계학적 의의가 없었다. 결 론: 병적 위식도 역류 환자에서 호흡기 증상 유무와 관계없이 후두인두부의 산도 검사 결과는 통계학적 의의가 없으므로 만성 호흡기 질환에서 후두인두부 역류와의 상관관계의 규명에 후두인두부 산도 검사의 유용성에 대한 재고가 필요하다.

  • PDF

환자감시를 위한 모듈형 호흡 시스템의 구현 (The implementation of modular respiratory system for patient monitoring)

  • 박종억;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.503-506
    • /
    • 2001
  • 심전도 감시장치(electro-cardiography monitoring system)에 대한 연구는 국내외적으로 활발하게 이루어지고 있으나, 국내의 경우 환자 상태를 감시하는데 있어 중요한 요소인 호흡(respiration)에 관한 연구는 다소 미흡한 민이 있었다. 이번 연구는 환자의 상태를 감시하는데 있어 심전도, 혈압(brood pressure), 체온(temperature)과 더불어 중요한 요소로 여겨지는 호흡에 대한 감시장치로, 호흡 시 신체의 임피던스 변화를 이용하여 시스템을 구현함으로써, 심전도 측정과 병행하여 사용할 수 있는 장점이 있다. 특히, 임피던스를 이용한 환자감시장치의 경우 중추신경 마비 둥의 원인에 의한 무호흡 감지에 효과적으로 응급실 등에서 유용하게 사용된다. 구현된 시스템은 아날로그 부와 디지털 부의 잡음간섭 린 환자의 안전을 도모하기 위해 회로를 전기적으로 분리하여 설계하였다. 아날로그 부의 구성은 고주파 신호를 발생하는 정현파 발생부, 반송파로부터 인체의 임피던스 변화성분을 추출하고 증폭하는 증폭부, 기저대역으로 변환하기 위한 복조 및 아날로그 필터부로 구성되어 있다. 디지털 부는 아날로그-디지탈 변환기 및 디지털 필터, 생체정보 추출부로 구성되어있다. 본 연구에서 구현된 시스템은 심전도 감시장치의 전극을 공용으로 사용할 수 있도록 구성되었으며, 호흡 감시장치에 대한 기반기술 획득을 통해 다기능환자감시장치의 개발에 바로 응용 될 수 있다.

  • PDF

인체에서 맥파전달시간을 이용한 호흡노력 모니터링 (Respiratory Effort Monitoring Using Pulse Transit Time in Human)

  • 정동근
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권6호
    • /
    • pp.485-489
    • /
    • 2002
  • 본 연구는 동맥의 압력에 따라 변하는 맥파전달시간(pulse transit time, PTT)을 이용하여 호흡노력을 검출하기 위하여 호흡에 따른 PTT 변화를 관찰하였다. PTT는 심전도의 R파 피크로부터 말초에서 나타나는 광전용적맥(photoplethysmograph, PPG)의 최대기울기점까지 시간이다. 생체 신호를 아날로그-디지탈 변환하여 PC에서 매번 심장주기마다 PTT를 측정하였으며 이산적인 결과를 스플라인 보간법을 사용하여 그래프로 제시하였다. 소프트웨어는 $C^{++}$을 사용하여 windows 환경에서 운용하였다. 안정상태 호흡 시에는 호흡의 주기와 일치하는 주기적인 PTT의 변화가 있었다. 호흡 심도를 증가시킴에 따라 PTT의 진폭이 증가하였으며, 기도저항을 증가시킨 경우에도 PTT의 진폭이 증가하는 양상을 보였다. 이러한 결과는 PTT가 호흡노력에 따라 반응하는 것을 시사한다. 아울러 PTT를 이용한 호흡노력 모니터링은 비침습적 방법으로써 호흡장애를 감시하는데 유용하게 사용될 수 있음을 시사한다.

신경계 중환자실에서 기계호흡 그래프 파형 감시와 분석 (Monitoring and Interpretation of Mechanical Ventilator Waveform in the Neuro-Intensive Care Unit)

  • 박진
    • 대한신경집중치료학회지
    • /
    • 제11권2호
    • /
    • pp.63-70
    • /
    • 2018
  • Management of mechanical ventilation is essential for patients with neuro-critical illnesses who may also have impairment of airways, lungs, respiratory muscles, and respiratory drive. However, balancing the approach to mechanical ventilation in the intensive care unit (ICU) with the need to prevent additional lung and brain injury, is challenging to intensivists. Lung protective ventilation strategies should be modified and applied to neuro-critically ill patients to maintain normocapnia and proper positive end expiratory pressure in the setting of neurological closed monitoring. Understanding the various parameters and graphic waveforms of the mechanical ventilator can provide information about the respiratory target, including appropriate tidal volume, airway pressure, and synchrony between patient and ventilator, especially in patients with neurological dysfunction due to irregularity of spontaneous respiration. Several types of asynchrony occur during mechanical ventilation, including trigger, flow, and termination asynchrony. This review aims to present the basic interpretation of mechanical ventilator waveforms and utilization of waveforms in various clinical situations in the neuro-ICU.