• 제목/요약/키워드: Removal of T-N and T-P

검색결과 444건 처리시간 0.033초

인공섬을 이용한 소형 저수지의 수질 개선 (Water Quality Improvement by Artificial Floating Island)

  • 박현진;권오병;안태석
    • 한국환경복원기술학회지
    • /
    • 제4권1호
    • /
    • pp.90-97
    • /
    • 2001
  • For improvement of water quality, $20m^2$ of artificial floating plant islands planted with Iris pseudoacorus, were installed in small pond on March, 1999. Small pond has surface area $1,000m^2$ and mean depth 1.5 m. The density of plants was 16 per $m^2$ by using jute pot. Environmental parameters such as COD, SS, T-N, T-P and planktons were biweekly measured from 29 March to 28 September. Because of the small portion of floating island, the effect for water quality improvement was not sufficient. But considering the data of plant growth and nitrogen and phosphorus uptake capacity of plant, about 40% of coverage by artificial floating island was needed for elimination of whole nutrients from inflow.

  • PDF

분뇨처리장의 공정개선에 의한 처리효율 향상에 관한 연구 (Improvement of treatment efficiency for sanitary treatment facilities by process modifications)

  • 이찬원;김승현;김창수;문성원;전홍표;윤종섭
    • 한국환경과학회지
    • /
    • 제13권6호
    • /
    • pp.571-579
    • /
    • 2004
  • There is a need to improve the efficiency of the existing sanitary treatment facilities, because the effluent standard becomes more stricter and septic sludge increased. Thus, operating processes of sanitary treatment system in M city changed with installation of additional facilities. Process modifications were as follows: Dilution water was added to the next process after primary aeration tank. Some secondary sedimentation sludge was recycled to primary aerator so that most of the organics were stabilized in primary aeration tank under automatic control of dissolved oxygen. The line of effluent from dewatering process flowing to the activated sludge tank was changed to the primary aerator. The primary sedimentation sludge line was linked to a thickener. Polymer was added to the activated sludge tank. The effluent of primary aerator and aerobic digester was recycled from the 5th to the 1st sector. As consequencies of above process modifications, the improvement of removal efficiency was achieved as BOD 54%, COD 42%, SS 61%, T-N 39%, and T-P 12%, respectively.

임플란트 직경이 골유착에 미치는 영향에 관한 연구 (INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS)

  • 이준호;신상완;권상호
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

Comparative study of analgesia with bupivacaine 0.25% versus 0.5% for third molar removal under general anesthesia

  • Dhanrajani, Parmanand;Chung, Patrick
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제16권2호
    • /
    • pp.117-122
    • /
    • 2016
  • Background: The aim of this study was to compare the effectiveness and duration of action of two concentrations of bupivacaine with adrenaline for postoperative pain in patients undergoing surgical removal of four third molars under general anesthesia. Methods: Sixty patients undergoing surgical removal of four wisdom teeth received bupivacaine 0.5% (n = 30) or 0.25% (n = 30). The severity of pain in the immediate recovery period and at 2 and 24 h after surgery was recorded using the visual analogue scale. Differences were assessed by box and whisper plot and the Student's t-test. Results: The analgesic effects of the 0.25% and 0.5% doses were significantly different (P = 0.022) at 30 min after surgery but not after 2 and 24 h. The difference of mean of 0.25% and 0.5% was much higher after 0.5 h but less after 2 and 24 h. Conclusions: Bupivacaine 0.5% was statistically better for pain control during the immediate postoperative period, but there was no significant difference in pain control between the two dose strengths at 2 and 24 h after surgery.

