• Title/Summary/Keyword: Respiration

Search Result 2,058, Processing Time 0.027 seconds

Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor (복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구)

  • Min, Se-Dong;Kim, Jin-Kwon;Shin, Hang-Sik;Yun, Young-Hyun;Lee, Chung-Keun;Lee, Jeong-Whan;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.

Respiration Detection Method Using the PPG Signal Pattern (광용적맥파의 신호 패턴을 이용한 호흡 검출 기법)

  • Park, Moon Su;Kim, Jeong Goo
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.11
    • /
    • pp.1862-1870
    • /
    • 2016
  • A respiration is one of the most useful techniques for vital checking and an abnormal respiration is often the earliest sign of critical illness. Detection of respiration is based on the photo-plethysmography (PPG) with photodiode technique. Because PPG sensor using photodiode can be easily miniaturized, it is suitable for wearable devices. A system to measure respiration rate based on PPG signal is implemented and for a reliable measurement an improved algorithm in accuracy using PPG signal pattern is proposed in this paper. As results regarding to three types of respirations (regular interval, free interval, and weak respiration) the proposed algorithm showed error rate of 0.047, 0.067, and 0.122 respectively.

A Study on the Effects of Meditative Respiration Training on the Changes of Stress Hormones (명상호흡 수련이 스트레스성 호르몬에 미치는 영향에 관한 연구)

  • Park, Sang-Kyu
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.47-55
    • /
    • 2004
  • The purpose of this study were to investigate the effect of meditative respiration training for 6weeks on the changes of ACTH and Cortisol which are stress hormones in 10 male workers. The results of this study were as follows : 1. After meditative respiration training for 6weeks, the changes of heart rate, respiratory rate, SBP, DBP were slightly decreased. 2. After meditative respiration training for 6weeks, the changes of ACTH hormone were significantly decreased(p<.01). 3. After meditative respiration training for 6weeks, the changes of cortisol hormone were significantly decreased(p<.05). The above conclusions suggested that short-term meditative respiration training was an effective training method to changes mental emotional states and physiological stress hormone level affirmatively. Further, the future researches must analyze the physiological and psychological characteristics affecting mental health synthetically and develop meditative respiration program suitable to the various items and classes, especially EMT.

  • PDF

Real Time Driver's Respiration Monitoring (실시간 운전자 호흡 모니터링)

  • Park, Jaehee;Kim, Jaewoo;Lee, Jae-Cheon
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.142-147
    • /
    • 2014
  • Real time driver's respiration monitoring method for detecting driver's drowsiness is investigated. The sensor to obtain driver's respiration signal was a piezoelectric pressure sensor attached at the abdominal region of the seat belt. The resistance of the pressure sensor was changed according to the pressure applied to the seat belt due to the driver's respiration. Monitoring driver's respiration was carried out by driving on the virtual road in a driving simulator from Cheonan to Seoul and monitoring results were compared to the PELCLOS. Experiment results show that the driver's respiration signal can be used for detecting driver's drowsiness.

Compilation of Respiration Model Parameters for Designing Modified Atmosphere Package of Fresh Produce

  • An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • Enzyme kinetics-based respiration model can be effectively used for estimating respiration rate in $O_2$ consumption and $CO_2$ production of fresh produce as a function of $O_2$ and $CO_2$ concentrations. Arrhenius equation can be applied to describe the temperature dependence of the respiration rate. Parameters of enzyme kinetics-based respiration model and activation energy of Arrhenius equation were compiled from analysis of literature data and closed system experiment. They enable to estimate the respiration rate for any modified atmosphere conditions at temperature of interest and thus can be used for design of modified atmosphere packaging of fresh produce.

