• Title/Summary/Keyword: Removal of scale

검색결과 1,230건 처리시간 0.028초

바이오가스 플랜트 처리수의 고농도 질소 제거 (Pilot-scale Study on Nitrogen Removal of Effluent from Biogas Plant)

  • 유성인;유영섭;이용세;박현수;유희찬
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.175.1-175.1
    • /
    • 2011
  • A rotating activated bacillus contactor (RABC) process with a series of aerobic reactors was tested in pilot scale to treat digested liquid from an anaerobic digester treating swine wastewater and sewage sludge. The influent (digested liquid) for the RABC process showed C/N ratios less than 2 as a typical feature of effluent from anaerobic digesters. The pilot process, which consists of three 3 RABC reactors, four aerobic tanks and a sedimentation tank, was operated for 210 days with a hydraulic retention time of 20 days without pH and temperature control. Since the Bacillus-enriched aerobic reactors shows high efficiencies of nitrogen removal at low DO levels less than 1.0 mg/L, they were operated at reduced aeration intensities. With relatively low concentrations of organics in comparison with nitrogen concentrations, the RABC process tested in this study showed stable and high nitrogen and organics removal efficiencies over 80%. The nitrogen removal process tested in this study was proven to be an effective and operation-cost saving (lower aeration) method to remove nitrogen without adding external carbon sources to meet the optimum C/N ratio.

  • PDF

대청호 원수내 냄새 및 THM 제거방안 연구 (Removal of Odor and THM from the Raw Water of Daecheong Dam)

  • 전항배;윤기식
    • 한국수자원학회논문집
    • /
    • 제30권3호
    • /
    • pp.235-245
    • /
    • 1997
  • 대청호 원수를 취수하여 정수하는 대청수도에서 이취미를 제거하고 THM(Trihalomethanes) 발생량을 줄이기 위하여 기존 표준정수공정에 오존과 활성탄여과공정을 추가한 pilot plant 실험을 수행하였다. pilot 실험결과 표준정수공정에서 DOC(dissolved organic carbon)는 약 25% 제거되었으나, 오존공정에서는 거의 제거되지 않았고, 30일이 지난 후 GAC(granular activated carbon)에서는 약 75%까지 제거되는 것으로 나타났다. 표준정수공정에서 이취미는 약 30%, 오존산화공정에서 약 60%정도 제거되었고, 활성탄여과에서 대부분 제거되었으나, Column 1과 2에서는 DOC와 같이 이취미물질도 파과(breakthrough) 되는 것으로 나타났다. 전염소처리 대신에 중1, 2염소처리를 도입할 경우 전염소처리와 비교하여 약 25%정도의 THM발생량이 감소하였으며, 후염소처리만할 경우 약 30%까지 감소하는 것으로 나타났다.

  • PDF

소규모 쓰레기 매립장 침출수의 효율적인 처리 방안에 관한 연구 (Effective Treatment System for the Leachate from a Small-Scale Municipal Waste Landfill)

