• Title/Summary/Keyword: Resistive Shunt

Search Result 38, Processing Time 0.025 seconds

Characteristics of 15 kVA Superconducting Fault Current Limiters Using Thin Films (15 kVA급 박막형 초전도 전류제한기의 한류특성)

  • 최효상;현옥배;김혜림;황시돌
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.1058-1062
    • /
    • 2000
  • We investigated resistive superconducting fault current limites (SFCLs) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 A$\_$peak/, was produced and successfully tested at a 220 V$\_$rms/circuit. From the resistance increase, we estimated that the film temperature increased to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V$\_$rms/.

  • PDF

Simultaneous Quench Analysis of a Three-Phase 6.6 kV Resistive SFCL Based on YBCO Thin Films (YBCO 박막을 이용한 3상 6.6kV 항형 초전도 한류기의 동시Quench 분석)

  • Sim J;Kim H. R;Hyun O. B
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.46-51
    • /
    • 2004
  • We fabricated a resistive type superconducting fault current limiter (SFCL) of 3-phase $6.6 kV_{rms}$ / rating, based on YBCO thin films grown on sapphire substrates with a diameter off inch. Each element of the SFCL was designed to have the rated voltage of $600 V_{rms}$ $/35A_{rms}$. The elements produced a single phase with 8${\times}$6 components connected in series and parallel. In addition, a NiCr shunt resistor of 23 $\Omega$ was connected in parallel to each of them for simultaneous quenches between the elements. Prior to investigating the performance of the 3 phase SFCL, we examined the quench characteristics for 8 elements connected in series. For all elements, simultaneous quenches and equal voltage distribution within 10% deviation from the average were obtained. Based on these results, performance of the SFCL for single line-to-ground faults was investigated. The SFCL successfully limited the fault current of $10 kA_{ rms}$ below 816 $A_{peak}$ within 0.12 msec right after the fault occurred. During the quench process, average temperature of all components did not exceed 250 K, and the SFCL was totally safe during the whole operation.

  • PDF

Quench Characteristics of Resistive SFCL Elements in series (직렬 연결된 초전도 한류기의 퀜치 및 한류 특성)

  • Hyun, Ok-Bae;Choi, Hyo-Sang;Kim, Hye-Rim;Lim, Hae-Ryong;Kim, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.663-665
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters (SFCL) based on YBCO thin films grown on 2-inch diameter saphire substrates Two SFCLs with nearly identical properties were connected in series to investigate the simultaneous quench. There was a slight difference in the rate of voltage increase between two SFCL units when they were operated independently. This difference. however, resulted in significantly unbalanced power dissipation between the units. This imbalance was removed by connecting a shunt resistor to an SFCL in parallel. The appropriate values of the shunt resistances were $80{\Omega}$ at $75 V_{rms}$. $100{\Omega}$ at $100 V_{rms}$ and $110{\Omega}$ at $120 V_{rms}$, respectively. Increased power input at high voltages also reduced the initial imbalance in power dissipation. but with increase in film temperature to higher than 200 K.

  • PDF

Current and voltage loading tests off resistive SFCL

  • 최효상;현옥배;김혜림;황시돌;박권배
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.241-246
    • /
    • 2002
  • We have performed the current and voltage loading tests of resistive superconducting fault current limiters (SFCLS) based on $YBa_2$$Cu_3$$O_{7}$(YBCO) films with the diameter of 2 inch. The SFCL consists of meander-type YBCO stripes covered with 200 nm Au layer grown in situ for current shunt and heat dispersion at hot spots. The minimum quench current of an SFCL unit was about 25 Apeak. Seven SFCL units were connected in parallel fur the current load ing tests at power source of 100 $V_{rms}$ $/2,000A_{rms}$. This SFCL units had maximum limiting current of 170 Apeak during the fault instant and then successfully controlled the fault current below 100 Apeak within 1~2 msec after short circuit. Increased short current also reduced the quench completion time with little change of current limiting characterization. We connected six SFCL units in series fur the voltage loading tests at power source of $1,200 V_{rms}$/170 $A_{rms}$ at this time. The shunt resistors were inserted into each SFCL unit to eliminate power imbalance originated from serial connection of SFCL units. Each SFCL unit was quenched simultaneously during the fault condition. The current increased up to 40 $A_{peak}$ and decreased to 14 $A_{peak}$ after 3 cycles. Quench was completed within 1 msec after the fault. We confirmed operating characteristics of 140 kVA($120 A_{rms}$ $\times$ 1,200 $V_{rms}$) SFCL and presented the manufacturing possibility of 3.3 kV SFCL using 4 inch YBCO films.BCO films.lms.

