• Title/Summary/Keyword: Residential Complex

Search Result 484, Processing Time 0.028 seconds

The effects of topography on local wind-induced pressures of a medium-rise building

  • Hitchcock, P.A.;Kwok, K.C.S.;Wong, K.S.;Shum, K.M.
    • Wind and Structures
    • /
    • v.13 no.5
    • /
    • pp.433-449
    • /
    • 2010
  • Wind tunnel model tests were conducted for a residential apartment block located within the complex terrain of The Hong Kong University of Science and Technology (HKUST). The test building is typical of medium-rise residential buildings in Hong Kong. The model study was conducted using modelling techniques and assumptions that are commonly used to predict design wind loads and pressures for buildings sited in regions of significant topography. Results for the building model with and without the surrounding topography were compared to investigate the effects of far-field and near-field topography on wind characteristics at the test building site and wind-induced external pressure coefficients at key locations on the building facade. The study also compared the wind tunnel test results to topographic multipliers and external pressure coefficients determined from nine international design standards. Differences between the external pressure coefficients stipulated in the various standards will be exacerbated when they are combined with the respective topographic multipliers.

Structural Design of High-Rise Concrete Condominium with Wall Dampers for Vibration Control

  • Tsushi, Takumi;Ogura, Fumitaka;Uekusa, Masahiro;Kake, Satoshi;Tsuchihashi, Toru;Yasuda, Masaharu;Furuta, Takuya
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.201-209
    • /
    • 2019
  • This paper presents a structural design of the "(Tentative Name) Toranomon Hills Residential Tower" which is currently under construction in Tokyo. The building is a reinforced concrete high-rise residential complex building with 54 stories above ground, 4 basement levels, and a building height of about 220 m. It is a requirement to provide the highest grade of residence in Japan, and in terms of the structural design, it is required to provide wide and comfortable spaces with high seismic performance. These requirements are satisfied by providing a total of 774 vibration control walls of two types. Also, to further improve the structural performance, steel fibers at the rate of 1.0vol% are provided in the ultra-high strength concrete used in the column members.

COST ANALYSIS OF STRUCTURAL PLAN FOR REDUCING FRAMEWORK CONSTRUCTION DURATION OF REINFORCED CONCRETE RESIDENTIAL BUILDINGS

  • Seon-Woo Joo;Moonseo Park;Hyun-Soo Lee
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.493-498
    • /
    • 2009
  • Recently, the number of complex construction projects, such as high-density development and long-span mega structure construction, has been increasing globally. Therefore, the construction duration has become an even more important factor for success. Nevertheless, in domestic residential construction projects, it usually takes more time than twice as much as North American cases. The long construction duration causes a number of problems, for example growth of financial costs, fall in productivity, and weakness of competitiveness. If the framework construction duration can be shortened to 3 ~ 4 days, then it is also expected to complete the finish work of building in shorter duration, be led to reduce the entire construction duration, and eventually to save a great deal of indirect costs. For shortening the construction duration, previous researches pointed out that the development of simplified plan design should precedes. But, in reality, lack of experience of new design and innovative techniques tends to be the obstacle to wide adoption of the simplified plan design in construction fields. In this paper, a simplified structural plan design is proposed, and the construction cost is quantitatively compared between when traditional construction technique is applied to the traditional plan and when the duration-shortening key technique is applied to the developed plan.

  • PDF

Distribution of Airborne Hexavalent Chromium Concentrations in Large Industrial Complexes in Korea

  • Kang, Byung-Wook;Lee, Hak-Sung;Kim, Jong-Ho;Hong, Ji-Hyung;Kim, Rok-Ho;Seo, Young-Kyo;Han, Jin-Seok;Baek, Kyung-Min;Kim, Min-Ji;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.208-216
    • /
    • 2016
  • This paper reports the results of a field evaluation which used sampling and analytical methods to determine the levels of airborne hexavalent chromium Cr(VI) in major industrial complexes in Korea over a seven year period (2007-2013). Cr(VI) concentrations were determined using cellulose filter sampling and ion chromatography analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control (QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of Cr(VI) for the nine industrial complexes in Korea were in the range of 0.09 to $1.40ng/m^3$, which is similar to of the concentrations in other industrial areas around the world. The impacts of Cr(VI) emissions from industrial areas on Cr(VI) concentrations in neighboring-residential areas were considerably low, and the dispersion of Cr(VI) from industrial areas to residential areas was estimated to be 'not-significant'. Cr(VI) levels were not affected by seasonal variation, which suggests that chromium was emitted continuously from the industrial sources throughout the year. The concentration of Cr(VI) measured accounted for 0.7 to 9.4 percent of the total chromium level, which is a low percentage compared to those in other urban areas around the world. This is the first report in an international journal of a field study conducted in Korea to determine the concentration of Cr(VI) in the ambient air of industrial and residential areas.

