• Title/Summary/Keyword: Remote-control

Search Result 2,801, Processing Time 0.036 seconds

Development of a Mobile Tower-yarder with Tractor (I) - Design and Manufacture - (트랙터부착형 타워집재기 개발(I) - 설계 및 제작-)

  • Park, Sang-Jun;Kim, Bo-Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.1
    • /
    • pp.61-70
    • /
    • 2008
  • This study was conducted to develop a mobile tower-yarder with tractor for agriculture and forestry that is the efficient yarder in steep terrains, thinning operation and small scale logging operation. It was designed and manufactured that the power source of tower-yarder is equiped three hydraulic pump connected to PTO of tractor, and three hydraulic pump is used to operate the four motor for drum, the cylinder for clutch of interlocker, the cylinder for tower expanding and the out-rigger cylinder. It was to adopt the running skyline system and the inter-lock function, and to equip the double capstan drum, the storage drum and the clutch for interlock in the development of tower-yarder. It was to develop the tower-yarder which the winch torque of double-capstan drum, the traction force of double-capstan drum, the number of rotation of double-capstan drum and the line speed is $191kg{\cdot}m$, 1,910 kgf, 220.5 rpm and 138.5 m/min, respectively. And it was known that the optimum flange diameter of the main and haulback storage drum is about 360 mm and about 460 mm in order to storage the main line length of 250m and the haulback line length of 450 m. The carriage was made to adopt the running skyline system and to equip the lock function in order to the convenience of chocking and the fall down preventing of tree. It was provided to develop the wire remote controller for the inter-lock function, the convenience of control and the efficiency of yarding. In development process, this tower-yarder was attached the 3-point linkage hitch equipment and the tire wheel for the traction and moving of tower-yarder. Also, it was equipped that the out-rigger and the guy line in order to raise the safety and efficiency of yarding of tower-yarder.

제주도 지하수자원의 최적 개발가능량 선정에 관한 수리지질학적 연구

  • 한정상;김창길;김남종;한규상
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1994.07a
    • /
    • pp.184-215
    • /
    • 1994
  • The Hydrogeologic data of 455 water wells comprising geologic and aquifer test were analyzed to determine hydrogeoloic characteristics of Cheju island. The groundwater of Cheju island is occurred in unconsolidated pyroclastic deposits interbedded in highly jointed basaltic and andesic rocks as high level, basal and parabasal types order unconfined condition. The average transmissivity and specific yield of the aquifer are at about 29,300m$^2$/day and 0.12 respectively. The total storage of groundwater is estimated about 44 billion cubic meters(m$^3$). Average annual precipitation is about 3390 million m$^3$ among which average recharge amount is estimated 1494 million m$^3$ equivalent 44.1% of annual precipitation with 638 million m$^3$ of runoff and 1256 million m$^3$ of evapotranspiration. Based on groundwater budget analysis, the sustainable yield is about 620 million m$^3$(41% of annual recharge)and rest of it is discharging into the sea. The geologic logs of recently drilled thermal water wens indicate that very low-permeable marine sediments(Sehwa-ri formation) composed of loosely cemented sandy sat derived from mainly volcanic ashes, at the 1st stage volcanic activity of the area was situated at the 120$\pm$68m below sea level. And also the other low-permeable sedimentary rock called Segipo-formation which is deemed younger than former marine sediment is occured at the area covering north-west and western part of Cheju at the $\pm$70m below sea level. If these impermeable beds are distributed as a basal formation of fresh water zone of Cheju, most of groundwater in Cheju will be para-basal type. These formations will be one of the most important hydrogeologic boundary and groundwater occurences in the area.

