• Title/Summary/Keyword: Remanent flux

Search Result 48, Processing Time 0.035 seconds

Analysis of Transformer Inrush Current Using Wavelet Transform (Wavelet 변환을 이용한 여자돌입현상 해석)

  • Sohn, J.M.;Kang, Y.C.;Nam, S.R.;Kim, S.S.;Park, J.K.;Kang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.920-923
    • /
    • 1997
  • This paper describes the analysis of characteristics of inrush current in transformers using wavelet transform. The simulations are performed with various transformer conditions, including transformer switching-on angles and the remanent flux. The ratio between wavelet coeffients is used for analysis.

  • PDF

Effects of Oxidant on the Properties of Sr-ferrites Using Mill Scale (밀 스케일을 사용한 Sr-페라이트의 특성에 미치는 산화제의 영향)

  • Cho, Tae-Sik;Choi, Seung-Duek
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.2
    • /
    • pp.131-135
    • /
    • 2011
  • We have been studied the effects of oxidant on the properties of Sr-ferrite magnets using mill scale for motor. The small-added (0.5 wt%) $NaNO_3$ oxidant improved significantly the degree of oxidation and the grindability of mill scale, and then highly enhanced the magnetic properties of anisotropic Sr-ferrite sintered magnets; such as the remanent flux density from 3.55 to 3.80 kG, the intrinsic coercivity from 2.75 to 3.22 kOe, and the maximum energy product from 2.90 to 3.45 MGOe.

Study on the magnetic porcelain materials (자성을 나타내는 도자기 소지의 연구)

  • Cho, Tae-Sik;Kim, Ji-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.88-91
    • /
    • 2003
  • The magnetic porcelain materials were studied by using the porcelain materials added Sr-ferrite powders before forming and firing process. For the high magnetic property, the Sr-ferrite magnetic powders with the grain size of 1 ${\mu}m$ were agglomerated the powder size of about 1 mm. The magnetic porcelain with 30 wt% of Sr-ferrite powders indicated the magnetic characteristics such as the remanent flux density of 240 G and the intrinsic coercivity of 3910 Oe, at the firing conditions of $1250^{\circ}C$/1hr in air.

  • PDF

A Current Differential Relaying Algorithm for Transmission Lines Using an Advanced Compensation Algorithm of CTs (보상알고리즘을 적용한 송전선 보호용 전류차동 알고리즘)

  • Kang, Y.C.;Lim, U.J.;Choi, J.W.;Jin, S.Y.;Cho, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.323-325
    • /
    • 2003
  • A current differential relay may maloperate for external faults with CT saturation and requires an additional method to cope with the problem. This paper proposes a current differential relaying algorithm for transmission line protection using an advanced compensation algorithm of the secondary current of CTs. The compensation algorithm is unaffected by a remanent flux. The proposed algorithm does not need an additional method for CT saturation and thus can achieve high stability for an external fault.

  • PDF

A Transformer Protection Relay Based on Induced Voltages

  • Kang, Yong-Cheol;Lee, Byung-Eun
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.2
    • /
    • pp.70-78
    • /
    • 2003
  • This paper describes a transformer protection relay based on induced voltages. The ratio of the induced voltages of the primary and secondary windings is equal to the turns ratio during normal operating conditions such as magnetic inrush, overexcitation, and steady state, but it differs from the turns ratio in the case of internal faults. For a single-phase and a three-phase Y-Y transformer, the induced voltages are estimated and the ratios are compared with the turns ratio. For three-phase Y-Δ transformers, the differences between the induced voltages are estimated to use the line currents because delta-winding currents are practically unavailable. The proposed relay is tested under various conditions such as magnetic inrush, internal winding faults, overexcitation, and different core characteristics. The results evidently indicate that the relay successfully discriminates internal faults from magnetic inrush and overexcitation. This paper concludes by implementing the relay into a TMS320C6701 digital signal processor and reports satisfactory results. The relay requires no hysteresis data and can reduce the operating time of a relay.

A Current Compensation Algorithm for a CT Saturation (CT 포화 복원 알고리즘)

  • Yi, Xiao-Li;Kang, Sang-Hee;Lee, Dong-Gyu;Kang, Yong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.88-90
    • /
    • 2003
  • In this paper, an algorithm to compensate the distorted signals due to CT(Current Transformer) saturation is suggested. Firstly, WT(Wavelet Transform) is used to detect a start point and an end point of saturation. Filter banks which can be easily realized in real-time applications are employed in detecting CT saturation. Secondly, least-square curve fitting method is used to restore the distorted section of the secondary current. Fault simulations are performed on a power system model using EMTP(Electromagnetic Transient Program). A series of test results indicate that WT has superior detection accuracy and the proposed algorithm which shows very stable features under various levels of remanent flux is also satisfactory.