진동막 분리장치를 이용한 축산폐수의 질소.인 제거에 관한 연구 (The removal of nitrogen & phoshorus for the swine wastewater by VSEP membrane system)

  • 지은상;김재우;신대윤
    • 환경위생공학
    • /
    • 제15권3호
    • /
    • pp.31-36
    • /
    • 2000
  • Conventional membrane systems was difficults to treatment for the swine waste water. Technological advances in membrane filtration systems have created opportunity for the swine wastewater to treat effluent streams in order to meet stricter environmental constraints. "Vibratory Shear Enhanced Processing(VSEP)" developed by new logic international makes it possible to filter effluent streams without the fouling problem exhibited by conventional membrane systems. Various kinds of waste water occurred to and swine wastewater experiment with "VSEP" set up conventional reverse osmosis membrane (ACM-4, ESPA, BW-30). The results were as followes : Treatment efficiency for the input COD(From $332mg/{\ell}$ to $4,968mg/{\ell}$) was 98%. Treatment efficiency for the input SS(From $140mg/{\ell}$ to $4,040mg/{\ell}$) was 100%(All together). Treatment efficiency for the input T-N(From $155mg/{\ell}$ to $934mg/{\ell}$) was 97%~99.8%. Treatment efficiency for the input T-P(From $28.6mg/{\ell}$ to $132mg/{\ell}$) was 99.7% and up. ESPA membrane excels three types of reverse osmosis membranes applied VSEP in removal efficiency.

  • PDF

Preparation of Water Soluble Chitosan Blendmers and Their Application to Removal of Heavy Metal ions from Wastewater

  • Seo, Sang-Bong;Toshio Kajiuchi;Kim, Dae-In;Lee, Soon-Hong;Kim, Hak-Kil
    • Macromolecular Research
    • /
    • 제10권2호
    • /
    • pp.103-107
    • /
    • 2002
  • High purity water soluble chitosans (WsCs) were employed as a flocculant to remove heavy metal ions from wastewater of industrial plating wastewater treatment complex. Their weight average molecular weights and polydispersities were 272,000~620,000 g/mol and 1.4~1.9 range, respectively and were readily soluble in water in the pH range of 3~11. Heavy metal ions such as chromium, iron and copper were removed well by WsCs. When WsCs was blended with either sodium N, N-diethyldithiocarbamate trihydrate (SDDC$_{T}$) or sodium salicylate (SSc), the removal efficiency was further increased primarily due to the excess amount of hydrophilic sulfonic and carboxylic groups. Especially, in the case of WsCs-SSc the remaining chromium and copper concentrations were 0.1 mg/L and 9.5 mg/L, which are 1/15 and 1/3 compared with that of pure WsCs, respectively. The former is within the acceptable limit, but the latter is not. Therefore, the effective copper flocculant remains to be studied.d.

멤브레인을 침지한 하수고도처리공법에서 기존간헐포기와 개량간헐포기의 효율성 비교평가 (Evaluation of CIA(Conventional Intermittent Aeration) and MIA(Modified Intermittent Aeration) in Membrane Submerged Advanced Wastewater Treatment Process)

  • 서인석;김연권;김지연;김홍석;김병군;최창규;안효원
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.257-264
    • /
    • 2006
  • In this study, the treatment of domestic wastewater in a field-scale membrane submerged intermittently aerated activated sludge process($210m^3/day$) was investigated under difference aeration methods. Operating temperature was 5.4 to 25.0 and membrane used in this study is a polyethylene hollow fiber membrane(pore size $0.4{\mu}m$). The range of operating flux was $9.7{\sim}24.4l/m^2-h$ and membrane permeates periodically operated for 7min followed idle for 3 min. The results showed that MIA(modified intermittent aeration) was more efficient in nitrogen and phosphorus removal. The removal efficiencies of T-N and T-P were 73.0% and 69.6% for CIA(conventional intermittent aeration) and 57.5%, 58.6% for MIA (modified intermittent aeration). With application of modified intermittent aeration, DO reached nearly Omg/l within 10 minutes after air off. Organics of influent could be entirely consumed to the denitrification and the P-release without the influence by remained DO in intermittent aeration reactor. Therefore, newly developed KSMBR(Kowaco-KMS-Ssangyoung Membrane Bio-Reactor) process with modified intermittent aeration can be one of the useful process for stable nitrogen and phosphorus removal.

