• Title/Summary/Keyword: Residual ozone

Search Result 63, Processing Time 0.033 seconds

Treatment of Microencapsulated ${\beta}$- Galactosidase with Ozone : Effect on Enzyme and Microorganism

  • Kwak, H.S.;Lee, J.B.;Ahn, J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.4
    • /
    • pp.596-601
    • /
    • 2002
  • The present study was designed to examine the effect of ozone treatment in microencapsulated ${\beta}$-galactosidase on inactivation of the enzyme and sterilization of microorganism. The efficiency was the highest as 78.4% when the ratio of polyglycerol monostearate (PGMS) was 15:1. Activities of lactase remaining outside the capsule were affected by ozone treatment. With the increase of ozone concentration and duration of ozone treatment, the activity reduced significantly. In sensory aspect, with 2% microcapsule addition, no significant difference in sweetness was found compared with a market milk during 12 d storage. Above result indicated that the additional washing process of lactase was not necessary to inactivate the residual enzyme. In a subsequent study, the vegetative cells of microorganisms were completely killed with 10 ppm for 10 min treatment by ozone. The present study provides evidence that ozone treatment can be used as an inactivation and a sterilization process. In addition, these results suggest that acceptable milk products containing lactase microcapsules made by PGMS can be prepared with ozone treatment.

A Study on the Removal Characteristics of Microcystin in the Water Treatement Plant by Ozonation (오존산화에 의한 정수장의 Microcystin제거 특성에 관한 연구)

  • 김민규;권재현;조영하;이진애;권오섭
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.74-83
    • /
    • 2003
  • Microcystin, stable compounds with circular heptapeptides, is presented inside cyanobacterial cell. So far, over 30 types have been known to exist and microcystin-LR, RR among them are the most potent toxin compound. By this reason, a strong oxidant, ozone was used in this study to remove the microcystins produced by cyanobacteria. Removal efficiency of microcystin at M water treatment plant was also evaluated. Microcystin concentration was determined by protein phosphatase inhibition assay. The results showed that dissolved microcystin in raw water detected in the range of 0.011-0.028 ㎍ Microcystin-RR equivalent/l. Above 98% of microcystin was removed through overall treatment system. Therefore, the water treatability of M treatment plant seemed to be excellent. Removal efficiency of microcystin according to unit process varied as characteristics of raw water such as DOC, UV/sub 254/ and turbidity. Removal efficiency of microcystin by ozonation was investigated in laboratory according to contact time and ozone dose. Dissolved microcystin was increased by twice fold according to ozone contact time, but increased by fifth fold according to ozone dose. So, changing of ozone dose more affected microcystin release than changing of ozone contact time. Behavior of microcystin by ozonation was similar to that of DOC, and residual ozone concentration gave influence to removal ratio of microcystin. In conclusion, single ozone treatment wasn't effective on microcystin removal in case of water containing a lot of cells. Therefore, it's more effective to use ozonation process after the removal of cyanobacterial cells in advance.

Simple tropospheric ozone retrieval from TOMS and OMI

  • Kim, Jae-Hwan;Kim, So-Myoung;Na, Sun-Mi
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.253-256
    • /
    • 2006
  • When the background tropospheric ozone column over the Pacific Ocean is subtracted from the latitudinal total ozone distribution, the results show remarkable agreement with the latitudinal stratospheric ozone distribution using the CCD. The latitudinal tropospheric ozone distribution using the CCD method, with a persistent maximum over the southern tropical Atlantic, is also seen in the latitudinal tropospheric ozone distribution using the T-P method. It suggests that the CCD method can be replaced by the simple T-P method. However, the tropical Atlantic paradox exists in the results of both the CCD and T-P methods during the northern burning season. In order to investigate this paradox, we compare the latitudinal ozone distributions using the CCD and T-P methods by using the SAGE measurements (e.g. TSA method) and the SHADOZ ozonesoundings (e.g. T-S method) assuming zonally invariant stratospheric ozone, which is the same assumption as of the CCD method. During the northern burning season, the latitudinal distributions in the tropospheric ozone derived from the T-SA and T-S methods show higher tropospheric ozone over the northern tropical Atlantic than the southern Atlantic due to a stronger gradient in stratospheric ozone relative to that from the CCD and T-P methods. This indicates that the latitudinal tropospheric ozone distribution can be changed depending on the data that is used to determine the latitudinal stratospheric ozone distribution. Therefore, there is a possibility that the north-south gradient in stratospheric ozone over the Atlantic can be a solution of the paradox.

