• Title/Summary/Keyword: Replacement

Search Result 7,124, Processing Time 0.039 seconds

A Block Replacement Scheme using Analytic Hierarchy Process in Hybrid HDD (하이브리드 하드디스크에서 AHP를 적용한 블록 교체 기법)

  • Kim, Jeong-Won
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.5
    • /
    • pp.45-52
    • /
    • 2015
  • The read performance of hybrid hard disk is better than the legacy hard disk and power consumption is also considerably low. As blocks with enough localities may be located in the non-volatile cache whose size is generally limited, an effective block replacement scheme is required. As this replacement is inevitably affected by various parameters, we define this issue as a kind of multiple criteria decision model. To solve this problem, this paper suggests a new block replacement algorithm based on the analytic hierarchy process. Through simulation for our model, we confirmed that the proposed model could be used as a replacement algorithm of the hybrid hard disk as it may improve boot time as well as response time of general applications.

Reduction of Autogenous Shrinkage of HPFRCC Depending on Changes of ERCO Replacement Ratio and Fiber Replacement Ratio (ERCO 혼입율과 섬유혼입비 변화에 따른 HPFRCC의 자기수축저감)

  • Lee, Jea-Hyeon;Baek, Cheol;Jo, Man-Ki;Jo, Sung-Jun;Lee, Jong-Tea;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.30-31
    • /
    • 2016
  • As the treatments of many kinds of explosive objects increase recently, it is in the trend that explosion accidents increase. Thus, many studies on HPFRCC (High-performance Fiber-reinforced Cement Composites) whose ductility is enhanced are being conducted actively in order to minimize the damages from explosion accidents. However, HPFRCC, the self-shrinkage of HPFRCC is on the rise as a problem since it becomes ultra-high strengthened by using low W/B. Thus, in this study, it is intended to evaluate the capacity for reducing the self-shrinkage of HPFRCC depending on some changes of ERCO(Emulsified Refined Cooking Oil) replacement ratio and the fiber replacement ratio between some short steel fibers (SS) and some long organic fibers (OL). As a result, it was found that some excellent effects are exerted since the self-shrinkage was reduced a lot as the ERCO replacement ratio increases and the fiber replacement ratio of SS rather than OL increases.

  • PDF

Alloplastic total temporomandibular joint replacement using stock prosthesis: a one-year follow-up report of two cases

  • Lee, Sang-Hoon;Ryu, Da-Jung;Kim, Hye-Sun;Kim, Hyung-Gon;Huh, Jong-Ki
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.6
    • /
    • pp.297-303
    • /
    • 2013
  • Alloplastic total replacement of the temporomandibular joint (TMJ) was developed in recent decades. In some conditions, previous studies suggested the rationale behind alloplastic TMJ replacement rather than reconstruction with autogenous grafts. Currently, three prosthetic products are available and approved by the US Food and Drug Administration. Among these products, customized prostheses are manufactured, via computer aided design/computer aided manufacturing (CAD/CAM) system for customized design; stock-type prostheses are provided in various sizes and shapes. In this report, two patients (a 50-year-old female who had undergone condylectomy for the treatment of osteochondroma extending to the cranial base on the left condyle, and a 21-year-old male diagnosed with left temporomandibular ankylosis) were treated using the alloplastic total replacement of TMJ using stock prosthesis. The follow-up results of a favorable one-year, short-term therapeutic outcome were obtained for the alloplastic total TMJ replacement using a stock-type prosthesis.

Optimal Periodic Replacement Policy Under Discrete Time Frame (이산 시간을 고려한 시스템의 교체와 수리 비용 최적화 연구)

  • Lee, Jinpyo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.1
    • /
    • pp.61-69
    • /
    • 2020
  • Systems such as database and socal network systems have been broadly used, and their unexpected failure, with great losses and sometimes a social confusion, has received attention in recent years. Therefore, it is an important issue to find optimal maintenance plans for such kind of systems from the points of system reliability and maintaining cost. However, it is difficult to maintain a system during its working cycle, since stopping works might incur users some troubles. From the above viewpoint, this paper discusses minimal repair maintenance policy with periodic replacement, while considering the random working cycles. The random working cycle and periodic replacement policies with minimal repair has been discussed in traditional literatures by usually analyzing cases for the nonstopping works. However, maintenance can be more conveniently done at discrete time and even during the working cycle in real applications. So, we propose that periodic replacement is planned at discrete times while considering the random working cycle, and moreover provide a model in which system, with a minimal repair at failures between replacements, is replaced at the minimum of discrete times KT and random cycles Y. The average cost rate model is used to determine the optimal number of periodic replacement.

