• Title/Summary/Keyword: Residual water

Search Result 1,352, Processing Time 0.024 seconds

The effects of matrix aging and residual stress changes on $Avimid^{(R)}$ K3B/IM7 laminates (수지 노화와 잔류응력 변화가 $Avimid^{(R)}$ K3B/IM7 복합재 적층에 미치는 영향)

  • Kim, Hyung-Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.3 s.22
    • /
    • pp.124-130
    • /
    • 2005
  • In this paper, the effects of matrix hygrothermal aging and residual stress changes on $Avimid^{(R)}$ K3B/IM7 laminates in $80^{\circ}C$ water were studied. The factors causing the $80^{\circ}C$ water to degradation of the laminates could be the degradation of the matrix toughness, the change in residual stresses. After 500 hours fully saturated aging of the neat resin, the weight gain was 1.55% increase with the diffusion coefficient $7{\times}10^{-6}m^2/s$ and the fracture toughness was decreased about 41%. After 100 hours fully saturated aging of the $[+45/0/-45/90]_s$ K3B/IM7 laminates in $80^{\circ}C$ water, the weight gain was 0.41% increase with the diffusion coefficient $1{\times}10^{-6}m^2/s$ and the loss of the microcracking fracture toughness was 43.8% of the original toughness. To see whether the residual stress influenced the fracture toughness, two ply $[90^{\circ}/0^{\circ}]$ laminates were put in $80^{\circ}C$ water from 2 hours to 8 hours. The changes in residual stress in 8 hours are less than 3MPa. Because the 3MPa change is not sufficient to degrade the laminates, the main factor to degrade the microcracking fracture toughness was the degradation of the matrix fracture toughness.

Effect of Experimental Factors on Manganese Removal in Manganese Sand Filtration (망간모래여과공정에서 망간제거에 미치는 영향인자)

  • Kim, Berm-Soo;Yoon, Jaekyung;Ann, Hyo-Won;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.86-93
    • /
    • 2006
  • In the drinking water treatment, the aesthetic and color problem are caused by the manganese which is occurring and present in the surface, lake and ground water. The most common treatment processes for removing manganese are known for oxidation followed by filtration. In this study, the manganese sand process was used for removing manganese with river bank filtrate as a source. In the manganese sand process, the residual chlorine and pH are important factors on the continuous manganese oxidation. In addition, space velocity (SV) and alum dosage are play a role of manganese removal. Even though manganese removal increased with increasing chlorine concentration, the control of residual chlorine is actually difficult in this process As the results of tests, the residual chlorine concentration as well as manganese removal were effectively achieved at pH 7.5. The optimum attached manganese concentration on manganese sand was confirmed to 0.3mg/L by the experimental result of a typical sand converting to manganese sand.

Seasonal Monitoring of Residual Antibiotics in Soil, Water, and Sediment adjacent to a Cattle Manure Composting Facility (우분 퇴비공장 주변 농경지 및 수계의 계절별 잔류 항생물질 모니터링)

  • Lee, Sang-Soo;Kim, Sung-Chul;Yang, Jae-E;Ok, Yong-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.5
    • /
    • pp.734-740
    • /
    • 2010
  • Overuse of veterinary antibiotics threats public health and surrounding environment due to the occurrence of antibiotic resistant bacteria. The objective of this study was to evaluate the antibiotic's concentrations of tetracycline (TC), chlortetracycline (CTC), and oxytetracycline (OTC) in a tetracycline group (TCs), sulfamethazine (SMT), sulfamethoxazole (SMX), and sulfathiazole (STZ) in a sulfonamide group, lasalocid (LSL), monensin (MNS), and salinomycin (SLM) in a ionophore (IPs), and tylosin (TYL) in a macrolide (MLs) group from soil, water, and sediment samples adjacent to a cattle manure composting facility. For all samples of soil, water, and sediment, the highest concentrations were detected in TCs among the tested antibiotics because of its higher annual consumption in veterinary farms, Korea and its higher cohesiveness with divalent or trivalent cations in soil. Moreover, the concentrations of residual antibiotics in September were generally higher than in June because of heavier rainfall in June. We suggest that continual monitoring and developing guideline of antibiotics are needed to control residual antibiotics in the environment.

