• Title/Summary/Keyword: Resin thickness

Search Result 580, Processing Time 0.027 seconds

COLOR CHANGES OF PALFIQUE ESTELITE BETWEEN PRE AND POST IRRADIATIONS (Palfique Estelite의 경화전후 색조 변화에 관하여)

  • Aoshima, Yutaka;Takagi, Haruhito;Sairenji, Noriko;Ikeda, Harughiko;Kuroda, Takashi;Onose, Hideo
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.6 no.1
    • /
    • pp.10-17
    • /
    • 1997
  • It is pointed out that the color of composite resin is changing according to it's ploymerization and this color change is a harmful effect for the clinical satisfacion of composite resin restoration. The purpose of this study was to compare the changes of color of newly developed composite resins between before and after exposure of activating light. Five Compostie resins (8 shades) were employed: Palfique Estelite(UL, U, DY, G ; Tokuyama), Photo Clearfil A (US : Kuraray), Photo Clearfil Bright (US ; Kuraray), GC Graft LC(A3 ; GC), Silux Plus(U; 3M), Tristirnulus values of each material were determined before and after curing-light exposure by using a Micro Multi Photometer (MMP-1001, Nihon Denshoku Kogyo). The values were transformed into $L^*\;a^*\;b^*$ system and color changes of the resins were evaluated by the changes of $L^*$, $a^*$ and $b^*$ values for the individual shades. In addition, the effects of resin thickness and background color on color changes were also studied The finding were as follows: 1. Color changes of $L^*$, $a^*$ and $b^*$ values were recognized due to the light exposure for all products. The $b^*$ values of Palfique Estelite showed negligible changes for all shades. 2. The $b^*$ values were affected strongly by the background color, especially when decreasing the brightness on the background color.(Request original article reprints to Dr. Aoshima)

  • PDF

A STUDY ON THE FITNESS OF THE IPS EMPRESS CERAMIC CROWN ACCORDING TO MARGIN TYPE (변연형태에 따른 IPS Empress 도재관의 적합도에 관한 연구)

  • Ju, Tae-Hun;Oh, Sang-Chun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.846-857
    • /
    • 1998
  • The purpose of this study was to compare the fitness of the IPS Empress ceramic crowns according to margin type such as bevel, shoulder, rounded shoulder, shoulder with bevel, rounded shoulder with bevel and grooved bevel. After 10 experimental dies were constructed for each group, the IPS Empress ceramic crowns were fabricated on the dies, cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. Ltd., Japan) and embeded in clear epoxy resin. Each specimen was sectioned with a low speed diamond saw in both the faciopalatal and the mesiodistal direction. The cement film thickness was measured with a measuring microscope. The obtained results were as follows : 1. The fitness at the external margin was good in the following order: rounded shoulder(28.99), shoulder with bevel(31.33), grooved bevel(31.79), rounded shoulder with bevel(34.65), bevel(35.02) and shoulder(35.08). However there is no significant statistical difference. 2. The fitness at the internal margin of bevel(25.75), rounded shoulder(31.24), shoulder with bevel(32.07) and rounded shoulder with bevel(34.45) was better than that of shoulder(47.98). 3. The fitness at the axial surface of bevel(26.58) was better than that of shoulder(49.59). 4. The fitness at the central fossa was good in the following order: shoulder with bevel(38.88), grooved bevel(40.46) rounded shoulder with shoulder(46.29), shoulder(48.91), bevel(49.47) and rounded bevel(52.07). However there is no significant statistical difference. 5. Overall fitness of bevel(29.71), rounded shoulder(32.49) and shoulder with bevel(34.47) was better than that of shoulder(44.73).

