• Title/Summary/Keyword: Resistance Ultrafiltration

Search Result 57, Processing Time 0.02 seconds

Permeation Characteristics of Wastewater Containing Si Fine Particles through Ultrafiltration

  • Park, Ho-Sang;Park, Young-Tae;Lee, Seok-Ki
    • Korean Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.31-35
    • /
    • 2003
  • The permeation characteristics of the wastewater containing Si fine particles were examined by ultrafiltration using the polyolefin tubular membrane module. Flux with time was due to the growth of Si cake deposited on the membrane surface and the pore plugging by fine particles. The rate of flux decline in the initial stage increased with the trans-membrane pressure. The pore blocking resistance was the dominant resistance at the initial period of filtration and the cake resistance began to dominate with the initial pore blocking resistance. The larger pores compared with the fine particles, the more the membrane pores could be blocked by the fine particles. Before and after treatment, the distribution of particle size was shifted toward to the left. Then, the average size of fine particles in the permeate was 20 nm.

Effects of ring number and baffled-ring distances on ultrafiltration in the tubular membrane inserted concentrically with a ring rod

  • Yeh, Ho-Ming;Ho, Chii-Dong;Li, Cha-Hsin
    • Membrane and Water Treatment
    • /
    • v.3 no.1
    • /
    • pp.51-62
    • /
    • 2012
  • The permeate flux declination along an ultrafilter membrane is due mainly to the concentration-polarization resistance increment and the decline in transmembrane pressure. It was found in previous works that the concentration polarization resistance could be reduced in a ring-rod tubular membrane ultrafilter using the turbulent behavior. In the present study, the performance was further improved by properly and gradually decreasing the baffled-ring distance along the cross-flow channel coupled with properly adjusting the number of baffled rings. This theoretical analysis is based on the mass and momentum balances as well as the application of the resistance-in-series model. The correlation predictions are confirmed with the experimental results for dextran T500 aqueous solution ultrafiltration.

A Study on the Determination of Backwash Condition and Fouling in Coagulation/Ultrafiltration Membrane System (응집·한외여과 공정에서 역세척 조건 결정 및 막오염 특성에 관한 연구)

  • Moon, Seong-Yong;Lee, Sang-Hyup;Lee, Byoung-Cheun;Yun, Jong-Sub;Kim, Seung-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.17-22
    • /
    • 2006
  • This study is about backwash condition and membrane fouling at continuous coagulation/ultrafiltration process in water treatment. The capacity of pilot plant was $0.06m^3/d$. The result of the test, Backwash cycle time and duration time had a significant effect on the efficiency of system and backwash. Backwash duration time was determined to be fixed in 30 seconds for the system with more than 95% recovery rate, It needed 30 minute backwash frequency. During the continuous operation, membrane fouling was analyzed by determining the filtration resistance ($R_i$) and cake layer resistance ($R_c$). At the initial stage, filtration resistance highly influenced the fouling behavior. But after 1.5 hours, cake layer resistance became more important than filtration resistant.

The Major Developments of the Evolving Reverse Osmosis Membranes and Ultrafiltration Membranes

  • Kurihara, Masaru
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.10a
    • /
    • pp.9-16
    • /
    • 1991
  • The current status of reverse osmosis and ultrafiltration membranes are reviewed with the view for the future. In the case of reverse osmosis (RO) membranes, as examples, new crosslinked aromatic polyamide membranes exhibited the superior separation performance with the sufficient water permeability, the high tolerance for oxidizing agents and chemicals. Ultrafiltration (UF) membrane based on poly(phenylene sulfide sulfone) (PPSS) also exibited the superior separation performance with the high solvent, heat and fouling resistance.

  • PDF

Permeation of Ultrafiltration Membranes of Anion Charged poly(bis[4-(3-aminophenoxy) phenyl]sulfone/trimellite amide) Containing Carboxylic Acid (Carboxylic acid 함유한 음이온성 Poly(bis[4-(3-aminophenoxy)phenyl]sulfone/trimellite amide) 한외여과막의 투과특성)

  • Jeon, Jong-Young
    • Membrane Journal
    • /
    • v.19 no.2
    • /
    • pp.104-112
    • /
    • 2009
  • Ultrafiltration membranes (UF) were manufactured by the conventional phase inversion method using an additives with N-methyl-2-pyrrolidinone as a solvent. Characteristics of performance could be controlled by the preparation conditions and the operating methods. The fouling resistance was observed by the relative ratio of permeate flux $(J_t)$/pure water flux $(J_o)$. Compared with the anion charged membranes and its original polyamide membrane, fouling resistance to the protein was increasing in proportion to the ion exchange capacity. The relative flux for the bovin serum albumin (BSA) solution increased as pH value further away from isoelectric point of BSA. The hydrophilicity of a membrane, the pH condition, and the operating temperature played the important role in the membrane permeations.

