• Title/Summary/Keyword: Reliability measure

Search Result 1,738, Processing Time 0.025 seconds

Smart pattern recognition of structural systems

  • Hassan, Maguid H.M.
    • Smart Structures and Systems
    • /
    • v.6 no.1
    • /
    • pp.39-56
    • /
    • 2010
  • Structural Control relies, with a great deal, on the ability of the control algorithm to identify the current state of the system, at any given point in time. When such algorithms are designed to perform in a smart manner, several smart technologies/devices are called upon to perform tasks that involve pattern recognition and control. Smart pattern recognition is proposed to replace/enhance traditional state identification techniques, which require the extensive manipulation of intricate mathematical equations. Smart pattern recognition techniques attempt to emulate the behavior of the human brain when performing abstract pattern identification. Since these techniques are largely heuristic in nature, it is reasonable to ensure their reliability under real life situations. In this paper, a neural network pattern recognition scheme is explored. The pattern identification of three structural systems is considered. The first is a single bay three-story frame. Both the second and the third models are variations on benchmark problems, previously published for control strategy evaluation purposes. A Neural Network was developed and trained to identify the deformed shape of structural systems under earthquake excitation. The network was trained, for each individual model system, then tested under the effect of a different set of earthquake records. The proposed smart pattern identification scheme is considered an integral component of a Smart Structural System. The Reliability assessment of such component represents an important stage in the evaluation of an overall reliability measure of Smart Structural Systems. Several studies are currently underway aiming at the identification of a reliability measure for such smart pattern recognition technique.

Validity and Reliability of the Korean Version of a Tool to Measure Uncivil Behavior in Clinical Nursing Education (간호학생이 임상실습에서 경험하는 무례함 한국어판 측정도구의 타당도와 신뢰도)

  • Jo, Su Ok;Oh, Jina
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.22 no.4
    • /
    • pp.537-548
    • /
    • 2016
  • Purpose: This study aims to develop a Korean version of a tool to measure uncivil behavior in clinical training to examine the experiences of nursing students. Methods: The "Uncivil Behavior in Clinical Nursing Education Scale" was developed by Anthony and Yastik in 2011. This study procedure was based on DeVellis' instrument development guidelines. Data were collected from 220 senior-year nursing students from four different universities in four different locations. Two hundreds surveys were analyzed using SPSS software and AMOS. Results: Out of 20 questions, 13 were selected after reviewing the content validity, face validity, construct validity, and reliability. The factors of the Korean version scale were specified as "exclusion", "contempt", and "refusal." The general characteristics of the subjects that showed significant differences in the occurrence of incivility were gender, age, transfer student status, level of satisfaction with clinical training, and level of satisfaction with the clinical training environment. Conclusion: The "Korean-Uncivil Behavior in Clinical Nursing Education Scale" was partially modified to account for differences in language and culture, but its validity and reliability were verified. We suggest that nurse educators and supervisors will be able to better understand the relationship between nurses and nursing students in clinical training.

Development of New Data Analysis Method to Evaluate Reliability of the Sensor or Measured Data (댐 매설 계측기 및 계측결과의 원격 신뢰성 평가를 위한 신호처리 기법의 개발)

  • Park, Hyung Choon;Hwang, Hea Jin;Lee, Jong Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.34-44
    • /
    • 2012
  • Many kind of sensors in the dam produce a lot of data associated with the maintenance and safety of the dam. So it is important to measure the reliability of the sensor (or measured data). In this paper, the new method using modified coherence function is proposed to measure the reliability of the sensor remotely. To verify feasibility of proposed method in the field, proposed method was applied to data of piezometer and earth pressure cell. Through field applications, the potential of the proposed method was verified.

Reliability-Based Topology Optimization Using Single-Loop Single-Vector Approach (단일루프 단일벡터 방법을 이용한 신뢰성기반 위상최적설계)

  • Bang Seung-Hyun;Min Seung-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.8 s.251
    • /
    • pp.889-896
    • /
    • 2006
  • The concept of reliability has been applied to the topology optimization based on a reliability index approach or a performance measure approach. Since these approaches, called double-loop single vector approach, require the nested optimization problem to obtain the most probable point in the probabilistic design domain, the time for the entire process makes the practical use infeasible. In this work, new reliability-based topology optimization method is proposed by utilizing single-loop single-vector approach, which approximates searching the most probable point analytically, to reduce the time cost. The results of design examples show that the proposed method provides efficiency curtailing the time for the optimization process and accuracy satisfying the specified reliability.

