• Title/Summary/Keyword: Repetition pulse

Search Result 367, Processing Time 0.026 seconds

Performance Analysis of Noncoherent OOK UWB Transceiver for LR-WPAN (저속 WPAN용 비동기 OOK 방식 UWB 송수신기 성능 분석)

  • Ki Myoungoh;Choi Sungsoo;Oh Hui-Myoung;Kim Kwan-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.11A
    • /
    • pp.1027-1034
    • /
    • 2005
  • IEEE802.15.4a, which is started to realize the PHY layer including high precision ranging/positioning and low data rate communication functions, requires a simple and low power consumable transceiver architecture. To satisfy this requirements, the simple noncoherent on-off keying (OOK) UWB transceiver with the parallel energy window banks (PEWB) giving high precision signal processing interface is proposed. The flexibility of the proposed system in multipath fading channel environments is acquired with the pulse and bit repetition method. To analyze the bit error rate (BER) performance of this proposed system, a noise model in receiver is derived with commonly used random variable distribution, chi-square. BER of $10^{-5}$ under the line-of-sight (LOS) residential channel is achieved with the integration time of 32 ns and signal to noise ratio (SNR) of 15.3 dB. For the non-line-of-sight (NLOS) outdoor channel, the integration time of 72 ns and SNR of 16.2 dB are needed. The integrated energy to total received energy (IRR) for the best BER performance is about $86\%$.

Absorption Spectra of Standard Gases for Wavelength Reference in C-band using a Supercontinuum Source Based on a Mode-locked Cr4+:YAG Laser (모드 잠금 Cr4+:YAG 레이저로부터 발생된 초 광대역 광원을 이용한 광통신 파장 영역의 표준 가스의 흡수스펙트럼)

  • Lee, Jong-Min;Jeon, Min-Yong;Ryu, Han-Young;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.54-59
    • /
    • 2008
  • We report on the measurements of absorption spectra from acetylene ($^{12}C_2H_2$) and hydrogen cyanide ($H^{13}C^{14}N$) for wavelength reference in the C-band (conventional band) region using a supercontinuum optical source generated from a mode-locked $Cr^{4+}$:YAG laser. The center wavelength of the mode-locked $Cr^{4+}$:YAG laser was 1510 nm and the pulse duration was 75 fs at 100 MHz repetition rate. The supercontinuum source achieved a flatness of ${\pm}5dB$ over a wavelength range of more than 400 nm, using a 20 m long photonic crystal fiber. The measured absorption spectra from acetylene ($^{12}C_2H_2$) and hydrogen cyanide ($H^{13}C^{14}N$) had more than 50 lines and were analyzed for wavelength standardization.

Generation of Femtosecond Pulses in a Passively Mode-Locked 100 MHz Cr4+:YAG Laser (수동 모드 잠금된 100 MHz Cr4+:YAG 레이저에서의 펨토초 펄스 발생)

  • Cho, Won-Bae;Rotermund Fabian;Kim, Jong-Doo;Jeon, Min-Yong;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.535-541
    • /
    • 2005
  • We report on the development of a passively mode-locked near-infrared femtosecond laser with Cr:YAG crystal that operates near room temperature. The laser wavelength could easily be tuned by using only the internal prism pair over 110 nm from 1400 nm to 1510 nm in cw and over about 30 nm in mode-locked operation, respectively Maximum cw output powers of 810 mW were obtained with $1.5 \%$ output coupler for absorbed pump powers of 7.6 W. For compensation of the internal group velocity dispersion, an IR graded prism pair was used. The Cr:YAG laser delivered nearly Fourier-transform limited pulses with a pulse duration as short as 64 fs at 100 MHz repetition rate. In the mode-locked regime, the laser was operating at 1510 nm with a spectral bandwidth of 44 nm. In order to avoid unstable mode-locking and power instabilities, self-built tubes were inserted into the beam path in the resonator and purged with N2 gas. Finally, output powers of the Cr:YAG laser were optimized to 250 mW fer long time stable mode-locked operation.

