• 제목/요약/키워드: Resin series

검색결과 110건 처리시간 0.026초

Sprayed FRP 공법에 의한 콘크리트 구조물의 보수.보강법 개발에 관한 연구 - 철근콘크리트 보의 보강성능 평가 - (Repair and Strengthening Methods for Concrete Structures using Sprayed Fiber Reinforced Polymers - Strengthening Performance of Reinforced Concrete Beams -)

  • 이강석;손영선;변인희;이문성;나정민;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.133-136
    • /
    • 2006
  • The main purpose of this study is to develop a Sprayed FRP repair and strengthening method, which is a new technique for strengthening the existing concrete structures by mixing carbon or glass shot fibers and the epoxy or vinyl ester resins with high-speed compressed air in open air and randomly spraying the mixture onto the concrete surface. At present, the Sprayed FRP repair and strengthening method using the epoxy resin has not been fully discussed. In this study, a series of experiments are carried out to evaluate the strengthening effects of the flexural and shear concret beams strengthened with the Sprayed FRP method. The results revealed that the strengthening effects of the flexural and shear specimens are similar, compared to those of the FRP sheet.

  • PDF

폴리머계로 보수한 철근콘크리트 보의 휨성능 평가 (An Evaluation on the Flexural Strength of Concrete Beams Repaired by Polymer Resin)

  • 김병국;신영수;홍기섭;홍영균;최완철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제1권1호
    • /
    • pp.107-112
    • /
    • 1997
  • A series of reinforced concrete beams was tested to evaluate the flexural performance of the repaired RC beams. The key parameters for this study were the size and location of the patch, and the repair materials, including polymer, polymer-cementitious and cementitious materials. The repaired specimens failed by a typical flexural mode with minor interfacial bond failure. Beams repaired with polymer, polymer-cementitious and cementitious materials recover 100%, 91%, and 97% of the flexural strength respectively, while beams with cement mortar lose approximately 30% of the strength. Compared with the pressure injection techniques the specimens repaired with patching techniques show low flexural strength, with significant interfacial bond failure. Location and size of the repaired part do not affect the recovering performance. Interfacial behavior between repair and strengthening materials is the major influencing factor for the composite structures.

  • PDF

적산온도법에 의한 에폭시 모르터의 초기강도 예측 (The Early Strength Prediction of Epoxy Mortars by the Maturity Method)

  • 연규석
    • 한국농공학회지
    • /
    • 제42권2호
    • /
    • pp.99-107
    • /
    • 2000
  • The objective of this study are to compare the development of compressive strength of epoxy mortars used as repairing materials with respect to maturity , and to propose a model predicting strength development of epoxy mortars. A series of tests are carried out for the hardener contents of 30, 40 and 50 percentage of epoxy resin and compressive strengths are measured at the age of 6, 12, 24, 72, 120 and 168 hours respectively under the cure temperature of 0, 10, 20 and 3$0^{\circ}C$. The datum temperature is estimated by measured strengths, and the maturity is calculated with the estimated datum temperature. The compressive strength of epoxy mortars can be predicted by regression analysis from the maturity-compressive strength relationship.

  • PDF

임피던스 공진기를 이용한 FR-4 임베디드 광대역필터 (FR-4 Embedded UWB Filter using Uniform Impedance Resonator)

  • 양창수;윤상근;박재영
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1471-1475
    • /
    • 2007
  • In this paper, a novel embedded ultra wideband (UWB) band-pass filter is presented on a FR-4 package substrate including high Dk resin coated copper (${\varepsilon}_r=30$) film. The proposed UWB filter is comprised of a parallel resonator with meander-type uniform impedance resonator (UIR) and two series resonators with high Q circular stacked spiral inductor and metal-insulator-metal (MIM) capacitor. In order to obtain excellent attenuation characteristics by generating attenuation poles in lower and upper stop bands, a single MIM capacitor is added to each resonator. The fabricated FR-4 embedded UWB filter has insertion loss of -1.0dB and return loss of -11dB, respectively. It has also extremely wide bandwidth (over 50%) and small size ($3.7{\times}4{\times}0.77\;mm^3$) which is compatible with LTCC devices.