Effects of the Mitral Valve Replacement with Preservation of Posterior Mitral Leaflet and Chorda Tendinae for Mitral Valvular Disease (승모판막질환에서 승모판 대치술시 승모판 후엽 및 건삭 보존의 효과)

  • Jo, Gang-Rae;Kim, Jong-Won
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.488-500
    • /
    • 1990
  • Author compared the effect of surgical methods between 40 patients who received mitral valve replacement with complete excision of the mitral valve[resected group] and 41 patients who received mitral valve replacement with preservation of posterior chorda tendineae and posterior mitral leaflet[preserved group] from 1985. 2. to 1989. 4. at cardiothoracic department of Pusan National University Hospital.v 1. There was no significant difference between the preserved group and resected group in cardiopulmonary bypass time and aortic cross clamping time and NYHA classification. 2. In preserved group of Mitral stenosis and Mitral regurgitation, the left ventricular functions were much improved after mitral valve replacement than resected group, but there was not so difference between the preserved group and reserved group in Mitral steno-regurgitation. 3. There were remarkable decrease in complication rate in preserved group compared to resected group. And also the death rates were remarkably decreased in preserved group which was 4.9% compared to resected group which was 17.5%. As the preservation of the posterior mitral leaflet and chorda tendineae during mitral valve replacement in mitral valve disease showed significantly improved effects in the maintaining of left ventricular function and reducing the postoperative complication, I assume the preservation of posterior mitral leaflet and chordae during mitral valve replacement will bring better result.

  • PDF

Effect of performance method of sand compaction piles on the mechanical behavior of reinforced soft clay

  • Kwon, Jeonggeun;Kim, Changyoung;Im, Jong-Chul;Yoo, Jae-won
    • Geomechanics and Engineering
    • /
    • v.14 no.2
    • /
    • pp.175-185
    • /
    • 2018
  • Sand Compaction Piles (SCPs) are constructed by feeding and compacting sand into soft clay ground. Sand piles have been installed with irregular cross-sectional shapes, and mixtures of both sand and clay, which violate the design requirement of circular shape according to the replacement area ratio due to various factors, including side flow pressure. Therefore, design assumptions cannot be satisfied according to the conditions of the ground and construction and the replacement area ratio. Two case histories were collected, examined, and interpreted in order to study the effect of the shape of SCPs. The effects of the distortion of SCP shape and the mixture of sand and clay were studied with the results of large direct shear tests. The design internal friction angle was secured with the irregular cross-sectional sand piles regardless of the replacement area ratio. The design internal friction angle was secured regardless of mixed condition when the mixture of sand and clay was higher than the replacement area ratio of 65%. Therefore, systematic construction management is recommended with a replacement area ratio below 65%.

Quantitative Interchangeability Evaluation Method Considering Part Replacement Decision Algorithm of Small Equipment (소형장비의 부품 교체단위결정 알고리즘을 고려한 정량적인 교체성 평가방법)

  • Kim, Jong-Do;Son, Woo-Hyun;Park, Sang-Jin;Mok, Hak-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.5
    • /
    • pp.537-544
    • /
    • 2019
  • In currently electronic systems, the speed of information integration has increased due to the development of electronic technology. However, due to the increase in the number of parts and groups, the product structure has become complicated. In this paper, a study was conducted to evaluate quantitatively the replacement of a small equipment. First, the level of the replacement was determined through the algorithm for the replacement level of parts. Next, we defined the ease of detail replacment, and the factors for each detail replacement. In order to calculate the weighting of the detail ease, we performed the analysis of the replacement process of subcomponents of communication exchanger and defined the evaluation criteria. Finally, the completion of the evaluation check sheet and the evaluation score table.

