• Title/Summary/Keyword: Resistive index

Search Result 25, Processing Time 0.038 seconds

Interference Effects on the Thickness of a Pulse Pressure Sensor Array Coated with Silicone (맥 센서 어레이(array)의 실리콘(silicone) 코팅 두께에 따른 센서 간 간섭효과)

  • Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.35-40
    • /
    • 2016
  • Pulse diagnosis is one of the representative diagnostic methods in Oriental medicine. In this study, a pulse pressure sensor array coated with silicone, which includes 6 piezo-resistive sensors and 1 thermistor, is fabricated for pulse measurement. It is necessary to coat the pulse sensor array with silicone to avoid the fracture or damage of pressure sensors when the sensor is in contact with the skin and a constant pressure is applied. However, the silicone coating on the pulse sensor array can cause signal interference among the sensors in the pulse sensor array. The interference number (IN), a calculation for expressing the degree of interference among channels, is changed according to the silicone thickness on the pulse sensor array. The IN is increased by a thick silicone coating, but the fabrication error, an important index for the mass production of the sensor array, is reduced by the thickness of the silicone coating. We propose that the thickness of the silicone on the pulse sensor array is an important consideration for the performance of the fabricated sensor and manufacturing repeatability.

The ultrasonographic estimate of renal arteries in the dog (개에 있어서 신장혈관의 초음파적 평가에 관한 연구)

  • Kang, Suk-jae;Bae, Chun-sik;Kim, Hwi-yool;Chang, Kyung-jin
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.1
    • /
    • pp.230-239
    • /
    • 1999
  • Digital color doppler ultrasonographic system(DCDUS) has a lot of diagnostic functions. One of these is a detection of low velocity vessels in the organs of abdominal cavity. The purpose of study was to determine the clinical usefulness of DCDUS. Interlobar artery resistive index(RI), pulsatility index(PI) and systolic diastolic ratio(SDr) were measured for diagnosis of obstructed urinary tract. RI, PI and SDr were a measure of intrarenal blood flow impedance. This study was consisted of 2 groups. The normal group was studied in 16 normal adult dogs and the study group was studied 7 dogs with surgically induced, unilateral ureteral obstruction. In the study group, parameters were checked in normal condition and on 1, 2, 3, 5, 7 and 10th day after ligation. The result were summarized as follows. In the normal group, RI, PI and SDr of the left kidney was $0.65{\pm}0.04$, $1.25{\pm}0.12$ and $292.45{\pm}29.40$, respectively. RI, PI and SDr of the right kidney were $0.64{\pm}0.05$, $1.28{\pm}0.20$ and $282.25{\pm}37.26$, respectively. In the study group, RI of the left kidney induced ligation was increased significantly on 1, 2, 3, 5, 7 and 10th day. RI of the left kidney on 1, 2, 3, 5, 7 and 10th day were $0.75{\pm}0.05$, $0.71{\pm}0.03$, $0.74{\pm}0.04$, $0.74{\pm}0.02$, $0.73{\pm}0.02$ and $0.73{\pm}0.04$, respectively. PI of the left kidney was increased significantly on 1, 3, 5 and 7th day. PI of the left kidney on 1, 3, 5 and 7th day were $1.57{\pm}0.21$, $1.54{\pm}0.24$, $1.60{\pm}0.15$ and $1.60{\pm}0.26$, respectively. SDr of the left kidney increased significantly on 1, 2, 3, 5 and 7th day. SDr of the left kidney on 1, 2, 3, 5 and 7th day were $412.18{\pm}86.69$, $352.14{\pm}47.05$, $399.77{\pm}65.54$, $369.43{\pm}48.34$ and $365.57{\pm}22.46$, respectively(p<0.05). In the study group, RI of the left kidney was more increased than that of the right kidney on 1, 2, 3, 5, 7 and 10th day. PI of the left kidney was more increased than that of the right kidney on 1, 3, 5, and 7th day. SDr of the left kidney was more increased than that of the right kidney on 1, 2, 3, 5 and 7th day(p<0.05). RI was effective in the diagnosis of an acute unilateral ureteral obstruction. PI and SDr were insufficient in the diagnosis of an acute unilateral ureteral obstruction.