Genotoxic Effect of Air-borne Particulate Matter in Residential Area of Seoul City (서울시내 주거지역 미세먼지의 유전독성 영향)

  • Oh Seung Min;Sung Hye Kyoung;Kim Eun Sil;Kim Jong Geuk;Ryu Byung Taek;Chung Kyu Hyuck
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.4 s.51
    • /
    • pp.365-374
    • /
    • 2005
  • Ambient air particulate matters are classified into two distinct modes in sire distribution, namely the coarse and fine particles. Correlation between high particulate concentration and adverse effect on human populations has long been recognized. However, the toxicology of these adverse efforts has not been clarified. We investigated the genotoxic effect of PM 2.5 collected from urban area in Seoul by comet assay (A549 cells), CBMN assay (CHO-K1 cells) and EROD-microbioassay (H4IIE cells). Results from in vitro micronucleus assay and comet assay showed that PM 2.5 samples collected from traffic area, residential area and indoor air induced chromosomal damage and DNA breakage in a non-cytotoxic dose. The complex mixture effect of these PM 2.5 extracts was quantified by EROD-microbioassay in terms of its bio-TEQ (biologiral -TCDD equivalent concentration) which was 70.87$\pm$28.07, 93.55$\pm$21.80 and 14.31 $\pm$ 1.10 ng/g-PM 2.5 in traffic area, residental area and indoor air samples, respectively. Conclusively, we suggested that PM 2.5 collected from traffic area and residential area contains CYPIA inducer and genotoxic materials.

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures I: Characteristics of the Foul-Smelling Sewer Pipe in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 1: 주거지역 하수관로의 악취 발생 특성)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.621-629
    • /
    • 2007
  • This study intends to investigate the characteristics of the foul smell of sewer pipes near large apartment complexes as complaints about offensive odors have drastically increased in urban residential areas. Targeting apartments where people actually complained about foul orders, the study result revealed that components in the smell of the water-purifier tank of the target apartment were very similar to those of sewage treatment plants and night soil treatment plants. Measuring components of odors inside the management layer of tank showed that the concentration of hydrogen sulfide was 10ppm, which is approximately 160 times the safety standard of 0.06ppm; the concentration of mercaptan was 0.9ppm, which is about 220 times the safety standard of 0.004ppm. The source materials of foul odors were discharged outside through ducts, and those households living near outlets producing bad smell complain that it gets worse depending on the air pressure or wind direction and strength, and they could not even open windows. As well, these source materials were transferred by discharge pumps to public sewer pipes outside the apartment complex. While discharge pumps starts operating, they remain on the sewer pipe and then begin to spread over to roads through small openings of manholes on the road. Then, the smell offends passers-by and residents near the road, leading to a lot of complaints. The study results suggest that, among the sources of foul odors in sewer pipes of residential areas, especially those from the water-purifier tank of large apartments, hydrogen sulfide should be the main target for follow-up treatment.

A Study on Assimilation and Transplantation of Public Housing at the Tiong Bahru Estate in Singapore from the 1930s to the 1950s (1930년대에서 1950년대까지 싱가포르 티옹 바루 단지에서 공공주택의 동화와 이식에 관한 연구)

  • Woo, Don-Son;Tak, Chung Seok
    • Journal of architectural history
    • /
    • v.23 no.6
    • /
    • pp.27-37
    • /
    • 2014
  • Early 20th century Singapore was faced with the problem of overcrowding. The attendant problems of a rapid increase in population density, namely the lack of proper housing and sanitation, resulted in the issue of an appropriate residential environment emerging as an important task in urban planning. It was necessary to construct housing estates in order to solve this issue. At that time, the British colonial government attempted to transplant modern technology into the construction process of a residential complex system. However, Singapore's climate and traditional lifestyle made it impossible to apply the British modern system in a straightforward manner, and in the process, a number of transformations emerged. With a specific focus on the Tiong Bahru estate, one of Singapore's representative public housing projects, from the 1930s through the 1950s, this study intends to look at the way in which such residential estates were assimilated into local surroundings, and the effect of the transplantation of British concepts of modern housing theory. Therefore, the study is divided into an examination of the estate both before and after the turning point of World War II. This study confirms that the difference between the pre-war and post-war planning strategies for the Tiong Bahru estate were made according to the concept of 'open space.'

