• Title/Summary/Keyword: Repeated measurement data

Search Result 222, Processing Time 0.034 seconds

A Study of Correlation between Pulse-Respiration Ratio and Characteristics of Thermal Temperature (체표온도특성(體表溫度特性)과 맥율(脈率)의 상관성(相關性) 연구(硏究))

  • Lee, Hyuk-Jae;Park, Young-Jae;Park, Young-Bae;Oh, Hwan-Sup
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.103-130
    • /
    • 2008
  • Background: For standardizing of Han-Yeol [寒熱], which is a kind of diagnosis method in oriental medicine, it is necessary to investigate into relationship of symptoms and signs representative of Han-Yeol [寒熱] to the biofunctional medical signals; thermal temperature by Thermography, Pulse-Respiration Ratio and so on. By correlation analysis of these data items acquired from patients, it could be provides the fundamental data for standardizing of Han-Yeol [寒熱]. Objectives: We performed this study to check the characteristics of thermal temperature with Han-Yeol [寒熱] statue by pulse-respiration ratio. Methods: We selected nine regions around acupoints including Yin dang[印堂], Sugu[水溝, GV26], Ch'ondol[天突, CV22], Chonjung[CV17], Chung-wan[中脘, CV12], Chonchu[天樞 S25], No-gung[勞官, P8], and calculated based on the utility of R.O.I.(Region of Integer) by IR-2000 these points temperature from 68 subjects. In practicing pulse-respiration ratio over 4.0 means the statues of Yeol [熱], pulse-respiration ratio below 4.0 means the statues of Han [寒]. To optimum conditions thermal temperature, which are not effected by internal and external variables, we studied preceding research. The results shows that optimal time period is 20minutes after undressed and the optimal region is the region around acupoints including Sugu [水溝, GV26]. Based on a preceding research results, we analyzed these data by Paired T-test between GV26 Region and 8-Thermography Regions and two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio. Results: 1. In applying of two-way repeated ANOVA with thermography$({\Delta}T)$ and Han-Yeol [寒熱] statue by pulse-respiration ratio, Sugu [水溝穴, GV26] - [印堂穴, HN1], Sugu 水溝, GV26] - Chonjung[CV17], Sugu [水溝, GV26] -Chung-wan[中脘, CV12]had significant differences. 2. In applying of Paired T-test between Sugu [水溝穴, GV26] Region and 8- Thermography Regions, there were significant differences except of Sugu [水溝穴, GV26] -Chondolp[天突, CV22]. 3. In the difference of Sugu [水溝, GV26] -Chung-wan[中脘, CV12], thermal temperature increases a lot in the statues of Yeol [熱], thermal temperature decreases a lot in the statues of Han [寒]. Conclusions: On the analysis of Thermography, we obtain the measurement conditions were considered the individual variations. And it is different that the thermal temperature change on Thermography according to Han-Yeol [寒熱] statue by pulse-respiration ratio.

  • PDF

Repeated Records Animal Model to Estimate Genetic Parameters of Ultrasound Measurement Traits in Hanwoo Cows (반복모형을 이용한 한우 초음파 측정형질의 유전모수추정)

  • Park, Cheol-Hyeon;Koo, Yang-Mo;Kim, Byung-Woo;Sun, Du-Won;Kim, Jung-Il;Song, Chi-Eun;Lee, Ki-Hwan;Lee, Jae-Youn;Jeoung, Yeoung-Ho;Lee, Jung-Gyu
    • Journal of Animal Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.71-75
    • /
    • 2012
  • The present study data were obtained from 36,894 cows in Korea Animal Improvement Association from 2001 to 2009 which was subjected for ultrasound measurements (eye muscle area, back-fat thickness, marbling score) and descent. Repeated record models were carried out using 7,913 of 36,894 of total animal traits. The ultrasound measured traits and performance test data were used to study the chest girth, body condition score, eye muscle area, back-fat thickness and marbling score with genetic correlation and parameters for the ultrasound measured traits using REMLF90 program. Genetic correlation of eye muscle area with back-fat thickness, marbling score and back-fat thickness with marbling score were noticed in repeated records animal model as 0.69, 0.54, and 0.59, whereas in multiple trait animal model method were 0.07, 0.66, and 0.39, respectively. Repeated records of animal models were used as positive correlation of traits. Multiple trait animal models were used as negative correlation of eye muscle area with marbling score. The analysis on repeat records of animal models using ultrasound measurements about Korean cattle showed positive effects for each traits. In comparison differences between the repeat records of animal models and multiple trait animal models was found with higher traits of her, the heritability and repeatability was found higher in repeat records animal models. In light of these assessments, carcass traits by ultrasound measurements are expected to help and improve an accurate analysis of each trait and if the research analysis using repeat records of animal models continue when we estimate genetic ability of these traits.

