• 제목/요약/키워드: Remaining Teeth

검색결과 296건 처리시간 0.026초

Effect of 38% carbamide peroxide on the microleakage of silorane-based versus methacrylate-based composite restorations

  • Hashemi Kamangar, Sedighe Sadat;Ghavam, Maryam;Mahinfar, Nazanin;Pourhashemi, Seyed Jalal
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.172-179
    • /
    • 2014
  • Objectives: This study aimed to assess the effect of 38% carbamide peroxide on the microleakage of class V cavities restored with either a silorane-based composite or two methacrylate-based composites. Materials and Methods: A total of 96 class V cavities were prepared on the buccal surface of extracted human teeth with both enamel and dentin margins and were randomly assigned into three groups of Filtek P90 (3M-ESPE) + P90 system adhesive (3M-ESPE)(group A), Filtek Z250 (3M-ESPE) + Adper Prompt L-Pop (3M-ESPE)(group B) and Filtek Z350XT (3M-ESPE) + Adper Prompt L-Pop (group C). Half of the teeth were randomly underwent bleaching (38% carbamide peroxide, Day White, Discus Dental, applying for 15 min, twice a day for 14 day) while the remaining half (control) were not bleached. Dye penetration was measured following immersion in basic fuchsine. Data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests at a level of 0.05. Results: No significant differences were found between composites in the control groups in enamel (p = 0.171) or dentin (p = 0.094) margins. After bleaching, microleakage of Z250 (in enamel [p = 0.867] or dentin [p = 0.590] margins) and Z350 (in enamel [p = 0.445] or dentin [p = 0.591]margins) did not change significantly, but the microleakage of P90 significantly increased in both enamel (p = 0.042) and dentin (p = 0.002) margins. Conclusions: No significant differences were noted between the bleached and control subgroups of two methacrylate-based composites in enamel or dentin margins. Microleakage of silorane-based composite significantly increased after bleaching.

상악 완전 무치악에서 $Locator^{(R)}$ attachment가 장착된 milled titanium bar를 이용한 임플란트 지지 피개의치: 증례 보고 (Implant Supported Overdenture using Milled Titanium Bar with $Locator^{(R)}$ Attachment on Fully Edentulous Maxillae : A Case Report)

  • 오상천;한지석;김민정
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.223-231
    • /
    • 2011
  • 본 증례 보고의 목적은 상악 무치악 환자에서 임플란트 지지 피개의치를 위한 $Locator^{(R)}$ attachment가 장착된 새로운 milled titanium bar를 소개하고 새로운 대안으로써의 가능성을 제시하고자 함이다. 56세 남자 환자가 상악 고정성 보철물(10-유닛 브릿지)의 동요도를 주소로 본원에 내원하였다. 악관절 및 치과 치료에 영향을 줄만한 특이한 전신병력은 없었다. 방사선 검사 및 임상 검사 결과, 상악의 경우 모든 잔존치아에서 심한 골흡수와 동요도를 보이고 있어 전악 발치를 시행한 후, 임플란트 지지 피개의치를 제작하기로 하였다. 의치의 안정성과 유지력, 저작효율, 청소의 용이성, 심미성과 발음 그리고 경제적인 측면을 고려하여 $Locator^{(R)}$ 어태치먼트를 CAD/CAM으로 제작된 milled titanium bar에 탭핑(tapping)으로 연결시키는 새로운 디자인을 고안하였으며, 1년 이상 경과 후, 기능과 심미적인 면에서 만족할 만한 성과를 얻었기에 이를 보고하는 바이다.