  • PDF

A Study on the Potable Water Purification System with Pre-Ozone and Ultra Filtration Membrane of Hollow Fiber Type (전오존과 중공사형 한외여과막을 이용한 간이정수처리시스템에 관한 연구)

  • Kim, Min-Kuk;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.196-204
    • /
    • 2005
  • The objective of this study is to evaluate the possibility to apply pre-ozone and membrane system for drinking water. This system is improved in fouling control by pre-ozone system. It is composed of ultrafiltration hollow fiber type membrane and ozone reactor. The result of this study is that the flux is increased about 10.7% and decreased in TMP by the pre-ozone. Also, backwashing pressure decreased about 18%. The optimum concentration of residual ozone is 0.3~0.5 ppm. During the period, the recovery ratio of this system was turned out to be 90% as the flowrate of effluent is $67.1m^3/day$. When the TMP and backwashing pressure was $0.85kg/cm^2$ and $1.10kg/cm^2$, this system was stable without sudden fouling. Finally, the quality of effluent is satisfied the guidelines for potable water quality such as turbidity, color, E.coli, Mn, Al, Fe and so on.

Study on the Indoor Air Purification Technology by Using Nonthermal Plasma (비열 방전 플라즈마에 의한 실내 공기 청정기술 연구)

  • Jung, Jae-Seung;Lee, Heon-Gyeong;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.31-36
    • /
    • 2016
  • For the purpose of indoor air purification, air conditioner or purifier is generally used, but the long operating time induced the contamination by cumulation of bacteria in the air filter. The ozone sterilization method can be one of the effective sterilization method for this case. Ozone has not leave a secondary residual contaminants, as well as a strong sterilization power. In this study, nonthermal plasma technology is investigated as an ozone generator for the air filter sterilization. Additionally, nonthermal plasma technology is possible to obtain the generation of negative ions and electrostatic force by simply adjusting the applied voltage.

A Case Study of Characterization of AOC Formation

  • Kim, Ji-Hoon;Hwang, Hyeon-Uk;Kim, Young-Ju
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.261-267
    • /
    • 2010
  • The variation of assimilable organic carbon(AOC) concentration at each condition of ozonation was investigated using a model water and drinking water resource. AOC concentration of model raw water and drinking water resource tended to increase at low ozone dose. The maximum AOC concentration was detected when the residual ozone begin to be measured. Also, the AOC concentration increase at pH 8 compared to both pH 6 and 7 while that for pH 9 decreased rapidly. The removal characteristics of trihalomethane formation potential(THMFP) by ozonation was also investigated. Unlike the trend of AOC, the THMFP concentration never increased by ozonation but decreased even at low ozone dosage. From these results, the ozone dosage would be effective to simultaneously decrease both AOC and THMFP.

Preparations Purified Cellulose from Rice Hull (왕겨기반 고순도 셀룰로오스의 제조)

  • Lee, Young-Ju;Sung, Yong-Joo
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.3
    • /
    • pp.79-85
    • /
    • 2012
  • In this study, purified cellulose was prepared from rice husk which is one of the major agricultural residues in Korea. The various bleaching processes such as ozone bleaching, $ClO_2$ bleaching and $H_2O_2$ bleaching were applied to remove residual lignin and impurities. In order to increase the contents of ${\alpha}$-cellulose contents, the effects of acid and alkali treatments were evaluated. Although the multi stages of the bleaching processes resulted in less than 0.5 % residual lignin contents, the application of ozone leaded to the decrease in DP(degree in Polymerization) and ${\alpha}$-cellulose contents. The alkali treatment after bleaching processes resulted in pure cellulose which showed more than 98% of ${\alpha}$-cellulose contents.