Design Optimization of an Ozone Contactor Using Ozone Contactor Model (OCM) Software

  • Kim, Doo-Il;Lee, Chae-Young;Joe, Woo-Hyeun;Lee, Seock-Heon
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.244-249
    • /
    • 2009
  • Designing an ozone contactor is complicated because the residual ozone, log C. parvum inactivation, and bromate formation should be optimized with fluctuating water quality. OCM software was developed to assist a plant designer or an operator to fulfill the sophisticated optimization required in the design or operation of a new or an existing plant. In this article, numerical simulations were carried out using the OCM software for the design of a new ozone contactor under diverse design factors (i.e., three pHs, three temperatures, low and high dispersion numbers, and four and ten cells with complete mixing) with kinetic parameters obtained from the sand-filter effluent of a water treatment plant treating water from the Paldang impoundment. The results of the simulation suggested that a high residual ozone concentration at low pH and low temperature would be challenging, and PFR-like hydrodynamics could lower the residual ozone concentration. The inactivation of C. parvum oocysts increased at a lower pH. A lower dispersion number and more cell division increased the inactivation efficiency. Bromate was instantaneously formed during the initial ozonation stage. The effluent concentration was much lower than the regulatory levels imposed by the USEPA because of the low bromide level in raw water.

Effect of the Residual Excess Pore Water Pressure on the Slope Stability Subjected to Earthquake Motion (잔류 과잉공극수압이 지진 하중을 받는 사면의 안정에 미치는 영향)

  • Lee, Jun-Dae;Kwon, Young-Cheul;Bae, Woo-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.107-113
    • /
    • 2006
  • Earthquake motion is one of the most significant influence factors on the slope stability. In this paper, an effective stress analysis with the elasto-plastic model was carried out to investigate the behavior of the slope stability subjected to the successive two strong earthquake motions, fore and main shock. The major influence of fore shock to the slope stability was considered as the existence of the residual excess pore water pressure. The paper presents the influence of the existence of the fore shock to slope stability using the numerical analyses. In conclusion, the excess pore pressure by the fore shock was not dissipated during the 7hrs of consolidation. By this residual excess pore water pressure, the factor of safety at the sliding face showed the minimum values, and the deformations of slope was large when compared with the case that considered the main shock only. Furthermore, the minimum of the factor of safety came out after the end of the earthquake motion.

Effects of flushing techniques on water quality at extremity with low chlorine residuals in drinking water distribution systems (수질 취약지역 및 관말에서 플러싱 적용 먹는물 수질 개선 효과)

  • Ko, Kyung-Hoon;Kweon, Ji-Hyang;Kim, In-Ja;Lim, Woo-Hyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.313-324
    • /
    • 2011
  • Several complaints from consumers on red or turbid waters were often filed at the same places although various efforts were made to improve water quality in the drinking water plant. The red water problems were occurred due to corrosion of main water pipe, especially at extremity. The low concentrations of chlorine indicating poor water quality were detected at the problematic location. To solve the poor water quality at the extremity, flushing techniques, i.e., conventional flushing, unidirectional flushing, and continuous flushing, were recently practiced. In this study, effects of conventional flushing on water qualities were examined by comparing turbidity and residual chlorine before and after flushing. In addition, more detailed analyses on water qualities at the tap water were conducted to learn a reduction pattern during flushing. Five items from geographic information system of water distribution were used to obtain a relationship with water quality, washing duration or amounts of washing water. The flushing was effective to meet the National Drinking Water Quality Standard with simple and relatively short time operation. The key operational parameter in flushing was amounts of washing water which should be estimated based on water quality of the consumer's tap water. The positive relationship between the residual chlorine and pipe length implied that detention time in the pipeline was the main cause of the complaints. More experiments on effectiveness of flushing are needed to determine reasonable strategies of flushing.

An Analytical Study on Generation of Pore-Water Pressures Induced by Flow and Waves in Seabed, and Resulting Liquefaction (흐름과 파에 의한 해저지반내 간극수압의 발생과 액상화에 관한 해석적인 연구)

  • Lee, Kwang-Ho;Kim, Dong-Wook;Kim, Do-Sam;Bae, Ki-Seong;Jeon, Jong-Hyeok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.5
    • /
    • pp.324-338
    • /
    • 2015
  • Analytical solutions for interaction between seabed and waves such as progressive wave or partial standing wave with arbitrary reflection ratio or standing wave have been developed by many researchers including Lee et al.(2014; 2015a; 2015b; 2015c; 2015d) and Yamamoto et al.(1978). They handled the pore-water pressure as oscillating pore-water pressure and residual pore-water pressure separately and discussed the seabed response on each pore-water pressure. However, based on field observations and laboratory experiments, the oscillating and residual pore-water pressures in the seabed do occur not separately but together at the same time. Therefore, the pore-water pressure should be investigated from a total pore-water pressure point of view. Thus, in this paper, the wave-induced seabed response including liquefaction depth was discussed among oscillating, residual, and total pore-water pressures' point of view according to the variation of wave, seabed, and flow conditions. From the results, in the field of flow with the same direction of progressive wave, the following seabed response has been identified; with increase of flow velocity, the dimensionless oscillating pore-water pressure increases, but the dimensionless residual pore-water pressure decreases, and consequently the dimensionless total pore-water pressure and the dimensionless liquefaction depth decrease.

