• Title/Summary/Keyword: Reoperation

Search Result 510, Processing Time 0.029 seconds

Surgical Treatment of Atrioventricular Septal Defect (방실중격결손증의 외과적 치료)

  • 이광숙
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.990-995
    • /
    • 1989
  • Since 1984, 24 patients underwent repair of atrioventricular septal defect. Nineteen had a partial defect and 5 had a complete atrioventricular septal defect. There were 9 men and 15 women, ranging in age from 1 to 50 years [mean age, 13.3 years]. Four patients had a Downs syndrome. Additional congenital heart defects were present in 11 patients. One patient had palliative operation prior to total correction. In partial defects, the primum atrial septal defect was closed with Xenomedica patch and the mitral valve was repaired with simple closure of the septal commissure. Central incompetence from annular dilatation was repaired by a local annuloplasty. In complete defect, the septal defects were closed with two patches except one. Operative mortality was 5% in partial defects and 60% in complete defects and low cardiac output was the commonest etiology. In a mean follow-up period of 27.9 months [range, 4 to 63 months] there were no late death and no instances of late-onset complete heart block. One patient required reoperation [MVR] for residual mitral regurgitation. The majority of patients were asymptomatic and mean postop. NYHA functional class was 1.2.

  • PDF

Traumatic Aneurysm of Descending Thoracic Aorta -A Case Report- (외상성 하행 흉부 대동맥류 -치험 1 례 보고-)

  • 임승현
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.1042-1046
    • /
    • 1994
  • We experienced a case of traumatic aneurysm of descending thoracic aorta by an automobile accident. The patient was 23-year-old-male with a traumatic aortic aneurysm [6x12cm] on the descending thoracic aorta just distal to the origin of the left subclavian artery. Exposure was obtained through a left posterolateral thoracotomy incision in the fourth intercostal space and then partial femoro-femoral cardiopulmonary bypass was established.After aortic cross- clamping, the aneurysmal sac was opened and repaired with interposition of Dacron vascular graft and aortic cross-clamping period lasted for 100 minutes. Postoperative bleeding and vocal cord paralysis were complicated, but bleeding was controlled by reoperation and vocal cord paralysis was improved. Follow up was continued for 14months and postoperative course was uneventful.

  • PDF

Clinical Experience of Carbomedics Valve (CarboMedies 기계판막의 임상적 연구)

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.995-1001
    • /
    • 1994
  • The CarboMedics valve prosthesis is a relatively new. low profile bileaflet prosthesis. During a 6 year period from Aug. 1988 to July 1994. 158 patients had CarboMedics prostheses implanted in the mitral [n=94], aortic [n=25], or aortic and mitral [n=39] in National Medical Center. Hospital mortality was 9.4% and the main cause of death was low output syndrome. Follow up was 96% complete, with 365.4 patient-years and a mean follow up of 30 months [ range 1 to 72 months ] . The overall actuarial 6 year survival rate was 91.61 3.47% and actuarial 6year freedom from all valve related complications was 73.9 7.67%. The linearized incidence of vavle related complications was as follows: thromboembolism 1.37%/patient-year ; valve thrombosis 0.82%/ patient-year ; anticoagulant related hemorrhage 0.85%/patient-year ; perivalvular leakage 0.55%/paitent-year: prosthetic valve endocarditis 0.82%/patient-year ; reoperation 1.37%/patient-year. There were no instances of structural failure. We conclude that the Carbomedics valve has a low rate of complications that further improves the quality of life in patients with heart valve prostheses.

  • PDF

Redo Konno Procedure - A case report - (Konno씨 수술 재수술 -1례 보고-)

  • 구관우;강신광;원태의;김시욱;박상순
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.133-136
    • /
    • 2002
  • A 28 year-old male who had received Konno procedure twelve years ago with 23mmmechanical aortic valve and bovine pericardium with which his small aortic annulus, ventricular septum and right ventricular outflow tract had been enlarged was transferred due to sudden congestive heart failure. There were perforations on aortic and interventricular portion of bovine pericardial patch above and below the aortic valve, respectively, which was calcified and denaturated severely. The perforations seemed to be attributed to the cracks, resulting from mobility of mechanical aortic valvc itself and stiffness of calcified and denaturated bovine patch. We performed a redo Konno procedure applying PTFE patch.

Repair of Paravalvular Leak at Mitral Position after Redo DVR (승모판막 재치환술후 발생한 판막주위 누출 치험 1례)

  • 김경훈;정승혁
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.428-431
    • /
    • 1997
  • We experienced a casts of prosthetic mitral paravalvular leak after redo DVR. As far as nonstructural dysfunction is concerned, the prosthetic paravalvular leak is not the result of prosthetic valve endocarditis, but is due to technical difficulties at the time of operation, either residual calcification or poor native tissue. Occasionally paravalvular leaks, particulary around mitral prostheses, may be silent. Paravalvular leaks are usually repaired when there is significant anemia or hemodynamic compromise. At reoperation, some of theses leaks can be repaired simply by patch losure around the paravalvular leak without placing additional suture or explanting the valve.