VOC Free Epoxy Resin/Dicyandiamide 경화물의 배합비 변화에 따른 물리적 특성 및 열적특성 분석 (The Physical and Thermal Properties Analysis of the VOC Free Composites Comprised of Epoxy Resin, and Dicyandiamide)

  • 김대연;김순천;박영일;김영철;임충선
    • 청정기술
    • /
    • 제21권1호
    • /
    • pp.76-82
    • /
    • 2015
  • 휘발성 유기 화합물(volatile organic compounds, VOC)이 없는 접착제가 환경 보호 및 산업체 종사자의 건강을 보호하기위해 산업계에서 많은 관심을 받고 있으며, 본 논문에서는 에폭시 수지를 용매처럼 사용하여 유기용매를 사용하지 않아 유해 물질을 발생시키지 않으면서 상온에서 보관성이 좋은 잠재성 접착소재의 조성물 배합비에 관한 연구를 수행하였다. 바인더 재료인 에폭시 수지에 다양한 경화제 함량을 사용하여 기계적 강도, 열적 특성, 충격 특성 및 전단강도 실험을 진행하여 에폭시 수지 대비 경화제의 최적 조성비를 파악하는 실험을 실시하였다. 에폭시 경화물 시험편의 탄성계수, 인장강도, 신율 등의 기계적 강도는 만능시험기(universal testing machine, UTM)로 측정하였고, 각 조성물의 충격저항성 및 접착 강도 또한 충격시험기(izod impact tester)와 UTM으로 측정하였다. 인장강도, 탄성계수, 신율 및 충격 강도에서는 화학양론비에 근접한 에폭시 수지 대비 0.9당량의 경화제 함량 조성물에서 다른 함량 조건에 비해 우수한 결과를 보여주었으며, 동역학분석기(dynamic mechanical analysis, DMA)를 통한 열적 특성 조사에서는 0.7 당량의 경화제 함량 조성물에서 가장 높은 tanδ 값이 관찰되었다. 주사전자현미경을 이용한 에폭시-경화제 경화물의 파단면 모폴로지 관찰에서는 경화제 함량증가에 따라 파단면에서 crack에 의한 물결모양의 미세한 선들이 증가함을 보여주었다. 경화물의 시험시편 실험 결과를 통해서 0.9 당량의 경화제 함량 경화물이 기계적 강도가 우수하고 0.7 당량 조성물의 경화 시험편이 열적 및 접착 강도 측면에서 뛰어남을 알 수 있었다. 또한 잠재성 경화제를 사용한 조성물의 점도 변화를 측정하여 상온에서의 저장 안정성이 뛰어남을 확인하였다.

Osteoplasty in Acute Vertebral Burst Fractures

  • Park, Sang-Kyu;Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권2호
    • /
    • pp.90-94
    • /
    • 2006
  • Objective : Acute vertebral burst fractures warrant extensive fixation and fusion on the spine. Osteoplasty [vertebroplasty with high density resin without vertebral expansion] has been used to treat osteoporotic vertebral compression fractures. We report our experiences with osteoplasty in acute vertebral burst fractures. Methods : Twenty-eight cases of acute vertebral burst fracture were operated with osteoplasty. Eighteen patients had osteoporosis concurrently. Preoperative MRI was performed in all cases to find fracture level and to evaluate the severity of injury. Preoperative CT revealed burst fracture in the series. The patients with severe ligament injury or spinal canal compromise were excluded from indication. Osteoplasty was performed under local anesthesia and high density polymethylmethacrylate[PMMA] was injected carefully avoiding cement leakage into spinal canal. The procedure was performed unilaterally in 21 cases and bilaterally in 7 cases. The patients were allowed to ambulate right after surgery. Most patients discharged within 5 days and followed up at least 6 months. Results : There were 12 men and 16 women with average age of 45.3[28-82]. Five patients had 2 level fractures and 2 patients had 3 level fractures. The average injection volume was 5.6cc per level Average VAS [Visual Analogue Scale] improved 26mm after surgery. The immediate postoperative X-ray showed 2 cases of filler spillage into spinal canal and 4 cases of leakage into the retroperitoneal space. One patient with intraspinal leakage was underwent the laminectomy to remove the resin. Conclusion : Osteoplasty is a safe and new treatment option in the burst fractures. Osteoplasty with minimally invasive technique reduced the hospital stay and recovery time in vertebral fracture patients.

