• Title/Summary/Keyword: Release pattern

Search Result 313, Processing Time 0.03 seconds

A study on the heat release rate pattern variation according to the change of operating conditions in pre-combution chamber type diesel engine (예연소실식 디젤기관의 운전조건변화에 따른 열발생률 형태변동에 관한 고찰)

  • 이진우;최재성;전효중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.31-44
    • /
    • 1987
  • Nowadays, the problems of energy and environmental pollution become serious day by day and the diesel engine, which has been proved to be superior to gasoline engine with respect to fuel consumption and ecological problems of exhaust gas, has been adopted widely for various purposes from the marine diesel engine and the dynamo engine to all kinds of engine on land. Therefore, extensive parametric studies on combustion of diesel engine should be done for its desing and improvement. To predict the behavior of diesel engien according to variable operating conditions by means of cycle simulation, the reasonable pattern of heat release rate has to be asumed. But it is necessary to know the actual variation of heat release rate in order to assume the reasonable pattern of heat release rate according to the actual operating conditions. In this paper, on a high speed small bore diesel engine with pre-combustion chamber, experimental investigations were carried out to determine the relationship between the heat release pattern and parameters such as engine load and speed. And also, the theoretical investigations about the performance variations of the above diesel engine according to the predicted pattern of heat release rate variation were performed. From the above observations, it may be said that the Fanboro indicator, which was used to get the cylinder pressure, can be used to estimate a reasonable pattern of heat release rate and it is confirmed that the pattern of heat release rate for the pre-combustion type engine is different from that of the direct injection type engine.

  • PDF

The Formulation and Dissolution Properties of Oral Sustained Release Sulindac Delivery System (설린닥의 경구용 지속성 제제설계 및 용출특성)

  • Rhee, Gye-Ju;Park, Sun-Hee;Suh, Sung-Su;Whang, Sung-Joo
    • YAKHAK HOEJI
    • /
    • v.41 no.1
    • /
    • pp.48-59
    • /
    • 1997
  • Sustained release matrix tablets, pellets, and coated pellets for the delivery of sulindac were prepared using cellulose derivatives at various ratios, and evaluated for the dis solution pattern. The release of sulindac, from matrix tablets prepared with low viscosity HPMC was relatively fast, and especially the tablets made of Metolose SM released all of sulindac within 1 hr. The release of drug from tablets made of other HPMC derivatives were retarded in the order of the following: Pharmacoat 645>Pharmacoat 606>Pharrnacoat 606+HPC-L>HPC-L. The most sustained release pattern was observed with the preparation of high viscous polymer. Metolose 90 SH. While release of sulindac, from matrix type pellet containing 10mg/cap of Metolose 90 SH or 60 SH was completed within 1 hr, a prolonged release formulation (30% in 1 hr) was obtained by the inclusion of EC. Pellets coated with HPMC showed a fast release pattern (${\geq}$ 80% within 2 hrs), whereas pellets coated with HPMC and EC (molar ratio 1 : 1) showed a sustained release pattern (${\geq}$ 80% in 12 hrs), vath the release from EC pellets being the most sustained. Fast (naked) and slow release pellets coated with EC, Metolose 60SH 50cps and propylene glycol. and enteric pellets coated with HPMCP 55 and Myvacet$^{\circledR}$ were prepared, and combined at various ratios for the assessment of dissolution pattern. The result indicates the possibility that the development of 24 hr sustained release delivery systems containing sulindac for oral administration could be achieved by means of combining sustained and fast release pellets at a proper portion.

  • PDF

4-stroke 디젤엔진의 성능예측에 관한 연구

  • 오태식;오세종;양재신
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.58-68
    • /
    • 1982
  • It is well known to diesel engineers that the heat release pattern is one of the most important factors affecting engine performance. Thorough research in heat release pattern has materially helped the progress in high-speed diesel engine development . This paper is based on the research conducted at KAIST and Daewoo Heavy Industry last year. The purpose of this paper is to determine the heat release pattern in combustion chamber of MAN M type, the famous low-noise engine. Thermodynamic cycle simulation was performed using Whitehous-Way's heat release pattern with modified coefficients and Annand's heat transfer model. Instantaneous temperature and pressure of gas in cylinder could be determined by the numerical solution of simultaneous equation of mass conservation, equation of energy conservation, and state equation of ideal gas. Calculated results were compared with measured values in some details emphasizing upon the factors affecting rate of heat release. The agreement was fairly good and revealed why M type should have lower burning velocity at the early part of combustion in spite of high injection rate. Additional results by parametric studies were given in relation to fuel injection conditions for further application to engine development.

