• Title/Summary/Keyword: Resonant current

Search Result 960, Processing Time 0.028 seconds

A novel resonant pulse control in resonant DC link inverter (공진형 직류 링크 인버터의 공진 펄스 제어기)

  • 유동욱;원충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.152-158
    • /
    • 1996
  • A novel resonant pulse control technique which generates high-quality sinusoidal output voltage from a resonant dc link inverter is presented for UPS applicatons. The proposed control technique limits resonant voltae overshoot without any passive or active clamp circuit, resulting in resonant pulses iwth uniform amplitude and high efficiency. The output voltage is controlled by the third order contorller iwth an inner loop of th efilter inductor current and the feedforward controller. Analysis and design of the proposed control technique are illustrated and verified on a 5kVA experimental unit.

  • PDF

Current Control Method of Distribution Static Compensator Considering Non-Linear Loads (비선형 부하를 고려한 배전용 정지형 보상기의 전류제어 기법)

  • Kim, Dong-Geun;Choi, Jong-Woo;Kim, Heung-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1342-1348
    • /
    • 2009
  • DSTATCOM(distribution static compensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Researches about DSTATCOM are mainly divided two parts, one is the calculation of compensated current and the other part is the current control. This paper proposes a proportional-resonant-repetitive current controller. Improved performance of instantaneous power compensation has been shown by simulations and experiments.

Analysis and Implementation of LC Series Resonant Converter with Secondary Side Clamp Diodes under DCM Operation for High Step-Up Applications

  • Jia, Pengyu;Yuan, Yiqin
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.363-379
    • /
    • 2019
  • Resonant converters have attracted a lot of attention because of their high efficiency due to the soft-switching performance. An isolated high step-up converter with secondary-side resonant loops is proposed and analyzed in this paper. By placing the resonant loops on the secondary side, the current stress for the resonant capacitors is greatly reduced. The power loss caused by the equivalent series resistance of the resonant capacitor is also decreased. Clamp diodes in parallel with the resonant capacitors ensure a unique discontinuous current mode in the converter. Under this mode, the active switches can realize soft-switching during both turn-on and turn-off transitions. Meanwhile, the reverse-recovery problems of diodes are also alleviated by the leakage inductor. The converter is essentially a step-up converter. Therefore, it is helpful for decreasing the transformer turn-ratio when it is applied as a high step-up converter. The steady-state operation principle is analyzed in detail and design considerations are presented in this paper. Theoretical conclusions are verified by experimental results obtained from a 500W prototype with a 35V-42V input and a 400V output.

Development of Medical Ruby Laser Power Supply using LLC Resonant Converter (LLC 공진형 컨버터를 적용한 의료용 루비 레이저 전원장치 개발)

  • Kim, Dong-Hyun;Jung, Jae-Hun;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.924-928
    • /
    • 2014
  • LLC resonant converter is used to control laser power density in ruby laser power supply. Zero voltage switching(ZVS) is implemented to minimize the switching loss by the LLC resonant converter. Laser output power is investigated and experimented by changing the output current. That current is controled by the charging voltage of capacitor. From those results, we obtained the maximum laser output of 1.94J at the discharge current of 860A and the pulse repetition rate of 1Hz.

An influence on Characteristics of double resonant type high frequency inverter according to the variable capatance of the DC voltage source separated capacitor (직류 전원 분할용 커패시터의 용량변화가 복공진형 고주파 인버터의 특성에 미치는 영향)

  • 박홍일
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.360-363
    • /
    • 2000
  • A half bridge type double resonant high frequency resonant inverter using PFM is described. This proposed inverter can reduce distribution of the switching current because of using the current of the serial resonant circuit to the input current of the parallel one. In the case of variable capacitance of the DC voltage source separated capacitor the analysis of inverter circuit has generally described by using normalized parameter and operating characteristics has been evaluated in terms of switching frequency and parameters. Based on the characteristics value a method of the circuit design is proposed. The theoretical results are in good agreement with the experimental ones. In the future this proposed circuit is considerated to be useful for induction heating and discharge lamp.

