• 제목/요약/키워드: Respirable particulate mass(RPM)

검색결과 5건 처리시간 0.018초

태백지역 석탄광업 굴진부서의 부유분진 농도 (Suspended Particulate Concentration at the Drilling Site of Underground Coal Mines in Taebaek Area)

  • 윤영노;김영식;이영신
    • 한국환경보건학회지
    • /
    • 제17권1호
    • /
    • pp.32-38
    • /
    • 1991
  • Airborne suspended particulate concentration in drilling sites of underground coal mines in Taebaek area was evaluated. And respirable coal dust exposure level was evaluated. Airborne suspended particulate mass include total suspended particle(TSP) and thoracic particle(TPM). TSP (by open-face filter holder) and TPM(by elutriator) concentration were determined by low volume air samplers. Personal air samplers were attached to the coal workers including drillers, coal cutters, and their assistants. Normality and log-normality of TSP, TPM, and respirable dust(RPM) concentration were tested by Kolmogorov-Smirnov one-sample test. Differences of means of TSP, TPM, and RPM concentration were tested by paired t-test. Relation between TSP, TPM, and RPM with pairs were tested by regression test and Pearson's correlation.

  • PDF

서울 지하철 내 공기 중 먼지의 특성에 관한 연구 (A study on Characteristics of Airborne Dusts in Seoul Subway Stations)

  • 김진경;백남원
    • 한국환경보건학회지
    • /
    • 제30권2호
    • /
    • pp.154-160
    • /
    • 2004
  • The purpose of this study was to evaluate airborne concentrations and characteristics of TSP, IPM, TPM and RPM in Seoul subway stations. Sampling was performed at 14 stations from April 11 to 29, 2002. Size-selective dust concentrations and metal concentrations were measured by gravimetric method and ICP-AES, respectively. The geometric mean of TSP, IPM, TPM and RPM concentrations in Seoul subway stations were 176$\mu\textrm{g}$/㎥, 348$\mu\textrm{g}$/㎥, 158$\mu\textrm{g}$/㎥ and 104$\mu\textrm{g}$/㎥, respectively. Dust concentrations in pathway were the highest and those in lobby were the lowest. The size distribution of dusts was significantly different by location of collection. When the deposition rate into pulmonary gas exchange region was estimated by size distribution, the deposition rate of dust collected from platform was higher than those of dust collected from lobby and pathway. The lower the basement levels were, the higher the deposition rates of dusts into tracheobronchial region and gas exchange region were. Copper and iron concentrations measured in platform higher were than those in other areas.

황사기간도안 제주, 고산지역에서 호흡성 분진의 입자 분포 특성 (Characteristics According to the Size Distributions of Respirable Particulate During Yellow Sand Episode in Kosan, Jeju Island)

  • Kim, Jeong-Ho;Ahn, Jun-Young;Han, Jin-Seok;Lee, Jeong-Joo
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.91-96
    • /
    • 2003
  • This study was intended as an investigation of characteristics of background site atmospheric respirable particulate matters(RPM), and fine particles(<2.5 ${\mu}{\textrm}{m}$). The particle size distributions during the phenomenon of Yellow Sand(YS) occurs from April, 2001. Atmospheric aerosol particulate matter was directly collected on the Jeju island between 1 to 30, April, 2001 using an eight-stage cascade impacter(particle size range: 0.43-11 ${\mu}{\textrm}{m}$), and cyclone separator(cut size: 2.5, 10 ${\mu}{\textrm}{m}$). The episode of YS observed in background monitoring site, Kosan and appeared 2 times at sampling period. The mass concentrations of fine and coarse particles for YS episode were 34.2 and 59.6 $\mu\textrm{g}$/㎥, respectively, which were significantly increased amounts compared to 13.3 and 13.0 $\mu\textrm{g}$/㎥ for NonYS(NYS). Most size distributions had two peaks, one at 0.43∼.65 ${\mu}{\textrm}{m}$ and the other at 3.3${\mu}{\textrm}{m}$4.7 ${\mu}{\textrm}{m}$. The result of analysis of water-soluble ion component indicated that sulfate was mainly ion component, but nitrate and calcium ion was significantly increased at the YS episode.