  • PDF

Clinical Study on 1 Case of Cervical Dystonia Treated by Korean Medicine and Transfer Energy Capacitive and Resistive (TECAR) Therapy (Transfer Energy Capacitive and Resistive (TECAR) Therapy와 한방치료를 병행한 경부 근 긴장성 사경 환자 증례 보고 1예)

  • Lee, Won-Jun;Yoon, Young-Suk;Kim, Jong-Ho;Lee, Keun-Jae;Kim, Mi-Hye;Ryu, Ho-Sun;Han, Su-Bin;Park, Byung-Hak;Son, Jae-Min;Lee, Nam-Woo;Han, Jeong-Hun;Seo, Hye-Jin;Kim, Ji-Hoon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.29 no.4
    • /
    • pp.109-115
    • /
    • 2019
  • Cervical dystonia (CD) is a disorder characterized by sustained or intermittent, involuntary muscle contractions which cause twisting, repetitive movements and abnormal postures. In this case report, a CD patients was treated with transfer energy capacitive and resistive (TECAR) therapy and conventional Korean medicine, which consists of acupuncture, Chuna manual medicine, pharmacopuncture and herbal medicine. For outcome measures, this study evaluated Cobb's angle, EuroQol five dimension scale (EQ-5D), numerical rating scale (NRS), neck disabillity index (NDI) and cervical range of motion. As a result, improvements were found in Cobb's angle ($18.65^{\circ}$ to $15.90^{\circ}$), EQ-5D score (0.808 to 0.862), NRS (5 to 3), NDI (16 to 8) and angle of cervical lateral bending ($15^{\circ}$ to $25^{\circ}$). In conclusion, this study shows that combined therapy of conventional Korean medicine treatment and TECAR therapy can be effective for CD patients.

Use of the Color Doppler Ultrasonography for the Evaluation of the Hemodynamic Changes of the Cranial Pancreaticoduodenal Arterial Flow in Experimentally Induced Acute Pancreatitis Dogs (실험적으로 유발된 급성 췌장염 견에서 컬러도플러 초음파를 이용한 전방 십이지장 동맥 혈류의 혈역학적 변화에 대한 평가)

  • Lee, Hae-Woon;Um, Ki-Dong;Sung, Yoon-Sang;Lee, Jung-Min;Lee, Jong-Won;Lee, Geun-Woo;Kim, Myung-Chul;Kim, Doo;Park, Sun-Il
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.334-340
    • /
    • 2003
  • For the study of the hemodynamic changes of the cranial pancreaticoduodenal arterial flow(cPDAF) in the dog with acute pancreatitis, acute pancreatitis was experimentally induced in 10 dogs by the injection of oleic acid into the accessory pancreatic duct. The parameters of cPDAF were measured by transcutaneous pulsed-wave Doppler ultrasonography. The hemodynamic changes included resistive indexe(RI), pulsatility index(PI) and maximum velocity (Vmax). Ultrasonographic scans were performed before the induction of pancreatitis and once daily for five days after the induction. The RI, PI and Vmax were increased with day as follows; the RI prior to induction was 0.625$\pm$0.096 (mean$\pm$SD), the PI was 1.117$\pm$0.289 and the Vmax was 0.349$\pm$0.094 m/s. After five days, the RI was 0.727$\pm$0.051 (p<0.0l), the PI was 1.480$\pm$0.284 (p<0.0l) and the Vmax was 0.585:$\pm$0.114 m/s (p<0.00l). These results show that there is some relation between the increase of the RI, PI and Vmax of cPDAF and the progress of acute pancreatitis in dogs. Therefore, the measurements of the hemodynamic changes of cPDAF may be a valuable technique for the evaluation of acute pancreatitis in dogs.

