• 제목/요약/키워드: Resin inlay

검색결과 62건 처리시간 0.022초

복합레진 인레이의 내면처리와 합착용 시멘트의 종류에 따른 인장접합강도에 관한 연구 (A STUDY ON THE TENSILE BOND STRENGTH OF COMPOSITE RESIN INLAYS ACCORDING TO THEIR INTERNAL SURFACE TREATMENT AND TYPES OF LUTING CEMENT)

  • 김진철;조영곤;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.103-113
    • /
    • 1993
  • The purpose of this study was to evaluate the tensile bond strength of composite resin inlays according to the their internal surface treatment and types of luting cement and compared them with the conventional direct resin filling thchnique. Class II cavities were prepared in 50 extracted human molar teeth, and then equally divided into five groups. Group 1 : Cavities of control group were directly filled with P-50. Group 2 : Cavities of resin inlay group were luted with resin cement. Group 3 : Cavities of resin inlay group were luted with luting G-I cement. Group 4 : Cavities of resin inlay group were luted with resin cement after sandblasting. Group 5 : Cavities of resin inlay group were luted with luting G-I cement after sandblasting. All specimens were polished with same method and stored in normal saline for 24 hours before testing. An Universal Testing machine(Model No. AGS-100A, Shimadzu, Japan) was used to apply tensile loads in the vertical direction, and the force required for separation was recorded with a cross-head speed of 5mm/min and 100kg in full scale. The results were as follows : 1. The mean tensile bond strength was lowest in group luted with luting G-I cement, with measurements of $14.45{\pm}0.78(kg/cm^2)$ and highest in group luted with resin cement after sandblasting, with measurements of $49.6{\pm}2.74(kg/cm^2)$. 2. The tensile bond strength was greater in resin inlay groups luted with resin cement than in control group and resin inlay groups luted with luting G-I cement(P<0.05). 3. The tensile bond strength was lower in resin inlay groups luted with luting G-I cement than in control group(P<0.05). 4. The tensile bond strength was greater in resin inlay groups luted with resin cement or luting G-I cement after sandblasting than without that(P<0.05).

  • PDF

반직접법 레진 인레이를 이용한 구치부의 수복 (SEMIDIRECT RESIN INLAY RESTORATION OF POSTERIOR TEETH)

  • 한미란;김종수;김용기
    • 대한소아치과학회지
    • /
    • 제26권3호
    • /
    • pp.479-485
    • /
    • 1999
  • 복합레진을 이용한 수복은 재료의 낮은 강도와 중합수축으로 인한 변연 누출 그리고 상아질과의 결합력 등으로 인해 제한된 범위에서만 사용되었으나, 최근 물성의 향상 및 상아질 결합제의 발달로 심미수복이 필요한 여러 부위에 이용되고 있다. 반직접법을 이용한 레진 인레이는 와동의 크기가 너무 크거나 직접 수복이 곤란한 경우 사용될 수 있으며, 어린 환자의 영구구치 수복시 적절한 비용으로 가급적 오랫동안 보철치료를 받지 않고 사용할 수 있도록 한다. 반직접법의 장점으로는 중합수축으로 인한 변연누출이 적고, 2차 중합을 통해 중합도가 증가하여 강도가 증가되며, 간접법시 필요한 기공실 과정이 불필요하여 1회의 내원으로 치료 가능하다는 것 등이 있다. 본 증례는 심미적 치료를 원하는 환자의 구치부 수복시 반직접법을 이용한 레진 인레이를 사용하여 양호한 치료결과를 얻었기에 이를 보고하는 바이다.

  • PDF

광중합 복합레진 INLAY 수복물의 변연누출에 관한 실험적 연구 (IN VITRO STUDY ON MARGINAL LEAKAGE OF COMPOSITE RESIN INLAY RESTORATIONS)

  • 유제국;배정식;이호용
    • 대한치과보철학회지
    • /
    • 제26권1호
    • /
    • pp.85-98
    • /
    • 1988
  • The primary aim of this study was to access the degree of marginal leakage in composite resin inlay restorations. Class V cavities were prepared on sixty extracted premolars. They were classified as control group and experimental group 1, 2 and each group was filled with BIS-FIL $I^{(R)}$ and $Silux^{(R)}$ composite resins. In the control group, the composite resin was inserted directly, the experimental group 2 was inserted as composite resin inlay after heat treatment on $125^{\circ}C$, 10 minutes. Then thermocycling was performed 1000 times. After staining with 1% Basic Fuchsin, they were cut in Buccolingual direction and the degree of penetration of the dye was examined under L/M. The following results were obtained : 1. In occlusal margin area, difference in marginal leakage was not observed in all groups. 2. In gingival margin area, cavities filled with composite resin inlay was less marginal leakage than filled directly in BIS-FIL $I^{(R)}$ group, and statistical significant difference was not existed in $Silux^{(R)}$ group. 3. The statistical significance was not existed between composite resin inlay and composite resin inlay heated secondarily. 4. In all groups, gingival margin area reveals more marginal leakage than occlusal margin area and statistical significance was existed.

