• Title/Summary/Keyword: Respirator filter

Search Result 7, Processing Time 0.021 seconds

Performance of Respirator Filters Using Quality Factor (qF) (양질계수(Quality Factor)를 이용한 방진마스크 필터의 성능평가)

  • Han, Don-Hee;Jeong, Yoon-Sok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.170-178
    • /
    • 2000
  • Most of manufacturers try to produce the most efficient filter for respirators with the lowest breathing resistance. Filter performance depends on low penetration, i.e., high efficiency (%), and low pressure drop ($mmH_2O$). This study was performed to evaluate performance of respirator filters by quality factor ($q_F$) and suggest the direction for improvement of respirator filters of good quality in Korea. Two mechanical filters, S and K made in Korea, three filtering facepieces, S made in China, C made in Korea and M made in USA, which were widely used in the workplace, were selected and tested efficiency and pressure drop in accordance with flow rate, using with Automated Filter Tester Model 8110 (TSI, USA). The best quality factor within the same respirator filter categories was $0.0672cm^{-1}\;H_2O$ for mechanical filter S, $0.0698cm^{-1}\;H_2O$ for filtering facepiece M at flow rate of 32Lpm. Mechanical filter S would be the best suitable during heavy work since qulity factors decrease less sharply than any others as increased flow rates. It was necessary for mechanical filter S to lower pressure drop without increasing efficiency, but mechanical filter K should be increased efficiency and decreased pressure drop. While filtering facepiece M had the best quality performance of three ones, Sand C should get much higher efficiency and lower pressure for better performance.

  • PDF

Filtration efficiency and Manikin-based Total Inward Leakage Study of Particle Filtering Mask Challenged with Silver Nanoparticles (은나노입자에 대한 방진마스크 포집효율 및 총누설율)

  • Kim, Jong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.367-376
    • /
    • 2016
  • Objectives: The production and use of nanoparticles have been increased. In 2014 Workplace Survey Results, 335 companies produce and treat nanoparticls. However, lack of data on nano-toxicity and a method for risk management and regulation on nanoparticles and the standard test method are not sufficient. Protective equipment selection guidelines for nanoparticles are not established. It is required to carry out respirator efficiency test against nanoparticles. This study was performed to evaluate filtration efficiency and manikin-based total inward leakage of particle filtering mask using in Korean country challenged with silver nanoparticles. Methods: We investigated filtration efficiency and total inward leakage of 7 respirator with silver nanoparticle. Results: The geometric mean diameters of Silver nanoparticles were 30 nm and number concentration were about $10^6{\sharp}/cm^3$. Filtration efficiency of six of the seven particle filtering masks was more than 98% and one particle filtering masks filtration efficiency was 94.9%. The filtration efficiency of particle filtering masks to 20 nm silver nanoparticels was highest. Artificial breathing machine with manikin based total inward leakage were 7.6% ~ 42.3%. Conclusions: The results of this study nano-silver filter efficiency was high but the total inward leakage was higher than filter penetration. Therefore, education on how to wear a respirator should be demanded. Especially for workers handling nanoparticles and toxic material, user seal checking and fit test must be performed.

Protection against Aerosols by particulate Respirators and Fit Performance (방진마스크의 에어졸 방어효과와 밀착정도)

  • 한돈희
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.30-36
    • /
    • 2001
  • This review begins with a brief expression of aerosol capture mechanism of fibrous filter(s) and performance of particulate removing respirators. The more complicated and detailed discussion is not included in this articles. Filtration efficiency and pressure drop are introduced as quality factor ( $q_{F}$) and the way in which filtration efficiency varies with particle size is discussed. Quality factors fro filters recently certified in USA were found to be very higher than those of filters made in Korea, China and USA filters certified with old certified standards. Electrically charged filters are widely used because they have high filtration efficiency and low pressure drop, but their efficiency decreases sharply at the condition occurring wet and oil mist. A discussion is given of respirator leakage through face seal and filter media with fit testing and total inward leakage testing. Since fit factor (FF) refers to the reciprocal of the fraction of the total air entering a respirator through face seal leakage , the degree of fitting performance for respirators is expected with FF. Because respirators made in Korea had generally lower FFs than respirators made in USA, it is necessary to develope respirators that fit properly for Koreans or establish regulations for fit testing.g.

