• Title/Summary/Keyword: Residuals treatment

Search Result 38, Processing Time 0.023 seconds

Recovery Increase by Recycling Backwash Residuals in Microfiltration System

  • Yu, Myong-Jin;Pak, Hong-Kyoung;Sung, Il-Wha
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.13-21
    • /
    • 2008
  • With the rise in membrane applications, residuals management has become a growing challenge for membrane system. The primary residuals of MF/UF (microfiltration/ultrafiltration) system results from the wastes generated during backwashing. Many regulatory agencies, utilities, and water process engineers are unfamiliar with the characteristics and methods for treatment and disposal of membrane residuals. Therefore, this study was performed to investigate the backwash residuals water quality from the pressurized system with and without pre-coagulation, and to suggest approaches for the backwash residuals treatment. Pressurized MF system was installed at Guui water intake pumping station and operated with raw water taken from the Han River. We compared performances with and without the recycling backwash residuals at flux conditions, 50 LMH and 90 LMH with and without pre-treatment (coagulation). Based on the results, recycling of backwash residuals in pressurized system with pre-coagulation showed applicability of backwash residuals managements. Moreover, the recovery rate also increased up to over 99%.

Estimation on the Design Capacities of Residuals Treatment Facilities by the Quantity of Dewatered Sludge Generated from Water Treatment Plants (정수장에서 발생된 탈수슬러지의 량에 의한 배출수처리시설용량에 대한 평가)

  • Moon, Yong-Taik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.715-723
    • /
    • 2004
  • The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS occurs under quiescent conditions in the primary clarifier, where suspended solids are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. The relative solid and liquid fractions of a slurry are most commonly described by the solids concentration, expressed as mg/L or percent solids. The purpose of the present investigation is to estimate a suitability on the design capacities of residuals treatment facilities by the quantity of dewatered sludge generated from water treatment plants.

Evaluation of Design Parameter on Residuals Treatment Facilities in Membrane Water Treatment Plants (막여과 정수장에서의 배출수처리시설 설계인자 평가)

  • Moon, Yong-Taik;Seo, In-Seok;Kim, Hong-Suck;Park, No-Suk;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.138-146
    • /
    • 2006
  • The characteristics of backwash and concentrate discharges depend upon the quality of the water being treated and the net recovery of the membrane system. This paper is to indicate a design methods on the capacities of residuals treatment facilities in membrane processes for drinking water. We operated a demonstration membrane plant with a recovery rate of 90% for designing G-water treatment plant. We investigated on design parameter (optimum coagulant dosage and surface loading rate etc.) to design efficiently the residuals treatment facilities. The settling test was conducted with 1m columns dosing PACl to kaolin and membrane residuals under the experimental condition that discharge permit was under a 60mg/L. When the quantity of membrane residuals was $1,575m^3/day$, the estimated results for 1st thickener demonstrated the surface loading rate of 14.4m/day, detention time of 5.83hr, available depth of 3.5m.

Settling Characteristics of Water Treatment Plant Sludges by Pretreatment Methods (정수장슬러지의 전처리에 의한 침전특성)

  • Moon, Yong-taik;Lee, Sun-ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.627-632
    • /
    • 2008
  • It is necessary to investigate methods for improvement by diagnosing sludge settling characteristics on inflow of slurry to thickener. The results of the settling tests are correlated to determine zone settling velocities at the various sludge solids concentrations. Conditioning of WTP residuals is generally done by either chemical or physical treatment. The settling test was conducted with 1m columns dosing polymer to WTP residuals at various solids concentration. The estimated results for dosing to WTP residuals for a sludge of 2,100 ~ 16,012 mg/L solids concentration were the zone settling velocities of 48.38 ~ 6.8 m/day, supernatant solid concentration of 3.2 ~ 19 mg/L and solid flux of $101.6{\sim}317.61kg/m^3{\cdot}day$. The values for non-polymer treatment were the zone settling velocities of 28.37 ~ 0.12 m/day, supernatent solid concentration of 8.5 ~ 108 mg/L and solid flux of $59.58{\sim}1.92kg/m^2{\cdot}day$. The limiting solid flux value by Yoshioka methods was $4.0kg\;TS/m^3{\cdot}day$ for Non-polymer and $228.0kg\;TS/m^3{\cdot}day$ for dosing polymer. These results are to indicate a possibility of improvement on the thickening characteristics and the quality of supernatant as increasing the settling velocities by dosing polymer to WTP residuals.

A study about treatment for water treatment residual sludge using submerged membrane system (침지식 막여과 공정을 이용한 정수장 배출수 처리에 관한 연구)

  • Kim, Jun-Hyun;Lee, Ju-Hyung;Moon, Baek-Su;Kwak, Young-Ju;Jang, Jung Woo;Kim, Jinho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.181-193
    • /
    • 2014
  • Various treatment system for residuals have applied to save water resources, but most of them were not be satisfied with legal standard consistently. In this study, submerged membrane treatment system was operated to treat water treatment plant residuals and operation parameters was evaluated. Result of this experiment, high concentration organic matters contributed to high increase Transmembrane pressure(TMP) of membrane system(from 0.05 bar to 0.35 bar). And backwash process was effective to stabilize membrane system operation. After Cleaning-In-Place(CIP), permeability was recovered about 100 % from first operation condition. Inorganic matters (Fe, Mn, Al, Ca, Mg) were not effective membrane filtration performance. The quality of residual treatment was satisfied with drinking water quality standard and a treated water from that system was suitable for water reuse.

