• 제목/요약/키워드: Removal efficiency assessment

검색결과 112건 처리시간 0.021초

섬유 형태에 따른 염색폐수 배출특성 연구 (Studies on the Effluent Characteristics of Dyeing Wastewater by Textile Classification)

  • 이수형;박정민;박상정;정제호
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.881-888
    • /
    • 2007
  • In order to investigate the characteristics of the non-biodegradable material, the $BOD_5/COD_{Cr}$ ratio was used. The average ratio of industrial complex's influent wastewater was 2.29~2.96, the effluent ratio was 4.29~19.0. The removal efficiency of $UV_{254}$ by physicochemical treatment was 22.8~94.7% and 5.3~77.2% by biological treatment, respectively. Of the wastewater removal efficiency for each of the items, the $BOD_5$ treatment efficiency was the greatest at 97.3% and the color & TN treatment efficiency was 40~70%. The study of the economical assessment showed that the complex as well as the individual companies spent 722~1,298 won for each ton of treated wastewater. All of the wastewater treatment facilities spent the most money on chemicals needed to treat the wastewater. The total cost for Nylon manufacturing wastewater treatment plant was the greatest while the total cost for cotton manufacturing wastewater treatment plant turned out to the lowest. As respects of removal efficiency and economocal assessment, Polyester A and Cotton manufacturing wastewater treatment plants were better effective than a dyeing industrial complex wastewater treatment plant.

생물학적 처리공정 내 Alum 주입에 따른 인 처리 효율과 미생물 활성도 변화에 관한 연구 (Study on Change of Microbial Activity and Removal Efficiency of Phosphorus with Alum Injection in the Biological Process)

  • 최정수;주현종
    • 한국물환경학회지
    • /
    • 제27권2호
    • /
    • pp.188-193
    • /
    • 2011
  • The effects of coagulants on the microorganisms when they are injected directly into the biological treatment facility for T-P removal have been easily observed from the results of past experiments. As such this study is set out to derive the effective plans for the coagulant dosage by analyzing the effects of the injected coagulant on the microbial activity during the chemical treatment for T-P removal. The research methods entailed the assessment of removal efficiency of T-P according to the coagulant dosage while changing the molar ration between Alum and influent phosphorus. At the same time Specific Oxygen Uptake Rate (SOUR) according to the coagulant dosage was measured. SOUR was used as a method for indirect assessment of the microbial activity according to the coagulant dosage. The results from the study showed that with the increase in the alum dosage, the removal efficiency T-P tended to increase. On the other hand, the increase in coagulant dosage resulted in the decrease in SOUR, which indicates the decrease in the microbial activity. Such reduction in the activity could be explained by the increase in the concentration of removal efficiency of $TBOD_5$. Based on experiment results from the study, it is determined that coagulant dosage affects the microbial activity. Moreover, the indirect assessment on the microbial activity using SOUR is considered possible.

실내용 공기청정기 유형별 실내환경개선 성능에 대한 비교평가 (Comparative Efficiency Evaluation of Air Cleaners for Improving Indoor Air Quality)

  • 나경호;손진석;성기준;장영기
    • 환경영향평가
    • /
    • 제14권3호
    • /
    • pp.109-115
    • /
    • 2005
  • This study was conducted to evaluate the efficiency of indoor air cleaners and to inform how to select them correctly to the users. The efficiencies of removing suspended bacteria per hour were $64.3{\pm}13.1%$ for filter, wet, and complex type, respectively, which showed the complex type was the most efficient. The removal efficiencies of formaldehyde (HCHO) after two hours operation of air cleaners showed 88.3% and 81.1% for filter and wet type, respectively. The efficiency of complex type, with removal rate of 55.5~58.4%, was decreased after 30 minutes operation. Therefore, it is recommended to perform over 60 minutes when doing air cleaner certification test for HCHO removal efficiency. Generally, air cleaners having low wind volume showed higher efficiency. All tested air cleaners had no potential for removing of volatile organic compounds (VOCs), which is toxic substances, and it is desirable to develop a device which can control these substances. The results also confirmed that there was no ozone production from all tested air cleaners. And it is recommended to ventilate for 20 minutes every four hours to maintain 50% ventilation status.

자연정화공법을 이용한 2차 하수처리수의 수질 개선에 관한 연구 (A Study on the Quality Improvement of Secondary Treatment Effluent Utilize the Natural Purification Method)

  • 안태웅;최이송;오종민
    • 환경영향평가
    • /
    • 제18권2호
    • /
    • pp.79-87
    • /
    • 2009
  • This study was performed for the application of porous concrete blocks and aquatic plants for the water purification in small urban stream. This study investigated the ability of water purification according to various environments, algae and aquatic plants. When the porous concrete was used as contact media, the average removal efficiencies of SS, BOD and COD were 85~95%, 50~60% and 65~75%, respectively. Also, when the porous concrete and aquatic plants was used the average removal efficiency of SS, BOD and COD were 90~95%, 60~70% and 70~80%, respectively. As the results, average removal efficiency of total nitrogen, at the condition of the porous concrete and aquatic plants, was about 40-50%, then, that of total phosphorus was about 60-70%.