  • PDF

MARGINAL DISCREPANCY AND RETENTION FORCE OF CONICAL TELESCOPE OUTER CROWN WITH CO-CR-TI ALLOY (Co-Cr-Ti 합금으로 제작한 conical telescope 외관의 변연적합도와 유지력에 관한 연구)

  • Jung, Hi-Chan;Jeong, Chang-Mo;Jeon, Young-Chan;Lim, Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.214-225
    • /
    • 2000
  • The purpose of this study was to investigate the effects of investing conditions on the marginal discrepancy of conical telescope outer crown with Co-Cr-Ti alloy(Dentitan) and to compare the marginal discrepancy and the retention force of outer crowns using different pattern materials(plastic foil, casting wax, pattern resin). To evaluate the effects of investing conditions on the marginal discrepancy, patterns with plastic foil were invested under three different liquid/powder ratio conditions using phosphate bonded investment(Univest-nonprecious): standard, 10% decreased and 10% increased. At each liquid/powder ratio condition, metal ring was lined with single or double layers of ceramic ring liner. The marginal discrepancy of outer crown at different investing conditions was measured by ${\times}100$ compact measuring microscope(STM5, Olympus, Japan). For measurement of the marginal discrepancy and the retention force of outer crown using different pattern materials, the investing condition of 10% decreased liquid/powder ratio and double layers of ring liner was selected because this investing condition resulted in the best fit of outer crown. Marginal discrepancy was measured in the same way above and retention force on universal testing machine. Under the conditions of this study, the following conclusions were drawn: 1. The thickness of ring liner had more influence on the marginal discrepancy of outer crown than the liquid/powder ratio, and the acceptable marginal fitness could not be expected at the investing condition directed by investment manufacturer 2. There were no differences in the marginal discrepancy of outer crown among three different pattern materials(P>0.05). 3. Casting wax showed the greatest retention force(1640g) of outer crown, followed by pattern resin(1110g), plastic foil(820g). However, there was no significant difference between plastic foil and pattern resin(P>0.05). 4. Plastic foil showed the least variation in marginal discrepancy and retention force.

  • PDF

EFFECTS OF AGING AND THERMAL CYCLING ON THE BIAXIAL FLEXURE STRENGTH OF VENEERING RESIN COMPOSITES FOR CROWN (시효처리와 thermal cycling이 치관전장용 복합레진의 2축굽힘강도에 미치는 영향)

  • Jeong, Gwan-Ho;Ha, Il-Soo;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.597-606
    • /
    • 1999
  • This study was performed to evaluate the effect of aging and thermal cycling on the biaxial flexure strength of low commercially available veneering resin composites for crown(Dentacolor : DC, Artglass : AG, Esternia : ET and Targis : TG). Disc specimens were fabricated in a teflon mold giving 12mm in diameter and 1mm in thickness. All samples were divided into 4 groups. Group 1 was dried in a dessicator at $25^{\circ}C$ for 30 days. Group 2 was immersed in distilled water at $37^{\circ}C$ for 30 days. Group 3 was immersed in distilled water at $65^{\circ}C$ for 30 days. Group 4 was subjected to 10,000 thermal cycles between $5^{\circ}C\;and\;55^{\circ}C$, and the immersion time in each bath was 15 seconds per cycle. Biaxial flexure test was conducted using the ball-on-three-ball method at the cross head speed of 0.5mm/min and fracture surfaces were observed with scanning electoron microscope. The results obtained were summarized as follows; 1. Weibull modulus values, except for the AG group, decreased after thermal cycling treatment. 2. Biaxial flexure strength values of aging group at $37^{\circ}C$ were the lowest in all sample groups. Except for the DC group, strength values were significantly decreased for the drying group. 3. After thermal cycling test, the highest value of biaxial flexure strength of 188.8 MPa was observed in the ET group and the lowest value of 73.2 MPa was observed in the DC group. The strength values showed the significant differences in each group (p<0.05). 4. Observation of surfaces after thermal cycling test revealed the ditching in the part of surrounding large fillers.

