• Title/Summary/Keyword: Resonant method

Search Result 1,123, Processing Time 0.027 seconds

Estimation of Shear Moduli Degradation Characteristics from Pressuremeter Tests (프레셔미터 시험을 이용한 전단탄성계수 감쇠 특성 평가)

  • Kwon, Hyung Min;Chung, Choong Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3C
    • /
    • pp.105-113
    • /
    • 2009
  • Pressuremeter test estimates deformational properties of soil from the relationship between applied pressure and the displacement of cavity wall, and the results reflect the in-situ stress condition and the structure of soil particles. This study suggests the overall process of test and analysis for the evaluation of nonlinear degradation characteristics of shear moduli, based on the reloading curve of pressuremeter test. The method estimates the maximum shear modulus, taking into account the difference between the stress states around the probe in reloading and that of the in-situ state, and then combines the degradation characteristics of shear moduli taken from reloading curve. This procedure derives the shear moduli in overall strain range. Pressuremeter tests were carried out in various ground conditions using large calibration chamber, together with various reference tests. Shear moduli taken from pressuremeter tests were compared with bender element test and resonant column test results.

Nonlinear vibration analysis of fluid-conveying cantilever graphene platelet reinforced pipe

  • Bashar Mahmood Ali;Mehmet AKKAS;Aybaba HANCERLIOGULLARI;Nasrin Bohlooli
    • Steel and Composite Structures
    • /
    • v.50 no.2
    • /
    • pp.201-216
    • /
    • 2024
  • This paper is motivated by the lack of studies relating to vibration and nonlinear resonance of fluid-conveying cantilever porous GPLR pipes with fractional viscoelastic model resting on nonlinear foundations. A dynamical model of cantilever porous Graphene Platelet Reinforced (GPLR) pipes conveying fluid and resting on nonlinear foundation is proposed, and the vibration, natural frequencies and primary resonant of such system are explored. The pipe body is considered to be composed of GPLR viscoelastic polymeric pipe with porosity in which Halpin-Tsai scheme in conjunction with fractional viscoelastic model is used to govern the construction relation of the nanocomposite pipe. Three different porosity distributions through the pipe thickness are introduced. The harmonic concentrated force is also applied on pipe and excitation frequency is close to the first natural frequency. The governing equation for transverse motion of the pipe is derived by the Hamilton principle and then discretized by the Galerkin procedure. In order to obtain the frequency-response equation, the differential equation is solved with the assumption of small displacement, damping coefficient, and excitation amplitude by the multiple scale method. A parametric sensitivity analysis is carried out to reveal the influence of different parameters, such as nanocomposite pipe properties, fluid velocity and nonlinear viscoelastic foundation coefficients, on the primary resonance and linear natural frequency. Results indicate that the GPLs weight fraction porosity coefficient, fractional derivative order and the retardation time have substantial influences on the dynamic response of the system.

Real-time 14N NQR-based sodium nitrite analysis in a noisy field

  • Mohammad Saleh Sharifi;Ho Seung Song;Hossein Afarideh;Mitra Ghergherehchi;Mehdi Simiari
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4570-4575
    • /
    • 2023
  • Noise and Radio-frequency interference or RFI causes a significant restriction on the Free induction Decay or FID signal detection of the Nuclear Quadrupole Resonance procedure. Therefore, using this method in non-isolated environments such as industry and ports requires extraordinary measures. For this purpose, noise reduction algorithms and increasing signal-to-noise-and-interference ratio or SNIR have been used. In this research, sodium nitrite has been used as a sample and algorithms have been tested in a non-isolated environment. The resonant frequencies for the 150 g of test sample were measured at 303 K at about 1 MHz and 3.4 MHz. The main novelty in this study was, (1) using two types of antennas in the receiver to improve adaptive noise and interference cancellation, (2) using a separate helical antenna in the transmitter to eliminate the duplexer, (3) estimating the noise before sending the pulse to calculate the weighting factors and reduce the noise by adaptive noise cancellation, (3) reject the interference by blanking algorithm, (4) pulse integration in the frequency domain to increase the SNR, and (5) increasing the detection speed by new pulse integration technique. By interference rejection and noise cancellation, the SNIR is improved to 9.24 dB at 1 MHz and to 7.28 dB at 3.4 MHz, and by pulse integration 44.8 dB FID signal amplification is achieved, and the FID signals are detected at 1.057 MHz and 3.402 MHz at room temperature.