Effects of Anticancer Drug Delivery based on Microbubble and Microbubble-Nanoparticle Complex using Low-Intensity Focused Ultrasound in Breast Cancer Animal Model (유방암 동물모델에서의 저강도 집속초음파를 이용한 마이크로버블 및 마이크로버블-나노물질 복합체 기반 항암제 전달 효율 검증)

  • Baek, Hee Gyu;Ha, Shin-Woo;Huh, Hyungkyu;Jung, Byeongjin;Han, Mun;Moon, Hyungwon;Kim, Sangkyun;Lee, Hak Jong;Park, Juyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.39-47
    • /
    • 2019
  • Ultrasound sonication along with microbubble (MB) could enhance drug delivery to promote the absorption of anticancer drugs into cancers in a noninvasive and targeted manners. In this study, we verify the acute drug delivery enhancement (within an hour) of two representative focused ultrasound driven drug delivery enhancement methods (MB and Doxorubicin-coated Nanoparticle complex (MB-NP) based). Experiments were conducted using in vivo mouse model with MDA-MB-231 breast cancer cell line. Ultrasound generated by single-element 1 MHz focused ultrasound transducer was delivered in pulsed sonication consisted of 0.125 msec bursts at a pulse repetition frequency of 2 Hz for 20 seconds without a significant increase in local temperature (less than $0.1^{\circ}C$) or hemorrhage. Doxorubicin concentrations in tumors were improved by 1.97 times in the case of MB-NP, and 1.98 times by using Doxorubicin and MB separately. These results indicate anticancer drug delivery based on MB and MB-NP can significantly improve the effect of anticancer drugs delivered to tumors in a short time period by using low-intensity focused ultrasound.

EFFECTS OF ND:YAG LASER IRRADIATION AND FLUORIDE APPLICATION ON REMINERALIZATION OF THE ENAMEL (Nd:YAG 레이저 조사와 불화물 도포가 탈회법랑질의 재광화에 미치는 영향)

  • Cho, Hyun;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.381-390
    • /
    • 2004
  • The purpose of this in vitro study was to investigate the effects of Nd:YAG laser irradiation and fluorides on acid drink demineralized enamel. The materials were 30 freshly extracted permanent premolars with intact smooth enamel surfaces. They were demineralized with Coca-cola at $37^{\circ}C$ for 12hours and then irradiated by Nd:YAG laser with 6W power, $50mJ/cm^2$ energy density, and 20Hz pulse repetition. After laser irradiation, teeth were treated by three kinds of fluorides; (1)0.05% NaF fluoride solution (2)1.23% APF gel and (3)0.1%F fluoride varnish, microhardness(VHN) and Diagnodent scores were measured and the surfaces of each treated specimens were also observed with SEM under 1500 magnification. The results were as follows: 1. In the change of microhardness(VHN), it decreased to 34.68% from the initial micrhardness, increased to 78.37% after laser irradiation and increased to 82.62% after fluoride treatment, there were significant differences except when it was irradiated and treated with fluoride(P<0.05). 2. In the change of Diagnodent scores, it was decreased to 28.08% from the initial scores after demineralization, and then increased to 59.81% after laser irradiation, and increased to 82.17% after fluoride treatment. Scores were different significantly between the scores of initial, demineralization, laser irradiation and fluoride treatment(P<0.05). All the scores were not different significantly between fluoride types. 3. SEM observation showed that the lased enamel surfaces after demineralization were thermally degenerated and showed molten lava-like appearance and crater with cracks and many microholes.

