• 제목/요약/키워드: Reproducibility of result

검색결과 310건 처리시간 0.032초

X선 진단영역 에너지 측정을 위한 Photo-Diode 선량계(PD-2000)의 개발 (The development of photo-diode dosimeter(PD-2000) for the diagnostic X-ray Energy)

  • 김성철;이우철;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.27-32
    • /
    • 2000
  • It was produced radiation dosimeter used photo-diodes for which ionization by x-ray was applied and evaluated the value of utility in clinics as compared with ion-chamber. The result obtained were as follows : 1. Comparison of ion-chamber with photo-diode dosimeter's x-ray output by the change of x-ray tube voltage, and the ratio of ion-chamber to diode was $0.96{\sim}1.02$ which was not affected by x-ray beam quality. 2. The ratio of ion-chamber to diode was 0.96 by change of tube current and 0.97 by change of exposure time that is not affected by x-ray quantity. 3. The ratio of ion-chamber to diode was $0.97{\sim}1.04$ by thickness and $0.93{\sim}1.10$ by radiation field that is little affected by second ray quantity. 4. Reproducibility of photo-diode dosimeter was 0.011(CV) and it is a good result. 5. Photo-diode dosimeter was affected by the surface angle of detector over 30 degrees. Produced dosimeter was small, light, and meets good result compared with ionization chamber. It was expected come into wide use in clinic.

  • PDF

골밀도 상태에 따른 검사자의 재현성 평가 (The Precision Test Based on States of Bone Mineral Density)

  • 유재숙;김은혜;김호성;신상기;조시만
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.67-72
    • /
    • 2009
  • ISCD (International Society for Clinical Densitometry)에서는 골밀도 검사자의 전문성을 키우고자 검사자의 재현성 시험을 필수 자격조건으로 요구하고 있다. 하지만, 재현성 시험의 대상자 선정에 대한 권고안이 불확실하여 골밀도 상태에 따른 그룹별 재현성을 시험해 골밀도 차이가 재현성 시험에 영향을 주는지 알아보았다. 2008년 1월부터 6월까지 본원에 내원한 300명(57.8세$\pm$9.02)의 여성 골밀도 수검자를 두 그룹으로 나누어 4명의 검사자가 재현성을 시험하였다. A그룹의 120명은 4명(a,b,c,d)의 검사자가 골밀도 상태와 관계없이 동일한 방법으로 요추부와 대퇴부를 30명씩 두 번 측정하였고 나머지는 B그룹으로 두 명의 검사자가 골밀도 상태에 따라정상, 골다공증, 골감소증 군으로 분류하여 A그룹과 동일한 방법으로 재현성을 시험하였다. 사용된 장비는 GE Lunar Prodigy Advance (Vr11.4)이고, 수집된 자료는 ISCD에서 배포된 Precision Tool을 이용하여 각각의 변동계수율(%CV)를 알아보았으며 SPSS 14.0 통계 프로그램을 사용하여 분석하였다. A그룹의 %CV는 a, b,c, d 검사자가 각각 요추부 1.08, 0.83, 0.72, 1.37%, 대퇴부 1.08, 1.04, 1.4, 0.58 %로 산출되었고 동일 골밀도 상태의 요추와 대퇴부를 비교하면 재현성이 일관되지 않았다. B그룹에서는 a의 요추부 정상군 %CV가 1.26으로 가장 높았고 대퇴부는 0.94로 골다공증 군이 가장 높게 측정됐다. b는 요추부의 정상군 %CV가 0.97로 가장높았고 대퇴부는 1.04로 골다공증 군에서 가장 높았다. 요추부의 정상군과 대퇴부의 골다공증 군은 %CV가 가장 높게 나타나 골밀도 상태에 따른 재현성이 일관되지 않았다. 본원의 골밀도검사 재현성 시험은 골다공증 상태의 수검자를 제외한다. 그 이유는 ISCD의 대상자 선정이 불확실하고, 골밀도가 낮을수록 장비의 골 인식도가 떨어져 재현성 시험을 시행할 경우, 검사자의 수작업을 요하므로 좋은 재현성을 얻기 힘들기 때문이다. 하지만 재현성 결과값은 LSC (Least Significant Change)에 영향을 주기 때문에 장비, 검사자, 수검자에서 발생할 수 있는 모든 오차를 반영해야 한다. 실험결과는 골밀도 상태가 재현성에 영향을 주지 않았으며, 따라서 정상, 골감소, 골다공증의 구별 없이 대상자의 선정 폭을 넓혀 대상에 구애 받지 않고 보다 정확한 의미의 재현성 시험을 해야 할 것으로 판단된다.