A study on the preparation of $(Ba_{1-X}Sr_X)ZrO_3$ using oxalate method and its dielectric properties (수산염법에 의한 $(Ba_{1-X}Sr_X)ZrO_3$의 합성 및 그의 유전특성에 관한 연구)

  • Oh Seong Kweon;Nam Seok Baik;Byung Ha Lee
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.3
    • /
    • pp.252-261
    • /
    • 1994
  • The $(Ba_{1-X}Sr_X)ZrO_3$ powder showing chemically pure and fine particle size was attempted to be synthesized by the oxalate method. The objective of this study is to determine the optimum synthesis condition of stable $(Ba_{1-X}Sr_X)ZrO_3$ powder in terms of the temperatures coefficient of resonant frequency ${\tau}_f$ by examining the microstructure and dielectric properties of the synthesized powder. The six compounds (x=0, 0.2, 0.4, 0.6, 0.8, 1) of $(Ba_{1-X}Sr_X)ZrO_3$ were prepared by the oxalate method, and then calcined at $1000^{\circ}C$ to obtain the crystalline $(Ba_{1-X}Sr_X)ZrO_3$ powder. The synthesized powder showed the globular-shape and average particle size of less than $0.2 \mu\textrm{m}$. The composition of x=0.5, i.e., half of Ba was replaced by Sr, is experted to show the zero value of temperatures coefficient of capacitance ${\tau}_c$.

  • PDF

Study on the Medical Review on Yukjagyeol and Younggamudo Its Clinical Application (육자결(六字訣)과 영가무도(詠歌舞蹈)의 한의학적 고찰 및 임상적용에 대한 연구)

  • Lee, Dong-Wook;Han, Chang-Hyun;Park, Soo-Jin;Kwon, Young-Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.516-527
    • /
    • 2008
  • Sounds and music have been used in various ways in the East and the West, as it is well known that they influence the human mind and health a lot. Recently, there have been many studies regarding the remedy through sounds and music in the West and they have made good effects in the actual therapy. In the East, people knew that sounds and music would make great effects on human mind long time ago and they placed importance on sounds and music. Although there is a Sound Therapy in Oriental Medicine, it is not studied sufficiently in modern Oriental Medicine. It does not have clear standards for the clinical application and has not been frequently used. Accordingly, Yukjagyeol which has long been used in Korean Medicine and Younggamudo which was made by Kim Il-bu in late Chosun were compared from the perspective of acoustics and demonstrative treatment theory of Korean Medicine. Younggamudo by Kim il-bu allot the five sounds such as 'Eum, Ah, Eo, Ih and Uh' to 'spleen, lung, liver, heart and kidney' respectively. As the five sounds are all vowels and vibrate the vocal band as much as possible, they vibrate and resonant the respective organs to help them to function and promote circulation. In oriental medicine, there is 'Singing and Dancing Treatment'. They say songs and dances nurtures personality, supplement blood stream and comfort the mind. As the five sounds of Younggamudo take the melody while vibrating the vocal band sufficiently, when it passes from Youngto Ga(Songs) we may dance moving our bodies according to the rhythm. Therefore Gongbeop of Younggamudo helps the functionality of human organs and promotes blood circulation. As Yukjagyeol is Sabeop(discharging method), it should be used for those who have surplus Sagi and should not use for Heojeung. As Younggamudo is Bobeop(supplementing method), it is not for Shiljeung but for Heojeung which lacks of Jeonggi. It is considered that healthy people without specific disease can use it as a preventive method of 'Chimijeong' to maintain their physical and mental health. It is considered that we can have useful effects if we apply Yukjagyeol and Younggamudo dialectically with the concept of Bosa. It is considered that concrete application to Sound Gigong can be possible by searching for the methodology for empirical further study and clinical experiments and clinical application in the future.

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

An Analysis in Optimum Coupling Method of Cylindrical Dielectric Resonator Filter Designed by Non-decaying Mode Analysis (Non-decaying 모드 해석을 이용해서 설계한 원통형 유전체 공진기 여파기의 최적 결합 방법에 대한 분석)

  • Lee, Won-Hui;Park, Chang-Won;Kim, Tai-Shin;Hur, Jung;Lee, Sang-Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.7
    • /
    • pp.14-21
    • /
    • 2001
  • In this paper, we designed and fabricated C-band bandpass filter using dielectric resonators. From waveguide cutoff frequency which applied the region between adjacent dielectric resonators, the height of cavity is determined. The cavity's diameter is determined to the twice of dielectric resonator? diameter considering the conductor loss. The resonant frequency of the DR cavity is calculated with non decaying mode analysis. Conventionally, cylindrical dielectric resonator is analysed by Cohn's model which use the decaying mode in the region between dielectric resonator wall and circular cavity wall, which is an approximated method. The external quality factor, $Q_{ex}$ has found with simulation result using Ansoft's Maxwell simulation tool. The designed filter using dielectric resonators with dielectric constant of 45 has the passband center at 5.065GHz. The bandpass filter using dielectric resonators has about 1dB insertion loss, 20MHz bandwidth and more than 30dB attenuation at $f_0+15MHz$.