A Study on the Reliability and Validity of Measuring the Range of Motion of the Elbow Joint Using a Smartphone Application

  • Lee, Jun Cheol
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.65-72
    • /
    • 2018
  • The purpose of this study was to assess the intra-tester and inter-tester reliability and validity of elbow flexion range of motion using a smart phone used by the general public. Thirty-one general people participated in this study. The range of motion in active elbow flexion was measured with a goniometer and smart phone over two times by two observers. The intra-taster and inter-tester reliability were evaluated using the intraclass correlation coefficient(ICC). The validity was measured by Pearson's correlation coefficient. The intra-observer reliability was good in all measured items ICC>0.900. The inter-observer reliability was high with ICC>0.806. All correlation coefficients of android app and goniometer were greater than 0.868 and showed a significant positive correlation (p<0.01). The range of motion measurement with a smart phone showed acceptable reliability. Therefore, using a smartphone to measure the range of motion of the elbow joint could provide convenience and economic benefits.

The Reliability Analysis of the Gross Motor Function Measure in Children with Cerebral Palsy (뇌성마비 아동에 대한 대운동 기능검사의 신뢰도 분석)

  • Lim, Sun-Kyu;Lee, Hae-Deok
    • Journal of Korean Physical Therapy Science
    • /
    • v.4 no.1
    • /
    • pp.265-289
    • /
    • 1997
  • The purpose of this studied was to examine the reliability analysis of the GMFM in children with C.P. The subject of this study were 40 C. P patient who had been hospitalized Department of Sam-Yook Rehabilitation Hospital. Subjects were 28 boys and girls, aged 6 to 8 years. Reliability of each dimension of the GMFM were analyzed using Cronbach coefficients and to examine the intra-rater reliability were using Pearson correlation coefficients. The result of reliability analysis of the GMFM revealed higher reliability values. The reliability of the total dimension score was 95. Test-retest revealed intra-rater correlation coefficients from .71 to .98. The study presents that GMFM is useful in assessment of function of children with C. P by the quantitative description of the function.

  • PDF

A Validation Study of the Measure of Constructs Underlying Perfectionism-Korean version (M-CUP-K) (한국어판 완벽주의 구성 척도의 표준화 연구)

  • Cheon, Jooah;Kang, Jee In;Namkoong, Kee;Kim, Hae Won;Sohn, Sung Yun;Kim, Se Joo
    • Anxiety and mood
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2016
  • Objective : This study was conducted to examine the reliability and validity of the Measure of Constructs Underlying Perfectionism-Korean version (M-CUP-K). Methods : Two hundred and six normal subjects completed a battery of measures including M-CUP-K, Frost Multidimensional Perfectionism Scale-Korean version (FMPS-K), and Beck Depression Inventory (BDI). Psychometric properties of the M-CUP-K were analyzed. Results : The principal component analysis for construct validity resulted in 56 items composed of 6 factors (factor 1 : Dissatisfaction-Reactivity to Mistakes; factor 2 : Order-Details and Checking ; factor 3 : Satisfaction ; factor 4 : High standards ; factor 5 : Perceived Pressure from Others-Perfectionism toward Others ; factor 6 : Black and White Thinking about Tasks and Activities), compared to the original version. The M-CUP-K total and subscale scores were more strongly correlated with those of the other perfectionism-specific measure, FMPS-K, with a correlation of 0.822 (convergent validity) than with those of the nonspecific depression measure (discriminant validity). The Cronbach's ${\alpha}$ value for internal consistency of M-CUP-K was in an excellent range (r=0.872-0.935). The test-retest reliability for external validity suggested a good temporal stability with a total score correlation of 0.827. Conclusion : This study revealed that the M-CUP-K has good reliability and validity. Therefore, the M-CUP-K can be used as a promising measure of perfectionism in Korea.