  • PDF

장단기유출 양용저유 탱크 모델의 개발에 관한 연구 (II) (Studies on the Development of Storage Tank Model for both Long and Short Terms Runoff (II))

  • 이순혁;박명근
    • 한국농공학회지
    • /
    • 제33권2호
    • /
    • pp.51-60
    • /
    • 1991
  • The main objective of this study is to examine the adaptability for the large watershed of the storage tank model which can be applied for the analysis of both long and short terms runoff developed on the basis of hydrologic data for a smaH mountaineous watershed. The results obtained in this study are summarized as follows ; 1. Areal rainfalls of the Dae Chong watershed were calculated by Thiessen method composed of 9 Thiessen networks. 2. Optimal parameters for two types, Model A and Model B of tank models were derived through calibration procedure by standardized Powell method. 3. Monthly simulated flows of Model B are seemed to be closer to the monthly observed than those of Model A during calibration period in the long terms runoff. 4. Relative errors for the simulated flood flows of Model B were apperaed as lower percentage to the observed than those of Model A during calibration period in the short terms runoff. 5. Daily simulated hydrographs of Model B are seemed to be closer to the daily observed than those of Model A during verification period in the long terms runoff. Significance of Model B was highly acknowledged in comparison with Model A in the correlation analysis between annual observed and annual simulated runoff. 6. Reproducibility of simulated flows for Model B is generally seemed to be better than that of Model A during calibration period in the short terms runoff. 7. It can be concluded that reproducibility of Model B is superior to that of Model A in the long and short terms runoff even a large watershed like the result of the small one. 8. It was verified that adaptability for the large watershed of Model B is superior to that of Model A between the two models which were developed by a small watershed characteristics for both long and short terms runoff. 9. Further study for getting a suitable tank model is desirable to be established by the decision, calibration method of initial parameters of tank model and by additional application of another watershed with different watersheds and meterological characteristics.

  • PDF

유리선량계 특성평가 및 판독 보정인자에 대한 불확도 평가 (Evaluation of RPL Glass Dosimeter Characteristics and Uncertainty Evaluation of Reading Correction Factors)

  • 목성윤;강영록;김효진;계용욱;안현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.219-229
    • /
    • 2023
  • In this study, basic characteristics such as reproducibility, linearity, and directionality of RPL glass dosimeters were evaluated to improve the reliability of dose evaluation through RPL glass dosimeters, and uncertainty elements such as sensitivity by glass element and magazine slot sensitivity were evaluated. Using a mathematical model to calibrate the measured values of the RPL glass dosimeter, the measurement uncertainty was calculated assuming an example. As a result of the characteristic evaluation, the RPL glass dosimeter showed excellent performance with a standard deviation of ±1% (1 SD) for the reproducibility of the reading process, a coefficient of determination for linearity of 0.99997. And the read-out of the RPL glass dosimeter are affected by the circular rotation direction of the glass dosimeter during irradiation, fading according to the period after irradiation, the number of laser pulses of the reader, and response degradation due to repeated reading, it is judged that measurement uncertainty can be reduced by irradiation and reading in consideration of these factors. In addition, it was confirmed that the dose should be determined by calculating the correction factors for the sensitivity of each element and, the sensitivity of each reading magazine slot. It is believed that the reliability of dosimetry using glass dosimeters can be improved by using a mathematical model for correction of glass dosimeter readings and calculating measurement uncertainty.

The accuracy of linear measurements of maxillary and mandibular edentulous sites in conebeam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

  • Ganguly, Rumpa;Ramesh, Aruna;Pagni, Sarah
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view ($13cm{\times}16cm$) and small field of view ($5cm{\times}8cm$) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리 (The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System)

  • 김상우;임재동;한동균;성열훈
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

격자단위 국가 표준 시나리오를 적용한 농촌용수구역단위 자료변환 방법 비교 연구 (Study on the Methodology for Generating Future Precipitation Data by the Rural Water District Using Grid-Based National Standard Scenario)

  • 김시호;황세운
    • 한국농공학회논문집
    • /
    • 제65권3호
    • /
    • pp.69-82
    • /
    • 2023
  • Representative meteorological data of the rural water district, which is the spatial unit of the study, was produced using the grid-based national standard RCP scenario rainfall data provided by the Korea Meteorological Administration. The retrospective reproducibility of the climate model scenario data was analyzed, and the change in climate characteristics in the water district unit for the future period was presented. Finally the data characteristics and differences of each meteorological element according to various spatial resolution conversion and post-processing methods were examined. As a main result, overall, the distribution of average precipitation and R95p of the grid data, has reasonable reproducibility compared to the ASOS observation, but the maximum daily rainfall tends to be distributed low nationwide. The number of rainfall days tends to be higher than the station-based observation, and this is because the grid data is generally calculated using the area average concept of representative rainfall data for each grid. In addition, in the case of coastal regions, there is a problem that administrative districts of islands and rural water districts do not match. and In the case of water districts that include mountainous areas, such as Jeju, there was a large difference in the results depending on whether or not high rainfall in the mountainous areas was reflected. The results of this study are expected to be used as foundation for selecting data processing methods when constructing future meteorological data for rural water districts for future agricutural water management plans and climate change vulnerability assessments.

