• Title/Summary/Keyword: Requirement Analysis

Search Result 2,430, Processing Time 0.026 seconds

Integrity Evaluation and Root Cause Analysis of Cracks at the Volute Tongue of Centrifugal Pump (원심펌프 벌류트 혀의 균열 원인분석 및 건전성 평가)

  • Park, Chi-Yong;Kim, Jin-Weon;Kim, Yang-Seok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.7-14
    • /
    • 2000
  • This paper provides integrity evaluation and root cause analysis for defects observed at volute tongue, or cutwater, of the operating centrifugal pump in power plant. The cause of the cracks are analyzed and reviewed from the viewpoint of the operation and maintenance of the pumps, and the sample obtained from the cracked volute tongue of the pump are examined. At first, in-situ hardness test and microstructure examination were performed to understand the cause of cracking at volute tongue. The evaluation of structural integrity and the possibility of the crack propagation is also evaluated. Cracks were typical intergranular cracking and propagated along with prior austenite grain boundary. At easing volute tongue, the hardness was higher than ASTM requirement and a large amount of intergranular Cr carbide was precipitated. These were due to high C content in material. P content was also higher than ASTM requirement. Therefore, Cr carbide precipitation and P segregation at grain boundary, caused by higher C and P content in material, resulted in intergranular cracking of casing volute tongue. This procedure for integrity evaluation and root cause analysis is used to guide, and support the pump designer and manufacturer's material selection and process design to avoid a costly, unplanned outage of plant.

  • PDF

The Study on the Development of Composite Robot Hand for TFT-LCD Glass Transport (대면적 TFT-LCD 유리기판 이송용 복합재료 로봇 손 개발에 관한 연구)

  • Choi, Gi-Han;Han, Chang-Woo;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1357-1365
    • /
    • 2002
  • A robot hand is used to transport the glass substrate in TFT-LCD manufacturing process. Carbon/epoxy composite is one of the best materials for this kind of robot hand application, due to their lightweight, high stiffness, and good damping characteristics. Major requirement of the robot hand is given as allowable deflection under weight loading of glass substrate and robot hand itself. In this thesis, a carbon/epoxy robot hand was analyzed using finite element method and beam theory to determine the deflection of the hand under the loading that is equivalent to actual weight. Because natural frequency is one of the major interests in robot hand design for TFT-LCD manufacturing process, modal analysis is also conducted using finite element method and beam theory. A robot hand was manufactured, and actual deflection and natural frequency were measured to verify the analysis results and compliance to requirement. The test results showed good agreement with analysis results.

Electromagnetic Interference Test Result Analysis of Integral Reactor Digital I&C System (일체형 원자로 디지털 계측제어계통 전자파 장애 시험결과 분석)

  • Lee, Joon-Koo;Sohn, Kwang-Young;Park, Hee-Seok;Park, Heui-Yun;Koo, In-Soo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.213-218
    • /
    • 2003
  • Because of the development of digital technology, modern digital instrumentation & control systems are being innovativly developed in industrial plants. Whereas, many analog systems are still being used in nuclear plants, because of the demerits of digital equipment. As known, the demerits of digital equipment are the uncertainty and weaknesses in ambient environments such as smoke & electromagnetic interference In an Integral Reactor, a digital I&C system will be composed of microprocessor, memory and network card. Designers will apply new technique for digital equipment. Thus, it is important for digital I&C systems to operate according to designed functions & performance in the ambient environments during a life cycle. Digital I&C systems should have tolerance in such environments and environment qualification should be concluded To acquire electromagnetic interference qualification of digital equipment, this paper suggests an EMI test requirement. Designers should consider the electromagnetic compatibility and test digital equipment according to each test procedure. This paper involves an EMI test requirement and the results analysis of EUT(Equipment Under Test). Test result analysis will be used as electromagnetic compatibility design guides for Integral Reactor I&C systems.

