• Title/Summary/Keyword: Residential treatment

Search Result 130, Processing Time 0.023 seconds

A Novel Treatment Method for the Wastes of Unsanitary Landfill at the Residential Development Site (택지개발 현장 내 비위생매립지의 매립쓰레기 처리방안 연구)

  • Son, Young-Gyu;Park, Beom-Guk;Lim, Myung-Hee;Kim, Won-Jang;Khim, Jee-Hyeong
    • Journal of Environmental Science International
    • /
    • v.17 no.2
    • /
    • pp.177-183
    • /
    • 2008
  • Characteristic of wastes in a unsanitary landfill at the residential development site in H city, Kyunggi-do was investigated for the disposal of huge amount of wastes. The total amount of wastes was estimated at 117,000 ton and construction solid wastes and municipal solid wastes were detected together. The portion of combustibles was very low and soils, concrete wastes, and pebbles were the major components in landfilled wastes. Because the site was the residential development site, the landfilled wastes should be removed immediately for the construction. Therefore the way that the unsanitary landfill was excavated and the wastes were sorted into three categories such as soils, noncombustibles and combustibles was selected as the best method. Soils and noncombustibles could be recycled and sorted combustibles could be re-landfilled in a smaller area or incinerated.

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures I: Characteristics of the Foul-Smelling Sewer Pipe in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 1: 주거지역 하수관로의 악취 발생 특성)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.621-629
    • /
    • 2007
  • This study intends to investigate the characteristics of the foul smell of sewer pipes near large apartment complexes as complaints about offensive odors have drastically increased in urban residential areas. Targeting apartments where people actually complained about foul orders, the study result revealed that components in the smell of the water-purifier tank of the target apartment were very similar to those of sewage treatment plants and night soil treatment plants. Measuring components of odors inside the management layer of tank showed that the concentration of hydrogen sulfide was 10ppm, which is approximately 160 times the safety standard of 0.06ppm; the concentration of mercaptan was 0.9ppm, which is about 220 times the safety standard of 0.004ppm. The source materials of foul odors were discharged outside through ducts, and those households living near outlets producing bad smell complain that it gets worse depending on the air pressure or wind direction and strength, and they could not even open windows. As well, these source materials were transferred by discharge pumps to public sewer pipes outside the apartment complex. While discharge pumps starts operating, they remain on the sewer pipe and then begin to spread over to roads through small openings of manholes on the road. Then, the smell offends passers-by and residents near the road, leading to a lot of complaints. The study results suggest that, among the sources of foul odors in sewer pipes of residential areas, especially those from the water-purifier tank of large apartments, hydrogen sulfide should be the main target for follow-up treatment.

A Comparative Study of University Student's Self-Esteem According to General Characteristics and Orthodontic Treatment (대학생의 일반적 특성 및 교정치료에 따른 자존감 비교연구 - 대구, 경북지역 대학생을 중심으로 -)

  • Kim, Hong-Sik;Song, Jae-Sang;Lim, Byung-Chul
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.381-390
    • /
    • 2012
  • Purpose: The goal of this study is to investigate the correlation of orthodontic treatment with self-esteem and how orthodontic treatment has an effect on university student's self-esteems by investigating and analyzing the difference in self-esteem of each general characteristic and the difference in self-esteem according to the existence or nonexistence of malocclusion and orthodontic treatment for adult university students. Methods: This study conduced a survey for 420 university students including dental related department, department of health and department of non-dental health in two universities located in Taegu, Gyeongbuk-do province from May 15, 2012 to May 30, 2012, and in 420 questionnaires of the investigated 420 target students, total 400(95.2%) questionnaires except for the questionnaires with falsely or erroneous responses were used for study analysis. Results: In the relations of general characteristic with self-esteem, for self-esteem by each gender, male student showed higher, for self-esteem by residential area, the university student residing at metropolitan area showed higher, for self-esteem by financial status, high class and middle class students in home financial status showed higher, for self-esteem by face shape, the student with triangular face shape showed higher, and in the relation of self-esteem with orthodontic treatment, the university student who is getting orthodontic treatment showed higher self-esteem statistically significantly. Conclusion: For gender, male university student, for residential area, the university student residing at metropolitan area, the high class university student in financial status, the university student with triangular face shape, and the university student who is getting orthodontic treatment showed statistically significantly higher self-esteem.