  • PDF

The Impact of Perceived Risks Upon Consumer Trust and Purchase Intentions (인지된 위험의 유형이 소비자 신뢰 및 온라인 구매의도에 미치는 영향)

  • Hong, Il-Yoo B.;Kim, Woo-Sung;Lim, Byung-Ha
    • Asia pacific journal of information systems
    • /
    • v.21 no.4
    • /
    • pp.1-25
    • /
    • 2011
  • Internet-based commerce has undergone an explosive growth over the past decade as consumers today find it more economical as well as more convenient to shop online. Nevertheless, the shift in the common mode of shopping from offline to online commerce has caused consumers to have worries over such issues as private information leakage, online fraud, discrepancy in product quality and grade, unsuccessful delivery, and so forth, Numerous studies have been undertaken to examine the role of perceived risk as a chief barrier to online purchases and to understand the theoretical relationships among perceived risk, trust and purchase intentions, However, most studies focus on empirically investigating the effects of trust on perceived risk, with little attention devoted to the effects of perceived risk on trust, While the influence trust has on perceived risk is worth studying, the influence in the opposite direction is equally important, enabling insights into the potential of perceived risk as a prohibitor of trust, According to Pavlou (2003), the primary source of the perceived risk is either the technological uncertainty of the Internet environment or the behavioral uncertainty of the transaction partner. Due to such types of uncertainty, an increase in the worries over the perceived risk may negatively affect trust, For example, if a consumer who sends sensitive transaction data over Internet is concerned that his or her private information may leak out because of the lack of security, trust may decrease (Olivero and Lunt, 2004), By the same token, if the consumer feels that the online merchant has the potential to profit by behaving in an opportunistic manner taking advantage of the remote, impersonal nature of online commerce, then it is unlikely that the merchant will be trusted, That is, the more the probable danger is likely to occur, the less trust and the greater need to control the transaction (Olivero and Lunt, 2004), In summary, a review of the related studies indicates that while some researchers looked at the influence of overall perceived risk on trust level, not much attention has been given to the effects of different types of perceived risk, In this context the present research aims at addressing the need to study how trust is affected by different types of perceived risk, We classified perceived risk into six different types based on the literature, and empirically analyzed the impact of each type of perceived risk upon consumer trust in an online merchant and further its impact upon purchase intentions. To meet our research objectives, we developed a conceptual model depicting the nomological structure of the relationships among our research variables, and also formulated a total of seven hypotheses. The model and hypotheses were tested using an empirical analysis based on a questionnaire survey of 206 college students. The reliability was evaluated via Cronbach's alphas, the minimum of which was found to be 0.73, and therefore the questionnaire items are all deemed reliable. In addition, the results of confirmatory factor analysis (CFA) designed to check the validity of the measurement model indicate that the convergent, discriminate, and nomological validities of the model are all acceptable. The structural equation modeling analysis to test the hypotheses yielded the following results. Of the first six hypotheses (H1-1 through H1-6) designed to examine the relationships between each risk type and trust, three hypotheses including H1-1 (performance risk ${\rightarrow}$ trust), H1-2 (psychological risk ${\rightarrow}$ trust) and H1-5 (online payment risk ${\rightarrow}$ trust) were supported with path coefficients of -0.30, -0.27 and -0.16 respectively. Finally, H2 (trust ${\rightarrow}$ purchase intentions) was supported with relatively high path coefficients of 0.73. Results of the empirical study offer the following findings and implications. First. it was found that it was performance risk, psychological risk and online payment risk that have a statistically significant influence upon consumer trust in an online merchant. It implies that a consumer may find an online merchant untrustworthy if either the product quality or the product grade does not match his or her expectations. For that reason, online merchants including digital storefronts and e-marketplaces are suggested to pursue a strategy focusing on identifying the target customers and offering products that they feel best meet performance and psychological needs of those customers. Thus, they should do their best to make it widely known that their products are of as good quality and grade as those purchased from offline department stores. In addition, it may be inferred that today's online consumers remain concerned about the security of the online commerce environment due to the repeated occurrences of hacking or private information leakage. Online merchants should take steps to remove potential vulnerabilities and provide online notices to emphasize that their website is secure. Second, consumer's overall trust was found to have a statistically significant influence on purchase intentions. This finding, which is consistent with the results of numerous prior studies, suggests that increased sales will become a reality only with enhanced consumer trust.

Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields (선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션)

  • Jeong Dong Hyeok;Lee Jeong Ok;Kang Jeong Ku;Kim Soo Kon;Kim Seung Kon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.195-202
    • /
    • 1998
  • Purpose : In order to obtain basic data for treatment plan in radiosurgery, we measured small fields of 6 MV X-rays and compared the measured data with our Monte Carlo simulations for the small fields. Materials and Methods : The small fields of 1.0, 2.0 and 3.0 cm in diameter were used in this study. Percentage depth dose (PDD) and beam Profiles of those fields were measured and calculated. A small semiconductor detector, water phantoms, and a remote control system were used for the measurement Monte Carlo simulations were Performed using the EGS4 code with the input data prepared for the energy distribution of 6 MV X-rays, beam divergence, circular fields and the geometry of the water phantoms. Results : In the case of PDD values, the calculated values were lower than the measured values for all fields and depths, with the differences being 0.3 to 5.7% at the depths of 20 to 20.0 cm and 0.0 to 8.9% at the surface regions. As a result of the analysis of beam profiles for all field sizes at a depth of loom in water phantom, the measured 90% dose widths were in good agreement with the calculated values, however, the calculated Penumbra radii were 0.1 cm shorter than measured values. Conclusion : The measured PDDs and beam profiles agreement with the Monte Carlo calculations approximately. However, it is different when it comes to calculations in the area of phantom surface and penumbra because the Monte Carlo calculations were performed under the simplified geometries. Therefore, we have to study how to include the actual geometries and more precise data for the field area in Monte Carlo calculations. The Monte Carlo calculations will be used as a useful tool for the very complicated conditions in measurement and verification.

  • PDF

Packing effects on the intracavitary radiation therapy of the utaine lervix cancer ($^{192}Ir$source를 이용할 자궁경부암 강내치료시 사용하는 packing의 효과에 대한 고찰)

  • Cho, Jung-Kun;Lee, Du-Hyun;Si, Chang-Kun;Choi, Yoon-Kyung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.73-77
    • /
    • 2004
  • Purpose of the radio-therapy is maximize the radiation dose to the tumor while minimizing the dose to the critical organ. Carcinoma of the uterine cervix treatment are external irradiation or an interstitial brachtheraphy make use of isotope. Brachytherapy is a method of radiotherapy in advantage to achieve better local control with minimum radiation toxicity in comparison with external irradiation because radiation dose is distributed according to the inverse square low of gamma-ray emitted from the implanted sources. Authors make use of the patients data which 192Ir gives medical treatment intrcavity. Intracavitary radiation of the uterine cervix cancer, critical organ take $20\%$ below than exposure dose of A point in the ICRU report. None the less of the advice, Radiation proctitis and radiation cystitis are frequent and problematic early complications in patients treated with radiation for the uterine cervix cancer. In brachytherapy of uterine cervical cancer using a high dose rate remote afterloading system, it is of prime importance to deliver a accurate dose in each fractionated treatment by minimizing the difference between the pre-treatment planned and post-treatment calculated doses. Use of packing to reduce late complications intracavitary radiation of the uterine cervix cancer. Bladder and rectum changes exposure dose rate by radiotherphy make use of packing.

  • PDF

The Effects of High Dose Rate Brachytherapy in Recurrent Obstructive Bronchogenic Cancer after External Irradiation Therapy (외부 방사선 치료 조사후 재발한 기관지내 악성종양에서 고선량율 근접조사치료(High Dose Rate Brachytherapy)의 효과)

