• Title/Summary/Keyword: Reliability Certificate

Search Result 64, Processing Time 0.021 seconds

A study on the Private Investigator usage for Cyber Crime (사이버범죄의 효과적인 대응을 위한 민간조사제도의 도입방안)

  • Shin, Hyun-Joo
    • Korean Security Journal
    • /
    • no.46
    • /
    • pp.63-86
    • /
    • 2016
  • The object of this study is to propose a study on the Private Investigator usage for Cyber Crime. The latest trend of cyber crime is being evolve in sophisticated and complex way over the global, like internet fraud, cyber gambling, hacking and etc. Hence national investigative authority mobilize high specialized skills and method of criminal investigation by each nation. But it is hard to respond in rapid and effective way because of propoor, distribution of group and insufficient of related legal system. Already in other countries, not considerable amount of services are given to private investigators in detection and tracking part which is inefficient by nation. So it has significantly meaningful to compensate the defect and study about private investigator usage as companion of cooperation policing for effectively respond to cyber-crime. The way to effectively deal with the cyber-crime is reevaluate meaning of partnership policing and need of private investigator usage. Also it is to analyze the main issue about introduction of a system and suggest the effective way of introduction. First, legislation of private investigator usage which is based upon partnership policing should be made up. Moreover, to establish the range of private investigator's business and enhance the reliability, it is to propose introduction of leading professional global certificate and license system with sufficient education and test. We are expecting introduction of private investigator usage can improve efficiency of investigation and promote effective countermeasures of cyber-crime.

  • PDF

The Evaluation of Recovery Rate of Radioimmunoassay Using Certified Reference Material (CRM) (인증표준물질(CRM)을 이용한 방사면역측정법의 회수율 평가)

  • Choi, Sung Hee;Shin, Sun Young;Lim, So Hee;Hong, Mee Kyung;Noh, Gyeong Woon;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.158-162
    • /
    • 2014
  • Purpose: Reference material (RM) is defined as material that is safe and homogeneous enough about specified characteristic that is made with a purpose of using test of measurement or nominal characteristic. Certified reference material (CRM), which is issued by authorized organization, is defined as reference material that provides characteristic value, link uncertainty and retroactivity. The purpose of this paper was to evaluate recovery of radioimmunoassay by Certified Reference Material enclosed with a certificate and therefore to enhance reliability of test. Materials and Methods: WHO certified reference material is purchased from NIBSC (National Institute for Biological Standard and Control, United Kingdom) and made of 3 levels that are C-1 (low concentration), C-2 (medium concentration) and C-3 (high concentration) and measured for kit at the Seoul National University Hospital. Recovery rate is evaluated after measurement at four different days. Results: Recovery rate results using WHO certified reference material are T4 90%, Ferritin 88%, PSA 94%, Prolactin 99%, AFP 94% and TSH 93%. Conclusion: A procedure that appropriate accuracy, precision, specificity, sensitivity, reproducibility, and validate on the subject of kit for radioimmunoassay is essential. Recovery rate assay as extraction efficiency of analysis process is percent about already measuring results of analysis result after all measuring process. This is very important assessment standards of performance evaluation of immunoassay kit. Recovery rate results of 6 type used WHO CRM are satisfactory to 88~99%. This demonstrates that the radioimmunoassay is a very accurate measurement, which is very effectively utilized in clinical practice.

  • PDF

Hybrid Blockchain Design to Improve the Security of Education Administration Information System (교육행정정보시스템의 보안성 강화를 위한 하이브리드 블록체인 설계)

  • Son, Ki-Bong;Son, Min-Young;Kim, Young-Hak
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.6
    • /
    • pp.1-11
    • /
    • 2021
  • The Neis System is a system integrating administrative information that was operated in elementary and secondary schools in Korea. Currently, this system is operated by a central server method and contains school administration information and important educational information of students. Among student information, the student life record contains important information for a student to advance to a higher level institution, but problems such as information leakage or manipulation may occur due to malicious attacks. In this paper, we propose a hybrid blockchain system that combines the server and blockchain technology managed by the existing Neis system. The proposed system records the query information of the database in a block when student information is accessed. When a request for correction of student information or issuance of a certificate is received, the query of the blockchain, the information in the database, and the student's key value are checked to determine whether the information has been leaked or manipulated, and only if the data is normal, the request for revision of the record is performed. This process is more secure than the existing central server because it checks the manipulation of data through the blockchain. The proposed system was implemented on the Ethereum platform, and the query information of the blockchain was experimentally verified using smart contracts. This study contributes to enhancing the reliability of the Nice system by strengthening the security against forgery and alteration of student data by combining the existing Nice system with a block chain.

Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters (유량측정 기기별 측정성과에 대한 실험적 비교분석)

  • Lee, Jae-Hyug;Lee, Suk-Ho;Jung, Sung-Won;Kim, Tae-Woong
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. However, it needs lots of time and money to get the discharge data. So discharge rating curve is usually used in converting discharge data. Therefore reliability of discharge rating curve absolutely depends on quality of discharge data. Many engineers who study hydrologic engineering make high quality discharge data to develop reliable discharge rating curve. And they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and experimental research data from measurement are not enough. In this paper, constant discharge flowed through standard concrete channel, and the velocity is measured using various flow meters. Also Discharge is calculated by measured data to compare and analyze. The equipment for the experiment is Price AA(USGS Type AA Current meter), flow meter, ADC, C2 small current meter, flow tracker, Electromagnetic current meter. The discharge got form various flow meters which are widely used for discharge measurement. The various depths of water were examined and compared such as 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m. The experiment progresses a round-measurement on 6-case. Wading measurement(one point method : the 60 % height in surface of the water) was applied to improve creditability and accuracy among measurement methods. USGS Type AA current Meter, Flow Meter, ADC, C2 Small Current meter got the certificate of quality guaranteed. So the results of experiment were used to compare discharge. The Results showed the difference based on USGS Type AA current Meter at average discharge and velocity. Electromagnetic current meter made differences over $\pm$ 10 % and Flow Meter made differences under $\pm$ 10 %. Also ADC, Flow Meter, C2 Small Current meter made differences under $\pm$ 5 %.