On the Improvement of Precision in Gravity Surveying and Correction, and a Dense Bouguer Anomaly in and Around the Korean Peninsula (한반도 일원의 중력측정 및 보정의 정밀화와 고밀도 부우게이상)

  • Shin, Young-Hong;Yang, Chul-Soo;Ok, Soo-Suk;Choi, Kwang-Sun
    • Journal of the Korean earth science society
    • /
    • v.24 no.3
    • /
    • pp.205-215
    • /
    • 2003
  • A precise and dense Bouguer anomaly is one of the most important data to improve the knowledge of our environment in the aspect of geophysics and physical geodesy. Besides the precise absolute gravity station net, we should consider two parts; one is to improve the precision in gravity measurement and correction of it, and the other is the density of measurement both in number and distribution. For the precise positioning, we have tested how we could use the GPS properly in gravity measurement, and deduced that the GPS measurement for 5 minutes would be effective when we used DGPS with two geodetic GPS receivers and the baseline was shorter than 40km. In this case we should use a precise geoid model such as PNU95. By applying this method, we are able to reduce the cost, time, and number of surveyors, furthermore we also get the benefit of improving in quality. Two kind of computer programs were developed to correct crossover errors and to calculate terrain effects more precisely. The repeated measurements on the same stations in gravity surveying are helpful not only to correct the drifts of spring but also to approach the results statistically by applying network adjustment. So we can find out the blunders of various causes easily and also able to estimate the quality of the measurements. The recent developments in computer technology, digital elevation data, and precise positioning also stimulate us to improve the Bouguer anomaly by more precise terrain correction. The gravity data of various sources, such as land gravity data (by Choi, NGI, etc.), marine gravity data (by NORI), Bouguer anomaly map of North Korea, Japanese gravity data, altimetry satellite data, and EGM96 geopotential model, were collected and processed to get a precise and dense Bouguer anomaly in and around the Korean Peninsula.

Comparison of Performance of Measuring Method of VIS/NIR Spectroscopic Spectrum to Predict Soluble Solids Content of 'Shingo' Pear (VIS/NIR 스펙트럼 측정모드에 따른 신고 배의 당도 예측성능 비교)

  • Suh, Sang-Ryong;Lee, Kyeong-Hwan;Yu, Seung-Hwa;Yoo, Soo-Nam;Choi, Yeong-Soo
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.130-139
    • /
    • 2011
  • Three modes of VIS/NIR spectroscopic measurement (interactance and two modes of transmission) were compared for their ability to estimate soluble solids content (SSC) of 'Shingo' pear non-destructively. The two transmission modes are named as full- and semi-transmission, where full-transmission stands for passing of light through abdomen of pear and semi-transmission is for transit of light mainly through flesh of pear. For comparison of the modes, prediction models developed from the collected spectroscopic data by the three modes were developed and tested for comparison of their performance. Partial least square regression (PSLR) was used to develop the models and various pre-processing methods were applied to develop models of high accuracy. The experiment was repeated three times with pears produced in different regions. The experiments resulted that selection of pre-processing is very important to attain accurate models, and multiplicative scatter correction (MSC) was selected as a pre-processor of high accuracy for the three modes of spectroscopic measurement in every experiment. Except for MSC, different group of pre-processing methods were selected for the three modes of measurement in every experiment without any tendency to the tested modes of measurement and pears of different produced region. Root-mean-square error of prediction (RMSEP) of prediction models of the three modes of measurement using prepreocessor of MSC were compared for their ability to estimate SSC. The models resulted in ranges of $0.37{\sim}0.57^{\circ}Brix$, $0.65{\sim}0.72^{\circ}Brix$, $0.39{\sim}0.51^{\circ}Brix$ for interactance, full- and semi-transmission, respectively. As shown, modes of semi-transmission and interactance resulted about the same level of prediction accuracy and were noted as modes of high performance to predict SSC.

