• Title/Summary/Keyword: Resonance Type

Search Result 1,096, Processing Time 0.035 seconds

A COMPARATIVE STUDY ONMAGNETIC RESONANCE IMAGE AND SECTOGRAPH OF HUMAN TNJ (악관절의 자기공명영상과 시상단층 방사선촬영상에 관한 비교연구)

  • Lee, Sung-Bok;Choi, Dae-Gyun;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.249-270
    • /
    • 1993
  • For understanding of anatomy, physiology, and diseases of human TMJ, it is required to evaluate quantitatively the movement of the disc and condyle head of mandible. The histologic section of cadaver TMJ were examined, and the magnification of the MR image and its details of anatomy were evaluated. And then a quantitative analytic method, by comparing the Sectograph and the MR image of vital human TMJ, was proposed. For this study, 15 subjects(Male, 24~35years) were selected from a prosthodontic examination randomly, and each subject’s five interocclusal rubber registration records were made on the ICP, and 5, 10, 15, and 20mmjaw opening positions. All subjects were radiographed with a Denar Quint Sectograph Image System(Denar Corp., USA), and imaged with a MRP-20EX MR Image System(0.2T, Permanent Magnet Type, Hitachi Medical Corp., Japan) using an 100mm diameter bilateral type surface coil. These images were traced on the acetate tracing paper, and analyzed In this study, the findings led to the following conclusions. 1. In comparison of the histologic section of autopsy specimen with the MR image at the same section, the size(dimension) of MR image was 70% of the real one. It was possible to recognize the shape of articular disc, anterior and posterior attachments, and adjacent soft tissues, because of the excellent reproducibility of anatomical structure. 2. When we compared the amount of joint space on MR image with that of joint space on sectograph, the amount of joint space on sectograph was significantly greater than that of joint space on MR image, except at the top of condylar head. 3. The position of minimum joint space on sectograph at intercuspal position didn't coincide with the middle position of articular disc on MR image, and was approximately in the anterior third of posterior band of articular disc. 4. The amount of condylar movement on MR image at opening movement was greater than that of articular disc movement. From Intercuspal position to 5mm jaw-opening movement, the condylar movement showed hinge one, and over the range 5mm jaw-opening it suggested hinge & translatory one. 5. In terms of area variation of articular disc measured on MR image in sagittal plane, the area of posterior band increased with increasing the amount of Jaw opening, but the area of anterior band decreased conversely.

  • PDF

Development of Birdcage RF coil for 3T Animal MR Imaging

  • 추명자;최보영;강세권;최치봉;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2002
  • We authors developed a new small-size birdcage RF coil for animal MR images. And we compared signal-to-noise ratio (SNR) of the new small coil with a conventional knee coil. The dimension of the low-pass type birdcage coil with 12 elements at 37 MRI system are 13 cm outer diameter, 12 cm inner diameter and 20 cm length. For each element, the width of copper tape is 0.05 mm, thickness is 8 mm and length is 20 cm. The small birdcage coil with 12 elements exhibited 7 resonance modes. The isolation of the quadrature channel could be achieved more than 20 ㏈. The coil quality factor (Q value) was 98.6. The SNR of the animal coil was 243.2 on the average and was about twice as high as the conventional knee coil. The present study successfully demonstrated that the small birdcage coil could provide high quality animal MR images with the improved SNR. Therefore, it is expected that the small birdcage coil could be used in the clinical diagnosis and research studies for veterinary medicine in the near future.

  • PDF

The Dispersibility and Adsorption Behaviour of Cement Paste with Molecular Structures of Polycarboxylates (폴리카복실레이트 분자 구조에 따른 시멘트페이스트의 분산 및 흡착 특성 연구)

  • Shin, Jin-Yong;Hong, Ji-Sook;Suh, Jeong-Kwon;Lee, Young-Seok;Hwang, Eui-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.489-496
    • /
    • 2006
  • Graft copolymerized polycarboxylate(PC)-type superplasticizers which have carboxylic acid with $\pi$ bond among the molecular structure and polyethyleneglycol methyl ether methacrylate(PMEM) were synthesized by free radical reaction. To investigate their chemical structures and molecular weights, PCs were analyzed by FT-IR(fourier transform spectrometer), C-NMR(nuclear magnetic resonance spectrometer) and GPC(gel permeation chromatograpy). When types of carboxylic acids(methacrylic acid, acrylic acid, maleic anhydride, and itaconic acid) and molar ratios of carboxylic acid/PMEM) were varied, adsorptive and fluid characteristics in cement paste were discussed. As the molar ratio of carboxylic acid/PMEM) was higher, amount adsorbed on the cement particles and the fluidity of cement paste by mini-slump spread testing method were increased. When main chain of PC was methacrylic acid, a larger amount was adsorbed on the cement particles. PCs with acrylic acid as main chain showed higher dispersing power. However, it was confirmed that PCs with dicarboxylic acids(maleic anhydride, itaconic acid) didn't have good adsorption and dispersibility.