Influences of the Residential Environment on the Apartment Remodeling: Involving the Expansion of Households and Dwelling Area

  • Lee, Ji-Eun;Yoon, Young-Ho
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.259-268
    • /
    • 2011
  • Space extension and the increase of the number of households are helpful to raise business value of the remodeling through the renovation of apartment houses that is required by residents of new cities and large-scaled apartment. However, in the case of accepting this demand, it could have a bad influence on the landscape of a complex in terms of the structure of apartment houses and the safety of construction and urban planning, and a problem occurs in the aspect of fairness for reconstruction. For the study, the current status related to the remodeling system through laws, related articles since 2000 and research data was analyzed. In addition, the individual quantitative analysis was conducted in the four aspects to judge whether households expansion for remodeling is plausible:1) Statistical data to comprehend the changes of population and social structure 2) Survey data of floor space index and the building-to-land ratio of new cities at the intial stage for the review of the effect of architectural planning and urban environment 3) Surveys of experts on structural safety in order to judge whether the demand of expansion is accepted or not. 4) Quantitative analysis of each item to compare fairness with reconstruction. Therefore, this study is intended to understand problems of the remodeling system that is currently operated. Moreover, it will be further reviewed that the expansion of households is feasible through the permission of expansion and it will be discussed that the revitalization of the apartment remodeling has a positive impact on the residential environment.

The Associated Factors with Utilization of Tests for Diabetes Complication and Hemoglobin A1c among Some Diabetes Patients (당뇨병 환자의 합병증검사 및 당화혈색소검사 수진 관련 요인)

  • Son, Young Eun;Ryu, So Yeon;Park, Jong;Han, Mi Ah;Gu, Hyae Min
    • Health Policy and Management
    • /
    • v.26 no.3
    • /
    • pp.207-218
    • /
    • 2016
  • Background: This study was performed to identify factors associated with the utilization of tests for diabetes complication and hemoglobin A1c (HbA1c) among diabetes patients in Jeollanam-do, Korea. Methods: The study subjects were 2,310 diabetes patients participated in 2014 community health survey in Jeollanam-do, Korea. Dependent variables were the utilizations of fundus examination, microalbuminuria test, and HbA1c test. The used statistical analysis methods were chi-square test and hierarchical regression analysis with weight in consideration of complex sample design. Results: The utilization rates of fundus examination, microalbuminuria test, and HbA1c test were 25.8%, 27.4%, and 12.3%, respectively. In the results of hierarchical regression, fundus examination was significantly related to age, education level in predisposing factors, residential area in enabling factors and recognition of blood sugar, drug therapy, and subjective health status in need factors. Microalbuminuria examination was significantly related to monthly income, residential area in predisposing and health screening, recognition of blood sugar, drug therapy, diabetic education, number of chronic disease, and subjective health status in need factors. HbA1c examination was significantly related to age, education level, marital status in predisposing factors, residential area in enabling factors and drinking, recognition of blood sugar, drug therapy, and diabetic education in need factors. Conclusion: The results of this study were shown that perception of their disease seriousness, education about diabetes management, and accessibility of tests were important to utilization of test for diabetes complication and HbA1c. It might be necessary to the develop and strength strategies for enhancing the utilization of tests for diabetes complication and management in diabetes patients.

A Study on the Characteristics of $PM_{10}$ and Air-borne Metallic Elements Produced in the Industrial City (산업도시 대기 중$PM_{10}$의 농도 및 금속원소 성분의 특성 연구)

  • 나덕재;이병규
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.23-35
    • /
    • 2000
  • PM10, which is below 10 ${\mu}{\textrm}{m}$ in a diameter, has a high deposition in the lung or the bronchus by breathing and is generally composed of a lot of organic matters, viruses, algae, mold, and metallic elements that are very toxic to people. This study identified the characteristics of concentration of PM10 and air-borne jmetallic elements produced in the industrial city, Ulsan, and analyzed the correlatuion between sources and generation patterns of PM10 and metallic elements. We classified the five areas(green, residential, heavy traffic, mechanic, and petrochemcal and non-ferrous metal) which might have different characteristics of sources of PM10 and metallic elements. The average concentrations of PM10 in the five areas were as follows(petrochemical and non-ferrous metal(99.9$\mu\textrm{g}$/㎥)>mechanic(77.5 $\mu\textrm{g}$/㎥)>heavy traffic(47.1 $\mu\textrm{g}$/㎥)>residential(39.3 $\mu\textrm{g}$/㎥)>green(32.8 $\mu\textrm{g}$/㎥)). Those of petrochemical and non-ferrous metal areas were higher than other areas. In this study, the average concentration trend of metallic elements contained in PM10 are shown as follows: Fe>Zn>Pb>Cu>Mn>Cr>As>Cd>Sn>Hg, respectively. The metallic elements identified in PM10 showed the highest concentration in the petrochemical and non-ferrous areas. Metal combinations showed that a high correlation among concentrations of heavy metals were as follows: As, Cd and Fe in the residential area; Zn, Mn, Cu and Pb in the mechanical area; and Zn, Cu, As, Pb in the petrochemical and non-ferrous industrial area.

  • PDF