  • PDF

복합레진 인레이의 표면처리방법에 따른 표면특성 비교 (Comparison of surface characterization according to surface treatment of composite resin inlay)

  • 이명진;최유리;강민경
    • 한국치위생학회지
    • /
    • 제19권2호
    • /
    • pp.307-315
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the characterization of composite resin inlay surface with silane and non-thermal atmospheric pressure plasma treatment. Methods: Composite resin inlay was used as a specimen, which was treated by sandblasting + silane and sandblasting + plasma. The untreated specimens were assigned to the control group. Specimens were analyzed for surface roughness, color change, and chemical composition. Statistical analyses were performed using one-way ANOVA test (p<0.05). Results: The present findings showed that the roughness and color changes of the plasma-treated surface were significantly lower than those of the silane-treated surface. In addition, a change in the chemical composition was observed on the plasma-treated surface. Conclusions: Based on the results, non-thermal atmospheric pressure plasma could be a potential tool for the cementation of composite resin inlay.

Die spacer의 두께에 따른 복합레진 inlay의 치은 변연부 미세누출 및 접착양태에 관한 연구 (GINGIVAL MARGIAL LEAKAGE AND BONDING PATTERN OF THE COMPOSITE RESIN INLAY ACCORDING TO VARIOUS THICKNESS OF DIE SPACER)

  • 박태일;신동훈;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.152-163
    • /
    • 1995
  • This experiment was performed to observe the adhesion pattern and microleakage in the gingival margin according to variation in the resin cement thickness which results from thickness of Die spacer. which is considered to effect the adaptability of the composite resin inlays. Clearfil CR inlays were fabricated on stone models with CR Sep applicated once and Nice fit twice, 4 times, and 6 times each. After 2nd curing within the CRC-100 oven, CR inlays were cemented with CR inlay cement. Dye(2% methylene blue) penetration and adhesion pattern were evaluated after sectioning of gingival margin into :3 pieces. The results were as follows ; 1. The thickness of resin cement showed unevenchanging pattern with that of die spacer, namely, it was increased until 4 times' application of Nice-Fit but was decreased with 6 times' application of that. 2. The degree of dye penetration wasn't affected by cement thickness within a limited value. 3. Most of dye penetration was shown through the interface between cement and enamel rather than the interface between cement and CR inlay. This shows that the affinity of resin cement for CR inlay was superior to the adhesive strength with tooth structure. 4. No gap was found at the interface between enamel and cement but some showed separation between dentin and cement. It is concidered that the contraction force of cement was less than the bond strength with the enamel. 5. Lots of voids were found in the CR inlay and resin cement. There was a pooling tendency of bonding agent and cement in the axiogingival line angle portion. 6. In some specimens, cracks were shown in enamel margin. From this it could be considered that cavity preparation and surface treatment weakened the tooth structure.

  • PDF

합착방법(合着方法)에 따른 복합(複合)레진 인레이의 변연폐쇄효과(邊緣閉鎖效果) (THE MARGINAL SEALING EFFECT OF COMPOSITE RESIN INLAYS ACCORDING TO THE LUTING TECHNIQUES)

  • 문영덕;조규징
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.121-132
    • /
    • 1991
  • The purpose of the study was to evaluate the marginal sealing effect of composite resin inlays according to the luting techniques and compare them to the conventional direct resin filling technique. 90 cavities of class V were prepared on the buccal surface of 90 extracted molar teeth, which were divided into four groups. Cavities of control group were directly filled with Scotchbond 2 and P - 50, and those of composite resin inlay groups were luted with one of the followings: Adhesive bond followed by Adhesive cement, All bond followed by Adhesive cement, Fuji - ionomer type L All the specimens were immersed in India ink dye solution for 7 days at $37^{\circ}C$ incubator after thermocycling between $5^{\circ}C$ and $60^{\circ}C$ and longitudinally sectioned with diamond disk inot two parts All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The results were as follows: 1. Groups filled with composite resin inlay showed less marginal leakage than the group directly filled(p<0.01). 2. There was no significant difference in marginal leakage between composite resin inlay groups luted with Adhesive bond followed by Adhesive cement and the group luted with All bond followed by Adhesive cement(p>0.05). 3. At occlusal margins, Composite resin inlay group luted with Adhesive bond followed by Adhesive cement showed less marginal leakage than the group luted with Fuii ionomer type I(p<0.01). At gingival margins, composite resin inlay group luted with All bond followed by Adhesive cement showed less marignal leakage than the group luted with Fuji ionomer type I(P<0.01).