Design and Evaluation of a Lung Assist Device for Patients with Acute Respiratory Syndrome using Hollow Fiber Membranes (중공사 막을 이용한 급성호흡곤란증후군 환자용 폐 보조 장치의 설계와 평가)

  • Lee, Sam-Cheol;Kwon, O-Sung;Kim, Ho-Cheol;Hwang, Young-Sil;Lee, Hyun-Cheol
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.224-232
    • /
    • 2005
  • The use of the lung assist device (LAD) would be well suited for acute respiratory failure (ARF) patients, combining the simplicity of mechanical ventilation with the ability of extracoporeal membrane oxygenators (ECMO) to provide temporary relief for the natural lungs. This study's specific attention was focused on the effect of membrane vibration in the LAD. Quantitative experimental measurements were performed to evaluate the performance of the device, and to identify membrane vibration dependence on blood hemolysis. We tried to decide upon excited frequency band of limit hemolysis when blood hemolysis came to through a membrane vibration action. The excited frequency of the module type 5, consisted of 675 hollow fiber membranes, showed the maximum gas transfer rate. We concluded that the maximum oxygen transfer rate seemed to be caused by the occurrence of maximum amplitude and the transfer of vibration to hollow fiber membranes. It was excited up to $25{\pm}5$ Hz at each blood flow rate of module type 5. We found that this frequency became the 2nd mode resonance riequency of the flexible in blood flow. Blood hemolysis was low at the excited frequency of $25{\pm}5$ Hz. Therefore, we decided that limit hemolysis frequency of this LAD was $25{\pm}5$ Hz.

Design of a Double-Faced Monopole Antenna Using the Coupling Effect of Induced Currents (유도 전류의 커플링 효과를 이용한 모노폴 안테나 설계)

  • Choi, Young;Lee, Seungwoo;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1327-1336
    • /
    • 2012
  • In this paper, the dual-faced monopole antenna, which is arranged by numerous rectangular ring patches in sequence for the multi-bands is proposed. The ring type structure of the patch can be increased the bandwidth. Therefore the bandwidth and beam width are improved by using multiple arrayed patches. When the ring type patches are inserted serially, the resonance frequencies are occurred by the current flow from the first ring patch. It is possible because the gap between the patches is very narrow. In addition, if the patches are composed on the same plane as the feed-line, fabrication could be very difficult because the gap between the patches is extremely narrow. The thickness and permittivity of the antenna, moreover, are very important parameters because both sides of the substrate are used. We finally found the optimal thickness and permittivity to generate the coupling effect by simulation. All patches are consisted of 4-steps which the patch size was decreased 85 % by each step. In conclusion, the resonant frequency bands are 1.75~2.6 GHz(850 MHz), 3.24~3.46 GHz(220 MHz), 3.8~4.0 GHz(200 MHz), and 4.4~4.9 GHz(500 MHz).

Acromion Morphology in Coronal and Sagittal Plane; Correlation with Rotator Cuff Syndrome (관상면과 시상면에서의 견봉 형태와 회전근개 파열의 연관성)

  • Jo, Chris H.;Kim, Jung-Taek;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baek;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.126-136
    • /
    • 2009
  • Purpose: We evaluated the correlation of the anatomic parameters of the acromion those represent on the magnetic resonance image (MRI) of impingement syndrome. Materials and Methods: From June, 2004 to December, 2005, 71 cases were surgically proven to be impingement syndrome, and the anterior acromial hooking angle, the lateral acromial hooking angle (AAHA and LAHA) and the acromial hooking index (AHI: the sum of the AAHA and LAHA) were compared to 16 control cases. At the same period, 55 cases were surgically proven to be partial or full thickness rotator cuff tear, and age, gender and twelve anatomic parameters, including the acromial type, the acromial angle, the anterior covering, the acromial slope, the AAHA, the lateral acromial angle, the acromial torsional angle, the lateral acromial angulation, the LAHA, the lateral covering, the acromiohumeral distance and the AHI were assessed. Results: The AAHA and AHI were increased as impingement syndrome proceeded. The acromial type and acromial angle, and the AAHA, LAHA and AHI showed significant differences between the controls and the rotator cuff tear patients on univariant analysis. On multivariant analysis, gender was most strongly correlated with rotator cuff tear. Age, AAHA and the acromial angle showed similar correlation, respectively. Conclusion: The coronal acromial shape is correlated with rotator cuff tear, and it is important to correct the lateral acromial shape when performing acromioplasty.