Development of an environmentally friendly precipitation treatment system utilizing open space in residential estates (주거단지의 외부공간을 활용한 친환경적 우수처리 시스템 개발)

  • Lee, Eun-Heui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.3
    • /
    • pp.55-65
    • /
    • 2001
  • The hydrological cycle system in the city is generally characterized by quick runoff, bad infiltration, low evaporation rate, and so on. It is caused by sealing greens up with pavements. Also, there are lots of contradictory environmental problems, such as inundation, the lack of underground water and dryness in the city, caused by the urban drainage system which is mostly focused on the quick draining off rainfall. In addition, the technique joining rain and sewage, which has more dangers of inundation, occupies 66% between two Korean drainage systems which consist of joining and dividing system. There has been some need to convert the present drainage system into the environmentally friendly hydrological cycle system. This is a theoretical study to examine some foreign cases and suggested applicable methods in our country, focusing on the environmentalyl friendly system of rainfall drainage. The precipitation treatment system can be made up of some possible phases choosing from premanagement, utilization, infiltration, retention, and inducement phases. Therefore, this study mostly focused on infiltration, retention, and inducement phases. It is necessary to suggest the multifunctional utilization of outdoor spaces, especially applying in new constructing and re-constructing residential estates.

  • PDF

An Experimental Study on the Edge Treatment and the Length of Noise Barrier Tunnel (방음터널의 길이와 단부처리에 관한 실험적 연구)

  • 주문기;김태훈;오양기;김하근;이원렬;조성환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1026-1031
    • /
    • 2003
  • Numbers of people living in high rise apartments are growing due to the overcrowding in urban area. Acoustic environment in those residential buildings has been seriously deteriorated by the increase of wheeled transports. Commonly used sound barriers have a limitation in controlling noise influencing higher part of a residential building. The use of noise barrier tunnels can be an alternative to supplement the defects of conventional noise barriers. But intensive measurements on noise levels at apartments vicinity of current noise barrier tunnels show that the tunnel now has a limited advantage on reducing the noise levels from arterial roads. The present work aims at providing an useful design tool In designing noise barrier tunnels for residential areas adjacent to roads. Number of field measurements, scale model measurements, and computer simulations were performed to ensure whether the prediction from scale model and computer simulation are appropriate. Result shows that the predictions from scale models and computer simulations could be valid prediction tools for designing sound barrier tunnels.

  • PDF

Land Use Characteristics in the Kyungan Watershed by Analyzing Long-Term Land Cover Data (장기적 토지피복 분석을 통한 경안천 유역의 토지이용 특성)

  • Han, Mideok;Kim, Jichan;Chung, Wookjin
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.159-166
    • /
    • 2011
  • The use of land cover was sharply changed during 1975~2007 in the Kyungan watershed $(561.12 km^2)$. The changes occurred over an area of more than $227.65 km^2$ during the overall period at changing rates of 1.04% per year for water area, 1.79% per year for residential area, 2.99% per year for bare area, 3.03% per year for wetland area, 3.04% per year for grass area, 0.87% per year for forest and 2.32% per year for agriculture area. Water, residential, bare and wetland areas increased, while grass, forest and agriculture areas decreased during the last 32 years. BOD concentrations of representative sites for each sub-watershed continuously increased until the early 2000s as residential area increased with the highest discharged load, but decreased after the mid 2000s except upper Kyungan watershed. Such decline appears to be associated with the planning of Total Maximum Daily Load management for Gwangju city and expansion of waste water treatment plant. It is necessary to control land use/cover changes of the upper watershed and to prepare appropriate watershed management system for improvement in river environment including water quality, stream flow and bio-diversity.

A Study on Development of Residential-linked Pension Insurance for Rural Living after Retirement - Decisive insuring factors and the service demand of potential consumers - (은퇴 후 농촌거주를 위한 주택연동형 연금보험 개발에 관한 기초연구 - 잠재 수요자의 보험가입조건 및 서비스 요구도 분석)