  • PDF

Soil Respiration in Pinus rigida and Larix leptolepis Plantations (리기다소나무와 낙엽송(落葉松) 인공조림지내(人工造林地內) 토양발생(土壤發生) 이산화탄소(二酸化炭素)에 관한 연구(硏究))

  • Son, Yowhan;Kim, Hyun-Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.3
    • /
    • pp.496-505
    • /
    • 1996
  • Soil respiration was measured every two weeks from May through November 1995 using the soda lime method in 40-Year-old Pinus rigida and Larix leptolepis plantations on a similar soil in Yangpyeong, Kyonggi Province. Treatments included control and no-roots(plots trenched and root regrowth into plots prevented). Root respiration was evaluated by comparing no-roots sub-plots to control plots. Mean soil respiration showed highly significant species effects(p<0.01) and was highest at the Pinus rigida control plot($0.38g/m^2/hr$) and lowest at the Larix leptolepis no-roots plot($0.31g/m^2/hr$). High soil respiration in Pinus rigida may be related to aboveground litter production. The annual $CO_2$ fluxes ranged from 23 to 27t/ha/yr. We found significant correlations between temperatures(air : $R^2$=0.53, soil : $R^2$=0.55) and soil respiration(p<0.01), but no significant correlations between soil moisture and soil respiration(p>0.1). Root respiration was 3% of total soil respiration. We might underestimate rapt respiration because of shallow trenches and $CO_2$measurements right after trenching. Factors controlling soil respiration including belowground litterfall(especially fine roots) inputs, litter quality should be well understood to predict soil carbon fluxes and relative contributions to total soil respiration in forest ecosystems.

  • PDF

The Study on the Change of EGG and HRV through Respiratory Control (호흡조절에 따른 위전도와 심박변이도 변화 연구)

  • Haa, Song-Yong;Park, Young-Bae;Yang, Dong-Hoon;Park, Young-Jae;Kim, Min-Yong
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.1
    • /
    • pp.157-166
    • /
    • 2007
  • Background: The change in the respiratory pattern has an influence on the change in the autonomic nervous system, which in turn has an influence on the EGG to measure a gastric activity. However, the study on the influence on the EGG parameters by respiratory control and on the correlation between the HRV and EGG through respiratory control has not been perform yet. Objective: It is to perform a series of experiments to find out how the EGG parameters are influenced by the controlled respiration and what correlation there may exist between the EGG and HRV to measure the change in the autonomic nervous system after controlled respiration. Methods: 1st Experiment: During a 15minutes' voluntary respiration, HRV was measured, and it was measured again during another 15 minutes' controlled respiration. 2nd Experiment: After an eight hours' fast, EGG was measured for a period of 30 minutes, and then after another 15 minutes' voluntary respiration, a test-meal was offered for 10 minutes and again EGG was measured. The next day, after an 8 hour's fast, EGG was measured for 30 minutes, and after a 15 minutes' controlled respiration and offered with a test-meal for 10 minutes and then EGG was measured again for 30 minutes. Results: 1. It was observed in all the channels that the power ratio increased more after controlled respiration than after voluntary respiration. No statistical significance, however, could be observed. 2. Through controlled respiration, the HF of HRV and the power ratio of EGG Channel 4 was negatively correlated, while the LF/HF of HRV and the power ratio of EGG channel 1 & 4 was positive correlated. Such correlations as mentioned above, however, could not be observed in HRV & EGG through voluntary respiration. Conclusions: 1. It was concluded that the increase in the power of gastric contractile after controlled respiration is bigger than the increase in the power of gastric contractile after voluntary respiration. 2. It was concluded that the gastric contractile power and sympathetic activity through controlled respiration was negatively correlated, while the gastric contractile power and parasympathetic activity through controlled respiration was positively correlated.

  • PDF

The Analysis on the Reliability of Measuring Pulse-Respiration Ratio (맥솔(脈率) 측정방법(測定方法)의 신뢰도(信賴度) 분석(分析))

