• Title/Summary/Keyword: Resonance Type

Search Result 1,093, Processing Time 0.025 seconds

Fabrication of Nickel-based Piezoelectric Energy Harvester from Ambient Vibration with Micromachining Technology (마이크로 머시닝 기술을 이용한 니켈기반의 압전 진동형 에너지 하베스터 제작)

  • Cha, Doo-Yeol;Lee, Jai-Hyuk;Chang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.1
    • /
    • pp.62-67
    • /
    • 2012
  • Owing to the rapid growth of mobile and electronic equipment miniaturization technology, the supply of micro mobile computing machine has been fast raised. Accordingly they have performed many researches on energy harvesting technology to provide promising power supply equipment to substitute existing batteries. In this paper, in order to have low resonance frequency for piezoelectric energy harvester, we have tried to make it larger than before by adopting nickel that has much higher density than silicon. We have applied it for our energy harvesting actuator instead of the existing silicon based actuator. Through such new concept and approach, we have designed energy harvesting device and made it personally by making with micromachining process. The energy harvester structure has a cantilever type and has a dimension of $10{\times}2.5{\times}0.1\;mm^3$ for length, width and thickness respectively. Its electrode type is formed by using Au/Ti of interdigitate d33 mode. The pattern size and gap size is 50 ${\mu}m$. Based on the measurement of the nickel-based piezoelectric energy harvester, it is found to have 778 Hz for a resonant frequency with no proof mass. In that resonance frequency we could get a maximum output power of 76 ${\mu}W$ at 4.8 $M{\Omega}$ being applied with 1 g acceleration.

Comparison between cone beam computed tomography and magnetic resonance imaging of the temporomandibular joint (측두하악관절에 대한 cone beam형 전산화단층영상과 자기공명영상의 비교)

  • Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.3
    • /
    • pp.153-161
    • /
    • 2008
  • Purpose : To compare and evaluate the diagnostic ability of cone beam computed tomography (CBCT) and magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ). Materials and Methods : CBCT and MRI of 46 TMJs of 23 patients with TMJ disorders were evaluated. They were divided into 3 groups according to the position of the articular disc of the TMJ at closed mouth position and the reduction of the disc during open mouth position on MRI: no disc displacement group (NDD), disc displacement with reduction group (DDR), and disc displacement without reduction group (DDWR). With PACS viewing soft-wares, position of mandibular condyle in the articular fossa, osseous change of mandibular condyle, shape of articular fossa, and mediolateral and anteroposterior dimensions of mandibular condyle were evaluated on CBCT and MRI. Each value was tested statistically. Results : The position of mandibular condyle in the articular fossa were concentric in the NDD, DDR, and DDWR of CBCT and NDD of MRI. However, condyle was positioned posteriorly in DDR and DDWR of MRI. Flattening, sclerosis and osteophyte of the mandibular condyle were much more apparent on DDR of CBCT than MRI. And the erosion of the condyle was much more apparent on DDWR of MRI than CBCT. Box and Sigmoid types of articular fossa were found most frequently in DDR of MRI. Flattened type was found most frequently in DDR of CBCT and deformed type was found most frequently in DDWR of CBCT. No significant difference in mediolateral and anteroposterior dimensions were shown on CBCT and MRI. Conclusion : Since MRI and CBCT has unique diagnostic imaging ability, both modalities should be used together to supplement each other to evaluate TMJ.

  • PDF

Preoperative Magnetic Resonance Imaging Features Associated with Positive Resection Margins in Patients with Invasive Lobular Carcinoma

  • Jiyoung Yoon;Eun-Kyung Kim;Min Jung Kim;Hee Jung Moon;Jung Hyun Yoon;Vivian Y. Park
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.946-954
    • /
    • 2020
  • Objective: To investigate preoperative magnetic resonance imaging (MRI) findings associated with resection margin status in patients with invasive lobular carcinoma (ILC) who underwent breast-conserving surgery. Materials and Methods: One hundred and one patients with ILC who underwent preoperative MRI were included. MRI (tumor size, multifocality, type of enhancing lesion, distribution of non-mass enhancement [NME], and degree of background parenchymal enhancement) and clinicopathological features (age, pathologic tumor size, presence of ductal carcinoma in situ [DCIS] or lobular carcinoma in situ, presence of lymph node metastases, and estrogen receptor/progesterone receptor/human epidermal growth factor receptor type 2 status) were analyzed. A positive resection margin was defined as the presence of invasive cancer or DCIS at the inked surface. Logistic regression analysis was performed to determine pre- and postoperative variables associated with positive resection margins. Results: Among the 101 patients, 21 (20.8%) showed positive resection margins. In the univariable analysis, NME, multifocality, axillary lymph node metastasis, and pathologic tumor size were associated with positive resection margins. With respect to preoperative MRI findings, multifocality (odds ratio [OR] = 3.977, p = 0.009) and NME (OR = 2.741, p = 0.063) were associated with positive resection margins in the multivariable analysis, although NME showed borderline significance. Conclusion: In patients with ILC, multifocality and the presence of NME on preoperative breast MRI were associated with positive resection margins.

