• Title/Summary/Keyword: Residential building

Search Result 1,190, Processing Time 0.032 seconds

Waterproofing and Root Barrier Construction Design for Artificial Green Roof System of Residential Apartment Underground Parking Lots (공동주택 지하주차장 상부 인공지반녹화층 방수 및 방근 설계 방안)

  • Lee, Jung-Hun;Kim, Bum-Soo;Song, Je-Young;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.337-338
    • /
    • 2018
  • In recent years, residential apartment building parking lots are built in underground spaces, and with conjunction to improve the environment of the urban area, artificial greeen roof systems are installed on the upper slabs. However, early plant growth are resulting in root penetration into concrete cracks and in turn into the waterproofing membranes, leading to degradation and damaging of the waterproofing system and structural durability. This issue highlights a problem of conventional maintenance system of concrete structures, and proposals for amendments follow. In this study, a waterproofing and root barrier construction design for the upper slabs of residential building underground parking lots is proposed, and motioned to be added into future construction specifications.

  • PDF

Haut - A 21-storey Tall Timber Residential Building

  • Verhaegh, Rob;Vola, Mathew;de Jong, Jorn
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.3
    • /
    • pp.213-220
    • /
    • 2020
  • This paper reflects on the structural design of Haut; a 21-storey high-end residential development in Amsterdam, the Netherlands. Construction started in 2019 and is in progress at the time of writing. Upon completion in 2021, Haut will be the first residential building in the Netherlands to achieve a 'BREEAM-outstanding' classification. The building will reach a height of 73 m, making it the highest timber structure in the Netherlands. It contains some 14.500 ㎡ of predominantly residential functions. It features a hybrid concrete-timber stability system and concrete-timber floor panels. This paper describes the concepts behind the structural design for Haut and will touch upon the main challenges that have arisen from the specific combination of characteristics of the project. The paper describes the design of the stability system and -floor system, the analysis of differential movements between concrete and timber structures and wind vibrations. The paper aims to show how the design team has met these specific challenges by implementing a holistic design approach and integrating market knowledge at an early stage of the design.

Residential Quarter Organization and Housing Spatial Form of Fishing Village in Jeonjang-po, Imja-do Island (임자도 전장포마을의 공간구조와 주거형태에 관한 연구)

  • Park, Chung-Shin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.3
    • /
    • pp.9-16
    • /
    • 2013
  • This paper aims to clarify the residential quarter organization and housing spatial form of fishing village in Jeonjang-po, Imja-do Island. The results are as follows. First, the place of residence in Jeonjang-po was located in the place having the south and the north seaside, and the road system was presented by form to connect the north and south. Second, the alley of these north and south direction has a dynamic scenery, but the alley of east-west courses has a horizontal scenery. Third, it is a characteristic that there is very more plottage than the building area of the residential quarters. The reason that plottage has a big is because inner court in the residential quarters are used as places such as the fishery works and the vegetable gardens. Finally, the fishing village house in Jeonjang-po is 4-bay type building is typical type when seeing from the front, and is to have entrance hall at the front of building.

An Analysis on the Effect of Environmental-Friendly Planning Elements on Residential satisfaction Level of the High-Rise Residential Complex (친환경 계획요소가 초고층 복합주거 거주 만족도에 미치는 영향요인 분석)

  • Hwang, Jung-Man;Lee, Joo-Hyung
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.438-450
    • /
    • 2014
  • The statistical analyzing of environmental-friendly planning elements is getting important because it is getting concerned with the change of residential types and environmental friendly housing. However, in terms of the high-rise residential complex, paper about green building rating system and research about residential satisfaction to residents are lack. Therefore, this paper is analyzing of impotentness and satisfaction about housing subdivision, inside of building, facility, and maintenance. In addition, residential satisfaction(satisfaction, loyalty, preference) and impact relationship of environmental-friendly planning elements are analyzed by PLS structural equation. To sum up, first, improving of green building rating system in housing subdivision is impacted on loyalty if satisfaction was fulfilled. Second, increasing of environmental-friendly planning elements in inside of building is impacted on loyalty if both satisfaction and preference were fulfilled. Third, providing of green building rating system in facility and maintenance is analyzed as preference, but satisfaction hypotheses is not valued.

A Study on the Adequacy Evaluation of Criteria of Occupant Load Factor in Residential Buildings (주거용 건축물의 재실자밀도 기준 적정성 평가에 관한 연구)

  • Seo, Dong-Goo;Hwang, Eun-Kyoung
    • Journal of the Korean housing association
    • /
    • v.27 no.6
    • /
    • pp.145-153
    • /
    • 2016
  • The purpose of this study is to grasp the effectiveness of evacuation safety design by verifying the appropriateness of the standard of occupant load factor for residential buildings. To this end, the definition and current standard of occupant load factor for residential buildings were analyzed, and the problems of the current standard were clarified by interviewing professionals. In addition, changes in occupant load factor were examined by year based on statistical research, and evaluation on the current standard $18.6m^2/pers.$ was performed. As for evaluation methods, the need of redesigning of evacuation capacity was investigated by using evacuation simulation. As a result of the analysis, the most serious problem was clarification of the applicable standard for residential officetel, where the average occupant load factor was $26.1m^2/pers.$, which was not appropriate. However, as a result of evaluation on evacuation capacity, although there was no difference between statistical research results and the current standard in terms of evacuation capacity, when the standard for business facilities was applied to officetel, evacuation time doubled. Thus, this study suggests that when the current standard is applied to residential officetel, it is necessary to separate between residential use and business use.