만곡근관에서 수동식 기구와 엔진 구동형 기구의 근관성형 효과에 대한 비교 연구 (The EFFECTS OF VARIOUS INSTRUMENTATION TECHNIQUES IN CURVED CANALS OF RESIN BLOCKS)

  • 정일영;윤태철;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.648-658
    • /
    • 1997
  • The purpose of this study was to compare the effects of various techniques on the quality and quantity of instrumentation in curved canals. Instrumentation time was evaluated too. Forty eight canals of resin blocks($35^{\circ}$) were divided into three groups and filed. In group A, 16 blocks were instrumented using a step-back technique with stainless steel(SS) K-file(Mani, Matsutani Seisakusho Co.,Japan). In group B, canals were prepared with SS K-files using the Endo-Angle (Nakanishi Dental MFG.CO.,LTD.,Japan). Group C was prepared using N i-Ti engine-driven instruments (Quantec Series $2000^{TM}$ system). Group A and B were filed from # 5 to # 25 at the apex followed by a 1 mm stepback technique, and the coronal half of the canals were flared with Gates Glidden burs(#2,3,4). Group C was instrumented from # 1 to # 8. After the instrumentation time was measured, canals were filled with India ink, and photographed, which to magnify the canal images 8 times. Using these photographs the apical portions were evaluated And scored from 1 to 4 according to the severity of ledging and zipping. On the same photographs, the area of the coronal two thirds of the canals were measured using a personal computer with the computer program Brain and Digitizer (SummaSketch III). The following results were obtained. 1. Instrumentation time was significantly shorter for group C, as opposed to group A and B(ANOVA, P<0.05). 2. The qualitative evaluation of the apical portions of the canals showed no significant difference between the groups(Kruscal-Wallis, p>0.05). 3. The area removed by group C was significantly smaller than group A and B(ANOVA, P<0.05).

  • PDF

다수 캐비티 사출금형에서의 균형 충전을 위한 러너 시스템 연구 (A study on the runner system for filling balance in multi-cavity injection molds)

  • 전강일;노승규;김동학
    • 한국산학기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.1581-1588
    • /
    • 2011
  • 사출성형은 열가소성 수지의 가공법으로 정밀도나 고품질의 제품을 효과적으로 생산하는데 널리 이용되는 기술이다. 다수 캐비티 사출성형에서 캐비티 충전 불균형이 발생하는데 이러한 현상은 사출성형품의 치수 및 중량의 편차 뿐 아니라 물리적 특성에 영향을 미치고 있다. 충전 불균형은 충전 단계에서 러너 내에서 발생되는 불균일한 전단분포에 기인하여 발생되므로 점도 변화에 영향을 주는 수지의 물성, 사출조건 등 성형공정 조건 요인에 의해 충전 불균형의 양상이 다르게 된다. 본 논문에서는 점도 및 물성이 다른 PC, PP 수지에 대하여 성형조건에 따른 충전 현상을 관찰하고 원인을 분석하였고 사출속도에 따른 충전 불균형 현상의 원인을 고찰하기 위해 사출성형실험과 CAE 해석을 수행하였다. CAE 해석을 수행하여 각 수지마다 사출속도에 따른 충전 패턴 경향과 온도분포를 예측하고 캐비티 간 충전 균형을 위해 새로운 볼륨 러너 시스템을 제시하였고 캐비티 간 충전 균형을 확인 할 수 있었다.

