• 제목/요약/키워드: Reliability assessment

검색결과 2,317건 처리시간 0.03초

저장탄약의 품목별 신뢰도평가 사례 연구 (A Case Study on the Reliability Assessment of Stockpile Ammunition)

  • 윤근식;이종찬
    • 품질경영학회지
    • /
    • 제40권3호
    • /
    • pp.259-269
    • /
    • 2012
  • Purpose: The purpose of this study was to find out that the statistical method of stockpile reliability of ammunition by items can be applied to the reliability assessment of stockpile ammunition. Methods: We reviewed the statistical method of stockpile reliability of ammunition by items and verified the possibility of its application by case study. Results: We found that the statistical method of stockpile reliability of ammunition by items is very useful and effective to present the reliability of ammunition based on each item and to predict the change of the reliability in the future. The reliability of proximity fuse was about 94.5% and was influenced by manufacture's year and the difference between lot and lot more than storage period. Conclusion: The statistical method of stockpile reliability of ammunition by items can be applied to the reliability assessment of various stockpile ammunitions such as ammunition for mortar and canon.

Study on Properties and Accelerated Life-time Test of Rubber O-ring by Temperature Stress

  • Shin, Young-Ju;Kang, Bong-Sung;Chung, Yu-Kyung;Choi, Kil-Yeong;Shin, Sei-Moon
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2006년도 학술발표대회 논문집
    • /
    • pp.48-54
    • /
    • 2006
  • In this thesis, accelerated life test (ALT) method and procedure for rubber O-ring are applied to assure specified reliability of the products at guaranteeing the life of the products. Rubber O-ring is parts that keep intensity or make machine operation smoothly on attrition portion of machine and is used to prevent that oil is leaked. Usually. Rubber O-ring used NBR that is copolymer of acrylonitrile and butadiene. this are superior oil resistance, heat resistance, durability of abrasion, cold resistance, chemical resistance etc. The accelerated life test model for rubber O-ring are developed using the relationship between stresses and life characteristics of products. Using the accelerated life test method and the acceleration life test equipment which is developed, we performed life test, collected life data and analyzed the results of tests. The proposed accelerated life test method and procedure may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably.

  • PDF

Substation Reliability Assessment Considering Non-Exponential Distributions And Restorative Actions

  • Kim, Gwang-Won;Lee, Kwang Y.
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.155-160
    • /
    • 2003
  • Reliability assessment of power systems has been an important topic for the past several decades. It is becoming even more important nowadays as the power market moves toward a new competitive environment. This paper deals with two topics on reliability assessment. The first is how to select probability distributions and determine their parameters to model the probabilistic events in a power system. The second is how to consider restorative actions in the assessment, which directly influence reliability indices. This paper proposes simple but convincing alternative solutions on the two topics. In the case study, this paper shows the influences of the probability distributions that are used in power system modeling.

전력기기 내환경특성평가를 위한 복합가속열화시스템 제작 (The Combined Testing System for Simulating Condition of Acceleratedly Deteriorated Environment)

  • 이정기;김민규;김익수;정주영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.182-183
    • /
    • 2006
  • It has been studied about the important consideration in designing and construction of the reliability assessment facilities including the combined testing system for simulating condition of acceleratedly deteriorated environment, which enable to test and evaluate the large-sized HV power apparatus without any disassembly up to transmission class in this paper. Also it is described simply about its ratings and main technical specifications and trial running of the system. To evaluate the performance characteristics against combined test condition for various power installation, especially for the polymer type insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.

  • PDF

초고압 중전기기 절연시험설비 성능개선 연구 (A study on the performance improving of the dielectric test facilities for UHV heavy electric apparatus)

  • 이정기;김민규;정주영;김익수;김맹현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2100-2102
    • /
    • 2005
  • In this Paper, there have been brief review about the important consideration in laboratory planning and designing the dielectric testing facilities for heavy electric apparatus up to 800kV-class in the high voltage testing fields. To improve and reinforce the existing dielectric test facilities in the way of econo-mical and optimal condition, wide investigation and an analysis for a solution, especially overshoot compensation method. have been suggested. With the brief description about those matters in constructing and improving the test facilities, the specification of each facility has been shown in the paper.

  • PDF

대전류 표준측정시스템에 대한 STL 최종방안의 소개 (The Introduction of the Final Proposal for the High-current Standard Measurement System)

  • 정주영;신영준;김익수;김민규;이정기;김맹현;이용한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.403-405
    • /
    • 2003
  • 본 논문에서는 대전류 표준측정에 대한 STL TC의 Ad-Hoc Working Group의 최종방안에 대해 자세히 소개하여 이를 계기로 국내에서도 필요한 사전준비에 만전을 기하고자 한다. 향후 연속적으로 해야 할 업무, Shunt의 소유, 경비 지불방법 등에 대한 사항과 함께 우리나라 대전류 표준측정시스템의 구축절차를 제안하였으며, 이를 통해 대전류 측정에 있어서 국제표준과의 소급성을 확보할 수 있기 때문에 국내에서 시행하는 각종 시험에서 대전류 측정이 국제적으로 유효하게 될 것이다.

  • PDF

대전류 표준측정시스템에 최종방안의 기술적 배경에 대한 고찰 (A Study on the Technical Background of the Final Proposal for the High-current Standard Measurement System)

  • 정주영;신영준;김익수;김민규;이정기;김맹현;이용한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.409-411
    • /
    • 2003
  • 본 논문에서는 대전류 표준측정에 대한 STL TC의 Ad-Hoc Working Group의 최종방안에 대한 기술적 배경을 소개하여 이를 계기로 국내에서도 대전류 표준확보에 필요한 사전준비에 만전을 기하고자 한다. STL의 대전류 reference shunt 요구사항, 측정 불확도 및 각 시험소에서 교정하여야 할 사항 등에 대하여 검토하고, 우리나라 대전류 표준측정시스템의 구축필요성, 구축절차 및 방안에 대하여 기술한다.

  • PDF

전력기기 내오손특성 평가기반 구축 (Construction of the infrastructure for evaluating characteristic against contamination for power installation)

  • 이정기;김민규;문인욱;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1513-1514
    • /
    • 2006
  • In this paper, there have been brief review about the important consideration in laboratory planning and construction of the artificial pollution testing facilities including 300 kV, 1800 kVA AC test system, which enable to lest and evaluate the UHV dielectric performance of power insulators up to transmission class. Also it is described simply about its trial running of the whole test system. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.

  • PDF

New reliability framework for assessment of existing concrete bridge structures

  • Mahdi Ben Ftima;Bruno Massicotte;David Conciatori
    • Structural Engineering and Mechanics
    • /
    • 제89권4호
    • /
    • pp.399-409
    • /
    • 2024
  • Assessment of existing concrete bridges is a challenge for owners. It has greater economic impact when compared to designing new bridges. When using conventional linear analyses, judgment of the engineer is required to understand the behavior of redundant structures after the first element in the structural system reaches its ultimate capacity. The alternative is to use a predictive tool such as advanced nonlinear finite element analyses (ANFEA) to assess the overall structural behavior. This paper proposes a new reliability framework for the assessment of existing bridge structures using ANFEA. A general framework defined in previous works, accounting for material uncertainties and concrete model performance, is adapted to the context of the assessment of existing bridges. A "shifted" reliability problem is defined under the assumption of quasi-deterministic dead load effects. The overall exercise is viewed as a progressive pushover analysis up to structural failure, where the actual safety index is compared at each event to a target reliability index.