  • PDF

Microshear bond strength according to dentin cleansing methods before recementation

  • Tasar, Simge;Ulusoy, Mutahhar Muhammed;Meric, Gokce
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.79-87
    • /
    • 2014
  • PURPOSE. The aim of this study was to determine the efficiency of Erbium, Chromium: Yttrium-Scandium-Gallium-Garnet laser in different output powers for removing permanent resin cement residues and therefore its influence on microshear bond strength compared to other cleaning methods. MATERIALS AND METHODS. 90 extracted human molars were sectioned in 1 mm thickness. Resin cement was applied to surface of sliced teeth. After the removal of initial cement, 6 test groups were prepared by various dentin surface treatment methods as follows: no treatment (Group 1), ethylene diamine tetra acetic acid application (Group 2), Endosolv R application (Group 3), 1.25 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 4), 2 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 5) and 3.5 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 6). The topography and morphology of the treated dentin surfaces were investigated by scanning electron microscopy (n=2 for each group). Following the repetitive cementation, microshear bond strength between dentin and cement (n=26 in per group) were measured with universal testing machine and the data were analyzed by Kruskal Wallis H Test with Bonferroni correction (P<.05). Fracture patterns were investigated by light microscope. RESULTS. Mean microshear bond strength ${\pm}$ SD (MPa) for each group was $34.9{\pm}17.7$, $32.1{\pm}15.8$, $37.8{\pm}19.3$, $31.3{\pm}12.7$, $44.4{\pm}13.6$, $40.2{\pm}13.2$ respectively. Group 5 showed significantly difference from Group 1, Group 2 and Group 4. Also, Group 6 was found statistically different from Group 4. CONCLUSION. 2 W and 3.5 W Erbium, Chromium: Yttrium-Scandium-Gallium-Garnet laser application were found efficient in removing resin residues.

Comparison of Longitudinal Liquid Permeability of Pinus koraiensis Sapwood Treated by Steaming and Various Drying Methods (증기 및 여러 가지 건조방법으로 처리된 잣나무 변재의 섬유방향 액체투과율 비교)

  • Kang, Ho-Yang;Lu, Jianxiong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.6 s.134
    • /
    • pp.17-24
    • /
    • 2005
  • Korean pine (Pinus koraiensis Sieb.et Zucc.) boards of 30 mm thickness were treated by steaming and four different drying methods. Small specimens were taken from the sapwoods of the treated boards and their longitudinal liquid permeability was measured according to Darcy's law. The specimens were also extracted with alcohol and aceton solutions to examine the mechanism of liquid flow in wood. It was observed that specific permeability drastically decreases with measurement time, resulting in violation of Darcy's law. It may be due to that air bubbles formed under vacuum block flow paths in resin canals. The average specific permeabilities of non-extracted and extracted specimens are different from one treatment to another. It is supposed that the properties of residual resin in resin canals change depending on the conditions of treatments. Anatomical examination was conducted with a scanning electron microscope.

How does duration of curing affect the radiopacity of dental materials?

  • Bejeh Mir, Arash Poorsattar;Bejeh Mir, Morvarid Poorsattar
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.89-93
    • /
    • 2012
  • Purpose : Clinicians commonly encounter cases in which it is difficult to determine whether adjacent radiopacities are normal or pathologic. The ideal radiopacity of composite resin is equal to or higher than that of the same thickness of aluminum. We aimed to investigate the possible effects of different curing times on the post-24-hour radiopacity of composite resins on digital radiographs. Materials and Methods : One mm thick samples of Filtek P60 and Clearfil resin composites were prepared and cured with three regimens of continuous 400 mW/$cm^2$ irradiance for 10, 20 and 30 seconds. Along with a 12-step aluminum step wedge, digital radiographs were captured and the radiopacities were transformed to the equivalent aluminum thicknesses. Data were compared by a general linear model and repeated-measures of ANOVA. Results : Overall, the calculated equivalent aluminum thicknesses of composite resins were increased significantly by doubling and tripling the curing times (F(2,8)=8.94, p=0.002). Notably, Bonferroni post-hoc tests confirmed that the radiopacity of the cured Filtek P60 was significantly higher at 30 seconds compared with 10 seconds (p=0.04). Although the higher radiopacity was observed by increasing the time, other comparisons showed no statistical significance (p>0.05). Conclusion : These results supported the hypothesis that the radiopacity of resin composites might be related to the duration of light curing. In addition to the current standards for radiopacity of digital images, defining a standard protocol for curing of dental materials should be considered, and it is suggested that they should be added to the current requirements for dental material.

