• Title/Summary/Keyword: Removal rate

Search Result 3,850, Processing Time 0.037 seconds

A Study on the Advanced Treatment of Wastewater by Plants (식물을 이용한 오수의 고도처리에 관한 연구)

  • 이용두;김현희
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.75-81
    • /
    • 1999
  • In recent years increasing production and disposal of wastewater have caused an accelerated eutrophication of receiving waters. Therefore, in order to alleviate the detrimental impact of wastewater discharge, there is an increasing demand for removing the main nutrients, nitrogen and phosphorus, as well as the organic content of the waste water prior to disposal. This is effectively achieved by extended conventional treatment technology. However, the working expenses and energy requirements of such advanced treatment systems are rather high. So in a sparsely populated rural community is required development of wastewater treatment system combined with the regional characteristics. In this study, the systems are planted with Reeds and Amaryllis In A.C and estimated purification potential of system. The results obtained are as follows. BOD removal rate is 20% in the early stage, the last removal rate is 35% in A.C process and is 65% in Amaryllis+A.C process and is 50% in Reed+A.C process. T-N removal rate by Amaryllis is average 2.6g/$m^3$ㆍd, T-N removal rate by Reed is average 1.76g/$m^3$ㆍd. T-P removal rate by Amaryllis is average 0.27g/$m^3$ㆍd, T-P removal rate by Reed is average 0.25g/$m^3$ㆍd. BOD removal rate constant with retention time is 1.4494(1/d), T-N removal rate constant is 0.5428(1/d), T-P removal rate constant is 0.5287(1/d).

  • PDF

Effects of Plant on Pollutant Removal Rate n Surface-flow Constructed Wetlands (자유수면형 인공습지에서 식물식재 유무가 처리효율에 미치는 영향)

  • Ham, Jong-Hwa;Kim, Hyung-Joong;Kim, Dong-Hwan;Hong, Dae-Byuk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.85-91
    • /
    • 2011
  • Three different types of wetlands (unplanted wetland, reed planted wetland, cattail planted wetland) were constructed at the mouth of Seokmoon reservoir with 910 $m^2$ each to examine the effects of wetland plant on pollutant removal rate in constructed wetland, and operated for 9 years (2002~2010). Water depth of the wetland was maintained at 0.3~0.5 m, flow rate was about 40~200 $m^3$/day, and retention time was managed at about 1~5 days. There was no difference in removal rate of SS, TN, and TP between reed wetland and cattail wetland. Removal rate of SS and TN in planted wetland with reed and cattail were higher than unplanted wetland, whereas removal rate of TP in unplanted wetland was higher then planted wetland. The monthly variation of removal rate in planted wetlands was high compared with unplanted wetland. From the long term monitoring results, SS and TN removal rates of period3 (2008~2010) were higher than period1 (2002~2004) in planted wetland, whereas TP removal rate was decreased as time goes on. Overall, pollutant removal rate in constructed wetland was more influenced by existence of plants than by plant species. Although constructed wetland is operated long term period, SS, TN, and TP removal rate (SS 90 %, TN 60 %, TP 40 %) can be maintained high values.

Analysis of Temperature Effect on Activated Sludge Process at Cheong-Gye Cheon Sewage Treatment Plant (활성오니공법에 있어서 수온이 처리효율에 미치는 영향에 관한 분석 -청계천 하수종말처리장에 대하여-)

  • 이은경
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.9-20
    • /
    • 1981
  • This study was performed to determine the correlationship between temperature and overall removals of BOD, SS and to demonstrate the effect of temperature on treatment performance. These data for a period from February 1, 1977 to January 31, 1980 were obtained from the Cheong-Gye Cheon Sewage Treatment plant. The results of correlation and stepwise multiple regression analysis were as follows. 1) Secondary effluent BOD and SS showed negative correlationship with water temperature, with correlation coefficient of -0.1710, and -0.1654 respectively. 2) Correlation coefficient of BOD, SS removal rate and water temperature were 0.1823 and 0.0429 respectively. 3) Regresion equation for estimate of BOD removal rate was as follows $\widehat{Y}_1$ (BOD removal rate)=63.9994+0.5442X(water temperature). And BOD removal rate showed non significant change according to the water temperature. 4) Regression equation for estimate of SS removal rate was as follows $\widehat{Y}_2$ (SS removal rate)=61.6881+0.1514X(Water temperature). And SS removal rate showed non significant change according to the water temperature. 5) According to the Stepwise Multiple Regression analysis, water temperature ranked second order in the BOD removal rate estimation and the equation was as follows $\widehat{Y}_1$ (BOD removal rate)=69.7398+0.2665 $X_1$ (Primary effluent BOD)+0.3562 $X_2$ (Water temperature)-0.0122 $X_3(Flow)+4413.271X_4$ (Organic Loading).