Diagnostic Accuracy of Magnetic Resonance Imaging Features and Tumor-to-Nipple Distance for the Nipple-Areolar Complex Involvement of Breast Cancer: A Systematic Review and Meta-Analysis

  • Jung Hee Byon;Seungyong Hwang;Hyemi Choi;Eun Jung Choi
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.739-751
    • /
    • 2023
  • Objective: This systematic review and meta-analysis evaluated the accuracy of preoperative breast magnetic resonance imaging (MRI) features and tumor-to-nipple distance (TND) for diagnosing occult nipple-areolar complex (NAC) involvement in breast cancer. Materials and Methods: The MEDLINE, Embase, and Cochrane databases were searched for articles published until March 20, 2022, excluding studies of patients with clinically evident NAC involvement or those treated with neoadjuvant chemotherapy. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Two reviewers independently evaluated studies that reported the diagnostic performance of MRI imaging features such as continuity to the NAC, unilateral NAC enhancement, non-mass enhancement (NME) type, mass size (> 20 mm), and TND. Summary estimates of the sensitivity and specificity curves and the summary receiver operating characteristic (SROC) curve of the MRI features for NAC involvement were calculated using random-effects models. We also calculated the TND cutoffs required to achieve predetermined specificity values. Results: Fifteen studies (n = 4002 breast lesions) were analyzed. The pooled sensitivity and specificity (with 95% confidence intervals) for NAC involvement diagnosis were 71% (58-81) and 94% (91-96), respectively, for continuity to the NAC; 58% (45-70) and 97% (95-99), respectively, for unilateral NAC enhancement; 55% (46-64) and 83% (75-88), respectively, for NME type; and 88% (68-96) and 58% (40-75), respectively, for mass size (> 20 mm). TND had an area under the SROC curve of 0.799 for NAC involvement. A TND of 11.5 mm achieved a predetermined specificity of 85% with a sensitivity of 64%, and a TND of 12.3 mm yielded a predetermined specificity of 83% with a sensitivity of 65%. Conclusion: Continuity to the NAC and unilateral NAC enhancement may help predict occult NAC involvement in breast cancer. To achieve the desired diagnostic performance with TND, a suitable cutoff value should be considered.

Review for the Helical coil type and Spiral coil type in a mid range Wireless Power Transfer System (근거리 무선전력전송용 헬리컬 코일과 스파이럴 코일에 대한 고찰)

  • Park, Jae-Hyun;Yang, Hae-Youl;Kim, Chang-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.11-12
    • /
    • 2011
  • In electromagnetic coupled resonance(ECR) WPT system, the main key for wireless power transmission is the design method of the ECR coils. The ECR coils is classified to the helical coil(3D) type and the spiral coil(2D) type as a coil structure. The pattern of the spiral coil type has been studied in favor of commercialization. In this paper, the design characteristics of the helical coil and the spiral coil is considered using a Vector Network Analyzer. It is analyzed according to the distance of coupling coefficient between the ECR coils. Also, It is analyzed for the relationships such as the maximum transmission efficiency and the resonant frequency depending on the distance between the coils.

  • PDF

A Study on the Mode Conversion Type-Single Resonance Mode Ultrasonic Motor Using Bolt Tightened Langevin Type Vibrator (볼트조임 란쥬반형 진동자를 이용한 모드변환형-단일공진모드 초음파 모터에 관한 연구)

  • 이재형;박태곤
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.123-127
    • /
    • 2004
  • Mode conversion type ultrasonic rotary motor using bolt tightened Langevin type vibrator was studied. Driving frequency of the motor, displacements and elliptical trajectories at tip of the coupler were simulated by finite element analysis program (ANSYS). Speed and torque of the fabricated motor were measured as functions of input voltage and load. As results, from FEA the driving frequency of 40.8[kHz] and useful elliptical trajectories were found. Fabricated motor rotated clockwise at frequency of 38.2[kHz]. Speed and torque of the motor were increased when the input voltage was increased. Maximum speed, torque and efficiency were 75[rpm], 0.14[Nm] and 6.28[%], respectively.

Analysis and Fabrication of the Mode Conversion Type Ultrasonic Motor Using Finite Element Method (유한요소법을 이용한 모드변환형 초음파 모터의 해석 및 제작)

  • Lee, Jae-Hyung;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.23-26
    • /
    • 2003
  • An ultrasonic motor is a motor which uses vibration -a type of elastic vibration- to obtain a driving force, which then drives the motor using friction. In this paper, mode conversion type - single resonance mode ultrasonic rotary motor that use langevin type ultrasonic vibrator was studied. This model was proposed for the first time by Japanese Kumada in 1985. In this study, finite element analysis (FEA) of a stator and bidirectional driving characteristic of a rotor was newly obtained. The amplitude and phase of displacement and elliptical trajectory of beam was confirmed by FEA The fabricated motor was operated to clockwise and counterclockwise in 40.8 [kHz] and 44.2 [kHz] respectively. But bidirectional driving characteristics did not coincide each other.