  • PDF

Effect of Temperature and Aging on the Relationship Between Dynamic and Static Elastic Modulus of Concrete (온도와 재령이 콘크리트의 동탄성계수와 정 탄성계수의 상관관계에 미치는 영향)

  • 한상훈;김진근;박우선;김동현
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.610-618
    • /
    • 2001
  • This paper investigates the relationships between dynamic elastic modulus and static elastic modulus or compressive strength according to curing temperature, aging, and cement type. Based on this investigation, the new model of the relationships we proposed. Impact echo method estimates the resonant frequency of specimens and uniaxial compression test measures the static elastic modulus and compressive strength. Type I and V cement concretes, which have the water-cement ratios of 0.40 and 0.50, are cured under the isothermal curing temperatures of 10, 23, and 50$\^{C}$ Cement type and aging have no large influence on the relationship between dynamic and static elastic modulus, but the ratio of dynamic and static elastic modulus comes close to 1 as temperature increases. Initial chord elastic modulus which is calculated at lower strain level of stress-strain curve, has the similar value to dynamic elastic modulus. The relationship between dynamic elastic modulus and compressive strength has the same tendency as the relationship between dynamic and static elastic modulus according to cement type, temperature and aging. The proposcd relationship equations between dynamic elastic modulus and static elastic modulus or compressive strength properly estimates the variation of relationships according to cement type md temperature.

Transient Torsional Vibration Response due to Ice Impact Torque Excitation on Marine Diesel Engine Propulsion Shafting (선박용 디젤엔진 추진축에서 빙 충격 토크 기진에 의한 과도 비틀림 진동 응답)

  • Barro, Ronald D.;Eom, Ki Tak;Lee, Don Chool
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.5
    • /
    • pp.321-328
    • /
    • 2015
  • In recent years, there has been an increasing demand to apply the new IACS(International Association of Classification Societies) standards for ice and polar-classed ships. For ice-class vessel propulsion system, the ice impact torque design criterion is defined as a periodic harmonic function in relation to the number of the propeller blades. However, irregular or transient ice impact torque is assumed to occur likely in actual circumstances rather than these periodic loadings. In this paper, the reliability and torsional vibration characteristics of a comparatively large six-cylinder marine diesel engine for propulsion shafting system was examined and reviewed in accordance with current regulations. In this particular, the transient ice impact torque and excessive vibratory torque originating from diesel engine were interpreted and the resonant points identified through theoretical analysis. Several floating ice impacts were carried out to evaluate torque responses using the calculation method of classification rule requirement. The Newmark method was used for the transient response analysis of the whole system.

Fabrication of Piezoresistive Silicon Acceleration Sensor Using Selectively Porous Silicon Etching Method (선택적인 다공질 실리콘 에칭법을 이용한 압저항형 실리콘 가속도센서의 제조)

  • Sim, Jun-Hwan;Kim, Dong-Ki;Cho, Chan-Seob;Tae, Heung-Sik;Hahm, Sung-Ho;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.21-29
    • /
    • 1996
  • A piezoresistive silicon acceleration sensor with 8 beams, utilized by an unique silicon micromachining technique using porous silicon etching method which was fabricated on the selectively diffused (111)-oriented $n/n^{+}/n$ silicon subtrates. The width, length, and thickness of the beam was $100\;{\mu}m$, $500\;{\mu}m$, and $7\;{\mu}m$, respectively, and the diameter of the mass paddle (the region suspended by the eight beams) was 1.4 mm. The seismic mass on the mass paddle was formed about 2 mg so as to measure accelerations of the range of 50g for automotive applications. For the formation of the mass, the solder mass was loaded on the mass paddle by dispensing Pb/Sn/Ag solder paste. After the solder paste is deposited, Heat treatment was carried out on the 3-zone reflow equipment. The decay time of the output signal to impulse excitation of the fabricated sensor was observed for approximately 30 ms. The sensitivity measured through summing circuit was 2.9 mV/g and the nonlinearity of the sensor was less than 2% of the full scale output. The output deviation of each bridge was ${\pm}4%$. The cross-axis sensitivity was within 4% and the resonant frequency was found to be 2.15 KHz from the FEM simulation results.

  • PDF