A Study on the Characteristics of Space Utilization after converting of Residential District in a New Development Area - Focused on Dunsan of Daejeon City - (신개발지 일반주거지역의 용도전환시 공간변용 특성에 관한 연구 - 대전 둔산 신시가지를 중심으로 -)

  • Park, Jung-A;Kang, In-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.123-130
    • /
    • 2010
  • The purpose of this study is to find the characteristics of space utilization and the problems that follows after converting in a new developmental residential area. This study used the content-analysis method and analysis was made on the floor plans for 95 different conversion cases. Above all, 190 unit plans (the unit plans for conversion before and after) were analyzed. The results of this study were as follows; 1) There were 8 types of conversion according to such usages as residential, commercial and residential-commercial buildings. 2) In the case of conversions, from residential to commercial, there was a tendency each floor was integrated to exclusive use for commercial or commercial with small portions of residential usage. And in the case of conversions from commercial to residential, there was a tendency that all space of each floor were changed to exclusive usages for residential purposes. 3) In case of usage conversion from commercial to residential, there were constraints for balcony installation, because of its original lot-structure and building equipments. Also, when the basement was converted for residential purpose, there was no possibility for an extra lighting or ways to ventilate the area.

A Study on the Korean-Chinese Residential Spaces of Wu-lin Village in Jiao-he, China (중국 오림향 조선족 주거공간에 대한 연구)

  • Jung, Yun-Sang;Lin, Jin-Hua
    • Journal of architectural history
    • /
    • v.24 no.2
    • /
    • pp.35-44
    • /
    • 2015
  • The purpose of this study is its residential spaces through the analysis of exterior space and interior space at Wu-lin Village(烏林屯) in Jiao-he, China. The method of this study is to search for documentation, interview, residents, make a survey of these villages about immigration history, surroundings, topographical keynotes, administration system, residential number, residential style, site composition, etc. The residents moved from Yen-bien and Jiao-he in China etc. The ancestor moved from North of Gyeong-Sang Province in South of Korea, North of Ham-Gyeong Province in North of Korea etc. The main road divides the village into two parts: the north quarter, Wu-lin Village, typified by the Chinese house, and the south quarter, You-Yi Village(友誼村), typified by the Korean-Chinese house. The houses is compose of main building and an accessory building. The main building looking south. The vegetable garden is around main buildings. The main building is compose of an On-dol room(a hot-floored room) and a kitchen, a corridor etc.

Window-to-Wall-Ratio for Energy Reduction in Early Design Stage of Residential Building

  • Lee, Myung Sik
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • In Korea, it is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to assess the optimal window-to-wall ratio of multi-rise residential units in the early design phase in Korea. The study analyzed the variation of annual heating and cooling energy load in two apartment prototype units located in Seoul city using different WWRs. The analysis was conducted using Autodesk Ecotect Analysis 2011 tool. The study found for total annual building load reductions WWR on the south and north face should be studied independently based on the room function. It also found reducing the WWR for bedrooms and windows on the northern façade resulted in reduced total annual building load.

A Study on the Fire Safety Design Methods of Opening in High-rise Building (초고층고층 건축물의 개구부에 대한 화재안전 설계방법 조사)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Lee, Byeong-Heun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.8-9
    • /
    • 2018
  • In recent years, the fire risk in the aged housing facilities in high-rise building has been closing up due to the fire in the Grenfell Tower. In the case of these high-rise residential facilities, fire cases of residential facilities such as Uijeongbu Apartment Fire The fire hazard has been reexamined mainly. Especially, the fire of these residential facilities is very closely related to the window, so measures are needed. On the other hand, in Korea, there is almost no fire safety measures against these openings. Therefore, this study suggests improvement measures by comparison with advanced countries based on fire safety measures for domestic windows.

  • PDF

Occupant Characteristics Analysis based on Integrative IEQ Weighting Factor in Residential Buildings - Based on Occupant Survey of Residential Building in Chungbuk Province (주거건물에서의 통합 실내환경평가 가중치 분석을 통한 거주자 특성분석 - 충북지역 주거건물 거주자 설문조사를 바탕으로)

  • Yoon, Sung-Hoon;Yun, Hee-Jin
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Purpose: The objective of this research is to investigate and analyze the relationship between physical residential conditions and occupants' responses in apartment buildings by POE(Post-Occupancy Evaluation). The analysis results from this research will help to identify the indoor residential problems and find design solutions for improving overall residential indoor residential environment. Method: The occupant survey was conducted at four different apartment complex area at Cheongju City, Chungbuk Province, Korea. Combination of unbalanced indoor environmental conditions in residential building had difference of occupants' responses according to occupants' characteristics, such as gender, age, and so on. The survey collected data regarding the occupants' EQ(Environmental Quality) priorities to determine the weight of each environmental-quality factor (lighting, acoustic, thermal and indoor air quality). A paired comparison method was used to determine the weight by comparing the relative importance of the two factors based on occupant's survey response. Result: The output from this research is useful to understand the residential environment, occupants' satisfaction, preference, and identifies the current residential problems and finds an architectural solution in apartment buildings.