• Title/Summary/Keyword: Remote power management

Search Result 183, Processing Time 0.023 seconds

Development of the Ubiquitous-based Intelligent Digital Switchgear Panel for Home Automation (유비쿼터스 기반의 주택 자동화용 디지털 분전반 개발)

  • Ko, Yun-Seok;Kim, Ho-Yong;Yun, Seok-Yeul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.741-747
    • /
    • 2008
  • This paper proposes a new concept of IDSP(Intelligent Digital Switchgear Panel) which can solve the problem of the safety, the reliability and the convenience to correspond to the requirement of the general electric customer or electric power company under the ubiquitous-based home automation environments. By analyzing their requirement functions, a 32-bit micro processor is adopted as main controller to support the designed functions efficiently. The DSP-based single phase power management device is utilized to collect the electric power information and the ethernet convertor to communicate through internet among the IDSPs and the remote computer system. In the proposed IDSP, the several functions are implemented such as the earth leakage level display and waveform transmission, the electric fee display, the voltage management, the load management and the load control function. Finally, the prototype of the IDSP is made experimently based on the designed results, and then the effectiveness is verified by testing its basic functions.

Design For System Algorithm for Implement Machine Socialization Environment (DDNS 기반 가정 에너지 관리 시스템 설계)

  • Lee, Chun-Hui;Kim, Wung-Jun;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.629-631
    • /
    • 2015
  • Recently, the actual demand for electricity usage to out of demand forecasting demand appears to be based on the power of Government to address the insecurity is there are a lot of efforts on a more efficient energy management. In 2011, the first major outage, blackout since the current rate of no more than 10% of our power plants, such as power supply and demand crisis is being repeated. In addition, energy management systems, the demand for care and social areas are being expanded. In this paper, Building power supply and wired/wireless router and to optimize the DDNS (Dynamic Domain Name Service) for remote control and monitoring device for electric consumption Presonal Energy Management System offers a way to implement it. In the future, remote control and access the user's can minimize the settings for additional research is needed.

  • PDF

A Study of Broadcasting Facility Remote Management System at Station (도시철도 역사방송설비 원격제어시스템에 관한 고찰)

  • Choi, Yoon-Seog
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2069-2075
    • /
    • 2010
  • The broadcasting system for the customer safety and conveniency is one of the important convenience facilities taking charge of customer guidance, emergency situation broadcasts for the people waiting at the platform, waiting lounge and train approaching broadcasts. To maintain this broadcasting facility local management control system(LMC) is needed. LMC observes operation status of the facility components which is set up at station and the observation results are confirmed through out remote management PC installed in the jurisdiction branch office. The staff only observes and confirms the errors of the electrical power source at broadcasting facility components accordingly the real mechanical troubles are detected by on-the-spot survey. this paper deals with existing broadcasting system only acting as a simple observation function and the research of LMC function extension which controls, monitors and tests broadcasting facility.

  • PDF

The feeder automation using the switches with multi functions (다기능개폐기를 이용한 선로운전자동화)

  • Song, Byong-Kwon;Hong, Soon-Hak;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.183-186
    • /
    • 1992
  • The distribution automation functions include feeder automation, data acquisition and processing, remote meter reading and load management. This report explains the function of feeder automation and the accomplishment method of feeder automation using the switches of distribution system with multi functions.

  • PDF

Suggestion for method to improve power consumption of the ZigBee RF4CE platform

  • Woo, Eun-Ju;Moon, Yu-Sung;Kim, Jung-Won
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.476-479
    • /
    • 2018
  • This paper proposes a method for reducing the amount of current consumption by the transceiver based remote control and the ZigBee RF4CE network layer step. We have studied how to improve power efficiency at short transition time through duty rate management. Also, comparing the measured current consumption before and after the improvement, we confirmed the correlation between the data transmission speed improvement and the current reduction.

Implementations of Remote Sensing, GIS, and GPS for Water Resources and Water Quality Monitoring