Separation and flux characteristics in cross-flow ultrafiltration of bovine serum albumin and bovine hemoglobin solutions

  • Hsiao, Ruey-Chang;Hung, Chia-Lin;Lin, Su-Hsia;Juang, Ruey-Shin
    • Membrane and Water Treatment
    • /
    • v.2 no.2
    • /
    • pp.91-103
    • /
    • 2011
  • The flux behavior in the separation of equimolar bovine serum albumin (BSA) and bovine hemoglobin (HB) in aqueous solutions by cross-flow ultrafiltration (UF) was investigated, in which polyacylonitrile membrane with a molecular weight cut-off (MWCO) of 100 kDa was used. BSA and HB have comparable molar mass (67,000 vs. 68,000) but different isoelectric points (4.7 vs. 7.1). The effects of process variables including solution pH (6.5, 7.1, and 7.5), total protein concentration (1.48 and 7.40 ${\mu}M$), transmembrane pressure (69, 207, and 345 kPa), and solution ionic strength (with or without 0.01 M NaCl) on the separation were examined. It was shown that the ionic strength had a negligible effect on separation performance under the conditions studied. Although BSA and HB are not rigid bodies, the flux decline in the present cross-flow UF did not result from the mechanism of cake filtration with compression. In this regard, the specific cake resistance when pseudo steady-state was reached was evaluated and discussed.

A Study of Fouling in Egg-white Concentration by Ultrafiltration with Tubular Module

  • Chio, Nam-Seok;Kim, In--Chul;Tae- Hyun Bae;Kim, Jong--Ho;Tae- Moon Tak
    • Korean Membrane Journal
    • /
    • v.3 no.1
    • /
    • pp.17-23
    • /
    • 2001
  • Polyethersulfone (PES) and cellulose acetate (CA) ultrafiltration (UF) membranes having different molecular weight cut-off values were prepared by immersion precipitation method by changing the compositions of easting solution. Egg white solution was concentrated to volume concentration ratio 4 in tubular UF with membranes made of moderately hydrophobic PES and hydrophilic CA. The process Parameters such as pressure and fluid velocity were controlled in order to apply successfully for egg white solution and to investigate the pressure dependency. The resistance values were measured to investigate the fouling and concentration polarization effect on membrane performance. During concen- tration of egg white solution by UF, the fouling layer appeared to contribute little resistance to flux compared to that of polarized layer.

  • PDF

The Effect of Gel Layer Formation on Fouling Characteristics in Ultrafiltration of Peach Juice (복숭아 주스의 한외여과시 겔층형성에 따른 막오염 특성)

  • 고은정;이주백;이준호;최용희
    • Food Science and Preservation
    • /
    • v.6 no.4
    • /
    • pp.424-428
    • /
    • 1999
  • The performance of a 30K polysulfone membrane for clarification of depectinized peach juice was studied Ultrafiltration of peach juice could minimize to loss of flavor and many compounds and was expected to effectively remove precipitation and suspended solid. The results showed that permeate flux increased with the increase of operating pressure and temperature. The permeate flux declined continuously as the process time increased. The values of soluble solid and titratable acidity of permeate were decreased or were at the same level, the turbidity was largely decreased. Total resistance decreased with lower temperature and lower pressure.

  • PDF

Effect of coagulation conditions on ultrafiltration for wastewater effluent

  • Maeng, Sung Kyu;Timmes, Thomas C.;Kim, Hyun-Chul
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.185-199
    • /
    • 2017
  • Low-pressure membrane filtration is increasingly used for tertiary treatment of wastewater effluent organic matter (EfOM), mainly comprising organic base/neutral compounds. In-line coagulation with underdosing, charge neutralization, and sweep floc conditions prior to ultrafiltration (UF) was studied to determine removals of the EfOM components and consequent reduction of fouling using polyethersulfone membranes. Coagulation and UF substantially reduced fouling for all coagulation conditions while removing from 7 to 38% of EfOM organic acids. From 7 to 16% of EfOM organic base/neutrals were removed at neutral pH but there was no significant removal for slightly acid coagulation conditions even though fouling was substantially reduced. Sweep floc produced the lowest resistance to filtration but may be inappropriate for in-line use due to the large added volume of solids. Charge-neutralization resulted in poor recovery of the initial flux with hydraulic cleaning. Under-dosing paralleled sweep floc in reducing hydraulic resistance to filtration (for sub-critical flux) and the initial flux was also easily recovered with hydraulic cleaning. Hydrophobic and hydrophilic base/neutrals were identified on the fouled membranes but as previously reported the extent of fouling was not correlated with accumulation of organic base/neutrals.

Fouling and cleaning of a tubular ultrafiltration ceramic membrane

  • Siddiqui, Farrukh Arsalan;Field, Robert W.
    • Membrane and Water Treatment
    • /
    • v.7 no.5
    • /
    • pp.433-449
    • /
    • 2016
  • The successful application of cleaning protocols is vital for optimized filtration processes. A series of experiments with an ultrafiltration ceramic tubular membrane were carried out for the foulants dextran and carboxymethyl cellulose. Firstly, the impact on fouling of concentration changes was investigated with the increase in resistance being used as the key parameter. In the second phase, removal of reversible fouling was also investigated by employing intermittent rinsing consisting of a cold water rinse followed by a hot one. A comparative analysis for both foulants is reported. Across a range of concentrations and for both foulants, the reduction in resistance due to rinsing was found to depend upon concentration (C); it changed as $C^n$ where n was found to be 0.3. A plausible semi-theoretical explanation is given. Thirdly, for both foulants, the application of a combination of strong alkaline solutions with oxidizing agent (mainly sodium hypochlorite) followed by acid was found to be appropriate for cleaning of the ceramic membrane. The effect of increased temperature for cleaning agents followed by a warm water rinse contributed positively to the cleaning capability.