• Title/Summary/Keyword: Respiration detection system

Search Result 51, Processing Time 0.024 seconds

Miniaturized Sensor Interface Circuit for Respiration Detection System (호흡 검출 시스템을 위한 초소형 센서 인터페이스 회로)

  • Jo, Sung-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.8
    • /
    • pp.1130-1133
    • /
    • 2021
  • In this paper, a miniaturized sensor interface circuit for the respiration detection system is proposed. Respiratory diagnosis is one of the main ways to predict various diseases. The proposed system consists of respiration detection sensor, temperature sensor, and interface circuits. Electrochemical type gas sensor using solid electrolytes is adopted for respiration detection. Proposed system performs sensing, amplification, analog-to-digital conversion, digital signal processing, and i2c communication. And also proposed system has a small form factor and low-cost characteristics through optimization and miniaturization of the circuit structure. Moreover, technique for sensor degradation compensation is introduced to obtain high accuracy. The size of proposed system is about 1.36 cm2.

A STUDY ON PULSE RATE SYSTEM

  • Kim, H. K.;S. C. Han;K. K. Min;W. Huh
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.535-537
    • /
    • 1998
  • In this paper, we devised a pulse rate detection system to provide basic clinical index of cold-hot diagnosis of oriental medicine. The system consists of pulse signal detection, respiration signal detection, electrocardiograph detection, A/D conversion and computer system parts. We define a pulse rate by a pulse count to the respiration period inspiration pulse rate by a pulse count to the inspiration period, and expiration pulse rate by a pulse count to the expiration period. The clinical experiments for normal Person to evaluate the pulse rate detection system show the pulse/respiration ratio of 4.30${\pm}$1.03, the pulse/inspiration ratio of 1.60${\pm}$0.32, the pulse/expiration ratio of 2.37${\pm}$0.75.

  • PDF

Sleep Management Pillow System (수면 관리 베개 시스템)

  • Ahn, Dohyun;Tran, Minh;Park, Jaehee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.212-217
    • /
    • 2019
  • In this paper, a sleep management pillow system for snoring detection and respiration measurement is investigated. The sleep management pillow system consists of four force sensing resistor(FSR) sensors, two microphones(MIC), a pillow, a measurement system. Four FSR sensors attached at the bottom part of the pillow are used for respiration measurement and snoring detection. Two microphones located at the middle left and right of the pillow are utilized for only snoring detection. The respiration and the snoring of ten young people were measured using the sleep management pillow system composed of a data acquisition board, interface circuit, and personal computer. The measurement accuracy of the respiration was about 98% and the measurement accuracy of the snoring was about 97%. The experiment results show that the sleep management pillow system can be used for snoring detection and respiration rate measurement during sleeping.

Respiration Detection Method Using the PPG Signal Pattern (광용적맥파의 신호 패턴을 이용한 호흡 검출 기법)

  • Park, Moon Su;Kim, Jeong Goo
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.11
    • /
    • pp.1862-1870
    • /
    • 2016
  • A respiration is one of the most useful techniques for vital checking and an abnormal respiration is often the earliest sign of critical illness. Detection of respiration is based on the photo-plethysmography (PPG) with photodiode technique. Because PPG sensor using photodiode can be easily miniaturized, it is suitable for wearable devices. A system to measure respiration rate based on PPG signal is implemented and for a reliable measurement an improved algorithm in accuracy using PPG signal pattern is proposed in this paper. As results regarding to three types of respirations (regular interval, free interval, and weak respiration) the proposed algorithm showed error rate of 0.047, 0.067, and 0.122 respectively.

Breathing Measurement and Sleep Apnea Detection Experiment and Analysis using Piezoelectric Sensor

  • Cho, Seokhyang;Cho, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.11
    • /
    • pp.17-23
    • /
    • 2017
  • In this paper, we implemented a respiration measurement system consisting of piezoelectric sensor, respiration signal processing device, and a viewer on a notebook. We tried an experiment for measuring respiration and detecting sleep apnea syndrome when a subject lay on a bed. We applied the respiration measurement algorithm to sensor data obtained from four subjects. In order to get a good graph shape, data manipulation methods such as moving averages and maximum values were applied. The window size for moving average was chosen as N=70, and the threshold value for each subject was customized. In this case, the proposed system showed 96.0% accuracy. When the maximum value among 90 data was applied instead of moving average, our system achieved 95.1% accuracy. In an experiment for detecting sleep apnea syndrome, the system showed that sleep apnea occurred correctly and calculated the average interval of sleep apnea. While infants or the elderly as well as patients with sleep apnea syndrome are lying down on a bed, our results are also expected to be able to cope with some accidental emergency situation by observing their respiration and detecting sleep apnea.

