• Title/Summary/Keyword: Reliable transfer

Search Result 445, Processing Time 0.029 seconds

Anti-icing Method of Heated Walkway in Ice Class Ships: Efficiency Verification of CNT-based Surface Heating Element Method Through Numerical Analysis

  • Woo-Jin Park;Dong-Su Park;Mun-Beom Shin;Young-Kyo Seo
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.215-224
    • /
    • 2023
  • While melting glaciers due to global warming have facilitated the development of polar routes, Arctic vessels require reliable anti-icing methods to prevent hull icing. Currently, the existing anti-icing method, i.e., the heating coil method, has disadvantages, such as disconnection and power inefficiency. Therefore, a carbon nanotube-based surface heating element method was developed to address these limitations. In this study, the numerical analysis of the surface heating element method was performed using ANSYS. The numerical analysis included conjugate heat transfer and computational fluid dynamics to consider the conduction solids and the effects of wind speed and temperature in cold environments. The numerical analysis method of the surface heating element method was validated by comparing the experimental results of the heating coil method with the numerical analysis results (under the -30 ℃ conditions). The surface heating element method demonstrated significantly higher efficiency, ranging from 56.65-80.17%, depending on the conditions compared to the heating coil method. Moreover, even under extreme environmental conditions (-45 ℃), the surface heating element method satisfied anti-icing requirements. The surface heating element method is more efficient and economical than the heating coil method. However, proper heat flux calculation for environmental conditions is required to prevent excessive design.

Assessment of MARS-KS prediction capability for natural circulation flow in passive heat removal system

  • Jehee Lee;Youngjae Park;Seong-Su Jeon;Ju-Yeop Park;Hyoung Kyu Cho
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3435-3449
    • /
    • 2024
  • Considering that system analysis codes are used for the evaluation of the performance of Passive Safety Systems (PSSs), it is important to investigate the capability of the system analysis code to reliably predict the heat transfer and natural circulation flow, which are the main phenomena governing the performance of a PSS. Since MARS-KS has been widely validated for heat transfer models, this study focuses on evaluating its capability to predict the single and two-phase pressure drops and natural circulation flow. The straight pipe simulation results indicate that the pressure drop predictions are reliable within ±5 % error margin for the single-phase flow and the errors of pressure drop up to - 30 % for the two-phase flow. Through single-phase natural circulation flow analysis, it is concluded that the use of the appropriate K-factor modeling based on the flow regimes is important since the natural circulation flow rate in MARS-KS is mainly affected by the form loss factor modeling. With two-phase natural circulation flow analysis, this study emphasizes the behavior of the system could change significantly depending on the two-phase wall friction and pressure loss modeling. With the analysis results, modeling considerations for the PSS performance evaluation with the system analysis codes are proposed.

Selection of Early Cleaved Embryos and Optimal Recipients to Improve Efficiency of Pig Cloning

  • Koo, Ok-Jae;Lee, Dong-Won;Kang, Jung-Taek;Kwon, Dae-Kee;Park, Hee-Jung;Park, Sol-Ji;Kim, Su-Jin;Jang, Goo;Lee, Byeong-Chun
    • Journal of Embryo Transfer
    • /
    • v.25 no.4
    • /
    • pp.221-227
    • /
    • 2010
  • Early cleavage is a reliable prognostic tool for successful embryo transfer in assisted reproduction because early cleaved embryo show better pregnancy rate after transfer. There for, preparation of good embryo recipient is important factor to optimize efficiency of pig cloning. The present study was performed to evaluate the effect of early cleavage on the in vivo development of cloned embryos and to analyze breed, parity and estrous synchrony to optimize recipient for pig cloning. In vitro matured porcine oocytes derived from local slaughterhouse and fibroblasts derived from miniature pig fetuses were used for somatic cell nuclear transfer (SCNT). Reconstructed embryos were transferred to recipient pigs on the same day of SCNT or after 1~2 days of in vitro culture for selecting early cleaved embryos. Breed, parity and date of standing estrous of recipients were recorded for analysis. After 25~35 days after embryo transfer pregnancy was diagnosed using ultrasonography, and pregnant recipients were monitored till delivery. Between purebred and crossbred, no significant difference was founded in both pregnancy and delivery rates. However, early cleaved embryos showed significantly higher pregnancy (46.2%) and delivery (12.8%) rates compared to non-selectively transferred group (24.8% and 4.5%, respectively). The results also showed that the recipients showing standing estrous on the same day of SCNT and less than 4 parities were most suitable for pig cloning.