Flexural strength of composite resin fabricated by various polymerization method (다양한 중합 방법으로 제작한 간접 수복물용 복합레진의 굴곡 강도)

  • Kim, Dong-Yeon;Park, Jin-Young;Kang, Hoo-Won;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.40 no.2
    • /
    • pp.57-62
    • /
    • 2018
  • Purpose: The aim of this study is to evaluate composite resins of indirect restorations for testing of flexural strength according to various polymerization methods. Methods: Specimen was produced a total of 40 to 10 per each group with a length 25 mm, width 2 mm, thickness 2 mm using a Teflon zig. The polymerization groups were classified into four groups. The first group proceeded with light curing only(LC group). The second group proceeded with light and heat curing(LHC group). The third group proceeded with air press and light curing(ALC group). The fourth group proceeded with air press, light and heat curing(ALHC group). Each prepared group was evaluated by flexural strength test. Statistical analysis was performed by one-way ANOVA. Post-test was performed with Tukey test. Results: The lowest in the ALC group was 119.18 MPa and the highest in the ALHC group was 168.15 MPa. There were statistically significant differences. Conclusion : The composite resin of the indirect restoration is recommended to heat curing along with the air press.

TEMPERATURE TRANSMISSION OF PAC UNIT THROUGH DENTIN (상아질을 통한 플라즈마 아크 광중합기의 온도 전달)

  • Park, Ho-Won;Kim, Ji-Hun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.707-714
    • /
    • 2003
  • Plasma Arc Curing(PAC) units operate at relatively high intensity and claimed to result in optimum properties of composite resin in a short curing time, so the interest of pediatric dentists about PAC units have been increased recently. But PAC units used for polymerizing restorative resins produce heat during operation. The purpose of this study was to evaluate temperature transmission through dentin of various depths using two types of PAC units(Flipo, Q-Lux plasma 100). The results from the present study can be summarized as follows : 1. When PAC be used continuously, temperature on tip was increased as curing times, and Q-Lux showed greater temperature rising(p<0.001). 2. Compared temperature transmission as dentin depth, temperature rising rate was decreased as dentin thickened(0.5, 1.0, 1.5, 2.0mm)(p<0.05). 3. Compared temperature transmission as resin depth, temperature rising rate was also decreased as resin thickened(1.0, 2.0mm)(p<0.05).

  • PDF

Tribological Characteristics of ABS-like Resin According to Silicon Oil Viscosity (실리콘 오일 점도에 따른 ABS-like 레진의 트라이볼로지 특성)

  • Park, Seonghyun;Son, Jungyu;Woo, Seongwoong;Ryu, Euijin;Lee, Hyunseop
    • Tribology and Lubricants
    • /
    • v.36 no.6
    • /
    • pp.365-370
    • /
    • 2020
  • Recently, additive manufacturing (AM) technology has been applied to various industries such as automotive, aviation, medical, and electronics. Most prior studies are limited to the mechanical properties of printed materials, and few studies are being conducted on their tribological characteristics. However, the friction and wear characteristics of the material should be studied in order to utilize the components manufactured using AM technology as mechanical parts. In this study, the friction and wear characteristics of acrylonitrile-butadiene-styrene (ABS)-like resin printed with stereo lithography apparatus (SLA) 3D printing are evaluated according to the viscosity of silicon oil lubricant using a ball-on-disk experiment. Lubricants with a viscosity of 500, 1000, and 2000 cSt are prepared for the experiment. If silicon oil lubricants are used during the ball-on-disk test, the coefficient of friction (COF) and wear rates are significantly reduced, and the higher the viscosity of the lubricant, the lower will be the COF and wear rates. It is also verified that the temperature of the specimen owing to friction also decreases according to the viscosity of the lubricant. This is because of the silicon oil film thickness, and the higher the viscosity of the lubricant, the thicker will be the oil film. More studies on the tribological characteristics of 3D printing materials and suitable lubricants will be required to use 3D printed parts as mechanical elements.