Annual Groundwater System Change in Geum-gang Basin (금강 수계 지하수 시스템의 연간 물수지 변화 추정)

  • Kim, Ji-Eun;Kim, Tae-Hee
    • Economic and Environmental Geology
    • /
    • v.44 no.1
    • /
    • pp.49-57
    • /
    • 2011
  • Water budget analysis in the groundwater system was conducted in order to understand water budget distributions in the ground water system in Geum-gang watershed. The annual amounts of precipitation, runoff, evapotranspiration, dam storage change and water supply over the sub-watershed in Geum-gang watershed were evaluated the residual groundwater from 2002 to 2006, based on the water budget considering inflow and outflow. Then we are able to expect residual groundwater of each sub-basin. According to the result of study, the year 2003 and 2006 were recorded the highest and the lowest precipitation value, respectively. Average run-off percentage against precipitation was 60.44%. Annual evapotranspiration in each of years didn't show the remarkable variations but the values were high in the lower reaches of the basin. The residual waters in Geum-gang basin were determined to be 133.36 in 2002, 77.64 in 2003, -19.40 in 2004, -82.25 in 2005 and -128.07 mm in 2006. The residual water in Geum-gang basin was high in the main and up stream such as Maepo. Also the residual water showed low distributions in Nonsan and Seokhwa.

Development of techniques for evaluating residual life of water pipes based on pipe deterioration evaluation results (관로 노후도 평가결과를 이용한 상수도 관로의 잔존수명 평가 기법의 개발)

  • Park, Suwan;Kim, Kimin
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.10
    • /
    • pp.673-679
    • /
    • 2017
  • In this paper a method for estimating the 'service life' and 'residual life' of a water pipe based on the Water Pipe Network Performance Evaluation(WPNPE) results of Water Supply Technical Diagnosis was developed for efficient maintenance of water pipes. The residual life of a pipe was defined as the difference between the service life and elapsed time since installation. The service life was defined as the time when a pipe reaches the reference score for determining deteriorated pipes that was used in the WPNPE. The pipe evaluation criteria and deterioration scores used in the WPNPE for the case study area were considered as independent variables in the multiple regression model for estimating the service life and residual life of the pipes in the area. To estimate the service life for the pipes the reference scores for determining deteriorated pipes were used as the values of the variables that represent the deterioration scores in the constructed regression models. Subsequently, the statistics of the service life and residual life of the pipes in the case study area were presented and analyzed in comparison with the service life defined by the Local Public Enterprizes Act.

A Study on the Residual Mechanical Properties of Fiber Mixed Concrete with High Temperature and Load (고온 및 하중에 따른 섬유혼입 콘크리트의 잔존역학적 특성에 관한 연구)

  • Yoon, Dae-Ki;Kim, Gyu-Yong;Choe, Gyeong-Choel;Lee, Tae-Gyu;Koo, Kyung-Mo;Kim, Hong-Seop
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.119-120
    • /
    • 2011
  • Recently, the effects of high temperature and fiber content on the residual mechnical properties of high-strength concrete were experimentally investigated. In this paper, residual mechanical properties of concrete with water to cement (w/c) ratios of 55%, 42% and 32% exposed to high temperature are compared with those obtained in fiber reinforced concretes of similar characteristics with the ranging of 0,05% to 0,20% polypropylene (PP) fibers by volume of concrete, and considered factors include pre-load levels (20% and 40% of the maximum load at room temperature). Outbreak time and water contents were tested and were determined the compressive strength. In the result, it is showed that to prevent the explosive spalling of 50MPa grade concretes exposed to high temperature need more than 0.05Vol.% PP fibers. Also, the cross-sectional area of PP fiber can influence on the residual mechanical properties and the spalling tendency of fiber reinforced concrete exposed to high temperature. Especially, the external loading increases not only the residual mechanical properties of concrete but also the risk of spalling and the brittle tendency.

  • PDF