Development of a Load Measurement System for Vehicles using Tire Pressure System Technology (타이어 공기압 시스템 기술을 사용한 차량의 적재중량 측정 시스템 개발)

  • Park, Jae-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.33-39
    • /
    • 2020
  • In this paper, we propose the design technique of the vehicle's load weight measuring system using tire pressure, which is one of the physical elements of tires. The proposed technique consists of four processes: noise correction by load and vibration, gas flow correction, data mixer and weight conversion. Noise correction by load and vibration eliminates noise that increases the tire's internal pressure due to external shocks and vibrations produced by the vehicle while it is in motion. In the gas flow correction process, the noise of the internal pressure of the tire is increased due to the temperature rise of the ground with respect to the data obtained through the noise correction process due to the load and vibration. In the data mixer process, the load and pressure on the tolerances the empty, median and the full load are classified according to the change in pressure of the tire that is delivered perpendicular to the tire in the event of cargo. In the weight conversion process, weight is expressed by weight through weight conversion algorithms using noise correction results by load and vibration and gas flow correction. The weight conversion algorithm calculates the weight conversion factor, which is the slope of the linear function with respect to the load and pressure change, and converts the weight. In order to evaluate the accuracy of the loading weight measurement system of the vehicle using the tire pneumatic system technique proposed in this paper, we propose the design technique of the vehicle's load weight measuring system using tire pressure, which is one of the physical elements of tires.. Noise correction results by load and vibration and gas flow data correction results showed reliable results. In addition, repeated weight precision test showed better weight accuracy than the standard value of 90% of domestic companies.

Analysis of Abnormal Settlement Aspect of Caisson Breakwater by Incoming Wave Action in Affected Area of Typhoon (태풍영향권 내습파랑에 의한 직립방파제 이상침하 현상분석)

  • Lee, Joong-Koo;Kim, Hyo-Seob;Park, Koo-Yong;Ahn, Ik-Seong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.6
    • /
    • pp.508-517
    • /
    • 2009
  • The real time movement of the caisson was measured when it was open to the waves during breakwater construction. As a result of measurement, no more settlement after the preloading in condition of designed loading was expected but sudden abnormal settlement took place through whole area of the breakwater when waves occurred by typhoon effect. To clarify the reason of this case, wave of the site has been reproduced and the equivalent wave pressure on the caisson was calculated. The numerical analysis of the effect of wave to the ground had been done. Site measurement data is in accordance with the result of numerical analysis.

The Influence of Motor Ability of Elderly on IADL (노인의 운동능력이 IADL에 미치는 영향)

  • Um, Ki-Mai;Yang, Yoon-Kwon
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.821-831
    • /
    • 2001
  • Motor ability were hypothesized to be major factors that may have an influence on IADL(instrumental activities of daily living). The purpose of this study was to investi gate the effect of motor ability of elderly on IADL. This study consisted of forty eight elder male and ninety elder female. The subjects were selected from L, S, Y-institution in kyoung ki do. The average age of elder male and female was 73.81, 71.38 years. The data were analyzed with t-test, repeated measurement, correlation test, regression test, using SPSS PC+ and MINITAB program. The measurement item of motor ability was muscle strength(left, right- grip strength), flexibility(sitting trunk flexion, trunk extension, leg raising while in a standing position), agility(whole body reaction test, standing up), power(sargent jump), balance (stork stand). IADL was measured with Philadelphia Geriatric Center IADL. The result of this study were the following : 1. The factor of significant difference of between elder male and female was muscle strength, flexibility, power but no significant difference was agility, balance. 2. Between IADL of elder male and female was no significant difference. 3. Correlation of IADL and Motor ability of elder male had effect on muscle strength and power, agility. Correlation of Body composition and Motor ability of elder female had effect on muscle strength and power, agility. As a result of this study, optimal motor ability of elder male and female had improved IADL. In addition to, this result of this study, it can suggested the consideration of the Health promotion program for elderly.