심한 마모를 보이는 환자에서의 자연치 피개의치 수복증례 (Overdenture treatment in patient with severely worn dentition: a case report)

  • 김민지;김준엽;양홍서;임현필;윤귀덕;박찬;신진호;박상원
    • 구강회복응용과학지
    • /
    • 제32권4호
    • /
    • pp.307-313
    • /
    • 2016
  • 심한 마모를 보이는 환자에서 자연치를 이용한 피개의치는 하나의 치료 방법이 될 수 있다. 자연치를 이용한 피개의치는 치조골의 보존, 감각수용기능의 유지를 가능하게 하며 강한 지지를 제공한다. 또한 지대치와 의치 지지조직에 가해지는 응력집중을 분산시키며, 의치에 의한 이차고정으로 장기간의 안정성을 제공해줄 수 있다는 장점이 있다. 본 증례는 심한 마모와 우식으로 인해 소수 건전치를 가지는 환자에서 자연치 피개의치를 이용하여 수복한 증례로 심미적, 기능적으로 만족스러운 결과를 얻었기에 보고하는 바이다.

치아교정장치환자의 신체상 및 자기 존중감에 관한 연구 (A study of the correlation between body image and self-respect of patients who have teeth braces)

  • 윤영숙;정영희
    • 한국치위생학회지
    • /
    • 제4권1호
    • /
    • pp.81-91
    • /
    • 2004
  • The ultimate purpose of this study is to provide the basic data for effective intervention of the patients complaining of their aspects and themselves and to help dental hygienists of keep them remaining healthy effectively. The data was collected by questions from 269 people including the outpatients requiring regular care from dental clinic from December 10, 2003 to January 10, 2004. Secord & Jourard's apparatus which measures the degree of self-satisfaction to the body image and Rosenberg's equipment measuring the degree of self-respect were used for this study. The data were analysed using a computerized program named statistical package for social science including t-test, ANOVA and Pearson-correlation coefficient. The result's of this study were summarized as follows: 1. The body image and the sense of self-respect were decided by the various characters of the inquired person. Comparing the inquired person's body image in terms of general background, they showed a big difference in sociability(p=0.004), age(p=0.003), sex(p=0.043). However the experience accident any and the frequency of visiting dental clinic had little effect on deciding their body image. Comparing the self-respect. in terms of the general background, they showed a significant. difference in sociability(p=0.002), age(p=0.041), experience of any accident(p=0.012), whereas age, sex, religion, the frequency of having treatment didn't show any difference with them. 2. The relationship between the score of their body image and the sense of self-respect was positively correlated(r=0.391, p=0.000).

  • PDF

Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator

  • Uzunoglu, Emel;Eymirli, Ayhan;Uyanik, Mehmet Ozgur;Calt, Semra;Nagas, Emre
    • Restorative Dentistry and Endodontics
    • /
    • 제40권1호
    • /
    • pp.44-49
    • /
    • 2015
  • Objectives: This study compared the ability of several techniques to remove calcium hydroxide (CH) from the root canal and determined the influence of CH residues on the accuracy of the electronic apex locator. Materials and Methods: Root canals of 90 human maxillary lateral incisors with confirmed true working length (TWL) were prepared and filled with CH. The teeth were randomly assigned to one of the experimental groups according to the CH removal technique (n = 14): 0.9% saline; 0.9% saline + master apical file (MAF); 17% ethylenediamine tetraacetic acid (EDTA); 17% EDTA + MAF; 5.25% sodium hypochlorite (NaOCl); 5.25% NaOCl + MAF. Six teeth were used as negative control. After CH removal, the electronic working length was measured using Root-ZX (Morita Corp.) and compared with TWL to evaluate Root-ZX accuracy. All specimens were sectioned longitudinally, and the area of remaining CH (CH) and total canal area were measured using imaging software. Results: The EDTA + MAF and NaOCl + MAF groups showed better CH removal than other groups (p < 0.05). Root-ZX reliability to prevent overestimated working length to be > 85% within a tolerance of ${\pm}1.0mm$ (p < 0.05). There was strong negative correlation between amount of CH residues and EAL accuracy (r = -0.800 for ${\pm}0.5mm$; r = -0.940 for ${\pm}1.0mm$). Conclusions: The mechanical instrumentation improves the CH removal of irrigation solutions although none of the techniques removed the dressing completely. Residues of CH medication in root canals affected the accuracy of Root-ZX adversely.

