• Title/Summary/Keyword: Resonance Frequency Shift

Search Result 85, Processing Time 0.026 seconds

Development of the Line Scan Diffusion Weighted Imaging at Low Tesla Magnetic Resonance Imaging System (저자장 자기공명영상시스템에서 선주사확산강조영상기법 개발)

  • Hong, Cheol-Pyo;Lee, Dong-Hoon;Lee, Do-Wan;Lee, Man-Woo;Paek, Mun-Young;Han, Bong-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.31-38
    • /
    • 2008
  • Line scan diffusion weighted imaging (LSDI) pulse sequence for 0.32 T magnetic resonance imaging (MRI) system was developed. In the LSDI pulse sequence, the imaging volume is formed by the intersection of the two perpendicular planes selected by the two slice-selective $\pi$/2-pulse and $\pi$-pulse and two diffusion sensitizing gradients placed on the both side of the refocusing $\pi$-pulse and the standard frequency encoding readout was followed. Since the maximum gradient amplitude for the MR system was 15 mT/m the maximum b value was $301.50s/mm^2$. Using the developed LSDI pulse sequence, the diffusion weighted images for the aqueous NaCl solution phantom and triacylglycerol solution phantom calculated from the line scan diffusion weighted images gives the same results within the standard error range (mean diffusivities = $963.90{\pm}79.83({\times}10^{-6}mm^2/s)$ at 0.32 T, $956.77{\pm}4.12({\times}10^{-6}mm^2/s)$ at 1.5 T) and the LSDI images were insensitive to the magnetic susceptibility difference and chemical shift.

  • PDF

Highly sensitive and selective detection of cyanide in aqueous solutions using a surface acoustic wave chemical sensor (표면음향파 화학센서를 이용한 수용액 중 시안화이온의 선택적인 고감도 검출)

  • Lee, Soo Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.473-479
    • /
    • 2016
  • We report a highly selective and sensitive 200 MHz Surface Acoustic Wave (SAW) sensor that can detect cyanide ion in aqueous solution using surface immobilized thioester molecules in combination with gold nanoparticles (AuNPs). To construct the sensor device, a monolayer of thioester compound was immobilized on the SAW sensor surface. At the sensor surface, hydrolysis of thioester group by nucleophilic addition of cyanide occurred and the resulting free thiol unit bound to AuNP to form thiol-AuNP conjugate. For the signal enhancement, gold staining signal amplification process was introduced subsequently with gold (III) chloride trihydrate and reducing agent, hydroxylamine hydrochloride. The SAW sensor showed a detection ability of $17.7{\mu}M$ for cyanide in aqueous solution and demonstrated a saturation behavior between the frequency shift and the concentration of cyanide ion. On the other hand, our SAW sensor had no activities for other anions such as fluoride ion, acetate ion and sulfate ion, moreover, no significant interference observed by other anions. Finally, all the experiments were carried out in-house developed sensor and fluidics modules to obtain highly reproducible results.

A Study on the Intenna Based on PIFA with Multi Element (Mulit Element를 이용한 PIFA 구조의 Intenna에 관한 연구)

  • Lim, Yo-Han;Chang, Ki-Hun;Yoon, Young-Joong;Kim, Yong-Jin;Kim, Young-Eil;Yoon, Ick-Jae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.784-795
    • /
    • 2007
  • In this thesis, the Multi element antenna with wideband and enhanced gain characteristic is proposed to operate at both frequency range from 824 MHz to 896 11Hz for the CDMA and frequency range from 908.5 MHz to 914 MHz for the RFID band. The proposed antenna has tile size of $35{\times}15{\times}5mm^3$ in order to put it in the A model of S company and each element of the proposed antenna is folded to obtain the minimum size. To obtain the antenna with wideband and high gain characteristic, the radiator of the antenna is divided into 4 elements. As a result, bandwidth of the proposed antenna become broader and lower center frequency is appeared due to increased and lengthened current path. Moreover, the enhanced gain characteristic is verified because divided element structure that induct uniform current distribution can get increased antenna efficiency. To attain more uniform current distribution, modified structure of the feeding point that can deliver currents directly is designed. The antenna that alters the feeding structure has higher gain value. Each element is folded to increase the current paths considering the current directions to attain the miniaturization of the antenna. To measure the handset antenna, the handset case must be considered. Even though antenna is designed for predicted characteristic, the resonance frequency is shifted and antenna gain is deteriorated at predicted frequency while antenna is set in the handset case. 1.08 GHz of the resonant frequency is determined after frequency shift from 150 MHz to 200 MHz is confirmed and the maximum gain is measured as 3.1 dBi while antenna is not set in the handset. In case handset case is considered, the experimental results show that the impedance bandwidth for VSWR<2 is from 0.824 GHz to 0.936 GHz(110 MHz). This result appears that the proposed antenna can cover both CDMA and RFID band at once. The measured gain is from -3.4 dBi to -0.5 dBi and it has omni-directional pattern practically.

Structural and Microwave Dielectric Properties of $La(Mg_{1/2}Ti_{1/2})O_3$ Ceramics ($La(Mg_{1/2}Ti_{1/2})O_3$ 세라믹스의 구조 및 고주파 유전 특성 연구)

  • Yeo, Jae-Hyun;Baek, Jong-Hu;Nham, Sahn;Lee, Hwack-Joo;Park, Hyun-Min;Byun, Jae-Dong
    • Korean Journal of Materials Research
    • /
    • v.9 no.9
    • /
    • pp.943-947
    • /
    • 1999
  • The crystal structure and the microwave dielectric properties of $La(Mg_{1/2}Ti_{1/2})O_3$ ceramics have been investigated. $La(Mg_{1/2}Ti_{1/2})O_3$ has the 1:1 ordered monoclinic structure with the lattice parameters of $a = 5.5467(3){\AA}, b = 5.5616(3){\AA}, c = 7.8426(5) {\AA} and \beta = 89.9589 (2)^{\circ}$ The spacegroup of LMT is $P2_1/n$. Monoclinic LMT has the in­phase and anti-phase tilting of octahedra with the $a^_a^_c^_$ tilting system. Anti-parallel shift of A-site cations was also found in LMT. The relative density of the specimens sintered above $1600^{\circ}C$ was ranged between 95 % and 96 % of the theoretical density and the dielectric constant of specimens was about 28. The highest $Q\timesf$ achieved in this investigation was 63,100 for the specimen sintered at $1630^{\circ}C$ for 5 hr. Temperature coefficient of resonance frequency ranged from $>-74 ppm/^{\circ}C ~ -79 ppm/^{\circ}C$.

  • PDF

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF