• 제목/요약/키워드: Resonance Coil

검색결과 377건 처리시간 0.023초

자기공명영상시스템에서의 의료용 리드선의 전자기적 호환 연구 (Electromagnetic Compatibility Study of a Medical Lead for MRI Systems)

  • 유형석
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2019-2022
    • /
    • 2016
  • In the presence of an electrically conducting medical lead, radio frequency (RF) coils in magnetic resonance imaging (MRI) systems may concentrate the RF energy and cause tissue heating near the lead. A novel design for a medical lead to reduce this heating by introducing pins in the lead is presented. Peak 10 g specific absorption rate (SAR) in heart tissue, an indicator of heating, was calculated and compared for both conventional (Medtronic) lead design and our proposed design. Remcom XFdtd software was used to calculate the peak SAR distribution in a realistic model of the human body. The model contained a medical lead that was exposed to RF magnetic fields at 64 MHz (1.5 T), 128 MHz (3 T) and 300 MHz (7 T) using a model of an MR birdcage body coil. The proposed design of adding pins to the medical lead can significantly reduce the heating from different MRI systems.

Development of 7-Year-Old Korean Child Model for Computational Dosimetry

  • Lee, Ae-Kyoung;Byun, Jin-Kyu;Park, Jin-Seo;Choi, Hyung-Do;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • 제31권2호
    • /
    • pp.237-239
    • /
    • 2009
  • A whole-body voxel model of a 7-year-old male volunteer was developed from 384 axial magnetic resonance images (MRIs). The MRIs were acquired with intervals of 3 mm for the entire body in a body coil. In order to reduce the MRI acquisition time for the child, the repetition and echo times under T1 weighted image were chosen to be 566 ms and 8 ms, respectively. The MRIs were classified according to 30 types of tissues with known electrical parameters. The developed voxel model was adjusted to the physical average of 7-year-old Korean boys. The body weight of the adjusted model, calculated with the mass tissue densities, is within a 6% difference from the 50th percentile weight.

  • PDF

저주파수 진동형 전자기식 마이크로 발전기의 설계 및 해석 (Design and Analyses of Vibration Driven Electromagnetic Energy Harvester with High Power Generation at Low Frequency)

  • 이병철;정귀상
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.102-106
    • /
    • 2011
  • This paper presents a design and analysis of an electromagnetic micro generator which can convert low frequency vibration energy to electrical power. The design aspects of the micro generator comprised planar spring, Cu coil and a permanent magnet(NdFeB). Threetype spring designs and four materials(Parylene, FR-4, Cu and Si) were compared to find resonance frequency. It was found that the resonance frequency will be changed according to the spring shape and material. Mechanical and magnetic parameters had been adjusted to optimize the output power through a comprehensive theoretical study.

Performance and analysis of wireless power charging system from room temperature to HTS magnet via strong resonance coupling method

  • Chung, Y.D.;Lee, C.Y.;Lee, S.Y.;Lee, T.W.;Kim, J.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권1호
    • /
    • pp.41-45
    • /
    • 2016
  • The technology of supplying the electric power by wireless power transfer (WPT) is expected for the next generation power feeding system since it can supply the power to portable devices without any connectors through large air gap. As such a technology based on strongly coupled electromagnetic resonators is possible to deliver the large power and recharge them seamlessly; it has been considered as a noble option to wireless power charging system in the various power applications. Recently, various HTS wires have now been manufactured for demonstrations of transmission cables, motors, MAGLEV, and other electrical power components. However, since the HTS magnets have a lower index n value intrinsically, they are required to be charged from external power system through leads or internal power system. The portable area is limited as well as the cryogen system is bulkier. Thus, we proposed a novel design of wireless power charging system for superconducting HTS magnet (WPC4SM) based on resonance coupling method. As the novel system makes possible a wireless power charging using copper resonance coupled coils, it enables to portable charging conveniently in the superconducting applications. This paper presented the conceptual design and operating characteristics of WPC4SM using different shapes' copper resonance coil. The proposed system consists of four components; RF generator of 370 kHz, copper resonance coupling coils, impedance matching (IM) subsystem and HTS magnet including rectifier system.

