• Title/Summary/Keyword: Required evacuation time

Search Result 82, Processing Time 0.019 seconds

A Study on the Investigation of Safety Consciousness and Improvement Plan for Fire Safety Manual in Postpartum Care Center (산후조리원 화재안전매뉴얼구축을 위한 안전의식 조사 및 개선방안에 관한 연구)

  • Jin, Seung-Hyeon;Kim, Hye-Won;Han, Ji-Woo;Park, Sung-Ha;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.96-97
    • /
    • 2018
  • Facilities used by senior citizens, infants, and disabled people have characteristics that make it difficult to escape on their own or require a lot of evacuation time. Therefore, to ensure safety in case of fire, clear measures for securing safety of facilities, fire response methods, and training are required in accordance with the regulations. In case of postnatal care center facilities, newborn babies and mothers reside 24 hours a day, and as they are located in high-rise and multi-use facilities, measures for fire safety are necessary, but the domestic manual lacks. Accordingly, a field survey for security of the manual revealed that the establishment of awareness and facilities on temporary waiting areas and smoke control, which are easy for evacuation and fire safety, was a problem.

  • PDF

A Study on the Development of Fire Alarm System with Evacuation Lighting and Voice Alarm Functions (피난조명 및 음성경보 기능을 내장한 화재경보시스템 개발에 관한 연구)

  • Lee, Gun-Ho;Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.25-34
    • /
    • 2018
  • This study investigated the development of a fire alarm system with evacuation lighting and voice alarm functions. The performance of a fire detector and system with independently built-in evacuation lighting and voice alarm functions was confirmed for early recognition of fire and to allow visibility of the evacuation route in the event of fire. This new system satisfied model recognition and product testing technological standards with 1.62 lx average illumination, 89.7 dB average sound and 86.1 dB average voice. From additionally testing the evacuation performance of this new system, it was confirmed that the evacuation time decreased by 63.08% to 67.82% under the experimental conditions compared to conventional systems. The new system can minimize fire damage by setting off voice alarms to prevent failure of fire recognition and by flashing emergency lighting to secure the minimum required visibility range for evacuation. Therefore, it is considered that it will be utilized as a fire alarm system with appropriateness and usefulness by considering people with hearing or visual impairment.

Analysis of the Evacuation Safety with the Structure and Opening/Closing of Exits in a Fire at a Highway Service Area (고속도로 휴게소 화재 시 출입문의 구조와 개폐에 따른 피난안전성 분석)

  • Lee, Jai Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.419-425
    • /
    • 2021
  • This study analyzed the safety of evacuation according to the number of exits and the direction of evacuation routes with evacuation simulations of the Pathfinder in case of a fire at a highway service area. It was also analyzed of the difference in RSET by comparing the single or double types of the exit of a facility. The results were as follows. When only one direction exit was opened, all of the RSET were exceeded. When two or more different directions were opened according to the general principle of evacuation, all results met the RSET. The simulations showed that two or more different directions were more shortened in RSET than the one same direction. The result of the types of doors showed that the single type door was shortened in RSET rather than the double type doors. For the evacuation safety in a fire at the highway service areas, firstly, it is necessary to secure two or more exits in a fire at all times. Secondly, the exits should not be same directions. Finally, it is suggested that the exit should be installed with a single type of door.

A Study on the Evacuation Risk of Simultaneous Fires from Exterior (외장재에 의한 동시다발적인 화재의 피난위험성에 관한 연구)

  • Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.48-54
    • /
    • 2012
  • In order to study on the evacuation risk when connate fires caused by vertical fire spread of the exterior occurs, the egress simulations based on the relevant scenarios has carried out. As a result of it, ASET (permitted evacuation time) was reached in between 550 to 650 seconds in entire floors after vertical smoke spread from fire of combustible exteriors. In particular, ASET was 358 seconds in the first floor, 490 seconds in the six floor and 473 seconds in the tenth floor. In addition, five floors of all levels, the 1st floor, the 6th floor and the 28th floor ~30th floor, show RSET (minimum evacuation time) which is bigger than ASET as evacuation risk. This result presents occupants in high rise buildings with more than 15 floors might not be able to egress of them using staircases due to huge population attempting to evacuate simultaneously. Particularly, 699 people in the upper levels by smoke from the first floor are having difficulty escaping this building since ASET on the first floor adjacent to the ignition point was 358 seconds which is relatively reached fast. Considering a prevention method of the fire and smoke spread, architects have to use non-combustible exterior in the building's facade to be required as an active fire protection system.