Effects of applying antioxidants on bond strength of bleached bovine dentin

  • Whang, Hyo-Jin;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • 제40권1호
    • /
    • pp.37-43
    • /
    • 2015
  • Objectives: Some antioxidants are believed to restore dentin bond strength after dental bleaching. This study was done to evaluate the influence of antioxidants on the bond strength of bleached bovine dentin. Materials and Methods: Thirty incisors were randomly assigned to 10 groups (two unbleached control and eight bleached groups:immediate bonding IB, 4 wk delayed bonding DB, 10% sodium ascorbate treated SA, 10% ${\alpha}$-tocopherol treated TP groups). Teeth in half of groups were subjected to thermal stress, whereas the remaining groups were not. Resin-dentin rods with a cross-sectional area of $2.25mm^2$ were obtained and microtensile bond strength was determined at a crosshead speed of 1 mm/min. Fifteen specimens were prepared for SEM to compare the surface characteristics of each group. The change in dentin bond strength from thermal stress and antioxidant treatment was evaluated using two-way analysis of variance (ANOVA) and Sheffe's post hoc test at a significance level of 95%. Results: The control group exhibited the highest bond strength values, whereas IB group showed the lowest value before and after thermocycling. The DB group recovered its bond strength similar to that of the control group. The SA and TP groups exhibited similar bond strength values with those of the control and DB groups before thermocycling. However, The TP group did not maintain bond strength with thermal stress, whereas the SA group did. Conclusions: Applying a 10% sodium ascorbate solution rather than 10% ${\alpha}$-tocopherol solution for 60 sec is recommended to maintain dentin bond strength when restoring non-vitally bleached teeth.

Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study

  • Nikbin, Ava;Kajan, Zahra Dalili;Taramsari, Mehran;Khosravifard, Negar
    • Imaging Science in Dentistry
    • /
    • 제48권4호
    • /
    • pp.245-254
    • /
    • 2018
  • Purpose: To assess the effects of object position in the field of view (FOV) and application of a metal artifact reduction (MAR) algorithm on the diagnostic accuracy of cone-beam computed tomography (CBCT) for the detection of vertical root fractures(VRFs). Materials and Methods: Sixty human single-canal premolars received root canal treatment. VRFs were induced in 30 endodontically treated teeth. The teeth were then divided into 4 groups, with 2 groups receiving metal posts and the remaining 2 only having an empty post space. The roots from different groups were mounted in a phantom made of cow rib bone, and CBCT scans were obtained for the 4 different groups. Three observers evaluated the images independently. Results: The highest frequency of correct diagnoses of VRFs was obtained with the object positioned centrally in the FOV, using the MAR algorithm. Peripheral positioning of the object without the MAR algorithm yielded the highest sensitivity for the first observer (66.7%). For the second and third observers, a central position improved sensitivity, with or without the MAR algorithm. In the presence of metal posts, central positioning of the object in the FOV significantly increased the diagnostic sensitivity and accuracy compared to peripheral positioning. Conclusion: Diagnostic accuracy was higher with central positioning than with peripheral positioning, irrespective of whether the MAR algorithm was applied. However, the effect of the MAR algorithm was more significant with central positioning than with peripheral positioning of the object in the FOV. The clinical experience and expertise of the observers may serve as a confounder in this respect.