  • Cho, Jae-Youn;In, Kwang-Ho;Suh, Jung-Kyung;Kang, Sea-Yong;Shim, Jae-Jeong;Kang, Kyung-Ho;Kim, Kwang-Taak;Kim, Cheol-Yong;Yoo, Sa-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.68-76
    • /
    • 1998
  • Background: Patients with centrally recurred bronchogenic carcinoma make a complaint of many symptoms like hemoptysis, cough & dyspnea. At these conditions, the goal of treatment is only to relieve their symptoms. High dose rate brachytherapy(HDR-BT) is the palliative treatment modality of centrally located endobronchial tumor regardless of previous external irradiation(XRT) on the same site in symptomatic patients. Methods: We studied the effects of HDR-BT in 26 patients with symptomatic recurrent lung cancer. Patients(male: 24, mean age: 54yrs)were treated with HDR-BT underwent bronchoscopic placement of $^{192}Ir$ HDR after loading unit(Gammamed$^{(T)}$, Germany) to deliver 500cGY intraluminal irradiation at a depth of 1cm every lwk on 3 occasions. Evaluation at base line and 4wks after HDR brachytherapy included chest X-ray, bronchscopy, symptoms (Standadized Scale for dyspnea,cough,hemoptysis), and Karnofsky performance scale. Results: Endobronchial obstruction was improved in 11/26 patients(37%). Atelectasis in chest X-ray was improved in 5/15 patients(33%). Hemoptysis, dyspnea & cough were improved in 5/10 patients (50%), 5/8 patients (62%) & 10/18 patients (56%) respectively. Karnofsky performance status was changed from 76.4 scores in pretreatment to 77.6 scores after treatment. During HDR-BT, massive hemoptysis (2 patients) and pneumothorax(1 patient) were occurred as complications. Conclusion: We concluded that HDR-BT gave additional benefits for the control of symptoms and general performance and endobronchial obstruction & atelectasis. And HDR-BT will be an additional treatment for the recurrent and endobronchial obstructive lung cancer.

  • PDF

Long-term Climate Change Research Facility for Trees: CO2-Enriched Open Top Chamber System (수목의 장기 기후변화 연구시설: CO2 폭로용 상부 개방형 온실)

  • Lee, Jae-Cheon;Kim, Du-Hyun;Kim, Gil-Nam;Kim, Pan-Gi;Han, Sim-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • The open-top chamber (OTC) system is designed for long term studies on the climate change impact on the major tree species and their community in Korea. In Korea Forest Research Institute (KFRI), the modified OTC system has been operating since September 2009. The OTC facility consists of six decagon chambers (10 meters in diameter by 7 meters high) with controlled gas concentration. In each chamber, a series of vertical vent pipes are installed to disperse carbon dioxide or normal air into the center of the chamber. The OTC is equipped with remote controlled computer system in order to maintain a stable and elevated concentration of carbon dioxide in the chamber throughout the experimental period. The experiment consisted of 4 treatments: two elevated $CO_2$ levels ($1.4{\times}$ and $1.8{\times}$ ambient $CO_2$) and two controls (inside and outdoors of the OTC). Average operational rate was the lowest (94.2%) in June 2010 but increased to 98% in July 2010 and was 100% during January to December 2011. In 2010~2011, $CO_2$ concentrations inside the OTCs reached the target programmed values, and have been maintained stable in 2011. In 2011, $CO_2$ concentrations of 106%, 100% and 94% of target values has been recorded in control OTC, $1.4{\times}$ $CO_2$-enriched OTC and $1.8{\times}$ $CO_2$-enriched OTC, respectively. With all OTC chambers, the difference between outside and inside temperatures was the highest ($1.2{\sim}2.0^{\circ}C$) at 10 am to 2 pm. Temperature difference between six OTC chambers was not detected. The relative humidity inside and outside the chambers was the same, with minor variations (0~1%). The system required the highest amount of $CO_2$ for operation in June, and consumed 11.33 and 17.04 ton in June 2010 and 2011, respectively.

