• Title/Summary/Keyword: Resin filling analysis

Search Result 80, Processing Time 0.027 seconds

Awareness & satisfaction of caregivers on the health insurance coverage of light-curable composite resin restoration (광중합형 복합레진 충전 건강보험 급여화에 대한 보호자의 인식과 만족도)

  • Yu, Sl-A;Lee, Su-Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.21 no.1
    • /
    • pp.89-98
    • /
    • 2021
  • Objectives: The purpose of this study was to investigate the perception and satisfaction of caregivers and parents after being covered by health insurance for light-curing composite resin fillings, and to contribute to the settlement of the expansion and coverage of health insurance. Methods: A survey was conducted on caregivers who visited two dental institutions in the Gyeonggi-do area, and parents who joined internet cafes (online communities) in the Gyeonggi-do area from June 2 to September 2, 2020. 225 responses were collected eventually, and 212 valid responses were used as analysis data. Results: 67.0% of the study subjects were aware of the permanent teeth resin fillings being covered by health insurance and the satisfaction was relatively high (91.5%). There was a statistically significant difference in the perception of permanent tooth resin filling benefits according to the child's oral condition (p=0.025) and the parents' own interest in oral health (p=0.039). Conclusions: Based on the results of this study, it is necessary to increase the accessibility to the initial treatment for dental care of children through active promotion of detailed items of permanent teeth resin fillings.

Analysis of Filling in Injection Molding with Compressibility (압축성을 고려한 사출성형 충전과정에 관한 연구)

  • Han, Kyeong-Hee;Im, Yong-Taek
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.5
    • /
    • pp.735-745
    • /
    • 1997
  • In this study, the compressibility of resin was considered in filling analysis to account for the possible packing type flow. A numerical simulation program employing a hybrid finite element/finite difference scheme was developed to solve Hele-Shaw flow of the compressible viscous fluid at non-isothermal conditions. To advance the melt front, a control volume approach was adopted. Thin complex 3-D shapes of cavities, runners, and sprues were discretized by employing triangular, cylindrical and/or rectangular strip elements. Mass conservation was applied to each control volume to solve for the pressure distribution. Directly applying a constant mass flow rate at the inlet removes calculation of the apparent pressure boundary conditions, resulting in better simulation condition. The Cross model was used to model viscosity and the Tait equation was employed to represent density as a function of temperature and pressure. The validity of the developed program was verified through comparisons with available data in the literature and the effect of compressibility on the pressure distribution was discussed. To reduce computation time, 1-D and 2-D elements were used instead of applying triangular elements and the numerical results were compared to each other.

Evaluation of Formability Dependent on the Location of Injection Gate of Vertical Machining Center ATC Tool Port Using Injection Molding Analysis (사출성형해석을 이용한 수직머시닝센터 ATC 툴 포트의 사출 게이트 위치에 따른 성형성 평가)

  • Lee, Yu-Wool;Park, Chul-Woo;Kim, Jin-Rok;Choi, Hyun-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.12
    • /
    • pp.129-135
    • /
    • 2021
  • Injection molding is a manufacturing method of melting the polymer resin and injecting it into a mold to molding it into the desired form. Due to the short molding time and outstanding formability, complex products can be shaped with high precision and it is the most widely used polymer molding method. However, there may be areas that are not filled depending on the location of the injection gate where polymer resin is injected. Formability is determined by deformation and surface precision due to the impact of residual stress after molding. Hence, choosing the location of the injection gate is very important and molding analysis of injection molding is essential to reduce the cost of the mold. This study evaluated the injection formability based on the location of the injection gate of the vertical machining center ATC tool port using injection molding analysis and the results were compared and analyzed. Injection molding analysis was conducted on filling, packing, and deformation according to the location of the gate of the ATC tool port. From each injection gate location, filling time, pressure, and maximum deformation were compared. At gate 2, conditions of molding time and the location of the gate were far superior in production and quality. Gate 2 produced the smallest deformation of 0.779mm with the best quality.

A Study of Shrinkage Phenomena on Injection modeled Pa Metal Insert (금속 인서트 사출 성형품의 수축 현상에 관한 연구)

  • 김영수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.112-118
    • /
    • 1999
  • Shrinkage behavior was investigated to obtain more accurate dimensions of injected molding parts for free and restricted shrinkage conditions. various parameters for metal inserted injection process, such as thickness of resin, holding pressure and time, mo이 temperature and restriction condition of mold, were considered for the analysis of shrinkage phenomena. For numerical analysis, MOLDFLOW software was used to find the deterministic parameters of filling time, temperature, pressure and holding time. Also , experimental shrinkage effects were measured through actual injection molding process and the resin thickness was under controlled as 3 mm , 5 mm, and 7mm for the shapes of plastic gear made of Polymide(PA) and Polyxymethlene(POM). The main parameters of these injection processes were found to be holding pressure, holding time and mold temperature in the case of metal inserted molding.