  • PDF

Validity Test of Korean Pain Measurement Tool Using Normal Adult Individuals (정상성인에서의 한국어휘를 이용한 통증척도의 타당도 조사)

  • 이은옥;이숙희
    • Journal of Korean Academy of Nursing
    • /
    • v.16 no.2
    • /
    • pp.13-28
    • /
    • 1986
  • The main purpose of th study was to evaluate he validity of Korean Pain Measurement Tool composed of pain terms. The specific purposes of this study were 1. to examine whether pain intensities of pain terms are congruent with those classified in three previous studies. 2. to evaluate the relative intensity of each term by panel of judges. 3. to explore the difference of ranks of pain terms according to the sex, education, and ages. One hundred and sixty normal individuals were selected by 2$\times$2$\times$4 sampling design. Sex (male, female), education (high school, college), and age (20s, 30s, 40s, 50s) were matched. Each individual was asked to rate the ranks of 3~8 pain terms in each subclass. The data measured by ordinal scale were transformed to the interval scale to compare with the pain intensities gained from the previous study. The pain ranks different from previous results were finally rearranged or cancelled through the consultation of 4 panel of judges and sunmed up to 91 pain terms in the scale. As a result, the ranks of pain terms within each of eleven subclasses among the twenty subclasses completely were congruent with the Previous pain ranks, while the ranks of nine subclasses were different from the previous pain ranks. In addition, there was significant relation between sex and pain ranks in skin punctuate pressure pain and cavity pressure. (sp : $\chi$$^2$=5.18 ø=0.26; cp : $\chi$$^2$=5.83 ø=0.24) In conclusion, seven terms from subclasses of inflammatory repeated pain, traction pressure pain, fatigue-related pain, fear-related pain, dull pain, and pulsation. related pain were cancelled. The ranks of four terms in subclasses of incisive Pressure pain and constrictive pressure pain were tentatively rearranged. Ranks of two terms in the tract pain were left as shown in the third study. As a result, six terms must be studied repeatedly for obtaining exact scores from ratio scale.

  • PDF

Accuracy Improvement of Boron Meter Adopting New Fitting Function and Multi-detector

  • Kong, Chidong;Lee, Hyunsuk;Tak, Taewoo;Lee, Deokjung;Kim, Si Hwan;Lyou, Seokjean
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1360-1367
    • /
    • 2016
  • This paper introduces a boron meter with improved accuracy compared with other commercially available boron meters. Its design includes a new fitting function and a multi-detector. In pressurized water reactors (PWRs) in Korea, many boron meters have been used to continuously monitor boron concentration in reactor coolant. However, it is difficult to use the boron meters in practice because the measurement uncertainty is high. For this reason, there has been a strong demand for improvement in their accuracy. In this work, a boron meter evaluation model was developed, and two approaches were considered to improve the boron meter accuracy: the first approach uses a new fitting function and the second approach uses a multi-detector. With the new fitting function, the boron concentration error was decreased from 3.30 ppm to 0.73 ppm. With the multi-detector, the count signals were contaminated with noise such as field measurement data, and analyses were repeated 1,000 times to obtain average and standard deviations of the boron concentration errors. Finally, using the new fitting formulation and multi-detector together, the average error was decreased from 5.95 ppm to 1.83 ppm and its standard deviation was decreased from 0.64 ppm to 0.26 ppm. This result represents a great improvement of the boron meter accuracy.

A Noise-Robust Measuring Algorithm for Small Tubes Based on an Iterative Statistical Method (통계적 반복법에 기반한 노이즈에 강한 소형튜브 측정 알고리즘 개발)

  • Kim, Hyoung-Seok;Naranbaatar, Erdenesuren;Lee, Byung-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.2
    • /
    • pp.175-181
    • /
    • 2011
  • We propose a novel algorithm for measuring the radius of tubes. This proposed algorithm is capable of effectively removing added noise and measuring the radius of tubes within allowable precision. The noise is removed by using a candidate true center that minimizes the standard deviation with respect to the radius. Further, the disconnection in data points resulting from noise removal is solved by using a connection algorithm. The final step of the process is repeated until the value of the standard deviation decreases to a small predefined value. Experiments were performed using circle geometries with added noise and a real tube with complex noise and that is used in the braking units of automobiles. It was concluded that the measurement carried out using the algorithm was accurate within 1.4%, even with 15% added noise.