  • Hong, Hyung-Ock;Kim, Jung-In;Im, Sang-Bon
    • Journal of Families and Better Life
    • /
    • v.26 no.3
    • /
    • pp.37-52
    • /
    • 2008
  • The purpose of this study was to provide the valid data about residential-linked pension insurance development. The development was a part of national housing projects, which was an incentive for rural living of retired people, in order to relieve residential issues of elderly and revitalize rural communities by residents moving from cities. The insuring intent, decisive insuring factors and the residential service demand degree of people preparing retirement were analyzed. Data was collected in October, 2007. 364 Sample Subjects lived in Seoul Metropolitan area. Firstly, more than 90% of respondents had intention to purchase a residential-linked pension insurance and about 50% of them necessarily desired receiving premium for moving in. This indicated that it could be developed as an insurance which helped to meet housing expenses by housing-linked system, and in the mean time, it met the original purpose of pension insurance as the pension benefit could be guaranteed for all the insurance subscribers. Secondly, the respondents, whose income and private assets were higher, were able to pay more for insurance compared to average. Therefore, It was necessary to regulate monthly insurance bill and the payment period according to asset states of insurance subscribers after establishing certain amount of total insurance payment. Thirdly, by and large, it indicated the tendency that the less they prepare for older age the later they wanted to move into the pension insurance residence. It was inferred that in the case of insufficient preparation for older age, people preferred preparing behind time by postponing move in to moving in early to enjoy retired life, due to uncertainties. lastly, the respondents understood the significance of health, medical treatment and emergency management service and these two services were preferred as essential provided services. Because of the necessity of developing residential-linked pension insurance was found to be positive, further research to find the real cost, directives for operation and institutional support for this type of pension insurance might be needed.

Decomposition of Organic Matters by Ozonation in Advanced Water Treatment Process (고도정수처리공정에서 오존의 유기물 분해능)

  • Yoon Taekyung;Lee Gangchoon;Noh Byeongjil
    • Journal of Environmental Science International
    • /
    • v.14 no.3
    • /
    • pp.327-333
    • /
    • 2005
  • The performance of ozone contactor in ozone-BAC advanced water treatment process was evaluated by the degree of decomposition of organic matters. The degree was measured by the analyses of $UV_{254}$ absorbance and the concentrations of DOC and BDOC for the sand filtered water and the ozone treated water, respectively. In addition, the ozone concentration in the contactor, required for the maximum BDOC concentration, was selected as the optimum concentration, and the appropriate residential time of ozone treated water in a reservoir was recommended based on the residual ozone concentration in the treated water. The following results were obtained from the pilot scale experiments. By ozonation $UV_{254}$ absorbance was decreased, and BDOC concentration was increased. The change of DOC concentration by ozonation was negligible, but the excess input of ozone resulted in the removal of the small amount of BDOC by complete oxidation. The optimum ozone concentration was 0.58mg $O_3/mg$ DOC. In order to remove residual ozone, 20minutes of the residential time were enough after ozonation.

A study on stormwater fee imposition for sustainable rainwater management (지속가능한 빗물관리를 위한 강우유출수 부담금 도입방안 검토)

  • Kim, Gil-Bok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.103-110
    • /
    • 2019
  • Management of stormwater runoff is considered a nationwide challenge. To deal with this challenge, many researches have been conducted to study initial stage of stormwater fee imposition. The objective of this study was to recommend a framework for stormwater fee imposition not only for funding the stormwater management programs but also for encouraging people to decrease impervious area. This study focused on, regulations, financial resources and international cases related to stormwater runoff management. Polluter pays principle, which is generally recognized environmental policy principle is regarded the basis of stormwater fee imposition. Three components suggested for the stormwater rate structure are 1) stormwater utility revenue requirement, 2) billable equivalent stormwater unit, 3) system unit cost. The key point of stormwater rate structure is the "Equivalent Residential Unit(ERU)". The concept of an ERU is one residential area with a runoff coefficient. The runoff coefficient is that portion of rainfall that becomes runoff rather than infiltrating into the ground. In addition to this, this study took into account the observed data simulation for the separation of stormwater treatment expenditure from the comprehensive wastewater treatment cost.

Trace Metals of Ambient TSP in Daegu Area (대구지역 총 부유분진중 중금속)

  • 이찬형
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.67-73
    • /
    • 2003
  • This study was carried out to characterize the behavior and sources of particulate trace metal in Daegu city. TSP (Total Suspended Particulate matter) was collected by filters on High Volume Air Sampler from the four areal (reference, residential, commercial, industrial area). The moult were analyzed by AAS after preliminary treatment. The average centration trend of trace metals contained in TSP was shown as follows : Fe > Cu > Pb > Mn > Ni > Cr > Cd. The trace metals showed the highest concentration in the industrial area. This study showed the seasonal variation of trace metals. Fe and Mn showed high concentration in spring, whereas Cr, Ni, Cd and Pb showed high concentration in winter. Also this study showed the regional variation of trace metals. The order of the average concentration of trace metals was : industrial > commercial > residential > reference area. Using Mn as a reference element, the enrichment factor analysis were used for identifying the trace element contributors. The enrichment factors of Cr, Fe < 10 were considered to have a significant dust and soil source and termed nonenriched. Pb, Cd, Cu >>10 were enriched and had a significant fraction which was contributed by anthropogenic sources.