Potential use of mine tailings and fly ash in concrete

  • Sunil, B.M.;Manjunatha, L.S.;Ravi, Lolitha;Yaragal, Subhash C.
    • Advances in concrete construction
    • /
    • v.3 no.1
    • /
    • pp.55-69
    • /
    • 2015
  • Tailing Material (TM) and Fly Ash (FA) are obtained as waste products from the mining and thermal industries. Studies were carried out to explore the possibility of utilizing TM as a part replacement to fine aggregate and FA as a part replacement to cement, in concrete mixes. The effect of replacing fine aggregate by TM and cement by FA on the standard sized specimen for compressive strength, split tensile strength, and flexural strengths are evaluated in this study. The concrete mix of M40 grade was adopted with water cement ratio equal to 0.40. Concrete mix with 35% TM and 65% natural sand (TM35/S65) has shown superior performance in strength as against (TM0/S100, TM30/S70, TM40/S60, TM50/S50, and TM60/S40). For this composition, studies were performed to propose the optimal replacement of Ordinary Portland Cement (OPC) by FA (Replacement levels studied were 20%, 30%, 40% and 50%). Replacement level of 20% OPC by FA, has shown about 0-5% more compressive strength as against the control mix, for both 28 day and 56 days of water curing. Interestingly results of split tensile and flexural strengths for 20% OPC replaced by FA, have shown strengths equal to that of no replacement (control mix).

A Case Study of Simulation-based Feasibility Analysis of Replacement of Inspection Equipment for Switchboards (시뮬레이션 기반 배전반 검사장비 교체의 타당성 분석에 관한 사례연구)

  • Han, Young Jin;Yi, Do Yoon;Hong, Jun Pyo;Joo, Sung Ho;Kim, Gi Min;Park, Jaehun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.1
    • /
    • pp.83-90
    • /
    • 2022
  • This study deals with replacement analysis of deteriorated equipment for improving productivity of production system. Frequent breakdown of the deteriorated equipment causes a situation that reduces productivity such as low product quality, process delay, and repair cost. However, the replacement of new equipment will be required a high initial investment cost, so it is important to analysis the economic feasibility. Therefore, we analyze the effect of the production system due to the aging effect of the equipment and the feasibility of equipment replacement based on the economic analysis. The process flow, working time, logistics movement, etc. are analyzed in order to build the simulation modeling for a ship and land switchboard production system. Using numerical examples, the economic feasibility analysis of equipment replacement through replacement of existing deteriorated equipment and additional arrangement of new facilities is performed.

A New Cache Replacement Policy for Improving Last Level Cache Performance (라스트 레벨 캐쉬 성능 향상을 위한 캐쉬 교체 기법 연구)

  • Do, Cong Thuan;Son, Dong Oh;Kim, Jong Myon;Kim, Cheol Hong
    • Journal of KIISE
    • /
    • v.41 no.11
    • /
    • pp.871-877
    • /
    • 2014
  • Cache replacement algorithms have been developed in order to reduce miss counts. In modern processors, the performance gap between the processor and main memory has been increasing, creating a more important role for cache replacement policies. The Least Recently Used (LRU) policy is one of the most common policies used in modern processors. However, recent research has shown that the performance gap between the LRU and the theoretical optimal replacement algorithm (OPT) is large. Although LRU replacement has been proven to be adequate over and over again, the OPT/LRU performance gap is continuously widening as the cache associativity becomes large. In this study, we observed that there is a potential chance to improve cache performance based on existing LRU mechanisms. We propose a method that enhances the performance of the LRU replacement algorithm based on the access proportion among the lines in a cache set during a period of two successive replacement actions that make the final replacement action. Our experimental results reveals that the proposed method reduced the average miss rate of the baseline 512KB L2 cache by 15 percent when compared to conventional LRU. In addition, the performance of the processor that applied our proposed cache replacement policy improved by 4.7 percent over LRU, on average.