  • Kim, Dong-Hoon;Yang, Dong-Hoon;Huh, Woong;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.123-144
    • /
    • 2005
  • Objectives: Pulse-Respiration Ratio has been used for estimating subject's Han-Yeol [寒熱] status since it mentioned in suwen [素問]. In practicing Pulse-Respiration Ratio over 5 means the status of Yeol [熱], Pulse-Respiration Ratio below 3 means the status of Han [寒]. We performed this study to examine the Optimum Standard for Measuring Pulse-Respiration Ratio on the Basis of Repeatability and Reproducibility. Methods: After subject's 5 minutes rest we measured subject's ECG, respiration pattern, EEG, EMG simultaneously. In this research examiner's number is two, subject's number is four, and the number of repeat is two. We calculated Pulse-Respiration Ratio through dividing Respiration cycle average by Pulse cycle average according to each standard including time section, $EEG(relative-{\alpha}$ density, $relative-{\beta}$ density, ${\alpha}/{\beta}$ and EMG. We analyzed these data through Gage R&R study using MINITAB 13.20 program and considered the results of below 30 %R&R and over 4 Number of Distinct Categories to have a significance. Results: 1. In the applying of time standard, Pulse-Respiration Ratio from section 3, 4, 6, 8 had a significant meaning in the aspect of Repeatability and Reproducibility. 2. In the applying of $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$, EMG(E I) standard, there was no significant results. 3. In the applying of time standard(section 5, 6, 7), $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$ and EMG(E I) standard simultaneously, Pulse-Respiration Ratio from ${\alpha}/{\beta}$ in section 6, ${\beta}$ I in section 8 had a significant meaning in the aspect of Repeatability and Reproducibility. Conclusions: We can suggest the Optimum Standard for Measuring Pulse-Respiration Ratio on the basis of Repeatability and Reproducibility as followings; 1. Pulse-Respiration Ratio Measuring time should be at least 15 minutes. 2. Applying of time(section 6, 8) and $EEG({\beta}$ I, ${\alpha}/{\beta})$ standard simultaneously is recommended considering reliability and validity but more study is needed. 3. EMG(E I) may be helpful to detect the segment of physical rest and exclude artifacts but more study is needed.

  • PDF

Effects of Hexavalent Chromium on Mitochondrial Respiration of Rat Kidney and Function of Low-Molecular-Weight, Chromium-Binding Substances ($Cr^{6+}$가 흰쥐 신장세포내 미토콘드리아의 호흡에 미치는 영향과 저분자 크롬결합물질의 작용)

  • Kang, Soo-Gil;Boo, Moon-Jong;Choe, Rim-Soon
    • Applied Microscopy
    • /
    • v.19 no.2
    • /
    • pp.43-58
    • /
    • 1989
  • To investigate the effects of hexavalent chromium on mitochondrial respiration of rat kidney, various hexavalent chromium concentrations were treated, then respiration and electron transfer enzyme activities were measured. Ultrastructural changes at state IV respiration of mitochondria were also observed. Then, to investigate protective role against hexavalent chromium in the body, low-molecular-weight, chromium-binding substances (LMCr) were purified from livers of rabbits 2hr after intravenously administrated with sodium dichromate at a dose of 74mg per kg body weight. And then, respiration rates of mitochondria treated with LMCr, hexavalent chromium containing 0.7mM chromium were measured. Hexavalent chromium decreased state IV respiration rates and electron transfer enzyme activities of mitochondria, and increased labile membrane and swelling. And partial inhibitions of condensed to orthodox conformational change were observed. Respiration rates of mitochondria treated with LMCr containing 0.7mM chromium did not differ from that of the non-treated mitochondria. But respiration rates of 0.7mM hexavalent chromium-treated mitochondria decreased by 42%, compared to non-treated mitochondria. These results suggest that LMCr may play an important role in detoxification of toxic hexavalent chromium.

  • PDF

A Cross-age Study on Elementary Students이 Understanding of the Concept of Respiration (초등학생의 호흡 개념 이해에 대한 연구)

  • 성정희;김영수
    • Journal of Korean Elementary Science Education
    • /
    • v.19 no.2
    • /
    • pp.57-74
    • /
    • 2000
  • Students' concepts of scientific phenomena have become a point of focus in science education research. This study investigated into developmental process and mechanism of the students' respiration concept through a cross-age study. This study utilized the 1st, 3rd, 6th grade elementary students to find out changes in student's understanding of the concept of respiration. The 1st and 3rd grade level students were interviewed what the respiration mean and whether each of living things respires, etc. The 6th grade students were interviewed and tested. Respiration is a word that students come across often in everyday life. It was found that they were more likely to associate respiration with its more common concept of breathing or gas exchange as opposed to its more scientific definition as the process in which nutrients are oxidized to provide energy. This trend didn't improve as they advanced grade. This is an indication that the knowledge system of student is split into a generic knowledge system and scientific knowledge system. Understanding of concept increased and differentiated across grade levels but that understanding was limited. They overcome their tendency to base their understanding of respiration on their understanding of human phenomena and learn to integrate their understanding of biological phenomena through a one organ - one role type of logic. They also intuitively explain everything based on their own experience.

  • PDF