A Study on Evacuees Risk Assesment for Application of Spatial Risk Information (공간위험정보를 적용한 대피자 위험성평가에 관한 연구)

  • Hong, Seungbum;Jang, Jae-Soon;Park, Hyun-A;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.8-12
    • /
    • 2015
  • Performance Based Design is evaluating after each calculatiuon ASET and RSET. Risk informaion values such as heat, smoke, toxic gas etc are extracted by FDS in this study. These Risk informaion values by FDS apply Artisoc (evacuation simulator). Building structure made $60m{\times}65m$, exit number is made 2 positions and people in this building are 50 ramdonly. 20 times (case1~case 20) simulated and analysis evacuees risk by evacuated route positions.

Optimal Path Finding based on Raster GIS in Indoor Spaces (건물내부공간에서의 Raster GIS기반 최적경로 탐색)

  • Kim, Byung-Hwa;Jun, Chul-Min
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • People tend to spend more time in indoor spaces than before such as shopping malls and subway stations. As buildings become larger and more complex, people feel difficulty in finding their ways to destinations. Consequently, a means to provide better paths can aid people in reducing time for finding ways. Routing information in large indoor spaces is especially required in emergency cases as fire, power failure and terror. This study suggests to compute optimal paths using $A^*$ algorithm based on raster GIS data structure. The suggested method can be used either in daily lives for path provision or in emergency cases for evacuation, and is illustrated on a campus building.

An Experimental Study on the Pressure Change in the Type of Elevator Hoistways (엘리베이터 승강로 형식별 압력변동에 관한 실험 연구)

  • Kim, Hak-Joong;Kim, Boem-Gyu;Park, Yong-Hwan;Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.139-144
    • /
    • 2010
  • Recently, evacuation safety of building resident become the major concern, as the building has been higher and more complicated. Many high-rise multi use buildings are under construction in Korea. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is progressing. This study shows the pressure change in various types of hoistway when elevator is moving. Experiments were performed in 4 different types of hoistway, and showed big difference in pressure change between the type of hoistway. The pressure change in single hoistway that have one car is bigger than that in multi hoistway that have multi cars. The results of this study can be used for the study of elevator piston effect as basic data.

A Study on the Estimation for the Flow Coefficient of Elevator Shaft (엘리베이터 샤프트의 유량계수 산정에 관한 연구)

  • Kim, Hak-Joong
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.2
    • /
    • pp.148-157
    • /
    • 2012
  • Recently, evacuation safety of building residents becomes the major concern, as the building has been higher and more complicated. Many high-rise multi use buildings are under construction in Korea. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is being progressed. Elevator shaft flow coefficient is the major factor for the calculation of elevator piston effect. The results of this study can be used for the study of elevator piston effect as basic data. The flow coefficient simulation was performed using FLUENT, commercial CFD program. As a result of the flow coefficient simulation, the coefficient is 0.88 considering the safety factor. This result is verified that the result of experimental study, 0.86 is conservative.

Emergency Rescue Guidance Scheme Using Wireless Sensor Networks (재난 상황 시 센서 네트워크 기반 구조자 진입 경로 탐색 방안)

  • Joo, Yang-Ick
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1248-1253
    • /
    • 2019
  • Using current evacuation methods, a crew describes the physical location of an accident and guides evacuation using alarms and emergency guide lights. However, in case of an accident on a large and complex building, an intelligent and effective emergency evacuation system is required to ensure the safety of evacuees. Therefore, several studies have been performed on intelligent path finding and emergency evacuation algorithms which are centralized guidance methods using gathered data from distributed sensor nodes. However, another important aspect is effective rescue guidance in an emergency situation. So far, there has been no consideration on the efficient rescue guidance scheme. Therefore, this paper proposes the genetic algorithm based emergency rescue guidance method using distributed wireless sensor networks. Performance evaluation using a computer simulation shows that the proposed scheme guarantees efficient path finding. The fitness converges to the minimum value in reasonable time. The density of each exit node is remarkably decreased as well.

A study on pedestrian path search based on the shortest distance algorithm using Map API (Map API를 활용한 최단 거리 알고리즘 기반 보행자 경로 탐색 연구)

  • Jeon, Sung-woo;Kim, Yunbae;Kim, Junyoung;Park, Seonyoung;Jung, Heo-kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.219-221
    • /
    • 2022
  • In recent summer, as it is concentrated, even in mountainous areas, flooding and flooding cause casualties in pedestrian evacuation situations. To compensate for this, a system that detects the occurrence of flooding and allows pedestrians to evacuate safely is required. Therefore, in this paper, we propose a research on pedestrian path search based on the shortest distance algorithm using Map API. The pedestrian route search system outputs a map using the T Map API, selects nearby buildings as shelters, and stores data. A shelter close to the pedestrian's current location is selected, and the shortest route is output and the distance and time are provided. If there is a problem with the current route during evacuation, another shelter route is provided from the current location. Therefore, it is thought that the pedestrian route search evacuation system proposed in this paper will prevent accidents during evacuation.

  • PDF