A Study on the Thermal Design for A Signal Processor in the Micro-Wave Seeker (초고주파 탐색기 신호처리부의 방열설계에 관한 연구)

  • Lee, Won-Hee;Yu, Young-Joon;Kim, Ho-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.1
    • /
    • pp.76-83
    • /
    • 2011
  • This paper focuses on the thermal design of a signal processor in Micro-Wave Seeker. High temperature environment and ESS(Environmental Stress Screening) test condition should be considered in designing a signal processor. First, we performed the thermal analysis to know conditions under which a signal processor is thermally reliable. As a result of thermal analysis, we found that adopting heat transfer block to the thermally fragile components is most efficient, because the heat transfer block can control the thermal loads of the individual components. Next, we verified this solution by numerical simulation and experiment and concluded that thermal reliability of a signal processor can be achieved. Maximum temperature difference between numerical simulation and experiment is about $2^{\circ}C$.

Analysis of Free Flap Reconstruction of the Tongue (유리피판을 이용한 설재건술의 분석)

  • Kang, Dong Hee;Lee, Hyung Chul;Koo, Sang Hwan;Park, Seung Ha;Jung, Kwang Yoon
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.557-562
    • /
    • 2006
  • Purpose: Advanced carcinoma of the tongue is a devastating disease which may cause severe speech or swallowing dysfunction. But, none to date has provided all of the complex functions of the tongue. The purpose of this study is to review our experiences with individuals who underwent glossectomy followed by reconstruction using free tissue transfer. Methods: Between February 1998 and February 2005, twenty-four patients underwent glossectomy followed by free tissue transfer reconstruction. The defects of tongue caused by partial or subtotal glossectomy were reconstructed by means of radial forearm or lateral thigh free flap with nerve innervation. Especially for the patients who underwent total glossectomy, we reconstructed deglutition muscles anatomically with nerve reinnervation, a procedure that allows the grafted muscle to maintain good tongue bulk without obvious atrophy. Results: Patients were reviewed to determine their functional outcome as it related to speech, deglutition, and aspiration. All patients achieved oral intake of a soft diet and acceptable speech. Conclusion: Although reconstruction following glossectomy using free tissue transfer is not ideal, this procedure is safe and reliable, and provides predictable results. A future challenge is the development of a surgical procedure for reconstruction of a tongue that maintains mobility and sensation using neurotized flaps.

Investigation on Ultrasonographic Observation of Recipient Ovaries, Serum Progesterone Level Measurement and Their Relationship with Pregnancy Rate (수란우의 초음파진단에 의한 난소 상태 및 혈청 Progesterone 농도가 수정란이식 후 수태율에 미치는 영향)

  • 김일화;류일선;서국현;이동원;박수봉;김현종;연성흠;박성재;허태영
    • Journal of Embryo Transfer
    • /
    • v.15 no.3
    • /
    • pp.263-270
    • /
    • 2000
  • The ovaries of 178 Holstein heifers or cows (heifer; 41, 1 parity; 72, 2$\leq$ parity; 65) on Day 6 or 7 (Day 0=day of estrus) were examined by transrectal ultrasonography. Diameter of corpus luteum (CL) and large follicle ( $\geq$ 10 mm), and luteal tissue area were determined by ultrasound system with a 5 MHB rectal probe. Blood samples were taken to progesterone analysis. After selection of recipients, frozen Holstein embryos were thawed and directly transferred to recipients non-surgically. The diameter of CL and luteal tissue area was greater (P<0.01) on Day 7 than on Day 6 in heifers, 1 parity or 2 $\leq$ parity cows, respectively, although progesterone concentrations were not different. The presence of fluid-filled luteal cavitied or multiple CL (2 or more) did not affect serum progesterone concentration. A large follicles were observed in 67.4% of heifers or cows and the average diameter was 14.1 mm. Greater luteal tissue area attributed higher pregnancy in heifers, but not in cows, although there were no difference on pregnancy rate according to progesterone concentration in heifers or cows. The pregnancy rate of recipients contained a large follicle at embryo transfer was lower than that of recipients not contained. These results show ultrasonic assessment of ovaries in Holstein recipients is a reliable tool to determine the follicle and CL for recipient selection.