Nonparametric Method using Placement in an Analysis of a Covariance Model

  • Hwang, Dong-Min;Kim, Dong-Jae
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.5
    • /
    • pp.721-729
    • /
    • 2012
  • Various methods control the influence of a covariate on a response variable. These methods are analysis of covariance(ANCOVA), RANK ANCOVA, ANOVA of (covariate-adjusted) residuals, and Kruskal-Wallis tests on residuals. Covariate-adjusted residuals are obtained from the overall regression line fit to the entire data set that ignore the treatment levels or factors. It is demonstrated that the methods on covariate-adjusted residuals are only appropriate when the regression lines are parallel and covariate means are equal for all treatments. In this paper, we proposed the new nonparametric method on the ANCOVA model, as applying joint placement in a one-way layout on residuals as described in Chung and Kim (2007). A Monte Carlo simulation study is adapted to compare the power of the proposed procedure with those of the previous procedure.

Relationship between Bacterial Regrowth and Free chlorine Residuals in Water Distribution System

  • Lee, Yoon-Jin;Yoon, Tae-Ho;Jun, Byong-Ho;Oh, Kyoung-Doo;Nam, Sang-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.136-139
    • /
    • 2003
  • This study is to observe the occurrence of heterotrophic bacteria in terms of free chlorine residuals in two different water distribution system which belongs to both K and Y water treatment plant of S city of Korea. The data analyzing in distribution systems (DS) shows that the free chlorine residuals decrease from 0.10 to 0.56 mgmg/L for K, and 0.51 to 0.78 mg/L for Y. The decay of free chlorine is clearly higher in both March and August than those of in January. The HPC in DS are ranged from 0 to 40 CFU/mL for K, 0 to 270 CFU/mL for Y, on R2A medium. In particular, its level is relatively high at consumers ground storage tanks, taps and point-of-end area of Y. The predominant genera is studied in distribution systems are Acinetobacter, Sphingomonas (branch of Pseudomonas), Micrococcus, Bacillus, Staphylococcus. The diversity of heterotrophic bacteria increase in the end-point area. Most of them are either encapsulated cells or cocci of gram-positve. In conclusion, the point-of-end area in distribution systems shows the longer flow distance from water treatment plants, the greater diversity and higher level of heterotrophic bacteria due to the significant decay of free chlorine residuals.

  • PDF

Bacterial Regrowth in Water Distribution Systems and Its Relationship to the Water Quality: Case Study of Two Distribution Systems in Korea

  • Yoon, Tae-Ho;Lee, Yoon-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.262-267
    • /
    • 2004
  • This study was done to observe the occurrence of heterotrophic bacteria in terms of free chlorine residuals in two different water distribution systems, which belongs to both K and Y water treatment plant of S city in Korea. The data analyzed in the distribution systems show that the free chlorine residuals decreased from 0.10 to 0.56 mg/l for K, and 0.51 to 0.78 mg/l for Y. The decay of free chlorine is clearly higher in both March and August than in January. The HPC in the distribution systems are ranged from 0 to 40 cfu/ml for K, 0 to 270 cfu/ml for Y, on $R_2$A medium. In particular, its level is relatively high at the consumer's ground storage tanks, taps, and the point-of-end area of Y. The predominant genera that were studied in the distribution systems were Acinetobacter, Sphingomonas (branch of Pseudomonas), Micrococcus, Bacillus, Staphylococcus. The diversity of heterotrophic bacteria increases in the end-point area. Most of them are either encapsulated cells or of Gram-positve cocci. In conclusion, the point-of-end area in distribution systems shows the longer flow distance from the water treatment plants, along with a greater diversity and a higher level of heterotrophic bacteria, due to the significant decay of free chlorine residuals.

Characteristics of residuals from the 2nd-stage microfiltration in a dual membrane process (침지식 2단 막여과 고도 정수처리 시스템의 최종배출수 특징)

  • Lee, Seung Ryul;Kweon, Ji Hyang;Hur, Hyung Woo;Yeon, Kyeong Ho;Park, Ki Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.31-37
    • /
    • 2009
  • Low-pressure membrane processes have been extensively expanded their applications to drinking water production in a few decades. As a capacity of a membrane plant becomes greater in recent years, proper methods to increase water production as well as to treat residuals have drawn great attention. A possible treatment option for the better water production is to apply a dual membrane system. The second stage microfiltration was installed and operated for approximately six months. The residuals from the two stage microfiltration were investigated to learn their characteristics in settling and dewatering processes. The settlability of the membrane residuals were greatest at the SS concentration of approximately 15000mg/L. The proper dose of the polyelectrolytes for filterability were obtained in the range of 0.5~1%. In the dosage range, the water contents of the membrane residuals were greater but the SRF were lower than the residual from the conventional process.

Analysis of the sludge thickening characteristics in the thickener using CFD Model (CFD를 이용한 농축조 슬러지의 유출흐름특성 해석)

  • Park, No-Suk;Moon, Yong-Taik;Kim, Byung-Goon;Kim, Hong-Suck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.777-782
    • /
    • 2011
  • The residual treatment facilities in WTP(water treatment plant) play an important role in solid-liquid separation. At present, it is difficult to solve problems related with thickening and dewatering of WTP sludge, and discharging waste water to river. The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS(Suspended Solid) occurs under quiescent conditions in the primary clarifier, where SSs are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. In this study, Drawing characteristics of the sludge thickening in the thickener of Water Treatment Plants was simulated by Using CFD(Computational Fluid Dynamics.