• Title/Summary/Keyword: Remained thickness

Search Result 152, Processing Time 0.029 seconds

The Initial Film Flow Development of the High-Pressure Swirl Spray (고압스월분무 액막유동의 초기 발달과정에 대한 연구)

  • Moon, Seok-Su;Abo-Serie, Essam;Choi, Jae-Joon;Bae, Choong-Sik
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.212-219
    • /
    • 2006
  • The initial film flow development of the high-pressure swirl spray was investigated at different injector operating conditions to analyze film flow development and to provide the input data for the modeling works. This result can be also useful to verify the previously simulated results. The initial flow conditions such as liquid film thickness, flow angle and flow divergence are obtained by visualizing the inside and near the nozzle flow with a microscopic imaging system. The visualized images are quantified using an image processing tool. From the information of liquid film thickness and flow angle, the initial axial and tangential velocity and the swirl number of the swirl spray are successfully determined at various operating conditions. The experimental results showed that the initial liquid film thickness, flow angle and flow divergence are remained constant when the injection pressure is increased. However, initial film conditions are severely changed when the fuel temperature is increased. The swirl number remained constant when the injection pressure is increased while it showed increased value at high fuel temperature condition.

  • PDF

Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study

  • Palone, Mario;Longo, Mattia;Arveda, Niki;Nacucchi, Michele;De Pascalis, Fabio;Spedicato, Giorgio Alfredo;Siciliani, Giuseppe;Lombardo, Luca
    • The korean journal of orthodontics
    • /
    • v.51 no.2
    • /
    • pp.135-141
    • /
    • 2021
  • Objective: To assess the effects of thermoforming on aligner thickness and gap width in six aligner systems with the same nominal thickness. Methods: Six passive upper aligners of different brands were adapted to a single printed cast. Each sample was evaluated with high-resolution micro-computed tomography. To investigate aligner thickness and gap width, two-dimensional (2D) analysis was conducted assessing the effects of the following variables: tooth type (central incisor, canine, and first molar), 2D reference points, and aligner type. Data were analyzed and compared using analysis of variance and Tukey's post-hoc tests (p < 0.05). Results: Tooth type, dental region, and aligner type affected both the gap width and aligner thickness. The aligner thickness remained moderately stable across the arch only in the F22. Conclusions: All thermoformed samples displayed smaller aligner thickness and gap width at anterior teeth and both gingival and coronal centers than at posterior teeth and occlusal surfaces.

Echocardiographic Findings after Mitral Valve Replacement (승모판막치환수술 전후 심장초음파 소견의 변화에 관한 연구)

  • 이상진
    • Journal of Chest Surgery
    • /
    • v.27 no.8
    • /
    • pp.656-663
    • /
    • 1994
  • Evaluation of heart function is of importance in assessing the results of valvular heart surgery. Information on volume and functional change of heart chamber can be obtained by cardiac catheterization and echocardiography. We studied 41 patients with mitral stenosis[MS] and 23 patients with mitral regurgitation[MR] using M-mode echocardiography before and after mitral valve replacement[MVR] at Pusan Paik Hospital. Preoperative cardiac catheterization was available in 56 cases, and the results were obtained as follows. 1. In patients with MS, preoperative average LV end-diastolic dimension[EDD] and end-systolic dimension[ESD] were remained within normal range, but postoperative EDD and ESD were significantly decreased[P<0.01]. The preoperative and postoperative LV ejection fraction[EF] were remained within the normal range and no significant change[P>0.05]. The preoperative left atrial dimension[LAD] was enlarged considerably above normal[P<0.01], but was significantly decreased after surgery[P<0.001]. The preoperative LV posterior wall thickness[PWTh] was within normal range, and no significant change after surgery[P>0.05]. 2. In patients with MR, preoperative average end-diastolic dimension[EDD] and end-systolic dimension[ESD] were significantly greater than normal[P<005], but postoperative EDD and ESD were significantly decreased[P<0.01]. The preoperative LV ejection fraction[EF] and fractional shortening[FS] were within normal range, and no significant change after surgery[P>0.05].The preoperative left atrial dimension[LAD] was enlarged considerably above normal [P<0.01], but was significantly decreased after surgery[P<0.001].The preoperative LV posterior wall thickness[PWTh] was within normal range, and no significant change after surgery[P>0.05].