Cu/MCM-41 메조포러스 촉매 제조 및 NO 제거 특성 (Preparation and Characterization of Cu/MCM-41 Mesoporous Catalysts for NO Removal)

  • 박수진;조미화;김석;권수한
    • 공업화학
    • /
    • 제16권6호
    • /
    • pp.737-741
    • /
    • 2005
  • 본 연구에서는 제조한 MCM-41에 Cu의 함량에 따른 NO의 전환율을 고찰하였다. MCM-41은 실리카 원으로 colloid silica를 사용하였고, template로 cetyltrimethylammonium chloride (CTMACl)를 사용하여 수열 합성하였으며, Cu/MCM-41은 Cu(II) acetylacetonate를 사용해서 Cu의 농도를 5, 10, 20 그리고 40%로 변화시켜 제조하였다. 표면 특성은 pH, FT-IR로 분석하였고, 육방배열의 1차원 기공 구조는 XRD로 고찰하였다. $N_2/77K$ 등온흡착 특성은 BET식과 t-plot을 이용하여 확인하였으며, NO 제거 효율은 가스크로마토그래프를 이용하여 측정하였다. 실험 결과, Si-OH와 Si-O-Si의 stretching vibration peak가 관찰되었으며, (100), (110), (200) 그리고 (210)의 육방배열의 1차원 구조를 확인하였다. Cu 금속이 도입된 MCM-41은 Cu 도입량이 증가할수록 비표면적과 미세기공부피는 감소한 반면에 NO 제거 효율은 증가하였다. 결과적으로 Cu/MCM-41의 Cu의 함량이 증가함에 따라 전체 촉매작용 반응과 NO 제거율이 증가하였다.

The Processing of Livestock Waste Through the Use of Activated Sludge - Treatment with Intermittent Aeration Process -

  • Osada, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권5호
    • /
    • pp.698-701
    • /
    • 2000
  • To prevent surface and underground water pollution, wastewater treatment is essential. Four bench-scale activated sludge units (10 L operational volumes) were operated at 5, 10 and $20^{\circ}C$ for evaluation of treatment efficiencies with typical wastewater from swine housing. The units were set for a 24-hour cycle. As compared to the conventional process, high removal efficiencies for organic substances, nitrogen and phosphorus in swine wastewater were obtained simultaneously with an intermittent aeration process (lAP). The NOx-N produced during an aeration period was immediately reduced to nitrogen gas (e.g. $N_2$ or $N_2O$) in the subsequent non-aeration periods, and nitrification in aeration periods occurred smoothly. Under these conditions, phosphorus removal occurred with the release of phosphorus during the non-aeration periods followed by the excess uptake of phosphorus in the activated sludge during aeration periods. It was confirmed that the lAP had a better ability to remove pollutants under both low temperatures and high nitrogen loading conditions than the ordinary method did. In addition to that, the total emission of $N_2O$ from lAP was reduced to approximately 1/50 of the conventional process for the same loading. By adopting an adequate aeration programme for individual swine wastewater treatment, this system will provide a promising means for nitrogen and phosphorus control without pH control or addition of methanol.

전기분해에 의한 염색폐수 처리공정에 관한 연구 (A study on dye wastewater treatment using the electrolysis)

  • 김성국;박상원;홍대일
    • 한국환경과학회지
    • /
    • 제8권4호
    • /
    • pp.539-545
    • /
    • 1999
  • Dye wastewater was treated by using an electrochemical oxidation process. Various combinations of electrodes such as carbon, Al and Fe were investigated. In this study, electrode material, electrolyte concentration, electrode distance, current density, and pH value were found to have significant effect on both pollutant removal efficiency and current efficiency in electrochemical oxidation process. After electrolysis for 40min with carbon/Al, it was observed that COD, $T-N, NH_{4}^{+}-N$ and color of treated wastwater were reduced from 580mg/$\ell$ to 145mg/$\ell$, 67.2mg/$\ell$ to 26.8mg/$\ell$, 46.8mg/$\ell$ to 1.4mg/$\ell$, and 4200 Pt-Co units to 336 Pt-Co units, respectively. The optimal conditions of the electrooxidation process to treat the wastewater for this study were found to be such : current density ; 16.67mA/$cm^2$, electrode distance ; 2.5cm, pH value ; 5.0 and carbon/Al electrode.

  • PDF