Analysis on Current Limiting Characteristics of the SFCL with Magnetically Coupled Two Coils and YBCO Coated Conductor Due to the Winding Direction and the Turn Number' Ratio Between Two Coils (직렬 연결된 두 코일과 YBCO Coated Conductor로 구성된 초전도 전류제한기의 권선방향과 권선 비에 따른 전류제한 특성 분석)

  • Lee, Dong-Hyeok;Du, Ho-Ik;Kim, Yong-Jin;Han, Byoung-Sung;Han, Sang-Chul;Lee, Jeong-Phil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.52-56
    • /
    • 2011
  • The ongoing Superconducting Fault Current Limiter(SFCL) development mainly has focused on the application of commercializaton and power system through combining with normal-conducting device, moving away from current-limiting method, which is solely dependant on the existing superconductor. Compared to the structural development above, on the other hand, the research on applying superconducting current-limiting element to SFCL, the heart of SFCL, still has a lot left to do, apart form traditional resistive type SFCL. In this study, we looked into the current limiting characteristic of SFCL using core and coil. YBCO coated conductor with stainless steel stabilizer layer was verified by the excellent of current-limiting element of the resistive type SFCL that has a high Jc and index as well as being superior in mechanical property. Also, we study temperature characteristics and resistance characteristics, max voltage, response time and current-limiting ability that can be an indicator as current-limiting element while applying to superconducting current-limiting element caused by variation of winding direction, winding ratio of SFCL using core and coil.

A Light Incident Angle Stimulated Memristor Based on Electrochemical Process on the Surface of Metal Oxide

  • Park, Jin-Ju;Yong, Gi-Jung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.174-174
    • /
    • 2014
  • Memristor devices are one of the most promising candidate approaches to next-generation memory technologies. Memristive switching phenomena usually rely on repeated electrical resistive switching between non-volatile resistance states in an active material under the application of an electrical stimulus, such as a voltage or current. Recent reports have explored the use of variety of external operating parameters, such as the modulation of an applied magnetic field, temperature, or illumination conditions to activate changes in the memristive switching behaviors. Among these possible choices of signal controlling factors of memristor, photon is particularly attractive because photonic signals are not only easier to reach directly over long distances than electrical signal, but they also efficiently manage the interactions between logic devices without any signal interference. Furthermore, due to the inherent wave characteristics of photons, the facile manipulation of the light ray enables incident light angle controlled memristive switching. So that, in the tautological sense, device orienting position with regard to a photon source determines the occurrence of memristive switching as well. To demonstrate this position controlled memory device functionality, we have fabricated a metal-semiconductor-metal memristive switching nanodevice using ZnO nanorods. Superhydrophobicity employed in this memristor gives rise to illumination direction selectivity as an extra controlling parameter which is important feature in emerging. When light irradiates from a point source in water to the surface treated device, refraction of light ray takes place at the water/air interface because of the optical density differences in two media (water/air). When incident light travels through a higher refractive index medium (water; n=1.33) to lower one (air; n=1), a total reflection occurs for incidence angles over the critical value. Thus, when we watch the submerged NW arrays at the view angles over the critical angle, a mirror-like surface is observed due to the presence of air pocket layer. From this processes, the reversible switching characteristics were verified by modulating the light incident angle between the resistor and memristor.

  • PDF

Estimation of joint and index dissipation in HTS tape (고온초전도 선재의 접합 및 인덱스손실 평가)

  • 김정호;임준형;장석헌;김규태;주진호;최세용;나완수;강형구;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.59-62
    • /
    • 2003
  • We fabricated two HTS closed coils by using resistive-joint method and the joint resistance of the coil was estimated by field decay technique at 77 K. In addition, we used the Runge-kutta method for the numerical analysis to estimate the decay properties. The joint resistances were evaluated as a function of critical current of HTS closed coil and external field strength of excitation coil. It was observed that joint resistance was independent of critical current and external field strength. It was estimated that joint resistance was 8.0$\times$10$^{-9}$ $\Omega$ to 11.9$\times$10$^{-9}$ $\Omega$ for coils of contact length for 7 cm.