  • PDF

Study on Heterogeneous Structures and High-Frequency Magnetic Properties Amorphous CoZrNb Thin Films (비정질 CoZrNb 박막의 불균일 구조와 고주파 자기특성에 관한 연구)

  • 정인섭;허재헌
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.31-36
    • /
    • 1991
  • Structural and compositional heterogeneities of sputter deposited, amorphous $Co_{87}Zr_{4}NB_{9}$ thin films were investigated using TEM and EDS with windowless detector. The films deposited with substrate bias and annealed in rotating magnetc field showed two amorphous phases of Co-rich region and (ZrNb)oxide-rich region, and revealed 'ultra-soft' magnetic properties. Revesible bias-responses and overdamped frequency responses, along with small Hc, Hk and Mr/Ms ratio, give the possibility of ultra-soft magnetic behavior fo CoZrNb thin films. We proposed the vortex type magnetization distribution in remanent state which was correlated with the thin film heterogeneity. Then, the ultra-soft characteristics of the compositionally heterogeneous films were explained by the spin vortices that minimized the total magnetostatic and exchange coupling energies.

  • PDF

Fabrication of the Alnico Bonded Magnets for Measuring Instruments and its Magnetic Properties (계측기용 알니코 본드자석의 제조 및 자기 특성연구)

  • Kim, Jung Sik
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.1
    • /
    • pp.85-91
    • /
    • 2011
  • Alnico magnets can be used as magnetic bearings for the precise electric power measuring instruments such as watt-hour meters because they have high remanence ($B_r$), relatively high maximum energy product ($(BH)_{max}$), and excellent temperature stability. In this study, Alnico composite magnets were fabricated by appropriately mixing alnico alloy powders with epoxy resin and binder. The Alnico powders mixed with epoxy resin and a hardening agent with a mixing ratio of 96:4 were pressed and then cured to be a toroid-type ring magnet with an outer diameter (${\Phi}_{out}$) of 15 mm, an inner diameter (${\Phi}_{in}$) of 6.5 mm and a thickness (t) of 2.5 mm, respectively. The magnetic properties of the Alnico ring magnets were varied with the mixing ratio of Alnico powders that possess different average particle sizes. The Alnico ring magnet prepared by mixing 5 wt% of $50{\mu}m$ (small size) powder, 15~20 wt% of $150{\mu}m$ (medium size) powder, and 75~80 wt% of $300{\mu}m$ (large size) powder showed the best magnetic properties (remanent induction, coercive force, maximum energy product, and surface flux density). In addition, measurements of temperature and moisture characteristics for the Alnico ring magnets showed that the surface flux densities of the N and S poles decreased little and the repulsive distance between the magnets decreased as small as 0.05 mm after 10 days.

Analysis of the response of a distance relay considering the errors of CT and CCVT (CT와 CCVT의 오차를 고려한 거리 계전기의 응동 분석)

  • Kang, Yong-Cheol;Zhang, Tai-Ying;Choi, Jae-Sun;Kang, Hae-Gweon;Kim, Kwang-Moo;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.12-15
    • /
    • 2008
  • A distance relay has been widely used for transmission line protection. The distance relay detects a fault based on the calculated impedance i.e. the ratio of the voltage to the current measured from a current transformer (CT) and a coupling capacitor voltage transformer (CCVT), respectively. When a fault occurs and a CT saturates due to the magnitude of fault current, dc component, primary time constant, and the remanent flux of the iron core, the secondary current of a CT is distorted On the other hand, non-fundamental components generated during a fault can increase the error of a CCVT, particularly when a fault distance is short. The distortion of the current and voltage can cause mal-operation or the operating time delay of a distance relay. This paper describes the response of a distance relay considering the errors of a CT and a CCVT. The results indicate that the severe distortion of a CT and a CCVT have noticeable effect to a distance relay.

  • PDF

A Compensated Current Acqaisition Device for CT Saturation (왜곡 전류 보상형 전류 취득 장치)

  • Ryu, Ki-Chan;Gang, Soo-Young;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.96-98
    • /
    • 2005
  • In this paper, an algorithm to compensate the distorted signals due to Current Transformer(CT) saturation is suggested, First, DWT which can be easily realized by filter banks in real-time applications is used to detect a start point and an end point of the saturation. Secondly, For enough Datas those need to use the least-square curve fitting method, the distorted current signal is compensated by the AR(autoregressive) model using the data during the previous healthy section until pick point of Saturation. Thirdly, the least-square curve fitting method is used to restore the distorted section of the secondary current. Finaly, this algorithm had a Hadware test using DSP board(TMS320C32) with Doble test device. DWT has superior detection accuracy and the proposed compensation algorithm which shows very stable features under various levels of remanent flux in the CT core is also satisfactory. And this algorithm is more correct than a previous algorithm which is only using the LSQ fitting method. Also it can be used as a MU involving the compensation function that acquires the second data from CT and PT.

  • PDF