  • PDF

Two Cases of Auricular Salvage after Wide Excision of Malignant Tumor at Periauricular Area (이개 주변 악성종양의 광범위절제술 후 이개의 보존 2례)

  • Kim, Kyul-Hee;Chung, Chul-Hoon;Chang, Yong-Joon;Lee, Jong-Wook;Rho, Young-Soo;Kim, Chang-Woo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.25 no.1
    • /
    • pp.39-42
    • /
    • 2009
  • Wide excision for curative treatment of malignant tumor on periauricular area often leads to loss of the external ear. But the auricle has rich vascular supply, Conservation of auricular contour is possible through salvage and engineering of remained auricular tissue. We experienced two cases of auricular salvage after wide excision of malignant tumor. In the first case, we performed two-staged technique. In first step, we covered soft tissue defect on periauricualr area with the anterolateral thigh free flap and remained auricle was floating over the flap after split-thickness skin graft was applied on it's posterior raw surface because it's survival was not confirmed. Second step was reposition of remained auricule on the anterolateral thigh flap. In the second case, we packed in periauricular dead space and external auditory canal with temoporalis muscle and temporoparietal fascial flap and then covered the flap with split thickness skin graft. In these two cases, there were no recurrence of tumors and we obtained cosmetically & functionally satisfactory results.

Experimental Study on Effects of Inlet Boundary Layer Thickness and Boundary Layer Fence in a Turbine Cascade (터빈 캐스케이드 입구경계층 두께와 경계층 펜스 효과에 대한 실험적 연구)

  • Jun, Y.M.;Chung, J.T.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.853-858
    • /
    • 2000
  • The working fluid from the combustor to the turbine stage of a gas turbine makes various boundary layer thickness. Since the inlet boundary layer thickness is one of the important factors that affect the turbine efficiency. It is necessary to investigate secondary flow and loss with various boundary layer thickness conditions. In the present study, the effect of various inlet boundary layer thickness on secondary flow and loss and the proper height of the boundary layer fences for various boundary layer thickness were investigated. Measurements of secondary flow velocity and total pressure loss within and downstream of the passage were taken under 5 boundary layer thickness conditions, 16, 36, 52, 69, 110mm. It was found that total pressure loss and secondary flow areas were increased with increase of thickness but they were maintained almost at the same position. At the fellowing research about the boundary layer fences, 1/6, 1/3, 1/2 of each inlet boundary layer thickness and 12mm were used as the fence heights. As a result, it was observed that the proper height of the fences was generally constant since the passage vortex remained almost at the same position. Therefore once the geometry of a cascade is decided, the location of the Passage vortex and the proper fence height are appeared to be determined at the same time. When the inlet boundary layer thickness is relatively small, the loss caused by the proper fence becomes bigger than endwall loss so that it dominates secondary loss. In these cases the proper fence hight is decided not by the cascade geometry but by the inlet boundary layer thickness as previous investigations.

  • PDF

Effect of Varying Levels of Aflatoxin, Ochratoxin and Their Combinations on the Performance and Egg Quality Characteristics in Laying Hens

  • Verma, J.;Johri, T.S.;Swain, B.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.7
    • /
    • pp.1015-1019
    • /
    • 2003
  • A 50 day feeding trial was conducted with White Leghorn (WL) laying hens, 42 weeks old, to determine if feeding of varying levels of aflatoxin (AF), ochratoxin A (OA) or their combinations has any effect on their performance and egg quality parameters. Feeding of $T_4$, $T_7$, $T_8$, $T_9$ and $T_10$ caused significant reduction in feed intake of hens. Hen day egg productions were significantly reduced at all the levels of toxins except 0.5 ppm of AF. Maximum reduction in egg production was noticed at 2 and 4 ppm of AF and OA, respectively. Average body weight and egg weight were not affected by toxin feeding. The feed efficiency in terms of net feed efficiency and feed consumed per dozen egg produced was significantly reduced at higher levels of both the toxins and their combinations. Feed consumption for production of 1 kg egg mass remained uninfluenced due to aflatoxin feeding whereas significant increase in the value of the same was noticed at 4 ppm level of OA and combination of 1 and 2 ppm of AF and 2 and 4 ppm of OA ($T_9$ and $T_10$), respectively. Various levels of OA (1-4 ppm) and all the combination of two toxins ($T_8$, $T_9$ and $T_10$) significantly altered the shape index of eggs in laying hens. The shell thickness was significantly reduced by higher level of AF (2 ppm), OA (2 and 4 ppm) and their combination. Albumen index, Haugh Unit and yolk index remained unchanged due to incorporation of toxins in the diet. It is concluded that AF, OA either singly or in combination at higher levels could depress the performance in terms of egg production and feed efficiency significantly. The egg quality parameters i.e. shape index and shell thickness were also significantly affected.

Effect Evaluation of Hole Defects in Adhesive on SIF of Interface Crack (접착층내 결함이 계면균열의 응력확대계수에 미치는 영향 평가)

  • Hyun, Cheol-Seung;Heo, Sung-Pil;Yang, Won-Ho;Ryu, Myung-Hae
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.299-303
    • /
    • 2001
  • Adherend-adhesive interface failure will occur on a macroscale when surface preparation or material quality are poor. It is well known that the stress singularity occurs at the edges of interface between the adhernds and the adhesive, and that crack will initiate from these positions. Also if bubbles are created and remained in the adhesive layer during the bonding process, the stress concentrates around these hole defects. In this paper, the effects of the hole defects on the SIF of interface crack were examined. From results, SIF increased with the hole defects near the interface crack and increased with an decreae in the upper adherend thickness, an increase in the center adhesive thickness.

  • PDF

Effect of Hexavalent Chromium on Egg Laying Capacity, Hatchability of Eggs, Thickness of Egg Shell and Post-Hatching Development of Gallus domesticus

  • Asmatullah, Asmatullah;Asma, A.;Latif, A.;Shakoori, A.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.6
    • /
    • pp.944-950
    • /
    • 1999
  • Hexavalent chromium (CrVI) was fed to one day old chicks of Gallus domesticus in the form of different concentrations (250 and 500 mg/kg feed) of potassium dichromate mixed with the feed, ad libitum, for 32 weeks. After 20 weeks of feeding, the total body weight was higher in the low dose (260 mg/kg (feed) group and lower in the high dose (500 mg/kg feed) group, as compared with the control chicks. After 32 weeks of feeding, however, the total body weight was significantly decreased in both the treated groups. Egg laying was enhanced. Fertility remained unaffected, whereas hatchability was considerably decreased after CrVI-treatment. The egg shell thickness increased significantly (13%). Cr was deposited in a dose dependent manner in the liver and lungs. Some structural derangements in liver were also noted in treated chicks. The results of this study i.e., rapid ageing, excessive Cr deposition, decreased hatchability and hepatotoxicity indicate toxic effects of CrVI.

Application of CR-39 Microfilm for Rapid Discrimination Between Alpha-Particle Sources

  • Dwaikat, Nidal;Al-Karmi, Anan M.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.881-885
    • /
    • 2017
  • This work presents a new technique for discriminating between alpha particles of different energy levels. In a first study, two groups of alpha particles emitted from radium-226 and americium-241 sources were successfully separated using a CR-39 microfilm of appropriate thickness. This thickness was adjusted by chemical etching before and after irradiation so that lower-energy particles were stopped within the detector, while higher-energy particles were revealed on the back side of the detector. The number of tracks on the front side of the microfilm represented all alpha particles incident on that side from the two sources. However, the number of tracks on the back side of the microfilm represented only the long-range alpha particles of higher energy that arrived at that side. Therefore, by subtracting the number of tracks on the back side from the number of tracks on the front side, one could easily determine the number of tracks for the short-range alpha particles of lower energy that remained embedded in the microfilm. Discrimination of the two energy levels is thus achieved in a simple, fast, and reliable process.

THE EXPERIMENTAL STUDY ON THE HEALING PROCESS AFTER THE INLAY IMPLANTATION OF TOOTHASH-PLASTER MIXTURE BLOCK (치아회분과 석고를 혼합하여 제작한 block의 inlay 매식후 치유과정에 관한 실험적 연구)

  • Kim, Yung-Kyun;Yeo, Hwan-Ho;Park, In-Soon;Jo, Jae-O
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.2
    • /
    • pp.253-260
    • /
    • 1996
  • The purpose of this investigation was to determine the possibility of clinical use of toothash-plaster block implant material with ratio of 2 : 1 by weight. We made 1cm diameter round partial thickness defect at both sides of calvaria. Right side was implanted with block and left side was not implanted as a control site. The following results were obtained : 1. In gross examinations, the implanted site had a hardness on palpation and the margin with host bone was not identified clearly at 12 weeks after operation. But control site contained the fibrous tissue. 2. In the light microscopic examinations, most of the implanted sites were repaired by newly-formed bone at 12 weeks postoperatively. 3. At 8 weeks postoperatively, the implanted particles were divided into small granules and the amount was decreased gradually. Some remained particles were united directly with newly-formed bone. But the implanted particles still remained partly at 24 weeks postoperatively.

  • PDF