보물 제1925호 금강산 출토 이성계 발원 사리장 엄구 내 유리제 사리병의 복원 및 안정성 연구 (Restoration and Stability of the Glass Sarira Bottle (Treasure No. 1925) from the Sarira Reliquaries Commissioned by Yi Seonggye, Excavated from Geumgangsan Mountain)

  • 나아영;황현성
    • 박물관보존과학
    • /
    • 제26권
    • /
    • pp.25-34
    • /
    • 2021
  • 문화재 복원 분야에서 3D 기술이 복원에 적용되고 있다. 그러나 아직까지 유리제 문화재의 복원에 관하여 3D 기술이 활용되어 복원된 사례가 적으며 이에 관한 연구가 필요한 상황이다. 이에 본 연구에서는 국립중앙박물관에서 소장하고 있는 보물인 금강산 출토 이성계 발원 사리장엄구 일괄 중 유리제 사리병의 결손부를 복원하는 과정에 3D 기술을 이용하였다. 보존처리는 3D 프린팅 출력물을 직접적으로 복원제로써 적용하지않고 에폭시계수지로 복제한 복원편으로 결손부를 복원하였다. 보존처리 완료 후 3D 프린팅에 사용되는 재료와 기술방식에 관하여 기존 도자기의 복원재료 중 투명성을 지닌 재료를 선택하여 사용감과 안정성을 비교하고자 하였다. 보존처리 완료 후 SLA(Stereo Lithography Apparatus)방식으로 출력한 광경화성 수지, 에폭시계 수지, 아크릴계 수지등 총 5개의 시편을 제작 한 후 96시간까지 자외선에 노출시켜 황변화를 조사하였고, 광경화성수지의 시편은 출력물에 UV차단제를 분무 여부에 따라 2종으로 나누어 자외선에 노출시켰다. 자외선 노출 결과, SLA방식 시편에 UV차단제를 분무한 시편, 에폭시계수지의 시편의 b*값의 변화값이 1 미만으로 황변화에 안정적인 것으로 나타났으며 유리제 문화재의 복원제로써 적용 가능한 재료로 보여진다. 유리제 문화재의 형태가 매우 다양하고 복원해야할 부분 또한 다양하고 복잡하여 접근하기 어려울 수 있으므로 복원재료에 대해 여러 가지 재료를 염두해두고 고민해볼 필요가 있다.

광개시제에 따른 실험용 3D 프린팅 의치상 레진의 기계적 성질과 생체적합성 비교 (Comparison between mechanical properties and biocompatibility of experimental 3D printing denture resins according to photoinitiators)

  • 박다령;손주리
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.355-361
    • /
    • 2020
  • Purpose: In this study, we added two kinds of photoinitiators (CQ and TPO) to prepare two kinds of denture base resins (Bis-GMA series and UDMA series) for three-dimensional (3D) printing to compare and analyze their mechanical and biological properties and to find the optimal composition. Methods: Control specimens were made using the mold made of polyvinyl siloxane of the same size. Light curing was performed twice for 20 seconds on both the upper and lower surfaces with LED (light emitting diode) light-curing unit (n=10). Experimental 3D printing dental resins were prepared, to which two photoinitiators were added. Digital light processing type 3D printer (EMBER, Autodesk, CA, USA) was used for 3D printing. The specimen size was 64 mm×10 mm×3.3 mm according to ISO 20795-1. The final specimens were tested for flexural strength and flexural modulus, and MTT test was performed. Furthermore, one-way analysis of variance was performed, and the post-test was analyzed by Duncan's test at α=0.05. Results: The flexural strength of both Bis-GMA+CQ (97.12±6.47 MPa) and UDMA+TPO (97.40±3.75 MPa) was significantly higher (p<0.05) in the experimental group. The flexural modulus in the experimental group of UDMA+TPO (2.56±0.06 GPa) was the highest (p<0.05). MTT test revealed that all the experimental groups showed more than 70% cell activity. Conclusion: The composition of UDMA+TPO showed excellent results in flexural strength, flexural modulus, and biocompatibility.