  • PDF

Development of composite torsion shaft for the aircraft structure under multiple load condition (복합하중을 받는 복합소재 중공 토크바 설계)

  • Jeong, Jong-Jae;Kim, Seung-Chul;Kim, Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.6
    • /
    • pp.484-491
    • /
    • 2016
  • The purpose of this development is weight reduction of hollow type steel torque bar by changing the material from steel to composite. Structure analysis is executed by the finite element model generated by the structural load condition and geometric structure requirement. According to this analysis result, optimized ply sequence and wall thickness are defined. To simulate analysis result, torsion test for composite torque bar was performed. Throughout the test result, the stiffness and strength requirement of composite torque bar was verified.

Regional Integrity Analysis using modernized GPS, Galileo and SBAS

  • Han, Sang-Sul;Shin, Dae-Sik;Cho, Jong-Chul;Park, Chan-Sik;Jun, Hyang-Sik;Nam, Gi-Wook;Lee, Sang-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.417-421
    • /
    • 2006
  • ICAO defines performance requirements of navigation system such as accuracy, integrity, continuity and availability. The integrity is most significant performance requirement in aviation where safety of life is crucial. Many researches on this topic anticipate that GPS with SBAS or Galileo can meet APV requirements and GPS with GBAS or Galileo with GBAS will meet CAT II and III requirements. These performance expectations are based on global analysis. In this paper regional integrity analysis in Korea using various combinations of modernized GPS, Galileo and SBAS is given. The simulation results show that CAT I requirement can be met using modernized GPS and Galileo alone, however, CAT II and III are not met even augmenting SBAS because of VPL. A more efficient augmentation such as GBAS which can reduce VPL dramatically is required to meet CAT II and III in Korean region.

  • PDF

Minimum thickness of flat plates considering construction load effect

  • Hwang, Hyeon-Jong;Ma, Gao;Kim, Chang-Soo
    • Structural Engineering and Mechanics
    • /
    • v.69 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • In the construction of flat plate slabs, which are widely used for tall buildings but have relatively low flexural stiffness, serviceability problems such as excessive deflections and cracks are of great concern. To prevent excessive deflections at service load levels, current design codes require the minimum slab thickness, but the requirement could be unconservative because it is independent on loading and elastic modulus of concrete, both of which have significant effects on slab deflections. In the present study, to investigate the effects of the construction load of shored slabs, reduced flexural stiffness and moment distribution of early-age slabs, and creep and shrinkage of concrete on immediate and time-dependent deflections, numerical analysis was performed using the previously developed numerical models. A parametric study was performed for various design and construction conditions of practical ranges, and a new minimum permissible thickness of flat plate slabs was proposed satisfying the serviceability requirement for deflection. The proposed minimum slab thickness was compared with current design code provisions and numerical analysis results, and it agreed well with the numerical analysis results.

Position Tolerance를 포함한 모형의 Stack Analysis 비교연구

  • 김영남;장성호
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.05a
    • /
    • pp.99-103
    • /
    • 2002
  • It is the basic requirement of product characteristics to specify geometric dimensions and tolerances during design process of parts assembly. Therefore, there are many tolerance stack analysis method to explain tolerance zone. Tolerance stack analysis is to calculate gap using tolerances which includes geometric and coordinate dimension. In this study, we compared several different stack analysis method and try to suggest more general method called the Virtual Method to analyze tolerance stack.

  • PDF

Application of TAM and QFD for analyzing the user requirement in u-Healthcare System - Focused on fitness service (u-헬스케어 시스템에서 사용자 요구사항을 분석하기 위한 TAM과 QFD의 적용 - u-휘트니스 서비스 중심)

  • Kim, Min-Cheol
    • Journal of Digital Convergence
    • /
    • v.10 no.3
    • /
    • pp.191-196
    • /
    • 2012
  • The importance of hi-tech communications technology including mobile or ubiquitous system and the related business field is currently expanding. In terms of wellness for enhancing quality of individual life, ICT technology became a requirement, not an option. The first purpose of this study is to identify factors that influence user's perceived usefulness & perceived ease of use related to the acceptance of TAM focused on ubiquitous fitness service through multiple regression analysis, thereby discovering important factors influencing consumer behavior. In conjunction with the result, the second purpose of this study has also its implication on the u-Healthcare system development using QFD. That is, this research is to propose the possibility of combining the external variables of TAM to u-Healthcare system service characteristics with user requirement reflected by using QFD method. Based on these results, the suitable system may be constructed and developed.