  • PDF

A Study on Simplifying Flow Analysis of VaRI Process (VaRI 공정 유동해석 간소화 방법에 대한 연구)

  • Kim, Yeongmin;Lee, Jungwan;Kim, Jungsoo;Ahn, Sehoon;Oh, Youngseok;Yi, Jin Woo;Kim, Wiedae;Um, Moon-kwang
    • Composites Research
    • /
    • v.34 no.4
    • /
    • pp.233-240
    • /
    • 2021
  • VaRI(Vacuum assisted Resin Infusion) process, which is cost effective and suitable for manufacturing large-sized composites, is an OoA(Out-of Autoclave) process. For rapid resin infusion in the VaRI process, a DM(distribution media) is placed on top of the fabric. The resin is rapidly supplied in plane direction of the fiber along the DM, and then the supplied resin is impregnated in the out-of-plane direction of fiber. It is difficult to predict the flow of resin because the flow of in-plane direction and the out-of-plane direction occur together, and a 3D numerical analysis program is used to simulate the resin infusion process. However, in order to analyze in 3D, many elements are required in the out-of-plane direction of fabric. And the product size is larger, the longer the analysis time needs. Therefore, in this study, a method was suggested to reduce the time required for flow analysis by simplifying the 3D flow analysis to 2D flow analysis. The usefulness was verified by comparing the 3D flow analysis with the simplified 2D flow analysis at the same conditions. The filling time error was about 7% and the reduction of flow analysis time was about 95%. In addition, by utilizing the constant difference in the flow front between the top, middle, and bottom of the fabric of the 3D analysis, the flow front of the top, middle, and bottom of the fabric can be also predicted in the 2D flow analysis.

Push-out bond strength of a self-adhesive resin cement used as endodontic sealer

  • Gurgel-Filho, Eduardo Diogo;Lima, Felipe Coelho;Saboia, Vicente De Paula Aragao;Coutinho-Filho, Tauby De Souza;Neves, Aline De Almeida;da Silva, Emmanuel Joao Nogueira Leal
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.282-287
    • /
    • 2014
  • Objectives: The aim of the present study was to investigate the bond strength of RelyX Unicem (3M) to root canal dentin when used as an endodontic sealer. Materials and Methods: Samples of 24 single-rooted teeth were prepared with Gates Glidden drills and K3 files. After that, the roots were randomly assigned to three experimental groups (n = 8) according to the filling material, (1) AH Plus (Dentsply De Trey GmbH)/Gutta-Percha cone; (2) Epiphany SE (Pentron)/Resilon cone; (3) RelyX Unicem/Gutta-Percha cone. All roots were filled using a single cone technique associated to vertical condensation. After the filling procedures, each tooth was prepared for a push-out bond strenght test by cutting 1 mm-thick root slices. Loading was performed on a universal testing machine at a speed of 0.5 mm/min. One-way analysis of variance and Tukey test for multiple comparisons were used to compare the results among the experimental groups. Results: Epiphany SE/Resilon showed significantly lower push-out bond strength than both AH Plus/Gutta-Percha and RelyX Unicem/Gutta-Percha (p < 0.05). There was no significant difference in bond strength between AH Plus/Gutta-Percha and RelyX Unicem/Gutta-Percha (p > 0.05). Conclusions: Under the present in vitro conditions, bond strength to root dentin promoted by RelyX Unicem was similar to AH Plus. Epiphany SE/Resilon resulted in lower bond strength values when compared to both materials.

FINITE ELEMENT ANALYSIS OF STRESS AND TEMPERATURE DISTRIBUTION AFFECTED BY VARIOUS RESTORATIVE AND BASE MATERIAL (수복재와 이장재에 따른 응력과 온도 분포의 유한 요소 분석)

  • Lee, Jae-young;Oh, Tae-Suk;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.321-337
    • /
    • 2000
  • Dental caries, one of the most frequent dental disease, become larger because it can be thought as a simple disease. Further more, it can progress to unexpected root canal therapy with fabrication of crown that needs reduction of tooth structure. Base is required in a large caries and ZOE, ZPC, glass ionomer are used frequently as base material. They, with restorative material, can affect the longevity of the restoration. In this study, we assume that the mandibular 1st molar has deep class I cavity. So, installing the 3 base material, 3 kinds of fillings were restored over the base as follows; 1) amalgam only, 2) amalgam with ZPC, 3) amalgam with ZOE, 4) amalgam with GI cement, 5) gold inlay with ZPC, 6) gold inlay with GI cement, 7) composite resin only, 8) composite resin with GI cement. After develop the 3-dimensional model for finite element analysis, we observe the distribution of stress and temperature with force of 500N to apical direction at 3 point on occlusal surface and temperature of 55 degree, 15 degree on entire surface. The analyzed results were as follow : 1. Principal stress produced at the interface of base, dentin, cavity wall was smallest in case of using GI cement as base material under the amalgam. 2. Principal stress produced at the interface of base, dentin, cavity wall was smaller in case of using GI cement as a base material than ZPC under gold inlay. 3. Composite resin-filled tooth showed stress distributed over entire tooth structure. In other words, there was little concentration of stress. 4. ZOE was the most effective base material against hot stimuli under the amalgam and GI cement was the next. In case of gold inlay, GI cement was more effective than ZPC. 5. Composite resin has the small coefficient of thermal conductivity. So, composite resin filling is the most effective insulating material.

