• Title/Summary/Keyword: Residential architecture

Search Result 940, Processing Time 0.025 seconds

A study on the Energy resource in School Buildings with the Changes of Educational Facilities Standard (교육 시설기준 변화에 따른 학교건축물의 에너지원 변화에 관한 연구)

  • Kim, Tae-Woo;Lee, Kang-Guk;Hong, Won-Hwa
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • Since the Korean War, Korea has experienced modernization. The population increase by baby booming has asked for more space for educational facilities. In such a situation, the purpose of educational facilities was to accommodate continuously increasing students, rather than seeking for quantitative demands. In addition, in accordance with social changes, educational shifts were required. After the revision of the seventh national curriculum in education in 1997, the school buildings became varied. The design of buildings in accordance with educational curriculum has been improved, but still lack of forming comfortable environment and considering energy efficiency in school buildings. For the improvement of educational environments, educational media such as TV and computers have been provided, and energy systems, including heating and cooling systems, has been continuously increased. As a result, it appeared that energy use in school buildings and facilities has been steadily increased and that the structure of energy consumption has been also changed, especially with regard to electricity use. Living in the 21st century, human beings face global environmental issues, such as global warming, geographical climate changes, and ozone destruction that are the consequences of fossil energy use. Therefore, even in industrial areas, considering a counterplan for low energy use is being paid attention. Starting with Kyoto Protocol in 1992, people try to decrease carbon dioxide and to develop alternative energies (i.e. natural energy); for example, solar energy, wind force, terrestrial heat, and water power. Advanced countries already set up a criterion for $CO_2$ decrease ranging from office buildings to residential houses and also propose alternatives for the $CO_2$ decrease. However, there is no such a plan for low energy use and $CO_2$ decrease in school facilities, and any research on the actual conditions was not accomplished. Thus, this study examines energy demand in classrooms that take up a large portion of energy demand in school building structure.

Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations (오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획)

  • Kim, Jiyoeng;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment (기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구)

  • Kim, Seohoon;Kim, Jonghun;Yoo, Seunghwan;Jeong, Hakgeun;Song, Kyoodong
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

A Study on Correlations of the Gap Ratio of Apartment Houses Arrangement and the Wind Field (공동주택단지배치의 간극비와 바람장의 상관관계에 관한 연구)

  • Moon, Chul-Seong;Oh, Se-Gyu;Cho, Sung-Woo
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.75-82
    • /
    • 2011
  • In Korea, the ratio of population in urban areas used to be only 50.1% in 1970, but with the value risen to 90.8% in 2009, urbanization is going on rapidly. Urbanization, which occurs by the rampantly planted buildings, has become major source of raising building density, changing wind direction and reducing wind amount, and such reductions are affecting even inside the building. In each year, among the total energy consumption in Korea, residential portion takes up significant ratio, and specifically the ratio of apartment house is shown to be highest. In order to solve such problem, many studies are being conducted for the improvement of natural ventilation performance. The natural ventilation performance of apartment house are significantly determined by the characteristics of external and internal structure, but in macroscopic perspective, the performance is established fundamentally by the layout characteristics of the main building of the apartment house in preparation for wind conditions. So far researches on raising the thermal comfort through elevation of ventilation performance have been conducted actively, but many of them propose only theoretical concepts deduced through wind path analysis, and do not include any indicator to measure ventilation performance simply only with area data from layout planning stage. Therefore, in this study, gap ratio a wind field measuring indicator was developed, and after the ventilation characteristics by layout types and main building uniformity were identified, the scope of gap ratio efficient for ventilation and that of uniformity were clarified, followed by verification through simulation.

Busan building height regulations for the management of mountain landscape: focused on the skyline of Hwangreung Mountain (부산시 산지경관 관리를 위한 건축물 높이 규제 방법에 관한 연구: 황령산 산림스카이라인을 중심으로)

  • Han, Sung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.970-978
    • /
    • 2011
  • The high-rise buildings have been indiscriminately located in the good natural landscape in Busan. They destroy the mountain skyline that is the key role of urban landscape and lower the index of greenness. Busan need the efficient management methods of the mountain skyline to improve the quality of urban life, the amenity of urban landscape, and the index of greenness. This study is to propose the method of building height restriction both through the GIS bases multiple sight surface analysis and through the analysis of the floor area ratio to make up for the weakness of single sight surface analysis has been used as a means of building height restriction. It studies the residential district with Hwangreung Mountain in the background at Deeyeon-don, Nam-gu, Busan. It achieves both objectivity and time efficiency by multiple sight surface analysis. Reflecting the result of this simulation at strategic viewpoints, it enables landscape planning to be comprehensive. Lastly it suggests building height regulation for protecting the mountain skyline which responds to the local conditions.

Evaluation on the Vibration Performance for Void-deck Slab Combined with Deck Plate and Polystyrene Void Foam (데크플레이트와 경량성형재가 결합된 중공슬래브의 진동성능에 대한 실물실험 평가)

  • Cho, Seung-Ho;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.86-92
    • /
    • 2017
  • The possibility to development of floor vibration problem is larger in case of long span structure under service loads. Therefore, to improve the vibration performance of the floor, increasing of its thickness is a common method. But, increasing of thickness can lead to increase of slab self weight and reduce the effectiveness of the building. For this reason, attention for voided slab which reduces the self-weight is increasing. Hence, voided deck slab combined with deck plate and polystyrene void foam which has buoyancy prevention capacity and much developed construct ability has bee developed. By using the developed voided slab, vibration performance of a mock-up building structure has been investigated in the current study. The results according to analysis showed that they can be implemented in living and bedroom which are considered as 1st grade on the basis of "Residential Evaluation Guidelines for Vibration of Buildings" by the Architectural Institute of Japan.