  • PDF

Surgical Treatment of Atrioventricular Septal Defect (방실중격결손증의 외과적 치료)

  • Yun, Yeong-Cheol;Lee, Sin-Yeong;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.26 no.12
    • /
    • pp.904-908
    • /
    • 1993
  • Twelve patients had undergone repair of atrioventricular septal defects. Age at operation ranged from 2.4 years to 17 years[mean, 8.25 years]. Five patients were male and seven were female. Three patients had complete atrioventricular septal defect[Rastelli type A] associated with Down`s syndrome. One of the three patient with complete atrioventricular septal defect had tetralogy of Fallot. Three patients had the intermediate form and seven patients had the partial form. The primum atrial septal defect was closed with pericardial patch. The atrioventricular valve septal commissure[mitral cleft] was closed with pledgeted sutures. Three complete atrioventricular septal defect were undergone by two-patch technique. A crescent-shaped Dacron patch was used to occlude the ventricular septal defect. One patient of partial form was sudden death 5 days postoperatively. There were no another complications after surgery. One patient underwent reoperation for opened mitral cleft 2.5 years postoperatively. New York Heart Association functional class of patients was improved postoperatively.

  • PDF

Fibrous tissue overgrowth on Hancock mitral xenograft: case report (승모판막대치술후 발생한 섬유성 조직의 과성장 1례 보)

  • 유병하
    • Journal of Chest Surgery
    • /
    • v.16 no.4
    • /
    • pp.506-510
    • /
    • 1983
  • Valve dysfunction can be caused by thickening or contraction of a fibrous sheath covering a cusp of a porcine bioprosthesis, but this is uncommon. This complication appears to more frequent in other bioprostheses, such as fascia late valves and homografts, in which fibrous sheaths seems to grow more rapidly. rapidly. Thus the slow and limited growth of fibrous sheath in porcine bioprostheses is advantageous in this respect. Recently, we experienced a case of valve dysfunction caused by fibrous tissue overgrowth on Hancock mitral xenograft in 45 year old female. 3.5 years ago, the patient was received valve replacement due to mitral stenoinsufficiency. But since 2.5 years elapsed after operation, she has complained of generalized edema and dyspnea, and their symptoms were aggravated progressively. So reoperation was performed under the diagnosis as valve dysfunction of mitral xenograft and newly developed tricuspid insufficiency. Her postoperative courses were good.

  • PDF

Replacement of the Prosthetic Heart Valves -Clinical analysis of 12 cases- (인공심장판막의 재치환술)

  • 김덕실;전상훈
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.164-170
    • /
    • 1996
  • From January 1986 to June 1993, 12 patients Aad required reoperation: 9 had undergone mitral and 3 aortic valve replacement. Five were male and 7 female, and ages ranged from 29 to 61 years. Replacement of the prosthetic heart valve was performed at a mean interval of 98 $\pm$ 1 months after the Hrst operation. In aortic valve replacement patients the mean interval was 115 $\pm$ 2 months and in mitral valve replacement patients 98 $\pm$ 4 months. Primary tissue failure was the most frequent reason of replacement (10 patients) followed by valve thrombosis (1 patient) and prophylactic replacement (1 patient) in order. The most pronounced pathology of the failed prosthetic heart valves seen in the primary tissue failure group was calcification, perforation, shrinkage and tearing of the cusps. There was one early operative death (8.3%) due to intractable low cardiac output and acute renal failure. Eleven early survivors had successful operative results and there was no late death.

  • PDF

Redo-Coronary Artery Bypass due to Progression of the Celiac Axis Stenosis

  • Yeom, Sang-Yoon;Hwang, Ho-Young;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.45 no.4
    • /
    • pp.251-253
    • /
    • 2012
  • We report a redo coronary artery bypass grafting (CABG) in a 55-year-old man. Angina recurred 7 years after the initial surgery. Coronary angiography showed all patent grafts except a faint visualization of the in situ right gastroepiploic artery (RGEA) graft, which was anastomosed to the posterior descending coronary artery, associated with celiac axis stenosis. Redo-CABG was performed at postoperative 10 years because of aggravated angina and decreased perfusion of the inferior wall in the myocardial single photon emission computed tomography. The saphenous vein graft was interposed between the 2 in situ grafts used previously; the right internal thoracic artery and RGEA grafts. Angina was relieved and myocardial perfusion was improved.

Replacement of prosthetic heart valves Report of 5 cases (인공심장판막의 재치환술 5례 보고)

  • 신제균
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.655-662
    • /
    • 1985
  • From January 1985 to July 1985, prosthetic heart valves were replaced in 5 patients at Keimyung University Dongsan Medical Center. The patients included three women and two men ranging in age from 22 to 41 years. Three mitral valve replacements, one aortic valve replacement and one double valve replacement [mitral and aortic valve replacement] were done at the first valve operations. Reoperation were performed 2 to 76 months after the first operations, Prosthetic valve endocarditis occurred in 3 patients, early in one and late in two and primary valve failure occurred in 2 patients. In operative findings, vegetation in prosthetic valve endocarditis and calcification in primary valve failure were found. All except one had relatively successful operative results. One died of early fungal prosthetic valve endocarditis due to relapsed prosthetic valve endocarditis with heart failure and block.

  • PDF