• Title/Summary/Keyword: Removal Apparatus

Search Result 111, Processing Time 0.027 seconds

Effect of Ethylene Removal on Fruit Quality of Oriental Pear during Storage (저장고 내의 에틸렌 제거가 배 과실의 품질에 미치는 영향)

  • Kim Ho-Cheol;Bae Kang-Soon;Bae Jong-Hyang;Jeon Kyung-Soo;Hong Jong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.15 no.1
    • /
    • pp.78-83
    • /
    • 2006
  • The objective of this study was to examine effect of ethylene removal apparatus on fruit quality of 'Niitaka' pear (Pyrus pyrifolia) in case of a double storage of apples and pears in a storage room. Ethylene and carbon dioxide concentration were efficiently decreased by the ethylene removal apparatus. Fruit weight loss was high at double storage of apples and pears (DAP) in a storage room compared with storage of pears. Fruit core browning was $5{\sim}22.5%$ at the fruits in DAP, but as setting ethylene removal apparatus it was not occurred till 90 days after storage. Soluble solids content and fruit peel hardness were not different among the treatments. Accordingly, a double storage of apples and pears in a storage room is possible as setting ethylene removal apparatus.

Nutrient Removal in an Advanced Treatment Process using BIO-CLOD (BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거)

  • Park, Wan-Cheol;Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.4
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

Removal Effect of Acid Gases by Reactant Mixer and Distributor of Bag Filter in Dry Scrubbing with NaHCO3 (중탄산나트륨 건식공정에서 반응제 혼합 장치 및 백필터 분배장치에 의한 산성가스 제거 영향)

  • Lee, Young-Man;Kwak, Yeon-Ho;Bae, Woo-Keun;Kwon, Ki-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.402-409
    • /
    • 2009
  • Sodium bicarbonate ($NaHCO_3$) was used as a reactant for the removal of acid gases from a waste incinerator. The removal efficiencies of HCl and $SO_x$ were tested with a reactant mixing apparatus and a distributor installed at the bag filter inlet. It was shown that the stoichiometric ratio of $NaHCO_3$ to the acid gases which allows a removal of over 90% for both HCl and $SO_2$ was about 1.2. When a reactant mixing apparatus was installed on the duct, the removal efficiencies of HCl and $SO_2$ at the end of the duct were increased by approximately 1.5 and 3 times respectively, compared to when the apparatus was not installed. At the end of the bag filter, the removal efficiencies of the both were as high as 98% with a stoichiometric ratio of 1.35. Installing a reactant mixing apparatus on the duct and a distributor at the entrance of the bag filter and using $NaHCO_3$ as a reactant helped overcome the problem of low removal efficiencies of acid gases by dry scrubbing.

Treatment Performance and Microbial Community Structure in BAC-process Treating Contaminated Groundwater by Water-soluble Cutting Oil (생물활성탄을 이용한 절삭유로 오염된 지하수의 처리특성과 미생물군집구조 해석)

  • Lim Byung-Ran;Bae Ci Ae;Lim Ho-Ju;Cho Chang-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.71-76
    • /
    • 2006
  • Treatment performance and microbial community structure were investigated in water-soluble cutting oil treatment process using biological activated carbon. DOC removal in BACI column at $15^{\circ}C$ was higher than at $25^{\circ}C$, but those of BAC3 column after 60days was high at$25^{\circ}C$. Also, quinone content of first-step reactors at $25^{\circ}C$ and $15^{\circ}C$ was much the same, but those of the third-step reactor at $25^{\circ}C$ was higher than at $15^{\circ}C$. The dominant type of two apparatus was ubquinone (UQ)-l 0 followed by UQ-8. Menaquinones were detected from $25^{\circ}C$ apparatus and effluent. This suggested that DOC removal at $25^{\circ}C$ was advanced degradation by attached microorganisms on the activated carbon surface. The DOC removal in long-term activated carbon apparatus increased with going in BAC3 column. This indicated the influent of POC was a result of DOC removal efficiency decrease. Integrated DOC removal from start point in experiment to break point and quinone content were showed a tendency of increasing with going last-step activated carbon apparatus. Therefore, the biological activated carbon apparatus used by this study was effective treatment process in contaminated groundwater by water-soluble cutting oil.