Long-Period Wave Oscillations in Sokcho Harbor and Cheongcho Lagoon (1. Field Measurements and Data Analyses) (속초항과 청초호의 부진동 특성 (1. 현장관측과 자료 분석))

  • 정원무;박우선;김규한;채장원;김지희
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.1
    • /
    • pp.51-64
    • /
    • 2002
  • To investigate long-period wave responses in Sokcho Harbor and Cheongcho lagoon, field measurements were made for long-and short-period waves and current velocities using a Directional Waverider, a ultrasonic-type wave gauge, four pressure-type wave gauges, and a current meter. From the data analysis, it was found that the Helmholtz resonant periods of Sokcho Harbor and Cheongcho lagoon are about 13.6 and 54.5 minutes, respectively, and the dominant period of wave induced current in the passage between Sokcho Harbor and Cheongcho lagoon is about 55.2 minutes which depends on Helmholtz resonant condition of the Cheongcho lagoon. It was also found that the energy level of the far-infra-gravity waves during storm conditions is very high compared with that during calm sea conditions. To investigate relationships between far-infra-gravity waves and short-period waves at offshore station, regression analyses were carried out especially for 1) heights, 2) periods, 3) direction and height, 4) height and period between short-and far-infra-gravity waves, respectively. The results showed that the long-period wave height is highly correlated with the short-period wave height. However, no special trend was found for the other relations. In the future far-infra-gravity wave heights on return period around Sokcho Harbor region can be suggested by using extreme value analyses of long term measured data.

ICT based Wireless Power Transmission System Development (ICT 기반의 무선전력전송 시스템 개발)

  • Lee, Jong-Hee;Bang, Junho;Chun, Hyun-Jun;Seo, Beom-Geun;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • Recently, wireless power transmission has attracted much interest and is the subject of much research in industry and academia. As its name implies, it is a technology which involves transferring power without wires. This paper presents the design of an ICT-based wireless power transmission system. The proposed system consists of a wireless transceiver unit and high-efficiency coil unit, which can increase both the transmission efficiency and the effective power distance. In particular, the wireless transceiver unit was designed to work with the ICT technique to enable real-time remote monitoring. Also, studies were done relating to the effect of reducing the standby power. The optimal frequency of IGBT devices used in industrial wireless power systems of 20[KHz] was utilized. The values of $23.9[{\mu}H]$ and $2.64[{\mu}F]$ were selected for L and C, respectively, through many field experiments designed to optimize the system design. In addition, an output current controlling algorithm was developed for the purpose of reducing the standby power. The results presented in this paper represent a 75[%] to 85[%] higher power transmission efficiency with a 10[%] increase in the effective power transmission distance compared with the existing systems. As a result, the proposed system exhibits a lower standby power and maintenance costs. Also, the designed wireless transceiver unit facilitates fault detection by means of user acquired data with the development of the ICT applied program.

A Study of brain Atlases in Hippocampus Volume Measurement Using IBASPM (IBASPM을 이용한 해마체적 측정에서 뇌 Atlases에 대한 고찰)

  • Kim, Ju-ho;Lee, Ju-won;Kim, Seong-hu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.981-984
    • /
    • 2014
  • Volumetric measurement of hippocampus using IBASPM, the 20's normal adults 10 people's brain images were acquired in order to assess the changes according to the type of the Atlas. Images was obtained using MPRAGE of a 3-D gradient echo pulse sequence on Head matrix coil of 1.5T MRI system. The results of Paired t-test using obtained volume of hippocampus depending on the type of the Atlas, Atlas69-Altas84, Atlas69-Atlas116(p=0.729, 0.729) in the left hippocampus and Atlas69-Atlas84, Atlas69-Atlas116(p=0.219, 0.219) in right hippocampal formation were no significant differences but in the area except this, there was significant difference(p=0.000). The volume of the hippocampus using Atlas84 and Atlas116, represented the same value and there was no significant difference. In the image analysis using the overlay of atlas image and original image, Atlas71 could be found that the area of hippocampus did mismatch. In the case of atlas used in this study, because it has been developed by the westerners, there are differences between brain of asian. It would be needed to development of new Atlas for high accuracy measurement of the volume of hippocampus.

  • PDF

3-Dimensional Numerical Analysis of Air Flow inside OWC Type WEC Equipped with Channel of Seawater Exchange and Wave Characteristics around Its Structure (in Case of Regular Waves) (해수소통구를 구비한 진동수주형 파력발전구조물 내에서 공기흐름과 구조물 주변에서 파랑특성에 관한 3차원수치해석(규칙파의 경우))

  • Lee, Kwang Ho;Lee, Jun Hyeong;Jeong, Ik Han;Kim, Do Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.6
    • /
    • pp.242-252
    • /
    • 2018
  • It is well known that an Oscillating Water Column Wave Energy Converter (OWC-WEC) is one of the most efficient wave absorber equipment. This device transforms the vertical motion of water column in the air chamber into the air flow velocity and produces electricity from the driving force of turbine as represented by the Wells turbine. Therefore, in order to obtain high electric energy, it is necessary to amplify the water surface vibration by inducing resonance of the piston mode in the water surface fluctuation in the air chamber. In this study, a new type of OWC-WEC with a seawater channel is used, and the wave deformation by the structure, water surface fluctuation in the air chamber, air outflow velocity from the nozzle and seawater flow velocity in the seawater channel are evaluated by numerical analysis in detail. The numerical analysis model uses open CFD code OLAFLOW model based on multi-phase analysis technique of Navier-Stokes solver. To validate model, numerical results and existing experimental results are compared and discussed. It is revealed within the scope of this study that the air flow velocity at nozzle increases as the Ursell number becomes larger, and the air velocity that flows out from the inside of the air chamber is larger than the velocity of incoming air into the air chamber.