A study on the analysis of energy performance for zero-energy building of rural village hall - Focused on the Jung Juk 4-le village hall - (농촌 마을회관 제로에너지 건축물 구축을 위한 에너지 성능 분석 연구 - 충남 태안군 정죽4리 마을회관을 중심으로 -)

  • Park, Mi-Lan;Choi, Jeong-Man;Lee, Jeong-Hun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.4
    • /
    • pp.1-8
    • /
    • 2018
  • In this study, we survey the 2 buildings at the Central 1 and 8 buildings at the Central 2, which are divided by each climate region in the rural regions. Major heat loss factors are 47% loss of the outer shell including outer wall, roof, and bottom, 30% loss through window, and 23% loss through crevice wind. We analyze the energy simulation of ECO2 program to construct a zero energy building regarding village hall located in Jung Juk 4-le at Centeral 2. We simulate the primary energy requirement regarding village hall and the simulated results show the $265.3kWh/m^2{\cdot}a$ and it may estimate '2' energy efficiency grade. The energy requirement regarding village hall is the $183.2kWh/m^2{\cdot}a$ when the passive technology are applied in village hall. We research total amount of energy requirement in village hall when the passive and active technologies such as solar cell with 3kW and solar thermal with $20m^2$, geothermal power with 17.5kW. The simulated results show the improved energy efficiency certification grade with $1^{{+}{+}{+}}$ due to the reduced primary energy requirement with 73% when passive technology including 3kW of solar panel is applied and the energy independence rate is 54%, which is estimated to be 4th grade of zero energy buildings. The order of energy consumption are solar panel, solar thermal, and geothermal power under applied passive technology in the building. In order to expand the zero energy building, it is necessary to introduce the zero energy evaluation system in the rural region.

Lysine Requirement of Broiler Chickens Fed Low-density Diets under Tropical Conditions

  • Aftab, Usama;Ashraf, Muhammad;Mumtaz, Abdul Samad;Jiang, Zhirong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.6
    • /
    • pp.939-943
    • /
    • 2007
  • Two experiments were conducted to determine the lysine requirement of straight-run broiler chickens ($Hubbard{\times}Hubbard$) during the period 4-21 (Exp. 1) and 21-40 (Exp. 2) days of age. Experiments were conducted during the summer months (June-August) in open-sided houses, thus exposing chicks to chronic heat stress. Daily min-max temperature averaged $28-40^{\circ}C$ (Exp. 1) and $28-36^{\circ}C$ (Exp. 2). Lysine deficient basal diets were formulated to contain low-nutrient-density, i.e., 2,700 kcal per kg ME, 18.6% CP (Exp. 1), and 2,750 kcal per kg ME, 17.1% CP (Exp. 2), to mimic typical commercial broiler diets used in Pakistan. Diets were supplemented with L-lysine HCl to provide total lysine level ranging from 0.85 to 1.10% (six increments) and 0.72 to 1.02% (six increments), respectively in Exp. 1 and 2. Live performance data were subjected to quadratic analysis and requirement was defined as the level achieving 95% of maximum or minimum values. Lysine requirements were found to be 0.98 and 0.97% total lysine, respectively, for gain and feed efficiency during 4-21 days, and 0.87% total lysine for both gain and feed efficiency during 21-40 days of age. Calculated on a digestible lysine basis, the estimates were 0.85 and 0.84%, respectively, for gain and feed efficiency during 4-21 days of age; and 0.75% for gain and feed efficiency during 21-40 days of age.