A Study of Noncontact Heartbeat and Respiration Detection Using the Doppler Radar (도플러 레이더를 이용한 비접촉 방식의 심박 및 호흡 검출에 관한 연구)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Yun-Soo;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • In this paper, a 2.4 GHz doppler radar system consisting of a doppler radar sensor and a baseband module were designed to detect heart beat and respiration signal without direct skin contact. The doppler radar system emits RF signal of 2.4 GHz toward human chest, and then detects phase modulation of the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from I/Q channels of the doppler radar system are applied to the pre-processing circuit, the amplification circuit, and the offset circuit of the baseband module. The designed system was tested on mouse, rabbit and mankind, which have different range of heart rates and respiration signals, to evaluate detection accuracy of the system. ECG acquisition system and respiration transducer were used to generate the reference signal. In our experiments, a performance of detection were found to be high in the case that the subject stays still. In this paper, we confirmed that non-contact heart beat and respiration detection using the doppler radar has the possibility and limitation according to distance, cardiopulmonary activities, range of heart rates and respiration.

Heart beat and Respiration Detection Performance of CW radar Based on New Signal Model (새로운 신호모델에 의한 CW 레이다 심장박동 및 호흡검출 성능분석)

  • Lee, Byung-Seub
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.28-33
    • /
    • 2017
  • In this paper, new signal model for bio-signal detection, i.e heart beat and respiration, using CW radar. Most research on this similar topic are based on the conventional signal model which is not correct in envisaging reflected signal from the human body. The system developed based on this conventional model can not predict exact performance of the system. So in this paper modified signal model for bio-radar is proposed and then simulation for detecting heartbeat and respiration signal in AWGN, multipath environment. The detection performance difference between two signal models are discussed.the modified

A pressure sensor system for detecting driver's drowsiness based on the respiration Paper Template for the KITS Review (호흡기반 운전자 졸음 감지를 위한 압력센서 시스템)

  • Kim, Jaewoo;Park, Jaehee;Lee, Jaecheon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.2
    • /
    • pp.45-51
    • /
    • 2013
  • In this paper, a driver's drowsy detection sensor system based on the respiration is investigated. The sensor system consists of a piezoelectric pressure sensor attached at the abdominal region of the seat belt and a personal computer. The piezoelectric pressure sensor was utilized for the measurement of pressure variations induced by the movement of the driver abdomen during breathing. The signal processing software for detecting driver's drowsiness was produced using the Labview. The experiments were performed with 30 years male driver. The amplitude of the respiration at awake state was larger than one at the drowsy state. On the contrary, the respiration rate at awake state was lower than one at the drowsy state. The drowsy detection sensor system developed based on the experimental could successfully detect the driver's drowsy on real-time.

Respiration Measurement System using Textile Capacitive Pressure Sensor (전기용량성 섬유 압력센서를 이용한 호흡측정 시스템)

  • Min, Se-Dong;Yun, Young-Hyun;Lee, Chung-Keun;Shin, Hang-Sik;Cho, Ha-Kyung;Hwang, Seon-Cheol;Lee, Myoung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.58-63
    • /
    • 2010
  • In this paper, we proposed a wearable respiration measurement system with textile capacitive pressure sensor. Belt typed textile capacitive pressure sensor approach of respiration measurement, from which respiration signatures and rates can be derived in real-time for long-term monitoring, are presented. Belt typed textile capacitive pressure sensor has been developed for this measurement system. the distance change of two plates by the pressure of motion has been used for the respiration measurement in chest area. Respiration rates measured with the textile capacitive pressure sensor was compared with standard techniques on 8 human subjects. Accurate measurement of respiration rate with developed sensor system is shown. The data from the method comparison study is used to confirm theoretical estimates of change in capacitance by the distance change. The current version of respiratory rate detection system using textile capacitive pressure sensor can successfully measure respiration rate. It showed upper limit agreement of $3.7997{\times}10^{-7}$ RPM, and lower limit of agreement of $-3.8428{\times}10^{-7}$ RPM in Bland-Altman plot. From all subject, high correlation were shown(p<0.0001). The proposed measurement method could be used to monitor unconscious persons, avoiding the need to apply electrodes to the directly skin or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range and quality of the rate-finding, broadening the potential application areas of this technology.

Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor (복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구)

  • Min, Se-Dong;Kim, Jin-Kwon;Shin, Hang-Sik;Yun, Young-Hyun;Lee, Chung-Keun;Lee, Jeong-Whan;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.