Personalized Recommendation System for IPTV using Ontology and K-medoids (IPTV환경에서 온톨로지와 k-medoids기법을 이용한 개인화 시스템)

  • Yun, Byeong-Dae;Kim, Jong-Woo;Cho, Yong-Seok;Kang, Sang-Gil
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.3
    • /
    • pp.147-161
    • /
    • 2010
  • As broadcasting and communication are converged recently, communication is jointed to TV. TV viewing has brought about many changes. The IPTV (Internet Protocol Television) provides information service, movie contents, broadcast, etc. through internet with live programs + VOD (Video on demand) jointed. Using communication network, it becomes an issue of new business. In addition, new technical issues have been created by imaging technology for the service, networking technology without video cuts, security technologies to protect copyright, etc. Through this IPTV network, users can watch their desired programs when they want. However, IPTV has difficulties in search approach, menu approach, or finding programs. Menu approach spends a lot of time in approaching programs desired. Search approach can't be found when title, genre, name of actors, etc. are not known. In addition, inserting letters through remote control have problems. However, the bigger problem is that many times users are not usually ware of the services they use. Thus, to resolve difficulties when selecting VOD service in IPTV, a personalized service is recommended, which enhance users' satisfaction and use your time, efficiently. This paper provides appropriate programs which are fit to individuals not to save time in order to solve IPTV's shortcomings through filtering and recommendation-related system. The proposed recommendation system collects TV program information, the user's preferred program genres and detailed genre, channel, watching program, and information on viewing time based on individual records of watching IPTV. To look for these kinds of similarities, similarities can be compared by using ontology for TV programs. The reason to use these is because the distance of program can be measured by the similarity comparison. TV program ontology we are using is one extracted from TV-Anytime metadata which represents semantic nature. Also, ontology expresses the contents and features in figures. Through world net, vocabulary similarity is determined. All the words described on the programs are expanded into upper and lower classes for word similarity decision. The average of described key words was measured. The criterion of distance calculated ties similar programs through K-medoids dividing method. K-medoids dividing method is a dividing way to divide classified groups into ones with similar characteristics. This K-medoids method sets K-unit representative objects. Here, distance from representative object sets temporary distance and colonize it. Through algorithm, when the initial n-unit objects are tried to be divided into K-units. The optimal object must be found through repeated trials after selecting representative object temporarily. Through this course, similar programs must be colonized. Selecting programs through group analysis, weight should be given to the recommendation. The way to provide weight with recommendation is as the follows. When each group recommends programs, similar programs near representative objects will be recommended to users. The formula to calculate the distance is same as measure similar distance. It will be a basic figure which determines the rankings of recommended programs. Weight is used to calculate the number of watching lists. As the more programs are, the higher weight will be loaded. This is defined as cluster weight. Through this, sub-TV programs which are representative of the groups must be selected. The final TV programs ranks must be determined. However, the group-representative TV programs include errors. Therefore, weights must be added to TV program viewing preference. They must determine the finalranks.Based on this, our customers prefer proposed to recommend contents. So, based on the proposed method this paper suggested, experiment was carried out in controlled environment. Through experiment, the superiority of the proposed method is shown, compared to existing ways.

Activation plan of social safety network of the aged living alone - Focused on the aged using wireless paging system in Gwangyang-si - (독거노인의 사회안전망에 대한 활성화 방안 - 광양시 무선페이징시스템 대상자 중심으로 -)