체류시간이 식생수로 저감효율에 미치는 영향 (Effect of Retention Time on the Removal Efficiency in Grassed Swale)

  • 백승봉;길경익
    • 한국습지학회지
    • /
    • 제16권3호
    • /
    • pp.371-381
    • /
    • 2014
  • 현재까지 국내에서 수질관리 정책이 점오염원 관리를 우선 시 하고 있다. 비점오염원은 배출특성, 배출지점 및 배출량의 파악에 매우 어려움이 있다. 이러한 비점오염 관리를 위해 다양한 비점오염저감시설들에 대한 개발 및 연구가 진행되고 있다. 비점오염시설의 평가를 위해 다양한 효율산정 방법들이 제시되고 있다. 본 연구에서는 강우 시 식생수로 모니터링 결과를 통해 체류시간이 저감효율에 미치는 영향에 대해 연구를 수행하였다. 또한 여러 가지 저감효율 산정 방법에 따른 차이를 비교하고자 하였다. 식생수로에서 체류시간에 따른 효율 분석 결과 체류시간이 길수록 저감효율도 높아지는 것으로 나타났다. 이는 식생수로의 안정적인 저감효율을 확보하기 위해선 충분한 체류시간이 확보 되어야 한다고 판단된다.

Performance and flow field assessment of settling tanks using experimental and CFD modeling

  • Nouri, Alireza Zamani;Heydari, Mohammad Mehdi
    • Membrane and Water Treatment
    • /
    • 제8권5호
    • /
    • pp.423-435
    • /
    • 2017
  • Settling Basins are one of the most important and popular methods for removal of suspended sediments irrigation and drainage networks or power canals taking off from an alluvial river and wastewater treatment plant. Improving the performance and so increasing sediment removal efficiency of settling basins by an alternative method is necessary. In the present work, the effect of baffle and its angle of attack with the flow (${\theta}$) on the sediment removal efficiency is investigated by conducting a series of experiments on a straight canal with 8 m length, 0.3 m width and 0.5 m height and 3 m length of basin equipped with an adjustable glass baffle. A numerical analysis has been carried out using ANSYS Fluent 3D software (a general purpose computational fluid dynamics simulation tool) for three Froude numbers from the experiments. The numerical and experimental results were found to match reasonably well.

고속도로 현장별 비점오염 저감시설 선정방안 연구 (A Study for selecting the Highway Sites' Best Management Practice for Nonpoint Source Pollution)

  • 이용복;최상일;박계수;성일종;정선국
    • 환경영향평가
    • /
    • 제20권6호
    • /
    • pp.857-866
    • /
    • 2011
  • This research categorized EIA target highways into following three types in order to minimize non-point source pollution from highway runoff. 1. Big drainage basin. 2. Small drainage basin. 3. Bridge section. The Natural, Filter and Swirl-Type devices were evaluated in terms of removal efficiency of TSS, BOD, COD, T-N, T-P, compatibility of site selection, economic feasibility, and maintenance convenience through which the final BMP was selected. According to the removal efficiency result, the area of Big and Small Drainage basin and bridge section had higher removal efficiency with natural facility than that of the Filter or Swirl-Type device. To make appropriate selection of highways'BMP for non-point source pollution, this study will aim to contribute to building more environmentally friendly highways by proposing the selection process that is made of 5 stages. 1. Selecting the target drainage basin. 2. Selecting the land for the mitigation facility. 3. Analysing the ease of maintenance. 4. Technically evaluating each installation. 5. Evaluating the effective implementation methods.

빗물펌프장에 설치된 인공습지의 비점오염원 저감효율 연구 (A Study of Non-point Source Reduction Efficiency by Constructed Wetland installed in Flood Pumping Station)

  • 천석영;김지태;이일국;장순웅
    • 환경영향평가
    • /
    • 제23권1호
    • /
    • pp.67-74
    • /
    • 2014
  • The aim of this study was evaluated the effects of total rainfall, rainfall intensity and antecedent dry days and identify the correlation analysis with the EMC removal efficiency, in order to provide an understanding of the operation and maintenance factors of constructed wetland in flood pumping station. This study was conducted total of 20 monitoring in a catchment(326.2 ha) of constructed wetland in Ga-un flood pumping station located at the downstream of the Wang-suk stream. The determined EMC removal efficiencies were $36.04{\pm}9.45%$ for BOD, $38.50{\pm}13.50%$ for $COD_{Mn}$, $34.34{\pm}13.05%$ for TN and $34.22{\pm}14.27%$ for TP, respectively. These results showed that the pollutants concentration and EMC were reduced while passing through the constructed wetland. In the correlation analysis, the highly correlations with EMC removal efficiency of BOD and $COD_{Mn}$ were observed for total rainfall and rainfall intensity (P<0.05). However, the correlations were not found with TN and TP for rainfall variables.