  • 조영하;권재현
    • 한국환경보건학회지
    • /
    • 제28권1호
    • /
    • pp.51-65
    • /
    • 2002
  • This study was carried out to apply some basic physical and chemical treatment options including Fenton's oxidation, and to evaluate the performances and the characteristics of organic and nitrogen removal using lab-scale biological treatment system such as complete-mixing activated sludge and sequencing batch reactor(SBR) processes for the treatment of leachate from a municipal waste landfill in Gyeongnam province. The results were as follows: Chemical coagulation experiments using aluminium sulfate, ferrous sulfate and ferric chloride resulted in leachate CO $D_{Cr}$ removal of 32%, 23% and 21 % with optimum reaction dose ranges of 10,000~15,000 mg/$\ell$, 1,000 mg/$\ell$ and 500~2,000 mg/$\ell$, respectively. Fenton's oxidation required the optimum conditions including pH 3.5, 6 hours of reaction time, and hydrogen peroxide and ferrous sulfate concentrations of 2,000 ~ 3,000 mg/$\ell$ each with 1:1 weight ratio to remove more than 50% of COD in the leachate containing CO $D_{Cr}$ between 2,000 ~ 3,000 mg/$\ell$. Air-stripping achieved to remove more than 97% of N $H_3$-N in the leachate in spite of requiring high cost of chemicals and extensive stripping time, and, however, zeolite treatment removing 94% of N $H_3$-N showed high selectivity to N $H^{+}$ ion and much faster removal rate than air-stripping. The result from lab-scale experiment using a complete-mixing activated sludge process showed that biological treatability tended to increase more or less as HRT increased or F/M ratio decreased, and, however, COD removal efficiency was very poor by showing only 36% at HRT of 29 days. While COD removal was achieved more during Fenton's oxidation as compared to alum treatment for the landfill leachate, the ratio of BOD/COD after Fenton's oxidation considerably increased, and the consecutive activated sludge process significantly reduced organic strength to remove 50% of CO $D_{Cr}$ and 95% of BO $D_{5}$ . The SBR process was generally more capable of removing organics and nitrogen in the leachate than complete-mixing activated sludge process to achieve 74% removal of influent CO $D_{Cr}$ , 98% of BO $D_{5}$ and especially 99% of N $H_3$-N. However, organic removal rates of the SBR processes pre-treated with air-stripping and with zeolite were not much different with those without pre-treatment, and the SBR process treated with powdered activated carbon showed a little higher rate of CO $D_{Cr}$ removal than the process without any treatment. In conclusion, the biological treatment process using SBR proved to be the most applicable for the treatment of organic contents and nitrogen simultaneously and effectively in the landfill leachate.e.

HEAT REMOVAL TEST USING A HALF SCALE STORAGE CASK

  • Bang, K.S.;Lee, J.C.;Seo, K.S.;Cho, C.H.;Lee, S.J.;Kim, J.M.
    • Nuclear Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.143-148
    • /
    • 2007
  • Spent nuclear fuel generated at nuclear power plants must be safely stored during interim storage periods. A dry storage cask to safely store the spent nuclear fuel should be able to adequately emit the decay heat from the spent nuclear fuel. Therefore, heat removal tests using a half scale dry storage cask have been performed to estimate the heat transfer characteristics of a dry storage cask under normal, off-normal, and accident conditions. In the normal condition, the heat transfer rate to an ambient atmosphere by convective air through a passive heat removal system reached 83%. Accordingly, the passive heat removal system is designed well and works adequately. In the off-normal condition, the influence of a half blockage in the inlet on the temperature appears minimal. In the accident condition, the temperature rose for 12 hours after the accident, but the temperature rise steadied after 36 hours.

남조류 제거를 위한 선회식 가압부상장치 현장 적용에 관한 연구 (A Study on Pilot Scale Cyclonic-DAF Reactor for Cyanobacteria Removal)

  • 오홍석;강선홍;남숙현;김은주;구재욱;황태문
    • 한국환경복원기술학회지
    • /
    • 제21권5호
    • /
    • pp.17-28
    • /
    • 2018
  • Cyclonic-dissolved air flotation(Cyclonic-DAF), an advanced form of pressure flotation, applies a structure that enables the forming of twirling flows. This in turn allows for suspended matter to adhere to microbubbles and float to the surface of a treatment tank during the process of intake water flowing through a float separation tank. This study conducted a lab-scale test and pursued geometrical modeling using computational fluid dynamics(CFD) to establish a pilot scale design. Based on the design parameters found through the above process, a pilot cyclonic-DAF system($10m^3/hr$) for removing algae was created. Upon developing the pilot-scale cyclonic-DAF system, a type of algae coagulant(R-119) was applied as the coagulant to the system for field testing through which the removal rates of chlorophyll-a and cyanobacteria were evaluated. The chlorophyll-a and harmful cyanobacteria of the raw water at region B, the field-test site, were found to be $177.9mg/m^3$ and 652,500cells/mL respectively. Treated waters applied with 60mg/L and 100mg/L of algae coagulant presented removal efficiencies of approximately 95% and 97%, respectively. The cyanobacteria cell number of the treated waters applied with 60mg/L and 100mg/L of algae coagulant both that were equal to or less than 1,000cells/mL and were below attention level criteria for the issuance of algae boundary.