  • PDF

Effect of Operating Parameters on the Removal Performance of Copper Ion by Electrodialysis (전기투석을 이용한 구리이온의 제거 시 운전인자의 영향)

  • Jung, Hyo-Sang;Lee, Gangchoon
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.54-60
    • /
    • 2011
  • To evaluate the feasibility of electrodialysis for copper removal from industrial wastewater, the effect of operating parameters on the removal of copper was experimentally estimated. The limiting current density (LCD) linearly increased with the copper concentration and the flow rate. The time when the copper concentration of diluate reaches to 3 mg/L was linearly proportional to initial concentration of diluate, and the concentration of concentrate did not affect the removal rate. Increase in the flow rate gave a positive effect on the removal rate and became insignificant at flow rates greater than 2.4 L/min. The removal rate increased with the applied voltage. From the operation of the electrodialysis module used in this research, the flow rate of 2.4 L/min and the voltage corresponding to the 80~90% of LCD were found be the optimum operating condition for the copper removal from highly concentrated copper solutions.

Performance of Advanced Sewage Treatment Process with Waste Oyster Shell Media in Rural Area (폐굴껍질 담체를 이용한 마을하수고도처리공정의 성능평가)

  • Lim, Bong-Su;Yang, Yan-Hao
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.30-36
    • /
    • 2006
  • This study was carried out to evaluate the performance of Modified Ludzsck Etinger (MLE) process with waste oyster shell media in aerobic tank. Influent flow was 36 L/d and the order of reactor was anoxic, aerobic and sedimentation tank and unit hydraulic retention time was 2 hr, 6 hr and 4 hr, respectively. Sludge recycling rate in sedimentation tank and internal recycling rate were 100%. Media fill rate in aerobic tank was 5%, 10% and 17% and fluid MLSS concentration in aerobic tank was 3000~4000 mg/L. Average TCOD removal rate was 91~93%, TBOD 92~96%, SS 95~96% and when media fill rate was 10% or more, in organic compound removal it could satisfy with wastewater discharge standard. Average total nitrogen removal rate was 70~76% and average total phosphorous removal rate was 58~65%. With media fill rate increasing, total phosphorous average removal rate also increased. For it was that released calcium ion from waste oyster shell reacted with soluble phosphorous. From these experiment results, the MLE process using waste oyster shell as media is a practical method for advanced sewage treatment in rural area.

Removal of miniplates following facial trauma and orthognathic surgery: a 3-year study

  • Shin, Na-Ra;Oh, Ji-Su;Shin, Sang-Hun;Kim, Su-Gwan
    • Oral Biology Research
    • /
    • v.42 no.4
    • /
    • pp.222-227
    • /
    • 2018
  • The purpose of this study was to determine the cause and risk factors of removing bone plateby investigating and analyzing 359 patients who underwent reduction of fracture or orthognathic surgery with bone plate insertion over the past 3 years. Patients were evaluated with respect to age, smoking status, reason for insertion of plates, the numbers of inserted plates, sites of insertion, time between insertion and removal, reasons for removal of plates. The removal rate of bone plates was 33.1%. Of these, 17.0% of patients had clinical symptoms which led to remove plates. The removal rate of men was 29.9% and the rate of women was 39.2%. There were high removal rates from less than 20s (45.8%) and 20s (34.4%) those who are relatively young age group. On the other hand people in their 50s had a removal rate of 27.8% which was higher than those in their 60s with a rate of 20.7%. The removal rate of bone plate inserted into the mandible was 33.5%, and the removal rate of bone plate inserted into the maxilla was 34.7%. The mean period between the insertion and removal of bone plate was 10.9 months. The main reason for the removal of bone plate was the patient's requirement (44.5%). The most common cause of clinical symptoms was infection (22.7%). Infection was manifested within about a year and led to the plate being removed. Therefore, lowering the possibility of infection after surgery could decrease the removal rate of bone plate.

The Effect of Pressure and Platen Speed on the Material Removal Rate of Sapphire Wafer in the CMP Process (CMP 공정에서 압력과 정반속도가 사파이어 웨이퍼 재료제거율에 미치는 영향)