타코나이트 광산 공정에서의 실시간 질량측정기기와 실시간 수농도의 환산에 의한 질량농도와의 연관성 (Relationships between a Calculated Mass Concentration and a Measured Concentration of PM2.5 and Respirable Particle Matter Sampling Direct-Reading Instruments in Taconite Mines)

  • 정은교;장재길;송세욱;김정호
    • 한국산업보건학회지
    • /
    • 제24권1호
    • /
    • pp.65-73
    • /
    • 2014
  • Objectives: The purposes of this study are to investigate workers' exposures to respirable particles generated in taconite mines and to compare two metric methods for mass concentrations using direct-reading instruments. Methods: Air monitorings were conducted at six mines where subjects have been exposed primarily to particulate matters in crushing, concentrating, and pelletizing processes. Air samples were collected during 4 hours of the entire work shift for similarly exposure groups(SEGs) of nine jobs(N=37). Following instruments were employed to evaluate the workplace: a nanoparticle aerosol monitor(particle size range; 10-1000 nm, unit: ${\mu}m^2/cc$, Model 9000, TSI Inc.); DustTrak air monitors($PM_{10}$, $PM_{2.5}$, unit: $mg/m^3$, Model 8520, TSI Inc.); a condensation particle counter(size range; 20-1000 nm, unit: #/cc, P-Trak 8525, TSI Inc.); and an optical particle counter(particle number by size range $0.3-25{\mu}m$, unit: #/cc, Aerotrak 9306, TSI Inc.). Results: The highest airborne concentration among SEGs was for furnace operator followed by pelletizing maintenance workers in number of particle and surface area, but not in mass concentrations. The geometric means of $PM_{2.5}$ by the DustTrak and the Ptrak/Aerotrak were $0.04{\mu}m$(GSD 2.52) and $0.07{\mu}m$(GSD 2.60), respectively. Also, the geometric means of RPM by the DustTrak and the Ptrak/Aerotrak were $0.16{\mu}m$(GSD 2.24) and $0.32{\mu}m$(GSD 3.24), respectively. The Pearson correlation coefficient for DustTrak $PM_{2.5}$ and Ptrak/Aerotrak $PM_{2.5}$ was 0.56, and that of DustTrak RPM and Ptrak/Aerotrak RPM was 0.65, indicating a moderate positive association between the two sampling methods. Surface area and number concentration were highly correlated($R^2$ = 0.80), while $PM_{2.5}$ and RPM were also statistically correlated each other($R^2$ = 0.79). Conclusions: The results suggest that it is possible to measure airborne particulates by mass concentrations or particle number concentrations using real-time instruments instead of using the DustTrak Aerosol monitor that monitor mass concentrations only.

업종별 공기중 납입자의 입경별 분포특성에 관한 조사 연구 (A Study on the Characteristic of Airborne Lead Particle Size by Industry)

  • 박동욱;백남원
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.160-171
    • /
    • 1995
  • The size characteristics of lead particle which is one of the important factors associated with absorption of lead were ignored in establishing lead standard. This study was conducted to investigate distribution of lead particles by operation of industry. Aerodynamic Mass Median Diameters (MMD) of airborne lead particles in the battery and litharge manufacturing industry were $14.1{\mu}m$ and $15.1{\mu}m$, respectively. There was no significant difference between those two values(p>0.05). However, the diameters in radiator manufacturing and secondary smelting industry were $1.3{\mu}m$, $4.9{\mu}m$, respectively. Those were significantly smaller than the particle sizes in other industries(p<0.05). Total lead concentrations in the secondary smelting industry were higher than those in the battery and litharge manufacturing industry. Total lead concentrations in other industries except radiator manufacturing industry exceeded the standard of $50{\mu}g/m^3$. Only radiator manufacturing industry indicated lead concentrations significantly lower than those in other industries(p<0.05). Concentrations of lead particles smaller than $1{\mu}m$ defined as respirable fraction by OSHA's CPA model assumption were $72.4{\mu}g/m^3$ in the secondary smelting industry, exceeding $50{\mu}g/m^3$. The relationship of concentrations between total lead and lead of particles smaller than $1{\mu}m$ was log Y = 0.46 logX + 0.06(n=119, $r^2=0.44$, p=0.0001). Relationship of respirable lead concentrations between OSHA and ACGIH was significantly detected in the litharge and battery manufacturing industry(p=0.0001), but was not significant in the radiator(p=0.2720) and secondary smelting manufacturing industry(p=0.2394). As MMDs of lead particles generated in industry were small, difference of respirable lead concentration between OSHA and ACGIH became smaller. There was a significant difference between concentrations respirable lead defined by two organizations such as OSHA and ACGIH in the battery and litharge manufacturing industry. Average concentration of respirable lead by ACGIH definition was 43.3 % of total lead in secondary smelting and 48.9 % in radiator manufacturing industry, and lower fractions were indicated in battery and litharge manufacturing industry. Relationships of total lead with IPM, TPM, and RPM were significant respectively(p=0.0001) and lead concentrations by particle size could be estimated using this relationship. Linear regression equation between total lead concentration(X) and ACGIH-RPM concentration(Y) was log Y = 0.76 log X - 0.40($r^2=0.89$, p=0.0001).

  • PDF