Inactivation of Zooplankton Artemia sp. Using Plasma Process (플라즈마 공정을 이용한 동물성 플랑크톤 Artemia sp. 불활성화)

  • Dong-Seog Kim;Young-Seek Park
    • Journal of Environmental Science International
    • /
    • v.32 no.3
    • /
    • pp.197-204
    • /
    • 2023
  • This study aims to inactivate Artemia sp. (Zooplankton) in ballast water through the dielectric barrier discharge (DBD) plasma process. The DBD plasma process has the advantage of enabling direct electric discharge in water and utilizing chemically active species generated by the plasma reaction. The experimental conditions for plasma reaction are as follows; high voltage of 9-22 kV, plasma reaction time of 15-600 s, and air flow rate of 0.5-5.5 L/min. The results showed that the optimal experimental conditions for Artemia sp inactivation were 16 kV, 60 s, 2.5 L/min, respectively. The concentrations of total residual oxidants and ozone generated by plasma reaction increased with an increase of in voltage and reaction time, and the concentration of generated air did not increase above a certain amount.

Effect of Ozone Water on Pesticide-Residual Contents of Soybean Sprouts during Cultivation (콩나물 재배중 잔류농약 함량에 미치는 오존수 처리 효과)

  • Kim, Soon-Dong;Kim, Il-Doo;Park, Mee-Za;Lee, Yoon-Gyeong
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.277-283
    • /
    • 2000
  • This study was conducted to investigate the effect of ozone treatment on the growth and pesticide-residual contents of soybean sprouts during cultivation. Total weight and length of the soybean sprouts treated by 0.3 ppm ozone water for 30min during soaking of soybean increased 27% and 19% higher than those of control group, respectively. But 27% of root weight decreased. No major differences in growth state were observed between the treatments during soaking and watering with ozone water, and watering with ozone water. Pesticide residues in soybeans treated with carbendazim, captain, diazinon, fenthim, dichlorvos and chlorpyrifos ranged from 4.75 to 8.35 ppm. The pesticides in soybean sprouts by the treatment of soaking and watering with water for 5 days, those by 0.3 ppm ozone-water watering, and those by soaking and watering with 0.3 ppm ozone water were destroyed to $85{\sim}99$, $89{\sim}100$ and $94{\sim}100%$, respectively. The order of degradation ratio in the pesticides was captan>dichlorvos>fenthion>carbendazin>diazinon>chlorpyrifos.

  • PDF

Nano Particle Precipitation and Residual Ozone Decomposition of a Hybrid Air Cleaning System Comprising Dielectric Barrier Discharge Plasma and MnO2 Catalyst or Activated Carbon (활성탄 또는 촉매가 장착된 배리어 유전체 방전 하이브리드. 공기청정 시스템의 나노입자 및 잔류 오존 제거 특성)

  • Byeon, Jeong-Hoon;Hwang, Jung-Ho;Ji, Jun-Ho;Kang, Suk-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.524-533
    • /
    • 2003
  • DBD(Dielectric Barrier Discharge) plasma in air is well established for the production of large quantities of ozone and is more recently being applied to aftertreatment processes for HAPs(Hazardous Air Pollutants). Aim of this work is to determine design and operating parameters of a hybrid air cleaning system. DBD and ESP(Electrostatic Precipitator) are used as nano particle charger and collector, respectively. Pelletized MnO$_2$ catalyst or activated carbon is used fer ozone decomposition or adsorption material. AC voltage of 7~10 KV(rms) and 60 Hz is used as DBD plasma source. DC - 8 KV is applied to the ESP for particle collection. The overall particle collection efficiency for the hybrid system is over 85 % under 0.64 m/s face velocity. Ozone decomposition efficiency with pelletized MnO$_2$ catalyst or activated carbon packed bed is over 90 % when the face velocity is under 0.4 m/s in dry air.