  • PDF

ANALYSIS OF THE MUTUAL SELF-BIASED SHIELDED MAGNETO-RESISTIVE HEAD WITH TRANSMISSION-LINE MODEL(I)

  • Zhang, H.W.;Kim, H.J.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.4
    • /
    • pp.294-298
    • /
    • 1995
  • A shielded magnetoresistive (SMR) head which has double MR films and linearizes each other has been designed and studied by applying the transmission-line model. We have analyzed the yoke efficiency, bias efficiency and read efficiency of the SMR head. The read efficiency strongly depends on the height of the sensor and slightly on the other geometric parameters. The yoke and bias efficiencies vary with gap length, insulated layer thickness and relative permeability. A quasi-index reduction in the signal flux is observed when the displacement moves away from the medium.

  • PDF

Renal hemodynamics in dogs with experimental hydronephrosis treated with transarterial embolization of renal artery (신장동맥색전술을 실시한 개의 실험적 수신증의 혈동학)

  • Chang, Dongwoo
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.413-419
    • /
    • 2001
  • This study was performed to evaluate the renal hemodynamics using color Doppler ultrasonography in dogs with unilateral experimental hydronephrosis treated with transarterial embolization of the renal artery (TAE-RA). Experimental hydronephrosis was induced by ligation of unilateral ureter in 12 dogs. The mean resistive index (RI) value of kidney was significantly increased at 4, 9, 17 days after ligation of ureter. Unilateral hydronephrosis was established in 12 dogs at 17 days after ligation of ureter. Renal artery embolization was performed using selective catheterization in the hydronephrotic kidney of seven dogs and EKG, $SpO_2$body temperature, pulse, and respiratory rate were within normal ranges during procedures. There were no dogs expired after TAE-RA and no side effects associated with regurgitation of iohexol-ethanol solution. In color Doppler ultrasonographic findings, there was no blood flow into the embolized kidneys treated by TAE-RA, however, blood flow signal was found in contralateral normal kidney of dogs treated with TAE-RA compared to that of normal kidney in normal control group. It is concluded that TAE-RA does not affect the hemodynamics of contralateral normal kidney in dogs with experimental hydronephrosis and color Doppler ultrasonography is simple and non-invasive modality for the monitoring of the revascularization of the renal artery after TAE-RA.

  • PDF

A Study of Intracranial Hemodynamic Change with Aging (노화에 따른 두개내 혈류의 혈류 동력학적 변화에 관한 연구)

  • Kim Jong-Soon;Kim Byung-Jo;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.119-130
    • /
    • 2002
  • The purpose of this study was to evaluate hemodynamics of intracranial blood flow for obtain clinically useful reference values and assess cerebral hemodynamics change with aging. 81 normal Korean subjects(age, 14$\thicksim\∼\thicksim$70 years) examined who han no history of neurologic disease and the subjects divided into group A(age, 14$\∼$39 years), group B(age, 40$\∼$59 years) and group C(age, 60$\∼$70 years). Transcranial doppler was use for measured the maximum velocity(Vmax), mean velocity(Vmean), pulsatility index(PI), resistive index(RI), stenosis index(SI) and depth of sample volume. Vmax was 99.1 1cm/s, Vmean was 63.57cm/s, PI was 0.85, RI was 0.56, SI was 31.94 and depth of sample volume was 52.35 in middle cerebral artery. Vmax was 85.54cm/s, Vmean was 52.52cm/s, PI was 0.82, RI was 0.55, SI was 34.48 and depth of sample volume was 73.62 in anterior cerebral artery. Vmax was 75.45cm/s, Vmean was 45.60cm/s, PI was 0.82, RI was 0.58, SI was 36.14 and depth of sample volume was 62.35 in posterior cerebral artery. Vmax was 70.44cm/s, Vmean was 47.07cm/s, PI was 0.87, RI was 0.58, SI was 29.83 and depth of sample volume was 75.23 in basilar artery Vmax was 63.92, Vmean was 42.42, PI was 0.89, RI was 0.58, SI was 29.89 and depth of sample volume was 66.65 in vertebral artery. Vmax and Vmean was significantly decreased with increasing age in middle cerebral artery, anterior cerebral artery, posterior cerebral artery, basilar artery and vertebral artery And PI and RI was significantly increased with increasing age in basilar artery and vertebral artery. And I suggest that transcranial doppler sonography can be used as one of useful clinical tool for detection of cerebral hemodynamics.

  • PDF