Establishment and Application of Computer-Assisted Environmental Information System for Land Use Zoning and Environmental Analysis of Natural Park (자연공원의 환경분석 및 용도지역설정을 위한 전산환경정보체계의 수립과 적용)

  • Lee, Myung-Woo
    • Journal of Environmental Impact Assessment
    • /
    • v.2 no.1
    • /
    • pp.39-55
    • /
    • 1993
  • The importance of urban and regional natural park increases because of the needs for preserving the natural resources and providing with natural recreation space in nature. This planning of natural park management should be established based on the research of the various natural resources in the park. But for the lack of effective data synthesizing methods and concepts, only some restricted factors for zoning plan are considered even though GIS computer system for large complex simulation is used. Therefore, in this study three ecological zoning models such as Basic Factor Model (BFM), Visual Landscape Model (VLM) and Comprehensive Ecological Model (CEM) are proposed and applied to Byounsan Peninsula Nature Park(BPNP) for comparison with the current natural park zoning. The BFM has three components -elevation, slope and vegetation. The VLM has applied with six components -elevation, slope, vegetation, road type, and the visual distance. Finally the CEM's modelling factors have included all of BFM, VLM components are added with the land use type, nature and historic resource factors. The zoning concept of BPNP was based on "Minimization" focused on the specific factors. But introduced modelling concept is "Optimization" based on the total ecological environment. So the result of the modelling has larger area for preservation and development zoning compared with the current zoning whose characteristics are ambiguous which allows the environmental destruction. The future study issues will be the determination of the weighting factor, component reconsideration based on the ground truth data and the agriculture residential area zoning.

  • PDF

A study on the Residential Satisfaction of Environmental Condition for Housing Complexes located in Coastal Areas (연안역에 입지하는 주거단지 생활자의 거주환경 만족도에 관한 연구)

  • Lee, Myung-Kwon
    • Journal of Navigation and Port Research
    • /
    • v.32 no.6
    • /
    • pp.505-513
    • /
    • 2008
  • Regarding the developmental plans for the coastal areas and marine architectures, this study deal with the overall planning of apartment complexes in waterfront areas, focusing upon the analysis of their comfort and convenience factors from the perspective of the potential residence. It also analysis the intra-complex comfort and satisfaction conditions in terms of their floor-by-floor, directional. and location factors. The results of the study are as follows: 1) The order of respondents' preference on directional factor has been found to be: South > Southeast > Southwest > East > others. 2) 67% of the people surveyed on scenery responded that outward view is considered more significant than the directional factor. 3) A comprehensive analysis of floor zone-specific view preference shared that there were only minor differences among quay wall, arc, and river-seashore types. The impact of the characteristics of the marine environments turned out to be a greater point of consideration; showing that the other of floor-preference is: high-level > ultra-high level > middle level > low level.

Experimental Investigation on the Optimal Design of Water Tank for Domestic Hot Water Supply using PEMFC Co-generation System (가정용 고분자 전해질 연료전지 열병합 발전시스템의 급탕 적용을 위한 온수 저장조의 최적 설계에 관한 실험적 연구)

  • Hwang, Yu-Jin;Ahn, Young-Chull;Cheong, Seong-Ir;Jin, Keun-Ho;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.394-399
    • /
    • 2008
  • There are many attempts to use a fuel cell system as a residential power generation system. The purpose of this study is to investigate the optimal design of a water tank for a hot water system when the fuel cell co-generation system is combined with a domestic hot water supply system. The demands of hot water supply per month per home are investigated in Busan for a year. It showed somewhat large differences between the actual demand and the designed demand of hot water, but the actual capacity of hourly averaged hot water demands is analyzed as $60{\ell}/h$ in this study based on the actual demand. The experiments are performed in the various inlet and outlet locations of nozzles, and the hot water consumption rates. The experimental results are showed that the optimal capacity of the water tank is $200{\ell}$ when the thermal efficiency, the storing capacity of hot water and the space for installation are considered.

Changes of Rural Landscape in the lifted Green-belt Area Using Resident Employed Photography(REP) (거주민 참여 사진촬영 방법(REP)를 활용한 개발제한구역 해제에 따른 근교 농촌 경관변화 분석)

  • Yun, Seung-Yong;Son, Yong-Hoon
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.4
    • /
    • pp.15-25
    • /
    • 2018
  • This study was designed to understand the change of rural landscape and to consider problems followed by development restrictions lifted for Neobiul Village in Ansan City, Korea. Physical landscape changes were comprehended by a field study and interview with local residents, and the residents' perception regarding the landscape changes were analyzed with the REP investigation method. The results can be summarized into the following three points: First, due to the lift of development restrictions and the deregulation of land use, the number of factories and warehouses for rent increased, which became a new source of income for the village. Second, the residents' complaints increased due to the increased traffic volume and waste from a sudden influx of factories and warehouses, which could not be handled by a small farming village. Third, a mix of landscape combining both city and farming village was formed due to the influx of external capital and the need of rental income, although the residents rather wanted Neobiul Village to become a residential village than a factory location. Furthermore, even in the farmlands near the village where development restrictions have not been lifted, the level of dependence on the farming industry has decreased as a consequence of the increase in farmland rent and weekend farms. This paper confirmed that the change of rural landscape followed by lifted development restrictions affects the everyday life of residents living in Neobiul Village. This study has significant implications in that it suggests a case showing the effects of national policies such as lifting development restrictions for rural villages in suburban areas.