  • PDF

2급 와동 복합레진 인레이 충전 후 변연누출에 관한 연구 (A STUDY ON THE MARGINAL LEAKAGE OF CLASS II COMPOSITE RESIN INLAY)

  • 강현숙;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.191-205
    • /
    • 1992
  • The purpose of this study was to evaluate the microleakage of class II composite resin inlays and compare them with the conventional light-cured resin filling restorations. Class II cavities were prepared in 60 extracted human molars with which cervical margins were located below 1.0mm at the cemento-enamel junction using No. 701 tapered fissure carbide bur. All of the prepared cavities were restored as follows and divided into 6 groups. Group I and 2 were restored using direct filling technique and group 3,4,5 and 6 were restored using direct inlay technique that was cemented with dual-cured resin cements. group I: Cavities were restored with light-curing composite resin, Brilliant Lux. group 2. Cavities were restored with light-curing composite resin, Clearfil PhotoPosterior. group 3: Cavities were restored with Clearfil CR Inlay and heat treated at $125^{\circ}C$ for 7 minutes. group 4: Cavities were restored with same material as group 3 and heat treated at $100^{\circ}C$ for 15 minutes. group 5: Cavities were restored with Brilliant (Indirect esthetic system) and heat treated at $125^{\circ}C$ for 7 minutes. group 6: Cavities were restored with same material as group 5 and heat treated at $100^{\circ}C$ for 15 minutes. All specimens were polished with same method and thermocycled between $6^{\circ}C$ and $60^{\circ}C$, then immersed in a bath of 2.0% aqueous solution of basic fuchsin dye for 24 hours. Dyed specimens were sectioned longitudinally and dye penetration degree was read on a scale of 0 to 4 by Tani and Buonocore's method 45). The results were as follows: 1. Microleakage was observed rather at the cervical margins than at the occlusal margins in all groups. 2. Composite resin inlay groups showed significantly less leakage than direct filling groups at the cervical margins (p < 0.001). 3. In composite resin inlay groups, there was no significant difference in microleakage between specimens by heat treating temperature and time (p > 0.05). 4. There was no significant difference in leakage between each groups at the occlusal margins (p > 0.05).

  • PDF

복합레진 인레이 수복시 와동형태에 따른 치아파절에 관한 유한요소법적 연구 (A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS WITH CAVITY DESIGN ON FRACTURE OF COMPOSITE RESIN INLAY RESTORED TOOTH)

  • 김철순;민병순
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.231-254
    • /
    • 1994
  • Fracture of cusp, on posterior teeth, especially those carious or restored, is major cause of tooth loss. Inappropriate treatments, such as unnecessarily wide cavity preparations, increase the potential of further trauma and possible fracture of the remaining tooth structures. Fracture potential may be directly related to the stresses exerted upon the tooth during masticatory function. The purpose of this study is to evaluate the fracture resistance of tooth, restored with composite resin inlay. In this study, MOD inlay cavity prepared on maxillary first premolar and restored with composite resin inlay. Three dimensional finite element models with eight nodes isoparametric solid element, developed by serial grinding-photographing technique. These models have various occlusal isthmus and depth of cavity, 1/2, 1/3 and 1/4 of isthmus width and 0.7, 0.85 and 1.0 of depth of cavity. The magnitude of load was 474 N and 172 N as presented to maximal biting force and normal chewing force. These loads applied onto ridges of buccal and lingual cusp. These models analyzed with three dimensional finite element method. The results of this study were as follows : 1. There is no difference of displacement between width of occlusal isthmus and depth of cavity. 2. The stress concentrated at bucco-mesial comer, bucco-disal comer, pulpal line angle and the interface area between internal slopes of cusp and resin inlay. 3. The vector of stress direct to buccal and lingual side from center of cavity, to tooth surface going on to enamel. The magnitude of vector increase from occlusal surface to cervix. 4. The crack of tooth start interface area, between internal slop of buccal cusp and resin inlay. It progresses through buccopulpal line angle to cervix at buccomesial and buccodistal comer. 5. The influence with depth of cavity to fracture of tooth was more than width of isthmus. 6. It would be favorable to make the isthmus width narrower than a third of the intercuspal distance and depth of cavity is below 1 : 0.7.