  • PDF

Operating Characteristics of Superconducting Fault Current Limiters Connected in Series by Shunt Resistors (직렬연결된 초전도 한류기의 분로저항에 의한 동작특성)

  • Hyun, Ok-Bae;Choi, Hyo-Sang;Kim, Hye-Rim;Lim, Hae-Ryong;Kim, In-Seon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.11
    • /
    • pp.737-741
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters (SFCL) based on YBCO thin films grown on 2-inch diameter $Al_2O_3$ substrates. Two SFCLs with nearly identical properties were connected in series to investigate simultaneous quench. There was a slight difference in the rate of voltage increase between two SFCL units when they were operated independently. This difference resulted in significantly imbalanced power dissipation between the units. This imbalance was removed by connecting a shunt resister to an SFCL in parallel. The appropriate values of shunt resistance were 80 ${\Omega}$ at 75 $V_rms$ and 110 ${\Omega}$ at 120 $V_rms$, respectively. Increased power input at high voltages also reduced the initial imbalance in power dissipation, but with increase in film temperature to higher than 200 K.

  • PDF

Simultaneous quenching phenomena of resistive superconducting fault current limiter connected in series (직렬연결된 저항형 한류기의 동시퀜치 현상)

  • 최효상;김혜림;임해용;김인선;현옥배
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.91-94
    • /
    • 2000
  • We fabricated resistive super- conducting fault current limiters (SFCL) based on YBCO thin films grown on 2" diameter $Al_{2}O_{3}$ substrates. Two SFCLs with nearly identical properties. two SFCLs with nearly identical properties were connected in series to investigate simultaneous quenching. There was a difference of several half cycles in their quench starting time, although the difference was not more than 0.1 msec when they were operated separately. This imbalance was removed by connecting a shunt resistor to an SFCL in parallel. Increased power input at high voltages also reduced the initial imbalance in power dissipation. Further efforts on the simultaneous quench in SFCLs connected in series are on the way through methods such as the artificial control of quench speed.peed.

  • PDF

Generated heat decrease of resistive superconducting fault current limiter using diodes (Diode를 이용한 저항형 초전도 한류기의 열발생 저감방안)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.925-927
    • /
    • 2000
  • We fabricated a resistive superconducting fault current limiter of meander type based on a YBCO film. In order to disperse the heat generated at hot spots in the YBCO film the film was coated with a gold shunt layer. When diodes were inserted in the parallel circuit to restrict the temperature increase in the SFCL element by reducing power supply cycles, the voltage could be increased to $\sqrt{2}$ times with the same quench resistance at a half and full cycles.

  • PDF

Analysis of the Phase Angle for High Precision 10 A Calculable Shunt (초 정밀 10A Shunt 개발을 위한 위상각 해석)

  • Wijesinghe, W.M.S.;Park, Young-Tae;Ko, Kyoung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.977-978
    • /
    • 2007
  • The phase angle which is mainly depend on time constant $\tau$ of the calculable 10 A and 0.1 ${\Omega}ac/dc$ resistor has been analysed. The low values of resistors are usually inductive and time constant $\tau$ very large compare to high values of resistors. The numerical analysis has been shown that the time constant $\tau$ becomes zero when introduce the compensation capacitance geometrically to the resistive coil with proper dimension. As a result a very low phase angle can be achieved within the realizable dimensions.

  • PDF

A watt-converter for a wideband frequency power measurement (광대역 주파수를 가진 전력 측정 변환기)

  • Park, Young-Tae;Jung, Jae-Kap;Gang, Jeon-Hong;Ryu, Kwon-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2332-2334
    • /
    • 2004
  • A high bandwidth watt-converter, based on an inexpensive, commercially available, standard IC package, is described that covers a frequency ranges from DC to 100 kHz. The new resistive shunt for a wide-band frequency current measurement of the watt-converter was developed. The converter will use application in accurate power measurement under distorted and high frequency conditions. The advantages of the watt-converter are its simplicity, low cost and fast response time.

  • PDF