  • PDF

A Study on the Parameters Influence upon Automotive Neutral Gear Rattle (자동차 공회전시 기어 치타음에 영향을 미치는 파라미터에 관한 연구)

  • Hong, D.P.;Chung, T.J.;Ahn, B.M.;Jeon, B.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.2
    • /
    • pp.74-83
    • /
    • 1997
  • The non-periodic angular accelerations of engine are the major cause of gear rattle. This gear rattle is based on the existence of a backlash between the drive gear of input shaft and the free gear of output shaft in the gearbox. Especially, the neutral gear rattle have a very bad effect on the ride quality. Test-rig was constructed in order to evaluate the parameter influence upon the neutral gear rattle. Also, each different 4 type torsional characteristic of clutch was manufactured. Experimental conditions are the use of each different 4 type torsional characteristic of clutch and oil temperature variation in gearbox. In case of the same stiffiness of pre-damper type clutch at idling, the clutch of large hysteresis showed dam- ping effects at the 2nd input gear and the 2nd output gear. Also, the main-damper type clutch was shown to large resonance phenomenon at the 2nd input gear. Accordingly, main-damper type clutch was unapp- roriate at idling.

  • PDF

Magnetic Resonance Imaging Assessment of Acromion Morphology and Superior Displacement of the Humeral Head in the Impingement Syndrome (충돌 증후군에서 견봉 형태 및 상완골 두 상방 전위의 자기공명영상 분석)

  • Koo Bon Seop;Kim Kyung Chul;Oh Jung Hee
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.1
    • /
    • pp.28-34
    • /
    • 1999
  • Purpose: We studied magnetic resonance imaging of acromion morphology and superior displacement of the humeral head in the patients with diagnosis of rotator cuff impingement syndrome, and also documented the relationship of type Ⅲ acromion to the rotator cuff tear. Materials and Methods: We reviewed retrospectively 40 patients(40 shoulders) who had arthroscopic treatment for the diagnosis of stage II impingement or rotator cuff partial tear and did not have other risk lesions except acromion factor. The mean age was 48.7 years at operation. 21 men(2l shoulders), mean age of 26 years, were used as controls. Acromial type, tilt, and superior displacement of humeral head in sagittal plane, and acromial lateral angulation in coronal plane were measured. Four parameters of the patients were compared with those of control group. And then, the data were subdivided and analyzed with respect to acromial type and patient age in the impingement group. Student t test and multi-way ANOVA were used. Results: In impingement group, Farley's type I acromion, 33%, type Ⅱ, 38%, type Ⅲ, 27% and type Ⅳ, 2%. Superior displacement of humeral head( 4.8mm) were characteristic in the impingement group compared with the control group(1.3mm)(p<0.05). But acromial tilt and lateral angulation were not statistically different. In the analysis of the impingement group, the change of 4 parameters was not significant with respect to age(p>0.05), but lateral angulation in type I acromion(18 degree) and superior displacement of humeral head in type Ⅲ acromion(6.3mm) were significantly increased(p<0.05). All 4 parameters were not different between two subdivided types of type Ⅲ acromion. Conclusion: All types of acromian and large lateral angulatian cauld develop impingement syndrame, but acromial tilt was nat risk factar. Appearance of type Ⅲ acromian and increased superiar displacement of humeral head were characteristic findings in the impingement syndrame. Superiar displacement of humeral head as a result of degenerative change of rotatar cuff was probably primary cause far impingement. The type Ⅲ acromian might be an acquired farm, which cauld be expected to accelerate the tear of rotatar cuff as a cansequence.

  • PDF

Power Transmission Mechanism and Data Communication of the Dosimeter using Contactless Powerless Transmission (선량계의 무선전력 전송 메카니즘과 데이터 통신 시스템 구현)

  • Lee, Seung-Min;Chung, Sung-In;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.814-819
    • /
    • 2010
  • This study proposes the antenna circuit design for the transmitting wireless power, the development of the RF non-contact type Dosimeter. That is, the study designed the optimization and numerical analysis of the antenna circuit for the antenna design of 13.56MHz over the frequency bands for transmitting wireless power. We studied the needed items in the existing RF type Dosimeter with battery to implement the wireless power non-contact Dosimeter within the battery. We compared to the real measurement value as calculating the value of the inductance and capacitance through the numerical analysis for the antenna LC resonance using the theory of the electromagnetic induction method. This method to drive low power is designed to simplify the circuit and to improve the efficiency of the rectifier. We convince our research contributes not only to understand the simplified circuit and miniaturization, but also to help the design and application technology of the wireless power transmit system which is received power supply with wireless.