MAGNETIC RESONANCE IMAGING을 이용한 악관절 원판 천공 진단 (PERFORATION OF THE TEMPOROMANDIBULAR JOINT MENISCUS: DIAGNOSED BY MAGNETIC RESONANCE IMAGING)

  • Kim, Houng-Gon;Dolan, Eward;Vogler, James B.;Nokes, Steven R.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제11권2호
    • /
    • pp.11-18
    • /
    • 1989
  • 최근의 악관절(TMJ) 방사선학적 진단에 있어 많은 발전과 진단방법이 고안돼어 왔다. 또한 새로운 외과적 술식의 발달로 인하여 악관절내장증(Internal Derangement)의 보다 정확한 진단을 요하게 되었다. 가장 새로운 진단방법으로 핵자기공명촬영법(Magnetic Resonance Imaging:MRI)이 악관절내장증 진단 평가하는데 사용되어지고 있다. 핵자기공명촬영법은 surface coil을 이용하여 관절원판(meniscus)의 비정상적 변화를 효과적으로 진달할 수 있으며, 지금까지 이용되어오던 악관절조영술(arthrography)이나 컴퓨터 단층촬영법(C-T scan)의 단점인, 관절내 조영제 주입이나 방사선 노출둥의 문제점을 배제할 수 있다. 본 연구는 악관절 핵자기공명촬영을 한 92명(184 joints)중 천공(perforation)으로 진단된 31 명 (39 joints)를 대상으로 하였으며, 핵자기공명촬영법의 취약점으로 지적되고 있는 악관절원판 천공 진단의 정확도를 측정하기 위하여 가역적 조사를 통해, 악관절원판 천공으로 진단되어 수술받은 15명(20 joints)에서 65%(13 joints)의 정확성을 확인하였다. 또한 핵자기공명촬영법을 통한 악관절원판 진단의 정확도를 높이기 위하여 condyle head의 퇴행성 변화, articular eminence의 변화, condyle spurring, bone to bone contact등의 경조직 변화와 meniscus의 discontinuity, meniscal deformity, loss of joint space, alternated bilaminar zone 등이 악관절원판 천공진단의 중요한 findings 임을 증명 하였다.

  • PDF

Preliminaly Result of Whole-body Slotted Tube Resonator for 3.0T MRI

  • Kim, Kyoung-Nam;Park, Bu-Sick;Chung, Sung-Taek
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.151-151
    • /
    • 2001
  • Purpose: 3.0 Tesla whole-body resonator provides a potential to have significant increase in imag quality and resolution in high resolution application such as cardiac, spine and extremit imaging. The aim of this study is to design an optimized 3.0T whole-body coil to produce high sensitivity and quality using slotted tube resonator.

  • PDF

감쇠진동계에 부착된 코일스프링과 오일댐퍼로 구성된 동흡진기

  • 최석창;안찬우;박일수;이희범
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.289-293
    • /
    • 1996
  • Vibration absorber is used to protect the primary system from steady-state harmonic disturbance. By attaching the absorber to the primary system which is modeled as a SDOF system, the new system becomes two DOF system. Depending on the driving frequency on the original system, the absorber needs to be carefully tuned, that is, to choose adequate value of the absorber mass and stiffness, so that the motion of the original mass is a minimum. This paper presents the effects of resonance frequency ratio and of vibration absorber with oil damper and coil spring for linear damped primary systems.

  • PDF

Rotter estimation of ″sum-of-squres″ to improve the reconstructed image quality in Sensitivity Encoding (SENSE)

  • Yun, Sung-Dae;Song, Myung-Sung;Chung, Jun-Young;Park, Hyun-Wook
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.72-72
    • /
    • 2003
  • In SENSE, division process is used in order to get a raw sensitivity map. This process requires denominator which is estimated by "sum-of-squres". However, this image does not have uniformbrightness because of the non-symmetrical property of RF coil arrays. Thus, this study is focused on better estimation of the denominator image.

  • PDF