  • PDF

Validation of Energy and Water Fluxes Using Korea Land Data Assimilation and Flux Tower Measurement: Haenam KoFlux Site's Hydro-Environment Analysis (Flux Tower 관측자료와 KLDAS를 이용한 Soil-Vegetation-Atmosphere Transfer 모형의 적용:해남 KoFlux 지점의 수문순환 환경분석에 대하여)

  • Kim, Daeun;Lim, Yoon Jin;Lee, Seung Oh;Choi, Minha
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3B
    • /
    • pp.285-291
    • /
    • 2011
  • Accurate assessment of the water and energy cycles is essential to understand hydrologic, climatologic, and ecological processes. Common Land Model (CLM) is one of the well-developed Soil-Vegetation-Atmosphere Transfer (SVAT) models based on the water and energy balance equation for accurate prediction of hydro-environmental cycles. The CLM can estimate realistic and reliable results using relatively simple parameters. It has been widely used in the world, however in Korea practical applications of the CLM are rare due to lack of information and input data. In this study, the CLM with Korea Flux network (KoFlux) and Kore Land Data Assimilation System (KLDAS) data were individually validated for domestic applications. This study showed that all comparisons between observations and model results from KoFlux and KLDAS had reasonable correlation with determination coefficient of 0.73~1.00 via regression. The results confirmed the applicability of the CLM and the possibility of the KLDAS usage for the region where input data are not existed.

Combined raidation-forced convection in a circular tube flow (원관내 유동에서의 복사 및 강제대류 열전달에 관한 연구)

  • 임승욱;이준식;이택식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1652-1660
    • /
    • 1990
  • Combined radiative-convective heat transfer in a hot gas tube flow has been investigated numerically and experimentally. In the numerical analysis, a standard k-.epsilon. model is used for the evaluation of turbulent shear stresses and spherical harmonics method with the Weighted Sum of Gray Gases Model for the solution of radiative transfer equation. In the experimental study measured are the velocity and temperature of the hot gas flow generated by the propane gas combustion, and tude wall heat flux distribution. Numerical results are compared with experimental ones and it is confirmed that P-3 provides quite reliable results in the analysis of the combined radiation-convection system.

Next-Generation File Transfer Protocol Which support concurrent file transmissions effectively in Internet (인터넷에서 동시 파일 전송을 효과적으로 지원하는 NFTP의 설계 및 구현)

  • Choi, Jae-Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1C
    • /
    • pp.90-95
    • /
    • 2002
  • Though the FTP(File Transfer Protocol) has been used widely and stable, It has the structural weakness that can't support current file transmissions so that we have to wait the completion of previous file transmission when try to transmit another file. If try to transmit multiple files concurrently using this FTP, It has to forking multiple FTP servers and clients in each user's PC and ISP's host machine it would result in the waist of memory, resource of network and the high workload of system. In order to solving previous problem, in this paper I have designed the new model of FTP which based on multi-thread and created NFTP(Next-Generation FTP)protocol so that may reduce the workload of system and support current file transmission effectively. I have implemented NFTP and also applied to real service, as a result It have provided reliable service by reducing the workload of system and saved the waiting time which would happened.

Continuous Coating Process Development for PEFC Membrane Electrode Assembly (고분자 연료전지용 MEA 연속 코팅공정 개발)

  • Park, Seok-Hee;Yoon, Young-Gi;Kim, Chang-Soo;Lee, Won-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.110-112
    • /
    • 2006
  • Membrane electrode assembly (MEA) for polymer electrolyte fuel cell (PEFC) are commonly prepared in the research laboratory by spraying, screen-printing and brushing catalyst slurry onto membrane or other support material like carbon paper or polyimide film in a batch style. These hand applications of the catalyst slurry are painstaking process with respect to precision of catalyst loading and reproducibility. It has been generally mentioned that the adoption of continuous process is very helpful to develop the reliable product. In the present work, we report the results of using continuous type coater with doctor-blade to coat catalyst slurry for preparing the MEA catalyst layers In a faster and highly reproducible fashion. We show that while expectedly faster than batch style, the machine coater requires the use of slurry of appropriate composition and a properly selected transfer decal material in order to achieve superior MEA plat lnw loading reproducibility. To make highly viscous catalyst slurry that is imperative for using coater, we use 40wt.% Nafion solution and minimize the content of organic solvent. And the choice of proper high surface area catalyst is important in the viewpoint of making well-dispersed slurry. After catalyst coating onto the support material, we transferred the catalyst layer to both sides of Nafion membrane by hot-pressing In this case, the degree of transfer was Influenced by hot-pressing condition including temperature, pressure, and time. To compare the transferring ability, we compared so many films and detaching papers. And among the support, polyethylene terephthalate(PET) film shows the prominent result.

  • PDF