지렁이 분변토를 접종한 세라믹 바이오필터의 암모니아 제거에 미치는 온도의 영향 (Effect of Temperature on Removal of Ammonia in the Ceramic Biofilter Inoculated with Earthworm Casts)

  • 조경숙
    • 환경영향평가
    • /
    • 제9권1호
    • /
    • pp.39-46
    • /
    • 2000
  • Removal of ammonia using the porous ceramic biofilter inoculated with earthworm casts was characterized. By assuming a plug air flow in the biofilter and applying the Michaelis-Menten equation, the maximum removal rate of $NH_3$ was $280.7g-N{\cdot}m^{-3}{\cdot}h^{-1}$($18.0g-N{\cdot}kg^{-1}{\cdot}d^{-1}$) at $30^{\circ}C$. $NH_3$ removal rate was increased as temperature increases from $15^{\circ}C$ to $35^{\circ}C$. The maximum removal rate was $285.8g-N{\cdot}m^{-3}{\cdot}h^{-1}$($18.8g-N{\cdot}kg^{-1}{\cdot}d^{-1}$) at $35^{\circ}C$. At $15^{\circ}C$, the $NH_3$ removal rate was $122.8g-N{\cdot}m^{-3}{\cdot}h^{-1}$($8.1g-N{\cdot}kg^{-1}{\cdot}d^{-1}$). When 210 ppm $NH_3$ was supplied to the biofilter at space velocity of $220h^{-1}$, the removal efficiency of $NH_3$ at 15, 25, 30 and $35^{\circ}C$ was 80, 90, 95, and 96%, respectively. The removal rate of the ceramic biofilter was 3 to 15 times higher than other biofilters comparing the removal efficiency of $NH_3$ per unit volume of carrier. This result indicates that earthworm casts and porous ceramics are very good inoculum source and carrier, respectively, for the $NH_3$-degrading biofilter.

  • PDF

분포형 유역모델을 이용한 식생여과대의 오염부하 저감효과 분석 (Evaluation of Pollution Loads Removal Efficiency of Vegetation Buffer Strips Using a Distributed Watershed Model)

  • 박민혜;조홍래;구본경
    • 환경영향평가
    • /
    • 제25권6호
    • /
    • pp.369-383
    • /
    • 2016
  • 본 연구에서는 강원도 평창군 대관령면에 위치한 산지초지와 초지의 말단에 조성한 식생여과대(Vegetation Buffer Strip, VBS)에 분포형 유역모델 CAMEL을 적용하였다. 그리고 이를 통해 확보한 매개변수를 초지와 식생여과대로 구분한 다수의 시험격자에 적용하여 다양한 인자들에 의한 식생여과대 오염부하 저감효과를 평가하였다. 시험격자를 이용한 시나리오 모의결과, 식생여과대에서 강우의 직접유출량은 식생여과대 폭이 넓어질수록 감소하는 것으로 나타났으며, 전반적으로 경사가 높을수록 오염물질의 저감효율은 낮아지는 것으로 나타났다. 유사의 경우, 식생여과대 폭에 따른 저감효율은 전반적으로 큰 차이를 보이지 않았다. TOC와 TN의 경우, 시험격자의 경사가 $10^{\circ}$, $20^{\circ}$일 때, 식생여과대 폭에 따른 저감효율은 큰 차이를 보이지 않았으나, 경사가 $30^{\circ}$일 때 식생여과대 폭이 좁을수록 높은 저감효율을 보였다. 반면, TP의 경우, 양토(Loam)에서의 저감효율은 전반적으로 높지만, 사양토(Sandy loam)에서는 경사가 $20^{\circ}$, $30^{\circ}$일 때 식생여과대 폭이 넓을수록 높은 저감효율을 보이는 것으로 분석되었다. 이는 TOC와 TN의 모의결과와는 상반되는 결과로 대부분 입자성 물질로 존재하는 인의 경우 지표면에서의 포착현상으로 인해 길이에 따라 비례적으로 저감효율이 높아지는 경향을 보이는 것으로 사료된다. 본 연구에서 구축한 모델은 향후 비점오염물질의 유출을 효과적으로 저감할 수 있는 식생여과대 조성을 위한 기준 등을 제안하는데 효과적으로 사용될 수 있을 것으로 기대된다.