  • Park, Sanghyun;An, Bumsang;Lee, Jongchan
    • Tribology and Lubricants
    • /
    • v.32 no.2
    • /
    • pp.67-71
    • /
    • 2016
  • This study investigates the characteristics of the sapphire wafer chemical mechanical polishing (CMP) process. The material removal rate is one of the most important factors since it has a significant impact on the production efficiency of a sapphire wafer. Some of the factors affecting the material removal rate include the pressure, platen speed and slurry. Among the factors affecting the CMP process, we analyzed the trends in the material removal rate and surface roughness, which are mechanical factors corresponding to both the pressure and platen speed, were analyzed. We also analyzed the increase in the material removal rate, which is proportional to the pressure and platen speed, using the Preston equation. In the experiment, after polishing a 4-inch sapphire wafer with increasing pressure and platen speed, we confirmed the material removal rate via thickness measurements. Further, surface roughness measurements of the sapphire wafer were performed using atomic force microscopy (AFM) equipment. Using the measurement results, we analyzed the trends in the surface roughness with the increase in material removal rate. In addition, the experimental results, confirmed that the material removal rate increases in proportion to the pressure and platen speed. However, the results showed no association between the material removal rate and surface roughness. The surface roughness after the CMP process showed a largely consistent trend. This study demonstrates the possibility to improve the production efficiency of sapphire wafer while maintaining stable quality via mechanical factors associated with the CMP process.

Performance of Rotating Biological Contactor (RBC) under Different Hydraulic Loading Rates and Rotational Speeds on Ammonia Removal in a Recirculating System

  • Son Maeng Hyun;Jeon Im Gi;Jo Jae-Yoon;Moon HaeYoung
    • Fisheries and Aquatic Sciences
    • /
    • v.2 no.1
    • /
    • pp.52-57
    • /
    • 1999
  • Air-drived rotating biological contactor (RBC) system, which is effective method in filtering performance, was tested for the nitrification capacity in a recirculating system. At ammonia concentrations between 0.029 and 0.528 mg/l, the effect of ammonia loading rate on ammonia removal rate at three different hydraulic loading rates could be defined by the following first­order regression models: Hydraulic loading rate of $14.8 m^3/m^3/day:\;y=39.2\times+3.4 (r^2=0.9137)$, Hydraulic loading rate of $26.5 m^3/m^3/day: y=53.3\times+4.0 (r^2=0.8686)$, Hydraulic loading rate of $37.3 m^3/m^3/day: y=58.4\times+4.2 (r^2=0.7755)$, where, $\times$ is ammonia loading rate (mg/l), y is ammonia removal rate $(g/m^3/day)$, The equations showed the optimal ammonia removal rate at the hydraulic loading rate of $26.5m^3/m^3/day$. Below the ammonia concentration of 2.72 mg/l, first-order regression models between ammonia loading rate and ammonia removal rate at three different rates of speed are defined as follows: Rotational speed of $0.75 rpm: y=28.5\times+4.7 (r^2=0.9143)$, Rotational speed of $1.0 rpm: y=33.6\times+8.4 (r^2=0.9534)$, Rotational speed of $2.0 rpm: y=28.9\times+3.6 (r^2=0.9488)$, where, x is ammonia loading rate (mg/l), y is ammonia removal rate $(g/m^3day)$. The equations show the ammonia removal rate at the rotational speed of 1.0 rpm is significantly higher than that at the rotational speed of either 0.75 rpm or 2.0 rpm (P<0.05).

  • PDF

Removal of Organics and Nirtogen in Wastewater Using 2 Stage A/O(RBC) Process (RBC 반응조를 이용한 2단 A/O 공정에서 유기물질 및 질소제거)

  • 최명섭;손인식
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.3
    • /
    • pp.59-64
    • /
    • 2003
  • This study was conducted to investigate anoxic-RBC-anoxic-RBC process and its application to remove biologically organics and nitrogen. BOD and total-nitrogen(T-N) removal efficiencies were decreased as volumetric loading rate increased. But, the removal efficiency changes of T-N were little, as compared to BOD. Increase of internal recycle rate had few affect of BOD and T-N removal rates. Also, influent allocation(to 2nd anoxic reactor) had few affect of BOD removal efficiency rate. However, when the influent allocation rate was 30%, T-N removal efficiency was increased to 84.1 %. BOD/N ratio applied to 2nd anoxic reactor was increased to range of 3.65-4.37 as influent allocation rate increased to range 20∼35%. But, it might also cause adverse effect such as decrease of denitrification rate in excessive influent allocation rate.

Removal Characteristics of Benzene in Dielectric Barrier Discharge Process

  • Chung, Jae-Woo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E1
    • /
    • pp.13-20
    • /
    • 2002
  • The electrical and chemical properties of the dielectric barrier discharge (DBD) process for the benzene removal were investigated. The benzene removal was initiated with the applied voltage higher than the discharge onset value. The removal efficiency over 95 % was obtained at approximately 1.6 kJ lite $r^{r-1}$ of the electrical energy density. The increase of the inlet concentration decreased the removal efficiency. However, the benzene decomposition rate increased with the inlet concentration . While the increase of the gas retention time enhanced the removal efficiency, the decomposition rate decreased. Identification of the optimum condition between the decomposition rate and the removal efficiency is required for field applications of the DBD process.s.