  • PDF

PARALLEL-RESONANT CONVERTER WITH ZVS-PWM CONTROL

  • Ninomiya, Tamotsu;Hashimoto, Takayoshi;Tanaka, Hidekazu;Syoyama, Masahito;Tymerski, Richard-P.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.85-90
    • /
    • 1998
  • A parallel-resonant converter with zero-voltage-switching, pulse-width-modulation(ZVS-PWM) control is proposed. Similar to the previously proposed series-resonant counterpart, it has a simple structure and can be controlled at a constant switching frequency using an active-clamp technique. The nearly constant current output characteristic of the parallel-resonant converter lends itself beneficially to precisely controlled constant current power supply applications. An experimental breadboard featured an accuracy of $\pm$1% for an output current of 2A, with an efficiency of 75%.

  • PDF

Single-Stage High-Power-Factor Electronic Ballast with a Symmetrical Class-DE Resonant Rectifier

  • Ekkaravarodome, Chainarin;Jirasereeamornkul, Kamon
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.429-438
    • /
    • 2012
  • This paper presents the use of a novel, single-stage high-power-factor electronic ballast with a symmetrical class-DE low-$d{\upsilon}$/$dt$ resonant rectifier as a power-factor corrector for fluorescent lamps. The power-factor correction is achieved by using a bridge rectifier to utilize the function of a symmetrical class-DE resonant rectifier. By employing this topology, the peak and ripple values of the input current are reduced, allowing for a reduced filter inductor volume of the EMI filter. Since the conduction angle of the bridge rectifier diode current was increased, a low-line current harmonic and a power factor near unity can be obtained. A prototype ballast, operating at an 84-kHz fixed frequency and a 220-$V_{rms}$, 50-Hz line input voltage, was utilized to drive a T8-36W fluorescent lamp. Experimental results are presented which verify the theoretical analysis.

Zero-voltage-switching three level auxiliary resonant commutated pole inverter (영전압 스위칭 3-레벨 보조 공진 폴 인버터)

  • 유동욱;원충연;조정구;백주원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.535-542
    • /
    • 1996
  • A zero voltage switching (ZVS) three level auxiliary resonant commutated pole inverter (ARCPI) is presented for high power GTO inverters. The concept of ARCP for two level inverter is extended to the three inverter. The proposed auxiliary commutation circuit consists of one resonant inductor and two bi-directional switches, which provides ZVS condition to the main devices without increasing device voltage or current stresses. The auxiliary device operates with zero current switching (ZCS) which enables use of the low cost thyristors. The proposed ARCPI can handle higher voltage and higher power (1-10MVA) comparing to the two level one. Operation and analysis of the ARCPI are illustrated and the features are compared o those of the snubber circuit incorporated three level inverter. Experimental results with 10kW, 4kHz prototype are presented to verify the principle of operation. (author). refs., figs., tab.

  • PDF

Transient Current Control of Two-Stage Electronics Ballast for HID Lamps (HID 램프용 Two-Stage 전자식 안정기의 과도 전류 제어)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • The conventional Three-Stage electronic ballast is stable, but Two-Stage electronic ballast has been researching because of efficiency. Three-Stage electronic ballast is consisted of PFC circuit, buck converter, and inverter circuit, but Two-stage is consisted of PFC circuit, Buck-Inverter full bridge circuit. The Buck-Inverter full bridge inverter consists of two half bridge inverters for low frequency switching, and high frequency switching. In the case of street lamp it is far from a lamp to a ballast, the conventional pulsed high voltage ignitor can not turn on the HID lamps because of reduction of ignition voltage. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps. Therefore, in the Two-Stage electronic ballast which has the resonant tank for ignition, the transient resonant current because of low frequency changing is analyzed, the novel algorithm is proposed to resuce the transient current.

Resonant Analysis of Load Commutated Current Source Inverter System (부하(負荷) 전류식(轉流式) 전류형(電流形) 인버터 시스템의 공진(共振) 해석(解析))

  • Sim, Cheon-Bo;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.156-159
    • /
    • 1991
  • At LCCSI system, output capacitor of inverter and inductor of load motor raise mutuality operation. This parallel resonant increase equivalent impedance of inverter load and give wrong effect at LCCSI system. This paper carried out resonant analysis of LCCSI system. The result of analysis, particular resonant point of two was discovered that a resonant of S=0 vicinity and $\beta$ resonant of S=1 vicinity. In addition to, the case of harmonics resonant not come from $\alpha$ resonant but come from $\beta$ resonant. A moment of working of LCCSI system, resonant line must not suddenly variation. Accordingly, resonant line is a necessity for doing $f{\alpha}$ vicinity by properly capacitor value selection.

  • PDF