  • PDF

pH-Dependent Drug Release from Polymethacrylic Acid Hydrogel Matrix (Polymethacrylic Acid 하이드로겔 매트릭스로부터의 pH 의존성 약물 방출)

  • Kim, Kyung-Chung;Kim, Kil-Soo;Lee, Seung-Jin
    • Journal of Pharmaceutical Investigation
    • /
    • v.19 no.4
    • /
    • pp.179-183
    • /
    • 1989
  • Drug release experiments were performed based on pH-sensitive swelling behaviors of polymethacrylic acid. 5-Fluorouracil as a nonionic model drug revealed release patterns depending solely on pH-dependent swelling kinetics of polymethacrylic acid. In contrast, release of propranolol hydrochloride as a cationic model drug was significantly affected by ionic drug-polymer interaction as well as the swelling kinetics. Accordingly, a zero-order release pattern was obtained at pH 7, which was distinguished from the general matrix type drug release pattern.

  • PDF

Effect of Particle Size of HPMC on Dissolution Rate of Venlafaxine HCl and Carbamazepine Sustained Release Tablet (HPMC의 입도에 따른 염산벤라팍신 및 카바마제핀 서방성 정제의 용출 특성)

  • Cha, Jae-Uk;Cha, Ja-Hyun;Hong, Jun-Kee;Lee, Sung-Wan;Ko, Won-Hwa;Beak, Hyun-Ho
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.332-337
    • /
    • 2012
  • The primary objective of this work is to find the properties of sustained release dissolution pattern depending on solubility of drugs, so venlafaxine HCl and carbamazepine tablets were made by using polymer wich various particle size. Hydroxy propyl methyl cellulose (HPMC) has been utilized in this study as an excipient that is one of the most widely used polymers for an oral sustained release formulation, and drug release pattern was strongly influenced by swelling rate depending on particle size of HPMC. Scanning electron microscope (SEM) was employed to investigate the surface of tablets with various HPMC particle size, and differential scanning calorimeter (DSC) was employed to investigate the crystallization of drugs in tablets. The release model equation was applied to analyze the main mechanism of drug release pattern. The results demonstrate that drug release pattern is controlled by the drug solubility and HPMC particle size.

Preparation and Characterization of Poly(lactide-co-glycolide) Micro-spheres for the Sustained Release of AZT

  • Gilson Khang;Lee, Jin-Ho;Lee, Jin-Whan;Cho, Jin-Cheol;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • v.8 no.2
    • /
    • pp.80-88
    • /
    • 2000
  • Biodegradable microspheres were prepared with poly(L-lactide-co-glycolide) (PLGA, 75 : 25 by mole ratio) by an oil/oil solvent evaporation method for the sustained release of anti-AIDS virus agent, AZT The microspheres of relatively narrow size distribution (7.6$\pm$ 3.8 ㎛) were obtained by controlling the fabrication conditions. The shape of microspheres prepared was smooth and spherical. The efficiency of AZT loading into the PLGA microsphere was over 93% compared to that below 15% for microspheres by a conventional water/oil/water method. The effects of Preparation conditions on the morphology and in vitro AZT release pattern were investigated. in vitro release studies showed that different release pattern and release rates could be achieved by simply modifying factors in the fabrication conditions such as the type and amount of surfactant, initial amount of loaded drug, the temperature of solvent evaporation, and so on. PLCA microspheres prepared by 5% of initial drug loading, 1.0% (w/w) of surfactant concentration, and 25$\^{C}$ of solvent evaporation temperature were free from initial burst effect and a near-zero order sustained release was observed. Possible mechanisms of the near-zero order sustained release for our system have been proposed.