나노구조 카본블랙/HDPE 복합재료의 전기적 특성: 전자선 조사에 의한 PTC 특성변화 (Electrical Properties of Nanostructured Carbon Black-filled HDPE Composites: Effect of Electron Beam Irradiation on PTC Characteristics)

  • 박수진;송수완;서민강;이재락
    • Composites Research
    • /
    • 제16권1호
    • /
    • pp.19-25
    • /
    • 2003
  • 본 연구에서는 나노구조를 갖는 카본블랙이 충전된 CB/HDPE 복합재료를 용융 혼합법으로 제조한 후 온도변화에 따른 전기적 특성을 고찰하였다. 복합재료의 전기적 재현성 향상과 negative temperature coefficient (NTC) 현상의 제거를 위하여 전자선을 30-150 kGy로 조사하였으며, 조사된 복합재료의 가교함량 분석은 용매 추출법을 이용하였다. 실험결과, CB/HDPE 복합재료의 PTC 세기는 카본블랙의 함량과 입자크기에 크게 영향을 받으며. 가교함량의 급격한 증가에 따른 NTC 현상의 제거는 전자선 흡수선량이 60 kGy일 때였다. 또한 전자선 조사를 통하여 전기적 재현성이 향상되었는데, 이는 복합재료의 가교도 증가에 따른 수지의 용융온도 근처에서의 카본블랙 유동성의 감소 때문이라 사료된다.

GC-SCD를 이용한 가스연료 중 황화합물의 정량 (Determination of Sulfur Compounds in Gaseous Fuel by Gas Chromatography-Sulfur Chemiluminescence Detection)

  • 도이주;고재석;김호진
    • 대한화학회지
    • /
    • 제43권5호
    • /
    • pp.517-521
    • /
    • 1999
  • 가스연료 중의 부취제 농도를 기체 크로마토그래피법으로 분석하기 위해 황화합물에 대한 선택성, 직선성, 감도가 매우 우수한 황 화학광 검출기(SCD)를 이용하여 측정하였다. 그리고, 기존의 GC-SCD에 의한 황화합물 분석방법과는 달리 황화합물의 흡착으로 인한 반복성 및 재현성 문제를 해결하는 실험방법을 이용하였다. 이러한 방법에 의하여, 액화석유가스에 첨가하고 있는 황화이메틸, t-부틸메르캅탄, 황화에틸메틸에 대하여 얻은 검정 곡선은 직선성을 잘 보여주고 있다. 실제 시료 중 위의 세가지 황화합물에 대한 실험결과의 정밀성을 측정한 결과, 4일동안 각3회 반복실험하였을 때 높은 재현성을 보여주었고, 농도의 변동계수(coefficient of variation)가 3% 미만의 값을 나타내었다. 결과적으로, 본 연구에 의한 실험방법은 저유소 및 충전소의 액화석유가스 시료에 첨가된 황 함유 부취제의 농도를 신속, 정확하게 측정하는, 매우 정밀성이 높고 유용한 방법이다.

  • PDF

마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구 (A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode)

  • 신교철;윤형근
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.59-62
    • /
    • 2004
  • 본 논문에서는 마이크로필름과 탄소막 전극을 이용하여 개발한 소형 방사선측정기의 특성을 평가하였다. 전극은 5 mm 직경의 고전압전극, 3.3 mm 직경의 수집전극, 그리고 넓이가 0.7 mm인 보호전극으로 구성되었으며, 이온수집 공동의 부피는 0.016 ㎤이었다. 6 MV X-선을 이용하여 제작된 측정기에 대한 전기적 특성을 조사하였는데, 누설전류는 0.1 pA, 재현 오차가 0.1% 이하, 선량률 효과는 1.5% 이하, 분극효과는 2.4% 이하로 나타났다. 개발된 측정기의 전기적 특성은 양호한 것으로 평가되며, 추후 깊이선량률, 빔측면도와 같은 선량분포에 대한 특성의 평가가 요구된다.

  • PDF