  • PDF

EFFECT OF LASER IRRADIATION AND FLUORIDE APPLICATION ON REMINERALIZATION OF ERODED PRIMARY DENIAL ENAMEL (침식된 유치 법랑질에 대한 레이저 조사 및 불소도포의 재광화 효과)

  • Yang, Young-Sook;Kim, Dae-Eup;Ra, Ji-Young;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.262-268
    • /
    • 2006
  • The purpose of this in vitro study was to evaluate the remineralizing effects of Nd : YAG laser irradiation and fluorides application on primary tooth enamel eroded by acidic drink. The materials were 30 sound primary teeth with intact smooth enamel surfaces. They were demineralized with Coca-cola at $37^{\circ}C$ for 12 hours and then irradiated by Nd: YAG laser with 6W power, $50mJ/cm^2$ energy density. and 20Hz pulse repetition. After laser irradiation, teeth were treated by three kinds of fluorides : (1) 0.05% NaF solution, (2) 1.23% APF gel and (3) 0.1% fluoride varnish. Diagnodent scores and microhardness (VHN) were measured before and after the each treatment. The results were as follows: 1. Diagnodent scores decreased to 23.51% from the initial after demineralization, and then increased to 37.37% after laser irradiation, and to 51.34% after fluoride treatment. There were significant differences between the total scores of initial, demineralization, laser irradiation and fluoride treatment (P<0.05). There was no significant difference between scores after fluoride treatment according to fluoride types. 2. Microhardness(VHN) decreased to 33.58% from the initial after demineralization and then increased to 43.99% after laser irradiation, and to 51.38% after fluoride treatment. There were significant differences between the total scores of initial, demineralization, laser irradiation and fluoride treatment (P<0.05). There was no significant difference between scores after fluoride treatment according to fluoride types.

  • PDF

CUTTING EFFICACY OF Er:YAG LASER AND CONVENTIONAL BUR IN DECIDUOUS AND PERMANENT TEETH (Er:YAG laser와 Conventional bur의 유치와 영구치 치아삭제효과 비교)

  • Park, In-Cheon;Lee, Chang-Seop;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.272-285
    • /
    • 2003
  • This study was conducted to observe the microscopic structures of cavities formed after ablation of primary teeth, permanent teeth, enamel and dentin in using a bur and cavities formed after ablation using laser and the following results were obtained after comparing the effects of ablation. Using a #330 bur and Er:YAG laser irradiated at 150 mJ, 200 mJ, 250 mJ and 300 mJ all at the frequency of 5 Hz, 1 mm enamel and dentin samples were ablated and the ablation time was measured. In order to measure the surfaces ablated, 5 each of primary teeth and permanent teeth were ablated using a #330 bur and Er:YAG laser at 150 mJ, 200 mJ, 250 mJ and 300 mJ for 1 sec and the cross section and vertical section were observed. The following results were obtained : 1. Cutting time of Er:YAG laser was longer than that of conventinal high-speed bur regardless of teeth type. 2. Cutting on enamel, Cutting time of conventional high-speed bur in deciduous teeth was longer than in permanent teeth(P<0.05). But Er:YAG laser was not showed any difference between the deciduous and permanent teeth(P>0.05). 3. Cutting on dentin, Cutting time of conventional high-speed bur in permanent teeth was longer than deciduous teeth. Er:YAG laser of 150 mJ, 5 Hz in permanent teeth was longer than in deciduous teeth(p<0.05). But laser of other power did not showed mean difference. 4. The cavity surface treated with the convetional high-speed bur revealed a relatively flat appearance, almost covered with a debris-like smear layer. Cavity wall showed striped appearance because of blade of bur. 5. The cavity surface treated by the Er:YAG laser system was irregular or rough surface with the absence charring, carbonization, or cracking of the dentin. In addition, there was an absence of a smear layer. Cavity floor was round and relatively smooth. According to these results, cutting time of Er:YAG laser was almostly same in permanent and deciduous teeth, but more effective in dentin than enamel. Cutting the sample, Er:YAG laser was needed more time than conventional bur. But SEM findings suggested that laser device produced favorable surface characteristic(i.e, no smear layer, irregular surface, cracking).

  • PDF