Development of an Apparatus for Removing Magnetic Sludge by Permanent Magnets Set up in the Condenser of the Power Plant (영구자석을 이용한 복수기 집수정 내부 자성이물질 제거장치 개발)

  • Bae, Jun-Ho;Kim, Moon-Saeng;Hwang, Beom-Cheol;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.9
    • /
    • pp.938-948
    • /
    • 2009
  • In this paper, permanent magnets were used to remove magnetic sludge in the condenser of the power plant. To obtain the flow characteristics and magnetic information that are needed for determining a proper design of the magnetics sludge removal apparatus, numerical simulations were performed through the use of two commercial codes, ANSYS Workbench-Emag and CFX. Experiments were also performed on various kinds and sizes of magnets to obtain the magnetic information through a gauss meter. By analyzing the results of simulations and experiments, the minimum magnetic force that is able to remove the any size of the magnetic sludge in the condenser was calculated, and the design of the removal apparatus was confirmed. The test model which was confirmed by simulations and experiments was made. After testing, the test results were compared with those of numerical simulations and have good agreements.

A Study on Remediation of Heavy Metal Contaminated Soil using a Soil Electrolysis Apparatus with Spiral Paddle (나선형패들이 장착된 토양전기분해장치를 이용한 중금속 오염토양 정화에 관한 연구)

  • Lee, Jun-Hee;Choi, Young-Ik;Jung, Jin-Hee
    • Journal of Environmental Science International
    • /
    • v.26 no.6
    • /
    • pp.797-802
    • /
    • 2017
  • This study aimed to remove organic matter and heavy metals that could affect the recycling of soils contaminated by heavy metals, by means of electrolysis, carried out simultaneously with the leaching of the soil. To ensure better experimental equipment, a soil electrolysis apparatus, equipped with spiral paddles, was used to agitate the heavy-metal-contaminated soil effectively. The heavy-metal-contaminated soil was electrolyzed by varying the voltage to 5 V(Condition 1), 15 V(Condition 2), and 20 V(Condition 3), under the optimal operating conditions of the electrolysis apparatus, as determined through previous studies. The results showed that the pH of the electrolyte solution and the heavy-metal-contaminated soil, after electrolysis, tended to decrease with an increase in voltage. The highest removal efficiencies of TOC and $COD_{Cr}$ were 18.8% and 29.1%, 38.8% and 4.2%, and 33.3% and 50.0%, under conditions 1, 2 and 3, respectively. Heavy metals such as Cd and As were not detected in this experiment. The removal efficiencies of Cu, Pb and Cr were 4.7%, 8.3% and 2.1%, respectively, under Condition 1, while they were 42.9%, 15.2% and 22.1%, respectively, under Condition 2, and 4.7%, 23.0%, and 24.9%, respectively, under Condition 3. These results suggest that varying the voltage with the soil electrolysis apparatus for removing contaminants for the recycling of heavy-metal-contaminated soil allows the selective removal of contaminants. Therefore, the results of this study can be valuable as basic data for future studies on soil remediation.

Optimum Depth and Volume Ratio of Aerobic to Anaerobic Bed for Development of Small-Scale Sewage Treatment Apparatus by Natural Purification Method (자연정화공법에 의한 소형 하수처리장치 개발을 위한 최적 깊이 및 호기.혐기 비율)

  • Seo, Dong-Cheol;Park, Mi-Ryoung;Kwak, Nae-Woon;Hwang, Ha-Na;Lee, Hong-Jae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.1
    • /
    • pp.14-24
    • /
    • 2006
  • To develop small-scale sewage treatment apparatus for detached house of agricultural village, a small-scale sewage treatment apparatus by natural purification method that consisted of aerobic and anaerobic bed was constructed. To reduce the area of a sewage treatment apparatus, four different fitter media were used and each filter medium was coarse sand, broken stone, steel slag, and mixed fitter media (coarse sand : broken stone : steel slag = 1:1:1). The efficiency of sewage treatment according to the depth of aerobic and anaerobic bed and the volume ratio of aerobic to anaerobic bed were investigated in small-scale sewage treatment apparatus. The removal rate of pollutants according to the depth of aerobic and anaerobic bed in small-scale sewage treatment apparatus was high in the order of 50 cm < 70 cm < 90 cm. The removal rate of pollutants according to the ratio of aerobic to anaerobic bed in small-scale sewage treatment apparatus was high in the order of 1:1 < 1:2 $\fallingdotseq$ 1:3. Under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P were $98{\sim}99,\;95{\sim}97,\;99,\;65{\sim}66\;and\;96{\sim}99%$ respectively, in small-scale sewage treatment apparatus.