안면신경초종 수술 후유증 환자에 대한 침 및 침전기 자극술의 효과 (Case Study : Effects of Acupuncture and Electro-acupuncture on a Patient with Sequelae Caused by Removal of Facial Schwannoma)

  • 이상영;왕공덕;설재욱;강휘중
    • 동의생리병리학회지
    • /
    • 제27권3호
    • /
    • pp.327-330
    • /
    • 2013
  • The purpose of this study is to report a clinical progress of treatment of sequelae caused by removal of facial schwannoma through Korean medicine. A patient was diagnosed with facial schwannoma by MRI on 4th June 2012 in local university hospital, he had right facial palsy, auditory hypersensitivity, dizziness after removal of facial schwannoma. Between 25th July 2012 and 26th January 2013, he was treated with acupuncture, cupping, electro-acupuncture every week and observed by House-Brackmann facial nerve grading system(H-B scale) and MoReSS every month. He had 29 times treatments. At the first of treatment, his state was Grade IV (H-B scale), 4/8(facial nerve grading), 10 points during action 7 points during rest(MoReSS) and he had severe facial palsy, ill-acrimation, auditory hypersensitivity. At the middle of treatment, October 2012, symptoms improved. State was Grade III (H-B scale), 5/8(facial nerve grading), 7 points during action 3 points during rest(MoReSS). Severe facial palsy improved ; Forehead creasing and union motor function recovered, he was able to close his eyes so ill-acrimation improved. At the end of treatment, January 2012, state was Grade II (H-B scale), 7.5/8(facial nerve grading), 3 points during action 1 point during rest(MoReSS). He had only occasional tinnitus and auditory hypersensitivity. Acupuncture and electro-acupuncture are estimated to be good for facial palsy after removal of facial schwannoma. More cases are required to develop treatment of facial palsy.

소규모 하수 재이용을 위한 디스크필터의 처리 효율 증진에 관한 연구 (Enhancement of Discfilter Removal Efficiency for Small-scale Wastewater Reclamation)

  • 최낙철;김봉주;박성용;박형우;이성재;박천영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권4호
    • /
    • pp.66-72
    • /
    • 2015
  • The aim of this study was to enhance of the Discfilter process (maximum treatment capacity - 500 ton/day) removal efficiency for small-scale wastewater reclamation under various influent wastewater conditions (with / without coagulation process, coagulant content and temperature). The result of chemical resistance test for fiber filter in the Discfilter that weight loss was obtained with 0.535% under pH 3, 0.092% under pH 9 and 0.028% under 10% NaClO. The removal efficiency test of Discfilter process on the with / without coagulation process showed that with coagulation process condition was occurred CODMn of 42.26 ± 0.61, BOD5 of 88.72 ± 0.44, T-P of 84.67 ± 0.72 and SS of 90.58 ± 0.61. The removal efficiency of Discfilter process on the coagulant content (4.5, 5.0 and 5.0 mL/min) and temperature (< 10℃, 10℃~ 20℃ and > 20℃) conditions were increased as coagulant content and temperature increased. This study demonstrated the potential application of Discfilter process for small-scale wastewater reclamation.