  • PDF

Fractional efficiency of Nanomaterials for the High efficiency respiratory filters (고효율 호흡보호구의 나노물질 입경별 제거 효율)

  • Lee, Gwang-Jae;Ji, Jun-Ho;Kim, Won-Geun;Yook, Se-Jin;Kim, Jong-Kyo;Kim, Jung-Ho
    • Particle and aerosol research
    • /
    • v.12 no.3
    • /
    • pp.95-102
    • /
    • 2016
  • Controlling exposures to occupational hazards is important for protecting workers. Certified facepiece respirators are recommended when engineering controls do not adequately prevent exposures to airborne nanomaterials. The objective of this study is to carry out the experimental performance test to investigate the fractional efficiencies of the filter media for two grades of facepiece respirators. Experimental performance evaluations were carried out for the test NaCl particles and silver nanoparticles. For media of respirator filter, the penetration of NaCl particles was less than 5% and the most penetrating particle size occurred at about 40 nm. For silver nanoparticles, the most penetrating particle size was about 20nm with higher efficiency than those of NaCl particles. Charge characteristics of airborne nanoparticles is important because the media of respirator filter is made by the electret filter media.

Evaluation of the Relationship between Filter Replacement and Filter Performance Change in Particulate Respirators (방진 마스크 필터 교체와 성능 변화의 상관성 조사)

  • Lee, Heonyung;Park, Jihoon;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.283-290
    • /
    • 2017
  • Objectives: This study aimed to evaluate the relationship between filter replacement and filter performance change in particulate filters used in the workplace. Methods: Three types of particulate respirator filters are mainly used in the workplaces. These were tested against the filter performance safety certification standard for dust masks established by the Ministry of Employment and Labor(MoEL). Used filters were collected to test their performance, such as filter pressure drop, efficiency, and quality factors. All these factors were evaluated by a filter tester. To compare filter performance between used and new ones, the same kinds of new filters were also tested together under the same procedures. Results: A total of 270 used filters were collected for testing. The main reasons to replace the filters were difficulty in breathing(46.2%), dirty/odor influx(19.7%), and a combination of factors(26.7%). The pressure drop for two special class groups was significantly different(new filters: $20.72{\pm}3.33mmH_2O$; used filters: $24.70{\pm}5.26mmH_2O$, p<0.0001). In the case of penetration, new filter groups indicated $0.0032{\pm}0.0040%$, while that of the used filters was $0.0596{\pm}0.1187%$. The quality factor for the used filters($0.34{\pm}0.09$) significantly decreased compared to the new filters($0.53{\pm}0.08$) (p<0.0001). Conclusions: Filter performance including pressure drop, penetration, and the quality factor was evaluated and compared between new and used filters in the workplace. The results showed that general filter performance deteriorated more for change of pressure drop, penetration and the quality factor.

Reliability on Banana Oil Qualitative Fit Test for Quarter Mask (1/4 형 마스크에 대한 Banana Oil 밀착도 검사(QLFT)의 신뢰성)

  • Han, Don-Hee;Jeong, Yoon-Sok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.79-89
    • /
    • 1999
  • A quantitative fit test, condensation nuclei counting (Portacount 8025, TSI), was performed concurrently with a banana oil (isoamyl acetate: IAA) qualitative fit test (MSA) to evaluate reliability on IAA QLFT and correlation between two methods. One brands of quarter mask (3M model 7500 medium) was prepared for QLFT with HEPA filter and gas & vapor removing media, i.e., combination cartridge. 110 subjects (65 male, 45 female) were fit tested QNFT and QLFT each three times. For a wearer combination having a FF<10, as determined by CNC QNFT, the point es timate (${\beta}$-error) of the probability of that combination not being rejected by the banana oil QLFT was found to be 0.0 with 95% confidence that this statistic is not expected to exceed 0.15. For a wearer combination having a FF<100, as determined by CNC QNFT, the point estimate of the probability of that combination not being rejected by the banana oil QLFT was found to be 0.07 with 95% confidence that this statistic is not expected to exceed 0.13. The uncertainty associated with each estimate, however, is large due to the small number of study subjects with inadequately fitting respirators.

  • PDF

The Selter Selection Plan due to Formaldehyde Leakage (포름알데히드 누출에 따른 대피장소 선정 방안)

  • SeungJu Oh;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.117-129
    • /
    • 2023
  • This study tested the effect on the toxicity of formaldehyde to select a shelter site due to formaldehyde leakage. As a result of the experiment, the range of ERPG-2 and 3 is between 2.2km and 9.6km, ASET is 6 minutes at 1km, 15 minutes at 3km, 22 minutes at 5km, and the lethality rate is 99.9% at 1km and 9% at 3km. In areas where refuge time is less than 15 minutes or the lethality rate is more than 2%, a shelter is installed. This is because if there are only a few evacuees, the evacuation time may take longer than the pre-movement time of 15 minutes or less specified in PD 7974-6:2004, and the lethality rate with the lowest number of deaths was calculated to be 2%. The shelter must be equipped with a hepa-filter, positive pressure equipment, air purifier, air respirator, goggles, chemical protective clothing type 4 and sufficient parking space must be secured to ensure the safety of evacuees.