  • PDF

Drug Release by Poly(DL-lactide) Coated Chitosan Derivatives Matrices (Poly(DL-lactide)로 피막된 키토산 유도체 매트릭스에서의 약물방출)

  • 차월석;나재운이동병
    • KSBB Journal
    • /
    • v.10 no.4
    • /
    • pp.461-467
    • /
    • 1995
  • In this study, the release experiments of drug were operated in the phosphate buffer solutions of pH 7.4 and pH 1.2 by using drug carriers(chitosan, chitosan hydrochloride, and sulfonated chitosan)coated by poly(DL-lactide) with prednisolone for delivery drug. The release time of drug was more delayed in pH 7.4 than in pH 1.2. The release time of according to the kinds of drug carrier was delayed in the order of chitosan, sulfonated chitosan, and chitosan hydrochloride. In short, the formulation allows biodegradable coated monolithic polymetic matrices to suppress the burst effect of the drug release mechanism, which led to the sustained release pattern.

  • PDF

Release Characteristics of Terbutaline Sulfate Sustained-Release Beads In Vitro (서방성 Terbutaline sulfate bead의 방출특성)

  • Kim, Ki Man;Kim, Young Il;Hong, Soon Uk
    • Korean Journal of Clinical Pharmacy
    • /
    • v.1 no.1
    • /
    • pp.23-30
    • /
    • 1991
  • The sustained-release beads containing terbutaline sulfate (TBS) were prepared by rotogranulation method. The drug was dusted on the non-pareil seeds in a CF-granulator. The sustained-release beads were obtained by coating the active beads with ethylcellulose or $Eudragits^{(R)}$, using in any case the same granulator employed for active beads preparation. The release characteristics of sustained-release beads were examined in vitro by rotating basket method applied to $Bricanyl^{(R)}$ durules which is a sustained-release TBS matrix tablet. The release of terbutaline from the beads in vitro was first-order, and the release rate was dependent on both the coat weight ratio and membrane hydrophilicity. Both surfaces of the beads before and after dissolution were smooth. The drug release pattern from the beads could be thought the diffusion through the polymer membrane. The release rate and the surface of the beads stored for 3 years at room temperature were the same with those of the initial beads.

  • PDF

The Comparative Study of the Warranty Cost Model for Software Reliability Time Based on Extreme Value Distribution (극값 분포 특성을 가진 소프트웨어 신뢰성 보증 모형에 관한 비교연구)

  • Kim, Hee-Cheul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6B
    • /
    • pp.623-629
    • /
    • 2009
  • In this research, the process of developing software products to users in transfer by considering the warranty period to determine the timing of the release period is a comparative study of models. For the results of demonstration, exponential software reliability model increases the warranty period, the higher the initial period, but shows almost a similar release. In contrast, the optimal release time of imperfect debugging software reliability model, lower the initial warranty period, but the pattern is expected to rise slightly larger. The proposed model, extreme value distribution model, pattern of the optimal release time gradually increase, have a form that can be drawn. These research results through, warranty period and release the software developers understand the relationship between the optimal time for software development by using advance information could do is feed.

Preparation and Characterization of Pamidronate-loaded PLGA Wafer for the Treatment of Bone Resorption (골 재흡수 치료를 위한 파미드로네이트를 함유한 이식형 생분해성 PLGA 웨이퍼의 제조와 특성결정)

  • 유제영;김상욱;강길선;성하수;정제교
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.680-690
    • /
    • 2002
  • Implantable biodegradable wafers were prepared with pamidronate -loaded poly (L-lactide-co-glycolide) (PLGA, 75 : 25 mole ratio by lactide to glycolide, molecular weight : 20000 and 90000 g/mole) by direct compression method for the sustained release of pamidronate to investigate the possibility for the treatment of bone resorption. Pamidronate-loaded PLGA powders were prepared by means of physical mixing and spray drying with the control of formulation factors and characterized by scanning electron microscope and X-ray diffractometer. The pamidronate-loaded PLGA powders fabricated into wafers by direct compression under the constant pressure and time at room temperature. These wafers were also observed for their structural characteristic, release pattern, and degradation pattern. The release rate of pamidronate increased with increasing their initial loading ratio as well as increasing wafer thickness. The molecular weight of PLGA affects the release pattern : the higher molecular weight of PLGA, the faster release rate. It can be explained that the higher viscosity of high molecular PLGA solution at same concentration tends to aggregate PLGA and pamidronate resulting in unstable pharmaceutical dosage form. This system had advantages in terms of simplicity in design and obviousness of drug release rate and nay be useful as an implantable dosage form for the treatment of aural cholesteatoma.