  • Lee, Jae-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.3
    • /
    • pp.41-58
    • /
    • 2009
  • Objective : The purpose of this study is to identify actual operations and issues of wireless paging system operation for the aged living alone as the end users of wireless paging system primarily in Gwangyang city, and thereby to explore possible advanced and integrated ways to promote social safety network for the aged. Methods : The survey tool used in this study was a structured questionnaire form consisting of question items. The researcher hereof conducted this survey by means of direct visit and interview during two seasons, i.e. from February to August, 2008 and from December 2008 to March 2009, respectively. Results : 1) For general demographic characteristics, it was found that 90.9% of all respondents were women and 61.2% of all respondents were at age 75 to 84. for health conditions, it was found that more than 90% of all respondents often took medicines due to their unhealthy body, and most of respondents suffered from musculoskeletal diseases 79.3% and circulatory diseases 61.6%. for walking capacity, it was found that 45.5% of all respondents used walking aids, and disable respondents (11.5% of all respondents) were represented primarily by those with physical disability (52.6% of disable respondents). for actual use of medical institutions, it was found 47.3% of all respondents relied on local clinics, since they preferred neighborhood hospitals or clinics they can trust for medical care. for social activities and supports, it was found that 43.6% respondents had 'needs for assistance at times' and 33.9% respondents have 'no need for assistance'. And it was found that the major difficulties in living alone at old age were represented primarily by health problems 37.8% and economic difficulties 33.5%. 2) For characteristics related to wireless paging system, it was found that 90.3% respondents used wireless paging system recommended by firemen, and 28.5% respondents used this system. and it was found that 59.6% respondents used this system once, and 85.2% respondents used it because of acute or chronic diseases. more than 90% respondents thought that they knew about wireless paging system and considered themselves safe, but 83.6% respondents didn't attach a remote control on their upper clothes, and even 49.1% respondents turned off the power of wireless paging system due to their concern about electricity bill and noise. 3) It was found that 83.6% respondents felt it necessary to use wireless paging system, and wireless paging users felt more satisfied with using the system than non-users, and 50.7% showed high satisfaction at certain psychological benefits like 'confidence in coping with critical situations' and 'a sense of relief'. In addition, it was found that some respondents who answered that 'they didn't turn off the paging system as they knew how it works' and those who answered that they knew 'how to use it' showed relatively high satisfaction. And some respondents who kept it well and felt it necessary also showed high satisfaction. 4) It was found that the level of satisfaction our respondents felt with using wireless paging system varied significantly availability($x^{2}$ = 12.759, p = .002), psychological advantages($x^{2}$ = 12.174, p = .002), knowledge about how to use system($x^{2}$ = 7.021, p = .016), power on/off($x^{2}$ = 13.221, p = .001), level of knowledge about system($x^{2}$ = 21.002, p = .000), maintenance($x^{2}$ = 9.871, p = .007) and level of necessity($x^{2}$ = 34.939, p = .000) on the statistical basis.

  • PDF

Evaluation of satellite-based evapotranspiration and soil moisture data applicability in Jeju Island (제주도에서의 위성기반 증발산량 및 토양수분 적용성 평가)

  • Jeon, Hyunho;Cho, Sungkeun;Chung, Il-Moon;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.10
    • /
    • pp.835-848
    • /
    • 2021
  • In Jeju Island which has peculiarity for its geological features and hydrology system, hydrological factor analysis for the effective water management is necessary. Because in-situ hydro-meteorological data is affected by surrounding environment, the in-situ dataset could not be the spatially representative for the study area. For this reason, remote sensing data may be used to overcome the limit of the in-situ data. In this study, applicability assessment of MOD16 evapotranspiration data, Globas Land Data Assimilation System (GLDAS) based evapotranspiration/soil moisture data, and Advanced SCATterometer (ASCAT) soil moisture product which were evaluated their applicability on other study areas was conducted. In the case of evapotranspiration, comparison with total precipitation and flux-tower based evapotranspiration were conducted. And for soil moisture, 6 in-situ data and ASCAT soil moisture product were compared on each site. As a result, 57% of annual precipitation was calculated as evapotranspiration, and the correlation coefficient between MOD16 evapotranspiration and GLDAS evapotranspiration was 0.759, which was a robust value. The correlation coefficient was 0.434, indicating a relatively low fit. In the case of soil moisture, in the case of the GLDAS data, the RMSE value was less than 0.05 at all sites compared to the in-situ data, and a statistically significant result was obtained as a result of the significance test of the correlation coefficient. However, for satellite data, RMSE over than 0.05 were found at Wolgak and there was no correlation at Sehwa and Handong points. It is judged that the above results are due to insufficient quality control and spatial representation of the evapotranspiration and soil moisture sensors installed in Jeju Island. It is estimated as the error that appears when adjacent to the coast. Through this study, the necessity of improving the existing ground observation data of hydrometeorological factors is emphasized.