  • PDF

수복재와 이장재에 따른 응력과 온도 분포의 유한 요소 분석 (FINITE ELEMENT ANALYSIS OF STRESS AND TEMPERATURE DISTRIBUTION AFFECTED BY VARIOUS RESTORATIVE AND BASE MATERIAL)

  • 이재영;오태석;임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.321-337
    • /
    • 2000
  • Dental caries, one of the most frequent dental disease, become larger because it can be thought as a simple disease. Further more, it can progress to unexpected root canal therapy with fabrication of crown that needs reduction of tooth structure. Base is required in a large caries and ZOE, ZPC, glass ionomer are used frequently as base material. They, with restorative material, can affect the longevity of the restoration. In this study, we assume that the mandibular 1st molar has deep class I cavity. So, installing the 3 base material, 3 kinds of fillings were restored over the base as follows; 1) amalgam only, 2) amalgam with ZPC, 3) amalgam with ZOE, 4) amalgam with GI cement, 5) gold inlay with ZPC, 6) gold inlay with GI cement, 7) composite resin only, 8) composite resin with GI cement. After develop the 3-dimensional model for finite element analysis, we observe the distribution of stress and temperature with force of 500N to apical direction at 3 point on occlusal surface and temperature of 55 degree, 15 degree on entire surface. The analyzed results were as follow : 1. Principal stress produced at the interface of base, dentin, cavity wall was smallest in case of using GI cement as base material under the amalgam. 2. Principal stress produced at the interface of base, dentin, cavity wall was smaller in case of using GI cement as a base material than ZPC under gold inlay. 3. Composite resin-filled tooth showed stress distributed over entire tooth structure. In other words, there was little concentration of stress. 4. ZOE was the most effective base material against hot stimuli under the amalgam and GI cement was the next. In case of gold inlay, GI cement was more effective than ZPC. 5. Composite resin has the small coefficient of thermal conductivity. So, composite resin filling is the most effective insulating material.

  • PDF

수종 이원중합 레진 씨멘트의 중합률 및 세포 독성에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE DEGREE OF CONVERSION AND CYTOTOXICITY OF DUAL CURE RESIN CEMENTS)

  • 노병덕;박성호;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.33-54
    • /
    • 1995
  • The degree of conversion of composite resin was known to have influence on the mechanical properties of composite materials such as hardness, strength, wear resisitance, dimensional and color stability. Also unreacted monomer was reported to be harmful to the pulp. So the degree of conversion was a very important factor in the success of composite resin restorations. In recent, the dual cure resin cement was developed with the advocations that it could increase the curing rates in the sites where the curing ligt could not reach. Moreover many manufactors added some adhesive components in the resin cement. This study was undertaken to observe the effects of curing depth and light curing times on the degree of conversion of dual cure resin cements. CR INLAY CEMENT, DUAL CEMENT and OPTEC BOND, by the Fourier transform Infrared analysis, changing the curing depth 1mm, 2mm and 3mm, and varying the light curing time 20 seconds, 40 seconds and 80 seconds at each depth. The cytotoxicity of dual cure resin cements was tested by the in vitro MTT method using L929 cell. The results was evaluated and compared statistically. The results were obtained as follows : 1. The dual cure resin cements reavealed various degree of conversion, CR INLAY CEMENT and DUAL CEMENT had a tendency to be more reactive to the light cure and OPTEC BOND was a more chemical one. 2. CR INLAY CEMENT and DUAL CEMENT showed the lowest degree of conversion in 2 mm depth, and in 3mm depth the degree of conversion increased, which were due to the chemical cure of dual cures, but OPTEC BOND showed decreasing degree of conversion with increasing curing dept h and all experimental groups showed lower degree of conversion than CHEMICAL group which cured in dark room with no light, so the weak light-curing of dual cure resin cement prevented the chemical cure. (P<0.05) 3. CR INLAY CEMENT and DUAL CEMENT showed increasing degree of conversion in 1 mm and 3 mm, according to the increasing cure times, but in 2 mm depth the degree of conversion decreased with increasing light-curing times and OPTEC BOND showed contrary tendency, but there was no ststistical importance in the differences among the experimental group.(P>0.05) 4. The optical density by MTT assay of extractions of CR INLAY CEMENT, DUAL CEMENT and OPTEC BOND revealed no statitically important differences comparing with optical density of negative control.(P>0.05) 5. CR INLAY CEMENT showed a tendency of increaing cytotoxicity with days and DUAL CEMENT and OPTEC BOND showed higher cytotoxicity in 2 days than in 4 days, but there was no statistical importance in the differences.(P>0.05).

  • PDF