  • Wu, Mu-Lin;Chen, Chiou-Hsiung;Liu, Shiu-Feng;Wey, Jiun-Sheng
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1191-1193
    • /
    • 2003
  • Water quantity and quality monitoring at Taipei Watershed Management Bureau (WRATB) is not only a daily business but also a long term job. WRATB is responsible for providing high quality drinking water to about four millions population in Taipei. The quality of drinking water provided by WRATB is among one of the best in Taiwan. The total area is 717 square kilometers. The water resource pollution is usually divided into two categories, point source pollution and nonpoint source pollution. Garbage disposal is the most important component of the point source pollution, especially those by tourist during holidays and weekends. Pesticide pollution, fertilizer pollution, and natural pollution are the major contributions for nonpoint source pollution. The objective of this paper is to implement remote sensing, geographic information systems, and global positioning systems to monitor water quantity and water quality at WRATB. There are 12 water quality monitoring stations and four water gauge stations at WRATB. The coordinates of the 16 stations were determined by GPS devices and created into the base maps. MapObjects and visual BASIC were implemented to create application modules for water quality and quantity monitoring. Water quality of the two major watersheds at WRATB was put on Internet for public review monthly. The GIS software, ArcIMS, can put location maps and attributes of all 16 stations on Internet for general public review and technical implementations at WRATB. Inquiry and statistic charts automatic manipulations for the past 18 years are also available. Garbage disposal by community and tourist were also managed by GIS and GPS. The storage, collection, and transportation of garbage were reviewed by ArcMap file format. All garbage cart and garbage can at WRATB can be displayed on the base maps. Garbage disposal by tourist during holidays and weekends can be managed by a PDA with a GPS device and a digital camera. Man power allocation for tourist garbage disposal management can be done in an integration of GIS and GPS. Monitoring of water quality and quantity at WRATB can be done on Internet and by a PDA.

  • PDF

Implementation of a DCS Terminal Remote Monitoring Middleware using RF Communication (RF 통신을 이용한 DCS 터미널 원격 감시 미들웨어 구현)

  • Ha, Jong-Hyun;Choi, Seong-Kyou;Rho, Ju-Yong;Jung, Heon-Man;Lee, Se-Hoon
    • KSCI Review
    • /
    • v.14 no.2
    • /
    • pp.129-134
    • /
    • 2006
  • In this paper, we designed and implemented DCS terminal remote monitoring middleware for real-time auditor and management terminal status signal with relay and fuse status at power management room. The middleware consist of four component as event analyzer, event manager, service manager and user interface. We expected economic effects extend relay life-time that pre-detected errors and prevented relay fault.

  • PDF

A developement of Remote Monitoring & Control System using SNMP for UPS (SNMP를 이용한 UPS 원격 감시 제어 시스템)

  • Lee, Soo-Byeong;Kim, Dong-Uk;Kim, Yun-Poong;Shin, Hyun-Joo;Ryu, Seung-Pyo;Min, Byoung-Gwon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.381-383
    • /
    • 1999
  • In this paper a remote monitoring and control system using SNMP(Simple Network Management Protocol) for UPS (Uninterruptible Power Supply) systems is proposed. The local remote system by RS-232 or RS-485 communication code or the wide remote system by modems is used for conventional remote monitoring & control system for UPSs. But recently because of communication cost and long distance the system is changed to remote control systems through internet and information communication network. And serial communication method by RS-232 or RS-485 is used between agent and UPSs. In this study. we designed and developed the system which is able to control UPSs and to monitor errors. statuses and actual values transmitted from UPS through internet.

  • PDF

Development of Multi-Touch/Context-Aware Convergence Digital Signage System based on Android OS Platform (안드로이드 플랫폼 기반 멀티 터치/상황인지형 융복합 디지털 사이니지 시스템 개발)

  • Nahm, Eui-Seok
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.245-251
    • /
    • 2015
  • If a digital signage system is operated in PC mounted in the Window OS then the implementing price is very high. For resolving this problem, we used the Smartphone mounted in ARM Cortex family of multi-core processor-based mobile platform. We developed a low-power low-cost digital signage system and a remote convergence content management program based on web server. This convergence system manages advertising content to a remote control device anywhere using remote control technology. This system is one integrated system with display and is a low-power consumed and is developed in very efficient hardware interface. And condition sensors(intensity of illumination, temperature, weather, GPS etc) is equipped in the developed system. Automatic contents builder and Context-aware SMIL module is also implemented in the convergence system. We achieved over 50% power savings comparing with conventional Window OS system and 16 points multi-touch in our system.

A study on the street security light management system using Zigbee network (지그비 통신망을 이용한 보안등 관제 시스템에 관한 연구)

  • Jeon, Joong Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.430-436
    • /
    • 2014
  • This paper relates to the study about the street security light management system. The purpose of the wireless remote management system is to manage street security lights efficiently. The system is composed of three components like light controller, CDMA gateway and web based remote management server. The zigbee solution is adopted to make local wireless network between street security lights. The CDMA network is used for the wireless communication between street security light controller and the remote control center. The gateway to interconnect zigbee network and CDMA was designed with low power 32 bits Cortex M3 micro-controller. For the data communication between the management server and the gateway, SMS and socket based TCP streaming is used. The management server sends SMS to the gateway to deliver light control and management requests, and the gateway replies with the light controllers report via TCP streaming. By using both SMS and TCP streaming communication, it was verified that simple cost effective management is possible for street security lights. We tried real test for 95 street security lights in real environment during two months and analyzed the practical possibility for mass supply.