  • PDF

An Analysis of the Job Performance in Operative Restoration by Dental Hygienists (치과위생사의 치과보존분야 직무수행 현황 분석)

  • Cho, Pyeong-Kyu
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.277-291
    • /
    • 2004
  • The purpose of this study is to analyze the dental hygienists' overall performance in operative restoration and the clinical performance in operative restoration according to dental hygienists' career and to provide basic data for establishing the appropriate range of dental hygienists' work. Subjects of this study are 339 dental hygienists working at dental clinic and hospital nationwide, selected by their working place, career, type of clinic, and location of clinical institution. The distribution of people who responded to the survey shows that 81 belong to beginner level(less than 2 years since entering clinic), 115 intermediate level(2 to 3 years since entering clinic), 81 higher level(4 to 5 years since entering clinic) and 62 advanced level(more than 6 years since their entering clinic). In terms of the types of clinical institution, 178 belong to dental clinics and 161 belong to dental hospitals. The survey used in this study are focused on perception about clinical performance in operative dentistry and adequacy of the work. Operative dentistry consists of operative restoration and endodontic therapy. The operative restoration consists of 15 categories such as patient welcoming, examination and diagnosis, planning of treatment, anesthesia, control of moisture, cavity preparation, pulp protection, matrix band application, amalgam filling, resin filling, glass ionomer cement filling, abrasive strip removal, rubber dam removal, bite check and polishing, patient education, and arrangement. The reliability was Cronbach's Alpha .9453. SPSS 10.0 for Windows was used to analyze the responses. One way ANOVA was utilized to verify the differences in the dental hygienists' job performance in operative restoration and their job performance according to career. When significant difference was found. Duncan multi comparison post hoc was done. To sum up the results of this study, patient welcoming look the first place in the operative restoration. It was followed by patient education, examination and diagnosis, introducing treatment plan, resin filling, glass ionomer cement filling, amalgam filling, bite check and polishing, anesthesia, pulp protection, control of moisture, abrasive strip removal, cavity preparation, matrix band application, rubber dam removal, and anesthesia. In terms of the clinical performance by career, there were significant differences in 19 activities such as medical eraluation, oral examination, patient charting, intra oral readio graphs, firm developing fixing mounting, curing light gun, education of attention content after operation. Based on the results of this study, the specific range of operative restoration for dental hygienists should be focused on providing basic data for dentists' diagnosis, alleviation of fear and aching accompanied by injection and anesthesia, data providing for dentists' decision of anesthesia degree, and maximization of control of moisture.

  • PDF

THE MARGINAL SEALING EFFECT OF COMPOSITE RESIN INLAYS ACCORDING TO THE LUTING TECHNIQUES (합착방법(合着方法)에 따른 복합(複合)레진 인레이의 변연폐쇄효과(邊緣閉鎖效果))

  • Moon, Young-Deok;Cho, Kyeu-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.121-132
    • /
    • 1991
  • The purpose of the study was to evaluate the marginal sealing effect of composite resin inlays according to the luting techniques and compare them to the conventional direct resin filling technique. 90 cavities of class V were prepared on the buccal surface of 90 extracted molar teeth, which were divided into four groups. Cavities of control group were directly filled with Scotchbond 2 and P - 50, and those of composite resin inlay groups were luted with one of the followings: Adhesive bond followed by Adhesive cement, All bond followed by Adhesive cement, Fuji - ionomer type L All the specimens were immersed in India ink dye solution for 7 days at $37^{\circ}C$ incubator after thermocycling between $5^{\circ}C$ and $60^{\circ}C$ and longitudinally sectioned with diamond disk inot two parts All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The results were as follows: 1. Groups filled with composite resin inlay showed less marginal leakage than the group directly filled(p<0.01). 2. There was no significant difference in marginal leakage between composite resin inlay groups luted with Adhesive bond followed by Adhesive cement and the group luted with All bond followed by Adhesive cement(p>0.05). 3. At occlusal margins, Composite resin inlay group luted with Adhesive bond followed by Adhesive cement showed less marginal leakage than the group luted with Fuii ionomer type I(p<0.01). At gingival margins, composite resin inlay group luted with All bond followed by Adhesive cement showed less marignal leakage than the group luted with Fuji ionomer type I(P<0.01).

  • PDF

Experimental Study on implementation of injection molding process for speaker frame in LED TV (LED TV 스피커 프레임용 사출 성형공정 구현에 관한 실험적 연구)

  • Lee, Sun Kon;Kim, Sang Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.94-101
    • /
    • 2013
  • Injection molding process is one of the most important methods to produce plastic parts with high efficiency and low cost. The objective of this study is to implement the best plastic injection molding process for LED TV speaker frame. Moldflow analysis and simulation of plastic injection molding process were carried out in order to predict optimal modeling operation conditions and then injection molded part was produced various type of resin temperature, filling time and injection pressure variation. the result was that the best injection molding condition is set as 60bar pressure, 2sec filling time and $310^{\circ}C$ degree. The study result would be useful to variety of plastic injection molding process.