양돈폐수처리시 실규모 이단 혐기성공정의 성능 및 메탄회수 (Methane Recovery and Performances of Full-scale Two-stage Anaerobic Process Treating Piggery Wastewater)

  • 정진영;정윤철;강신현;정형숙
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.256-262
    • /
    • 2005
  • The purpose of this study is to investigate the performances of organic removal and methane recovery by using a full scale two-phase anaerobic system. The full scale two-phase anaerobic process was consists of an acidogenic anaerobic baffled reactor (ABR) and a methanognic upflow anaerobic sludge blanket (UASB) reactor. The volumes of acidogenic and methanogenic reactors were designed to $28.3m^3$ and $75.3m^3$. The two-phase anaerobic system represented 60-82% of COD removal efficiency when the influent COD concentration was in the range of 7,150 to 16,270 mg/L after screening (average concentration is 10,280 mg/L). After steady-state, the effluent COD concentration in the methanogenic reactor showed $2,740{\pm}330 mg/L$ by representing average COD removal efficiency was $71.4{\pm}8.1%$ when the operating temperature was in the range of $19-32^{\circ}C$. The effluent SCOD concentration was in the range of 2,000-3,000 mg/L at the steady state while the volatile fatty acid concentration was not detected in the effluent. Meanwhile, the COD removal efficiency in the acidogenic reactor showed less than 5%. The acidogenic reactor played key roles to reduce a shock-loading when periodic shock loading was applied and to acidify influent organics. Due to the high concentration of alkalinity and high pH in the effluent of the methanogenic reactor, over 80% of methane in the biogas was produced consistently. More than 70% of methane was recovered from theoretical methane production of TCOD removed in this research. The produced gas can be directly used as a heat source to increase the reactor temperature.

Pilot Plant Study on Biological Nutrient Removal of Wastewater

  • Ahn, Sang-Jin;Kim, Geon-Heung;Ahn, Bok-Kyoun
    • Korean Journal of Hydrosciences
    • /
    • 제1권
    • /
    • pp.99-106
    • /
    • 1990
  • An extensive biological nutrient removal pilot plant study of anoxic/anaerobic/ aerobic treatment process was conducted to eastblish an optimum operational mode using primary dffluent. Two operational modes, (1) Qr/Q was 3.0 and maintaining EMLSS of 3100 mg/L in which the best operational results were obtained from previous bench scale study using synthetic wastewater (2) Qr/Q was 0.5 and EMLSS of 2200 mg/L which was compatible with the main plant, were Compared and evaluated for removal of nitrogen and/or phosphorous under field conditions. The nitrogen removal increased with increasing recycle ratios, but the phosphorous removal revealed more consistent results with 83percent removal efficiency in the second mode compared with 80 percent in the first mode. Above all, the two modes equally showed good BOD and nitrogen removals by nitrification-denitrification processes. It was also observed that no scum formed in the pilot plant and the sludge exhibited excellent settling characteristic all the time. The modified biological nutrient removal train can be adopted to the main plant without any major changes of their operational modes.

  • PDF

인제거용 흡착제로서 밀스케일로부터 선별된 마그네타이트 적용 연구 (A study on the application of mill scale-derived magnetite particles for adsorptive removal of phosphate from wastewater)

  • 김윤중;엘라;최영균
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.281-287
    • /
    • 2017
  • Mill scale, an iron waste, was used to separate magnetite particles for the adsorption of phosphate from aqueous solution. Mill scale has a layered structure composed of wustite (FeO), magnetite ($Fe_3O_4$), and hematite ($Fe_2O_3$). Because magnetite shows the highest magnetic property among these iron oxides, it can be easily separated from the crushed mill scale particles. Several techniques were employed to characterize the separated particles. Mill scale-derived magnetite particles exhibited a strong uptake affinity to phosphate in a wide pH range of 3-7, with the maximum adsorptive removal of 100%, at the dosage of 1 g/L, pH 3-5. Langmuir isotherm model well described the equilibrium data, exhibiting maximum adsorption capacities for phosphate up to 4.95 and 8.79 mg/g at 298 and 308 K, respectively. From continuous operation of the packed-bed column reactor operated with different EBCT (empty bed contact time) and adsorbent particle size, the breakthrough of phosphate started after 8-22 days of operation. After regeneration of the column reactor with 0.1N NaOH solution, 95-98% of adsorbed phosphate could be detached from the column reactor.