The Hydraulic simulation and removal characteristics of Escherichia Coli for Ultraviolet rays.Ozone sterilization apparatus (자외선.오존 살균소독장치의 유체시뮬레이션 및 대장균 제거 특성)

  • Hwang, In-Ah;Lee, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.169-172
    • /
    • 2005
  • The simulation of Hydraulic pressure distribution of discharge tube with globular beads and the removal characteristic of Escherichia coli by the discharge tube with globular beads were estimated. The removal characteristic of Escherichia coli was related to the input voltage because the electric field is increased according to input voltage. As the passing amount of test water in discharge tube is increased, the removal ratio of Escherichia coli was increased because passing numbers of electric field section is increased.

  • PDF

Treatment Efficiency of Pollutants in Constructed Wetlands under Different Hydroponic Wastewater Injection Methods and Characteristic of Filter Media (시설하우스 폐양액 주입방법 및 여재 특성에 따른 인공습지에서 수질오염물질의 처리효율)

  • Seo, Dong-Cheol;Park, Jong-Hwan;Cheon, Yeong-Seok;Park, Seong-Kyu;Kim, Ah-Reum;Lee, Won-Gyu;Lee, Sang-Won;Lee, Seong-Tae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.2
    • /
    • pp.146-151
    • /
    • 2010
  • In order to improve T-N and T-P removal in HF (horizontal flow)-HF hybrid constructed wetlands by natural purification method for treating the hydroponic wastewater in greenhouses, the efficiency of water treatment as affected by the injection method of hydroponic wastewater, the addition of special filter media, the particle size of filter media, and the injection ratio of hydroponic wastewater in $1^{st}$ HF and $2^{nd}$ HF beds were investigated in small-scale HF-HF hydroponic wastewater treatment apparatus. Removal rate of T-P in the water in HF-HF hydroponic wastewater treatment apparatus with calcite as affected by addition method of special filter media was higher than that in HF-HF hydroponic wastewater treatment apparatus with other filter media. Removal rate of BOD, COD, SS, T-N and T-P in the water in mixed filter media with calcite were 86, 84, 87, 50 and 97%, respectively. Removals of pollutants except for T-P in the water were slightly different. Therefore, it should be considered that the removal rate of T-P was good for calcite in HF-HF hydroponic wastewater treatment apparatus. To improve T-N and T-P removal, the optimum particle size of filter media was 1.2 mm, and the optimum injection ratio ($1^{st}$ HF bed : $2^{nd}$ HF bed) of hydroponic wastewater was 60:40.

Development of Sewage Treatment Apparatus for Detached House in Agricultural Village by Natural Purification Method (자연정화공법에 의한 농촌 전원 독립가구 하수처리장치 개발)

  • Seo, Dong-Cheol;Park, Mi-Ryoung;Kim, Hyung-Jun;Cho, In-Jae;Lee, Hong-Jae;Sung, Sun-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.202-210
    • /
    • 2006
  • To develop small-scale sewage treatment apparatus for detached house of agricultural village, a small-scale sewage treatment apparatus by natural purification method that consisted of packaged form of aerobic, anoxic and anaerobic bed was constructed. The efficiency of sewage treatment according to the sewage treatment method, sewage loading, and the injection method of sewage were investigated for small-scale sewage treatment apparatus of packaged form of aerobic, anoxic and anaerobic bed. The removal rate of pollutants according to the sewage treatment method for small-scale sewage treatment apparatus was high in the order of aerobic-anoxic-anoxic bed < aerobic-anoxic-anaerobic bed. The optimum filter media in small-scale sewage treatment apparatus was a broken stone. The removal rate of pollutants according to sewage loading in small-scale sewage treatment apparatus was high in the order of $1,200L/m^2{\cdot}day\fallingdotseq900L/m^2{\cdot}day\fallingdotseq600L/m^2{\cdot}day$. The removal rate of pollutants according to injection method of sewage in small-scale sewage treatment apparatus was high in the order of continuous injection $\fallingdotseq$ intermittent injection. When loaded under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P were 99, 95, 99, 83 and 96%, respectively, through this 3-stepped small-scale treatment apparatus arrayed with the order of aerobic, anoxic and anaerobic bed.