  • PDF

Reliability of Measured Popliteal Angle by Traditional and Stabilized Active-Knee-Extension Test

  • Kim, Min-Hee;Kim, Yong-Wook;Jung, Doh-Heon;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • The active-knee-extension (AKE) test has been used to measure hamstring muscle length. The traditional AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip fixed by straps, while the stabilized AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip stabilized using a pressure biofeedback unit providing lumbopelvic stabilization. The purpose of this study was to determine test-retest reliability of the traditional AKE test and stabilized AKE test. Twenty healthy adults participated in the study. The popliteal angles were measured with a digital inclinometer during each test. To assess the test-retest reliability between the 2 test sessions, intraclass correlation coefficients (ICCs) were calculated. The intrasubject coefficient of variation ($CV_{intra}$) was also calculated. To compare the traditional and stabilized AKE tests for changes in pressure, paired t-tests were applied. The results of this study were as follows: 1) ICCs(3,1) value for test-retest reliability was .96 in the traditional AKE test, and was .98 in the stabilized AKE test. 2) The maximal $CV_{intra}$ was 33.7% in the traditional AKE test and 15.7% in the stabilized AKE test. 3) Differences of $6.1{\pm}2.1$ mmHg in pressure were measured in the traditional AKE test, and differences of $1.2{\pm}1.0$ mmHg in pressure were measured in the stabilized AKE test. The results show the traditional and stabilized AKE test to be highly reliable, with test-retest reliability. However, the stabilized AKE test represented less variation and more stabilization than the traditional AKE test. Further study is needed to measure the inter-rater reliability of the stabilized AKE test for generalization and clinical application.

  • PDF

Reliability and Validity of the Balancia using Wii Balance Board for Assessment of Balance with Stroke Patients (뇌졸중 환자들의 균형평가를 위한 Balancia 프로그램의 신뢰도와 타당도)

  • Park, Dae-Sung;Lee, Dong-Yeop;Choi, Sung-Jin;Shin, Won-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2767-2772
    • /
    • 2013
  • Balance is the foundation for all active daily livings. Evaluation of balance has been conducted to measure postural sway of center of pressure(COP). The purpose of this study is to introduce the Balancia and to examine the validity and inter-, intra-reliability for measure of balance with stroke patients. COP was measured by Wii balance board. The subjects Participated in this study were 39 stroke patients. Intra- and inter-reliability was examined using intraclass correlation coefficient(ICC) with 95% confidence interval. In the result of intra- and inter-reliability, all COP parameters of postural sway showed high to very high reliability with ICC=.793-.939 and ICC=.791-.955. Validity was determined by correlation with Accusway force plate. There were high validity with ICC=.851-.955 between tools. According to these results, the Balancia showed high validity and reliability. It is a useful clinical tool for evaluating balance in stroke patients.

A Comparison of Reliability and Anterior Glide Distance of Humerus Head of Passive Shoulder Internal Rotation Range of Motion Measurement Methods (어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교)

  • Kim, Hyun-Sook;Lee, Won-Hwee;Choung, Sung-Dae
    • Physical Therapy Korea
    • /
    • v.17 no.3
    • /
    • pp.1-10
    • /
    • 2010
  • The purpose of this study was to measure intra-rater and inter-rater reliability and range of motion for measurement of passive shoulder internal rotation range of motion and to compare anterior glide distance of humeral head in three methods. Fifty healthy subjects and fifty patients with shoulder musculoskeletal pain were recruited for this study. The subjects' passive shoulder internal rotation range of motion was measured by visual estimation, manual stabilization, and pressure biofeedback unit methods. In two trials, measurements were performed on each subject by two examiners. Intraclass correlation coefficient (ICC(3,1)) was used to determine the reliability of each measurement. The intra-rater reliability of the three methods was excellent (ICC=.77~.93) in both groups. The inter-rater reliability of the visual estimation method was poor (ICC=.20, .29), the manual scapular stabilization method was poor and fair (ICC=.09, .50), and the pressure biofeedback unit method was excellent (ICC .86, .75) in the experimental and control groups. In the experimental group, the difference of examined range of motion by each examiner was significant in the visual estimation method and manual scapular stabilization method, but there was an insignificant difference between the groups is the pressure biofeedback unit method. This result suggests that the intra-rater and inter-rater reliability of a pressure biofeedback unit was better than the other methods. The difference in distance of the anterior glide of humeral head was insignificant among all the methods. The pressure biofeedback unit method was the most reliable method, so it is proposed to be a new and reliable method to measure internal rotation range of motion.