전치의 심미치료를 위해 투명교정장치를 사용한 다각적 진료접근법 (An interdisciplinary approach to Esthetic anterior restorative treatment with clear aligner orthodontics)

  • 김도훈
    • 대한심미치과학회지
    • /
    • 제32권2호
    • /
    • pp.36-45
    • /
    • 2023
  • 심미적인 전치부의 모습은 자연스럽고 건강한 미소를 위한 필수요건이며 대인관계의 자신감을 위해서도 중요한 요소이다. 전치부의 총생이=나 전돌이 존재하는 경우 단기간에 해결하기 위해 근관치료 및 과도한 치아삭제가 요구되는 경우가 많다. 하지만 이런 술식은 지속가능한 심미적 결과를 만들기 어렵다. 이런 경우 교정치료가 병행되어야만 수복이 필요한 치아들도 잔존 치질을 최대한 보존할 수 있을 것이다. 중장년층 환자들의 경우 교정 치료의 필요성을 절감하면서도 사회적 시선을 의식하여 브라켓을 이용한 전통적 방식의 교정치료 방법을 주저하는 경우가 많다. 이런 경우 투명교정장치는 좋은 선택지가 될 수 있다. 이에 투명교정만으로 심미적 요구를 해결한 증례와, 투명교정을 동반한 새로운 수복치료를 통해 만족스러운 결과를 얻은 다른 증례를 보고한다.

청소년기 외상으로 인한 상악 전치부 파절 시 Endocrown을 이용한 수복: 증례 보고 (Rehabilitation using endocrown for fracture of maxillary anterior teeth due to trauma in adolescence: a case report)

  • 이소연;손성애;박정길
    • 구강회복응용과학지
    • /
    • 제40권1호
    • /
    • pp.24-30
    • /
    • 2024
  • 청소년기 외상으로 인한 상악 전치부의 복잡 치관 파절은 기능적, 심미적 문제를 야기할 수 있다. 치수 노출을 동반한 치관 파절은 남아있는 치질의 양에 따라 다양한 수복 방법을 고려할 수 있다. 직접 레진 수복은 가장 일차적으로 고려되는 전통적이고 효과적인 방법이나 시간이 지남에 따라 변색되고 깨질 가능성이 높다. 전장관 수복은 성장기의 치아 이동으로 변연 부조화에 의한 재수복 가능성이 높으며 광범위한 치관 파절 시 주로 시행하는 포스트 수복은 치근 천공 및 치근 파절의 위험성을 증가시킨다. 그러나 Endocrown은 치수강 공간으로부터 유지력을 얻을 수 있는 일체형 구조로 생체역학적 측면에서 효과적인 재건이 가능하고 기능과 심미성의 회복에 유리한 이점을 제공한다. 따라서 Endocrown은 청소년기 외상으로 인한 복잡 치관 파절의 수복 방법으로 고려할 수 있다.

실패한 고정성 임플란트 보철물을 제거 후 임플란트 융합 가철성 국소의치로 전환 치료한 증례 (A conversion to implant assisted removable partial denture in failed fixed implant prosthesis of mandible: A case report)

  • 진승리;정창모;윤미정;허중보;이현종;이소현
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.161-168
    • /
    • 2020
  • 임플란트 고정성 보철물의 실패는 과도한 교합스트레스와 같은 생역학적인 요인과 세균 감염, 염증과 같은 생물학적인 요인으로 인하여 일어난다. 임플란트 합병증으로 인한 문제가 해결되지 않고 악화되어 심한 골흡수가 일어난 임플란트는 제거되어야 하며, 제거 후 잔존 치아와 잔존 임플란트 및 잔존 치조제를 고려하여 새로운 치료를 계획해야 한다. 본 증례의 환자는 하악 무치악부에 약 10년 전 식립한 하악 고정성 임플란트 보철물 중 일부를 임플란트 주위염으로 인하여 제거하게 되었다. 추가 임플란트 재식립을 위한 잔존 치조골의 상태를 재평가 하고 소수의 임플란트를 추가 식립 후 임플란트 서베이드 크라운을 지대치로 하는 임플란트 융합 가철성 국소의치로 최종 치료하였다. 이를 통해 실패 이후 저작기능을 다시 회복하고 구강위생 관리에 유리한 조건으로 전환하였기에 이를 보고하고자 한다.